Index Terms CONCRETE-FILLED FRP TUBE (CFFT); FIBER REINFORCED POLYMER (FRP) TUBE; REINFORCED CONCRETE (RC) COLUMN; HYDROCODE AUTODYN.

Similar documents
Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

Parametric study of FRP-strengthened reinforced concrete panels under blast. loads

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Behaviour of Concrete Filled Rectangular Steel Tube Column

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

NLFEA Fire Resistance of 3D System Ceiling Panel

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Nonlinear Analysis of Reinforced Concrete Column with ANSYS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Extreme Loading for Structures Version 3.1

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

Moment curvature analysis of concrete flexural members confined with CFRP grids

Study of Shear Behavior of RC Beams: Non Linear Analysis

PERFORMANCE OF RC BRIDGE COLUMNS SUBJECTED TO LATERAL LOADING

Nonlinear Finite Element Modeling & Simulation

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

GLASS FIBER-REINFORCED PLASTIC POLES FOR TRANSMISSION AND DISTRIBUTION LINES: AN EXPERIMENTAL INVESTIGATION

NONLINEAR FINITE ELEMENT ANALYSIS OF SHALLOW REINFORCED CONCRETE BEAMS USING SOLID65 ELEMENT

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

Effects Of Slenderness Ratio In RC Slender Column Using GFRP And CFRP Confinement

ZANCO Journal of Pure and Applied Sciences

GFRP retrofitted RC frames with columns subjected to high axial stresses

FE Review Mechanics of Materials

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Behaviour of FRP wrapped circular reinforced concrete columns

STRUCTURAL BEHAVIOUR OF HOLLOW STEEL SECTIONS UNDER COMBINED AXIAL COMPRESSION AND BENDING

STUDY ON SEISMIC BEHAVIOR OF KNEE BRACED STEEL FRAMES

Numerical Analysis of Torsional Behavior of Ultra-High Performance Fiber Reinforced Concrete

Comparative Study On Seismic Behaviour Of Steel Knee Braced Frame With Eccentric Braced Frame

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Testing and analysis of masonry arches subjected to impact loads

Analysis of concrete columns Reinforced by Fiber Reinforced Polymers Bars Mohamed Husain, Hilal Hassan, Eman Salama

Non Linear Analysis of Composite Beam Slab Junction with Shear Connectors using Ansys.16

EXPERIMENTAL ANALYSIS ON THE SHEAR BEHAVIOUR OF RC BEAMS STRENGTHENED WITH GFRP SHEETS

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

FRP-CONCRETE-STEEL COMPOSITE STRUCTURAL MEMBERS. Yunita Idris. M.Eng (Structural Engineering) B.Eng. (Civil Engineering)

Effect of beam dimensions on structural performance of wide beam-column joints

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

EXTERNAL CONFINEMENT OF PLAIN AND REINFORCED CONCRETE COLUMNS USING PVC PIPES

Experimental Behavior of Concrete Cylinders Confined with CFRP Composites

Stress Analysis of Underground GRP Pipe Subjected to Internal and External Loading Conditions

Analytical Investigation of Seismic Performance of Exterior RC Beam-Column Joints Rehabilitated with New Scheme

Behaviour of FRP wrapped circular concrete columns under eccentric loading

Al-Ta'an : Nonlinear Finite Element Analysis of Fibrous Reinforced Concrete Beam- Received 14 Sep Accepted 19 Feb.

Seismic design of braced frame gusset plate connections

AN ANALYSIS OF THE BEHAVIOR OF HYBRID STEEL BEAM RC COLUMN CONNECTION

The strength of a material depends on its ability to sustain a load without undue deformation or failure.

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Modelling of RC moment resisting frames with precast-prestressed flooring system

BEHAVIOUR OF GLASS FIBER WRAPPED CONCRETE COLUMNS UNDER UNIAXIAL COMPRESSION

optimal design of frp retrofitting for seismic resistant rc frames C. Chisari 1, C. Bedon 2 1

Rate Dependency Plastic Modeling

FINITE ELEMENT ANALYSIS OF HISTORIC BRIDGE STRENGTENED WITH FRP LAMINATES. Abstract

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

Effect of FRP strengthening on the behavior of shear walls with opening

Analysis, Design, and Construction of SMA-Reinforced FRP- Confined Concrete Columns

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

ROBUST DESIGN ALTERNATE LOAD PATH METHOD AS DESIGN STRATEGY

On Finite Element Analysis of Steel and RC Beams : Performance of Different Elements

Design & Analysis of Mono Composite Leaf Spring

TORSION SIMPLIFIED: A FAILURE PLANE MODEL FOR DESIGN OF SPANDREL BEAMS

DUCTILITY REQUIREMENTS FOR BUILDINGS

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

NON-LINEAR ANALYSIS OF RC FRAMES WITH MASONRY INFILLS SUBJECTED TO COLUMN FAILURE

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

5.4 Analysis for Torsion

Seismic Performance of GFRP-RC Exterior Beam-Column Joints with Lateral Beams

Flexural Behavior of Sandwich Composite Panels Under 4-Point Loading

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

Study on Beam-to-Column Connection with Viscoelastic Hysteretic Dampers for Seismic Damage Control

DYNAMIC BEHAVIOR OF A STEEL PLATE SUBJECTED TO BLAST LOADING COMPORTEMENT DYNAMIQUE D UNE PLAQUE D ACIER EXPOSÉE AU SOUFFLE D UNE CHARGE EXPLOSIVE

Reliability analysis of RC slabs with or without FRP strengthening to blast loads

Finite Element Modelling of RC Beams Retrofitted with CFRP Fabrics

Modelling shearing characteristics of reinforced concrete

Overview of Presentation. SCBFs are Conceptually Truss Structures

SHEAR PERFORMANCE OF EXISTING REINFORCED CONCRETE T-BEAMS STRENGTHENED WITH FRP

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

SEISMIC BEHAVIOR OF STEEL RIGID FRAME WITH IMPERFECT BRACE MEMBERS

Shake Table Analysis of Concrete Structural Models. Keywords: Earthquake, Fiber Reinforced Polymer, shake table, tape confinement, wire mesh.

Available online at ScienceDirect

Dynamic Compressive Behavior of FRP-Confined Concrete Under Impact and a New Design-Oriented Strength Model

STUDY OF THE BEHAVIOUR OF WELDED T-JOINTS IN HOLLOW CIRCULAR STEEL SECTIONS

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

The cracking behaviour of reinforced concrete beams under static and dynamic loading

Design and Analysis of Multilayer High Pressure Vessels and Piping Tarun Mandalapu 1 Ravi Krishnamoorthy. S 2

DESIGN OF STEEL FIBRE REINFORCED CONCRETE BEAMS USING THE NEW FIB MODEL CODE 2010 AN EVALUATIVE

Nonlinear Analysis of Concrete Beams Strengthened with Steel Fiber-Reinforced Concrete Layer

PRESSURE-IMPULSE DIAGRAMS USING FINITE ELEMENT ANALYSIS FOR REINFORCED CONCRETE COLUMNS SUBJECTED TO BLAST LOADING. A THESIS IN Civil Engineering

Transcription:

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 208 Behaviour of Concrete Filled Fiber Reinforced Polymer Tube under Blast Loading SruthySagaran V,SruthiK Chandran Abstract:In recent years, the public concern about safety has increased dramatically because of the tremendous increase in the number of explosive industrial accidents and terrorist attacks all over the world. Due to the threat from such extreme loading conditions, efforts have been made to develop methods of structural analysis and design to resist blast loads. Studies were conducted on the behavior of structural concrete subjected to blast loads. Improvement to existing construction methods that enhance blast resilience can ultimately save lives and property. Concrete filled FRP tubes (CFFTs) are known to improve a conventional reinforced concrete member s resistance to traditional loads by strengthening, protecting, and confining the reinforced concrete core. This paper outlines a numerical model built using commercially available software AnsysAutodyn to predict the response of concrete filled fiber reinforced polymer (FRP) tubes (CFFT) and determine the factors influencing their response. The comparison of dynamic behaviour CFFT and reinforced concrete (RC) column under blast loading has done. From the study it is clear that CFFT is more blast resilient than RC column. The parametric study was done on the effect of standoff distance and charge weight. Index Terms CONCRETE-FILLED FRP TUBE (CFFT); FIBER REINFORCED POLYMER (FRP) TUBE; REINFORCED CONCRETE (RC) COLUMN; HYDROCODE AUTODYN. 1 INTRODUCTION lasts loading on columns are of great importance because columns tend to be critical load bearing B members whose collapse may initiate a progressive collapse of the structure. Thus, any improvement in the blast resistance of columns can potentially save lives and property. CFFT member is an innovative idea, in which a FRP element acts together with a concrete element. CFFT structures are carrying loads far in excess of their design loads because of their conservative design by modern standards. Glass fiber reinforced polymer (GFRP) tubes used as confinement. Hence it is necessary to restore or enhance the load carrying capacity and increase the life span of the structures. Numerical and experimental investigation of concrete-filled FRP tube has been investigated extensively as in the study of Wonseok Chung et al. (2010), Amir Fam et al. (2010) has been investigated Behavior of Concrete- Filled FRP Tubes under Bending, Axial Loads, and Combined Loading, Aaron W. Malone (2010) has been investigated concrete filled steel tubular columns, a finite element study. This study focuses on the behavior of concrete-filled tubular (CFT) columns under combined axial load and bending moment, Hamdy M. Mohamed et al. (2011) has been investigated Deflection Prediction of Steel and FRP-Reinforced Concrete-Filled FRP Tube Beams. This paper presents the results of experimentaland theoretical investigations that study the flexural behavior of reinforced concretefilled fiber-reinforced polymer (FRP) tubes (RCFFTs) beams. SruthySagaran V is currently pursuing masters degree program in Structuralengineering in Calicut University, India, PH-9947574971. E- mail: sruthysagaranv@gmail.com Sruthi K Chandranis currently working asassistant professor in SIMAT Vavanoor, India, PH-9497100218. E-mail: sruthi.k@simat.ac.in TogayOzbakkaloglu et al. (2012) has been investigated Behavior of FRP-Confined Normal- and High- Concrete under Cyclic Axial Compression, Yilei Shi et al.(2013) has been investigated Assessment of Cyclic Behavior of Hybrid FRP Concrete Columns. Previous. experimental studies have shown superior performance of concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) under static or pseudostatic loading, TogayOzbakkaloglu (2013) has been investigated Concrete-Filled FRP Tubes Manufacture and Testing of New Forms Designed for Improved Performance. Chun-yang ZHU et al. (2013) has been investigated Mechanical behavior of concrete filled glass fiber reinforced polymer-steel tube under cyclic loading, Thomas Vincent et al. (2014) has been investigated Influence of Slenderness on Stress-Strain Behaviour of Concrete-Filled FRP Tubes: Experimental Study, Alicia Echevarria et al. (2015) has been investigated Residual Axial Capacity Comparison of CFFT and RC Bridge Columns after Fire. D.Asproneet al. (2015) has been investigated Behavior of Full-Scale Porous GFRP Barrier under Blast Load, Eric Jacques et al. (2015) has been investigated GFRP-Retrofitted Reinforced Concrete Columns Subjected to Simulated Blast Loading., Alicia Echevarria et al. (2015) has been developed Experimental Comparison of the Performance and Residual Capacity of CFFT and RC Bridge Columns Subjected to Blasts. YazanQasrawi et al.(2014) has been investigated Performance of Concrete-Filled FRP Tubes under Field Close-in Blast Loading.They concluded that CFFT specimens performed significantly better than the conventional reinforced specimens, showing greater robustness with decreased localized damage and reduced residual displacements. The objectives of the thesis are:

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 209 1. To develop a model that captures the dynamic behaviour of CFFTs under blast loads. 2. To conduct a comparison study of RC column and CFFT 3. To conduct a parametric study (ie, effect of standoff distance and charge weight) to further investigates the dynamic behaviour of CFFTs under blast loading. 5) GFRP Tube: ANSYS Autodyn allowed the entry of the GFRP tube s material properties in terms of the engineering constants. As the shell elements used to model the GFRP tube were two-dimensional elements, the through-thickness properties were omitted to achieve a plane stress situation. The Von Mises constitutive modelwas used to capture the GFRP tube s nonlinearity. 2 NUMERICAL MODELLING OF CFFT The dynamic response of CFFT subjected to blast loading is investigated by employing the hydrocode - Autodyn. Autodyn is an explicit analysis tool for modelling nonlinear dynamics of solids, fluids, gas, and their interaction. It is an integral part of the Ansys Workbench environment. 2.1 Model Description A CFFT of 4m long and outer diameter of 220mm including 5.5 mm thick GFRP, fixed support on two sides. The column is reinforced at a steel reinforcement ratio of 1.2% corresponding to four 11.65 mm diameter longitudinal bars. These steel reinforcement ratios approximated the 1 and 2.5% minimum and maximum recommended blast design reinforcement ratios to ensure strength and ductility. It contained 6-mm continuous steel spiral atspacing of the 0.1 m over the entire length with a reduced spacing of 0.05 m for 0.2 m from the ends over the supports. An equivalent charge weight of 50kg of C4 is used as explosive at a stand-off distance of 2 m from the surface of the column. 2.2 Material Models 1) C4 and TNT Explosives: The AnsysAutodynmaterial library s Jones-Wilkins-Lee (JWL) equation of state, which is predefined and already calibrated inansysautodyn by fitting to TNT explosives. 2) Air: AnsysAutodyn s ideal gas equation of state, included in the standard material was used to model the air in the blast. The air s internal energy was set to 2.068 10 5 J to correspond to standard atmospheric pressure and temperature. 3) Reinforcing Steel: The Johnson and Cook constitutive model, built into AnsysAutodyn, was used to capture the plastic flow of the reinforcing bars. The JC model represents the strength behaviour of materials subjected to large strains, high strain rates and high temperatures.the erosion strain was set to 0.1 to correspond to observations made during the tensile tests. 4) Concrete: RHT concrete constitutive model developed by Riedel, Hiermaier and Thoma, which is an advanced plasticity model for brittle materials, is used in the present numerical formulation. The RHT model is a combined plasticity and shear damage model and in this, the deviatoric stress is limited by a generalised failure surface. The RHT model is setup in ANSYS Autodynsuch that changing the concrete s compressive strength would automatically scale the remaining terms proportionately. Fig.1 AnsysAutodyn s model of CFFT TABLE 1 MATERIAL PARAMETERS Concrete Parameters P-α Reference density 2.4 g/cm 3 RHT concrete Shear modulus 1.67 10 7 kpa Compressive strength 3.4 10 4 kpa RHT concrete Tensile failure Principal stress Principal tensile failure stress 3.4 10 3 kpa Fracture energy 104.7 J/m 2 Strain.0035 GFRP Tube Ortho Reference density 1.938 g/cm 3 Young s modulus11 1.01 10 7 kpa Young s modulus22 2.16 10 7 kpa Poisson s ratio12 0.35 Shear modulus12 6.4 10 5 kpa Von Mises Shear modulus12 6.4 10 5 kpa

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 210 Yield stress 11 4.83 10 4 kpa Material strain Maximum deflection at Study Tensile failure strain11 0.0184 midspan(mm) Tensile failure strain22 0.0184 Experimental study [12] 20 AUTODYN 3D model Strain 0.02 (present) 23 Steel Parameters Linear The radius of the central C4 spheres was calculated using the experimental tests charge masses of Reference density 7.85 g/cm 3 50 and the density of C4 of 1,590 kg/m 3. The calculated Johnson Cook radii for the charges were 0.196 m for the 50 kg of C4 Shear modulus 7.69 10 7 kpa charge.25mm mesh for concrete was used to develop a Yield stress 4.3 10 5 kpa model. The maximum deflection observed in the present Hardening constant 2.57 10 5 kpa study is also compared with those documented in the Hardening exponent 0.26 literature and is found to be in good concordance (Table2). Plastic strain Therefore, the present numerical model can effectively Plastic strain 0.1 model the behaviour of CFFT under blast loading. Plastic strain Strain 0.1 3 RESULT AND DISCUSSIONS Air and C4 Parameters Reference density of air 0.001225 g/cm 3 The results of this study can be mainly included under 3 for air Ideal gas part such as the result of validation, the result of comparison of CFFT and reinforced concrete column Gamma 1.40 under blast loading and finally the result of parametric Reference density of C4 1.59 g/cm 3 study of CFFT under different charge weight and standoff for C4 JWL distance. Result of validation is already discussed above. 2.3 Validation Validation of the model that we developed is done 3.1 Comparison of CFFT and Reinforced Concrete according to YazanQasrawi et al. [12].AnsysAutodyn s Column sophisticated remapping capabilities were used to speed up the modeling time. The blast wave was initially Base model description of CFFT used for comparison and modeled using a two-dimensional (2D) axisymmetrical parametric study was different from validation. In this model from the explosion out to 1.975 m.when the blast case 10 mm diameter longitudinal bars and spacing of shockwave was within 25 mm from the column, the stirrups at 100mm throughout the length was used.the results of the 2D analysis was remapped into a sphere in remaining details were same as validation model. The the three-dimensional (3D) model. outer diameter of RC column is 209 mm. 80 mm mesh for concrete was used for the analysis. Because 25 mm mesh size was too difficult to analyse and its simulation time is also too large.50kg C4 explosive and 2m standoff distance is used for the analysis. Fig.2 Comparison of results in previous and current studies TABLE 2 The obtained results is given below in table 3, it can easily understand that the CFFT was more blast resilient than the RC column. There was about 67% variation in the displacement of RC column compared to CFFT. CFFT shows 33 mm deflection under 50 kg C4 explosive but at the same time RC Column shows 100mm deflection and damage to concrete was seen at the column after 25 ms. VALIDATION RESULT

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 211 Fig.3 Autodyn s displacement versus time graph of RC column TABLE 3 COMPARISON OF CFFT AND RC COLUMN *maximum deflection at midspan not attained within simulation time of 60 ms. Item Time(ms) Maximum deflection at midspan(mm) 3.2 Parametric Study Effect of Standoff Distance 3.3 Parametric Study Effect of Charge Weight TABLE 5 RC 25 100 EFFECT OF CHARGE WEIGHT Column CFFT 15 33 The failure of RC column under blast loading is clear from the graph given below (fig.3). In the case of CFFT there was no damage to concrete and there is only partial tear of the FRP material shows up to simulation time 60 ms. The addition of lateral confinement such as GFRP tube can reduce the concrete damage during blast loading. In both case there were no breakage of longitudinal and shear reinforcement. Parametric study of CFFT under 50 kg C4explosive and the standoff distance varying from 0.5 m to 2 m was done. It can be observed from table 4 that there is considerable effect of the variation of stand-off distance on the dynamic response of the CFFT and the midspan deflection reduced with the distance of explosive away from the CFFT. The simulation time was set as 60 ms. TABLE 4 EFFECT OF STAND OFF DISTANCE Parametric study of CFFT under 2 m standoff distance and the charge weight (C4) varying from 10 kg to 100 kg was done. It can be observed from the table 5 that there is considerable effect of the variation of charge weight on the dynamic response of the CFFT and the midspan deflection increased with the charge weight increment. The simulation time was set as 60 ms. 4 CONCLUSIONS In this study the dynamic behaviour of CFFT under 50 kg C4 explosive at a standoff distance of 2m has been

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016 212 investigated. The following conclusions are obtained from numerical investigations. 1. A model of CFFT developed using AnsysAutodyn to know the dynamic behaviour under blast loading. 2. Reinforced concrete specimen experienced concrete damage under blast loading. 3. The addition of lateral confinement such as GFRP tube can reduce the concrete damage during blast loading. 4. The 50 kg C4explosion at 2m standoff didn t break any lateral and shear reinforcement. 5. The midspan deflection reduced with the distance of explosive away from the CFFT. 6. The midspan deflection of CFFT is increased with the increment of charge weight. 5 RECOMMENDATIONS FOR FUTURE RESEARCH Recommendations for future research are as follows: 1. Study the influence of different parameters such as diameter and reinforcement percentage, etc.on blast loading by conducting the parametric study. 2. Formulation of design guide lines for blast loading on CFFT. [6] D. Asprone et al., Behaviour of Full-Scale Porous GFRP Barrier under Blast Loads,International Journal of Polymer Science.,2015. [7] Eric Jacques, GFRP-Retrofitted Reinforced Concrete Columns Subjected to Simulated Blast Loading. Journal of Structural Engineering, ASCE, 2015. [8] Hamdy M. Mohamed Deflection Prediction of Steel and FRP- Reinforced Concrete-Filled FRP Tube Beams,Journal of Composites for Construction, ASCE, Vol. 15, No. 3, June 1, 2011. [9] Thomas Vincent, Influence of Slenderness on Stress-Strain Behaviour of Concrete-Filled FRP Tubes: Experimental Study. Journal of Composites for Construction, ASCE,2014. [10] TogayOzbakkalogl, Concrete-Filled FRP Tubes: Manufacture and Testing of New Forms Designed for Improved Performance Journal of Composites for Construction, ASCE. Vol. 17, No. 2, April 1, 2013. [11] Wonseok Chung et al., Numerical and experimental investigation of concrete-filled FRP tube.international journal on FRP Composites in Civil Engineering., 2010. [12] YazanQasrawi et al Performance of Concrete-Filled FRP Tubes under Field Close-in Blast Loading,Journal of Structural Engineering, ASCE,2014. [13] Yilei Shi Assessment of Cyclic Behaviour of Hybrid FRP Concrete Columns, Journal of Bridge Engineering, ASCE.Vol. 18, No. 6, June 1, 2013. ACKNOWLEDGEMENT I am extremely thankful to our Principal Dr. A.K.Vasudevan for giving us his consent for this project. I am indebtly thankful to my thesis guide Er. SruthiK.Chandran, Assistant professor in civil engineering, for her constant help and support throughout the thesis work by providing timely advices and guidance. I am also thankful to God almighty for all the blessing received during this endeavor. Last, but not least I am also thankful to all our friends for the support and encouragement they have given me during this thesis work. REFERENCES [1] Aaron W. Malone, Concrete filled steel tubular columns, a finite element study. Journal of University of Massachusetts Amherst, 2010. [2] Alicia Echevarria et al, Experimental Comparison of the Performance and Residual Capacity of CFFT and RC Bridge Columns Subjected to Blasts, Journal of Bridge Engineering, ASCE, 2015 [3] Alicia Echevarria, Residual Axial Capacity Comparison of CFFT and RC Bridge Columns after Fire.journal of Polymers, 2015. [4] Amir Fam et al., Behaviour of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading, journal of NC State University, 2010. [5] Chun-yang Zhu Mechanical behavior of concrete filled glass fiber reinforced polymer-steel tube under cyclic loading, Journal of polymer,2013.