Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Similar documents
Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Application of Tensioned CFRP Strip Method to an Existing Bridge

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

PRELOADING EFFECT ON LOAD CAPACITY AND DUCTILITY OF RC BEAMS STRENGTHENED WITH PRESTRESSED CFRP STRIPS

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

Flexural Behaviour of External Reinforced Concrete Beams

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

CENTER FOR INFRASTRUCTURE ENGINEERING STUDIES

Tests on FRP-Concrete Bond Behaviour in the presence of Steel

Performance of NSM FRP strengthened concrete slabs at low temperatures

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

Effects Of Slenderness Ratio In RC Slender Column Using GFRP And CFRP Confinement

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

SHEAR PERFORMANCE OF EXISTING REINFORCED CONCRETE T-BEAMS STRENGTHENED WITH FRP

Sustainable Shear Behaviour of 2-Span Continuous Reinforced Concrete T-Beams with CFRP Strips

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

Behaviour of FRP wrapped circular reinforced concrete columns

GROUND ANCHOR TENDONS IN CARBON FIBRE-REINFORCED POLYMERS

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

Carbon fibre shear links for structural strengthening

Repair and upgrading of concrete structures with FRP materials

Construction. Carbon fiber shear links for structural strengthening. System Description. (Template for local translation, only for internal use)

Initial Tests of Kevlar Prestressed Timber Beams

EXPERIMENTAL ANALYSIS ON THE SHEAR BEHAVIOUR OF RC BEAMS STRENGTHENED WITH GFRP SHEETS

CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS

USE OF CFRP ANCHORS TO STRENGTHEN LAP SPLICES OF RECTANGULAR RC COLUMNS

Behavior and Strength of Bearing Wall Strengthening by CFRP

EXPERIMENTAL STUDY ON RC COLUMNS RETROFITTED BY FRP AND SUBJECTED TO SEISMIC LOADING

FUNDAMENTAL CHARACTERISTICS OF HIGH MODULUS CFRP MATERIALS FOR STRENGTHENING OF STEEL-CONCRETE COMPOSITE BEAMS

Flexural Performance of Reinforced Concrete Beams with a Layer of Expansive Strain-hardening Cement -based Composite(SHCC)

Bond Characteristics of GFRP Sheet on Strengthened Concrete Beams due to Flexural Loading

Moment curvature analysis of concrete flexural members confined with CFRP grids

Extreme Loading for Structures Version 3.1

Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

INNOVATIVE HYBRID WEARING SURFACES FOR FRP BRIDGE DECKS

Effect of FRP strengthening on the behavior of shear walls with opening

LOAD TEST EVALUATION OF FRP-STRENGTHENED STRUCTURES

Beam Pull Out Tests of NSM FRP and Steel Bars in Concrete

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

GFRP-STEEL HYBRID REINFORCED CONCRETE BRIDGE DECK SLABS IN QUEBEC, CANADA

DELAYING REINFORCED CONCRETE BEAM CRACKS USING CFRP (NUMERICAL MODELING)

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

Strengthening of prestressed concrete hollow-core slab openings using near-surface-mounted carbonfiber-reinforced

Strengthening Concrete Sections by FRP Materials

Fatigue and Overloading Behavior of Steel Concrete Composite Flexural Members Strengthened with High Modulus CFRP Materials

Structural health monitoring of structures repaired with FRP

Performance of Pretensioning Prestressed Concrete Beams with Ruptured Strands Flexurally Strengthened by CFRP Sheets

INNOVATIVE FIBRE REINFORCED BRIDGE DECK MODULES ABSTRACT

Bond performance of patching materials subjected to environmental effects

Upgrading Missouri Transportation Infrastructure: Solid RC Decks Strengthened with FRP Systems

SECTION 1 INTRODUCTION TO POST-TENSIONED CONCRETE DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

Structural Upgrade of Reinforced Concrete Column-Tie Beam Assembly using FRP Composites

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

Composite Beams of Cold Formed Steel Section and Concrete Slab

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

(FRP) ( CFRP

Flexural Behavior of Reinforced Concrete Beams Strengthened with CFRP Sheets and Epoxy Mortar

DESIGN GUIDELINES FOR BRIDGE DECK SLABS REINFORCED by CFRP and GFRP

STRENGTHENING OF MASONRY WITH NEAR SURFACE MOUNTED FRP BARS. Abstract

NONLINEAR FINITE ELEMENT ANALYSIS OF SHALLOW REINFORCED CONCRETE BEAMS USING SOLID65 ELEMENT

ZANCO Journal of Pure and Applied Sciences

Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

RC BEAMS STRENGTHENED WITH GFRP PLATES. I: EXPERIMENTAL STUDY

THE DESIGN OF EXTERNALLY BONDED REINFORCEMENT (EBR) FOR REINFORCED CONCRETE STRUCTURES BY MEANS OF FIBRE REINFORCED POLYMERS (FRP)

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

Shear Assessment and Strengthening of Contiguous-Beam Concrete Bridges Using FRP Bars

Finite Element Modelling of RC Beams Retrofitted with CFRP Fabrics

SEISMIC EFFECTS ON COUPLED SHEAR WALL STRUCTURE BY COUPLING BEAMS WITH SIDE BOLTED STEEL PLATES

On Finite Element Analysis of Steel and RC Beams : Performance of Different Elements

Executive Summary. Champlain Bridge Approach Spans Edge Girder Condition Assessment and Rehabilitation Requirements.

Influence of Arching Mechanism in Masonry Walls Strengthened with FRP Laminates

Applications of FRP Projects in Egypt

UHPC Connection of Precast Bridge Deck

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Strengthening steel bridges with new high modulus CFRP materials

Near Surface Mounted Reinforcement A. Palmieri, UGent

Strengthening of infilled RC frames by CFRP

The Hashemite University Department of Civil Engineering. Dr. Hazim Dwairi. Dr. Hazim Dwairi 1

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

1. INTRODUCTION. Fig.1 Dimension of test specimen

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

GFRP retrofitted RC frames with columns subjected to high axial stresses

SEISMIC STRENGTHENING OF A PRECAST REINFORCED CONCRETE WALL PANEL USING NSM-CFRP

ENGINEERING MATERIAL 100

Transcription:

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP) Abstract This paper presents the potential use of externally bonded fiber reinforced polymer (FPR) systems to upgrade reinforced concrete slabs deficient in flexural strength. A total of five slabs, each having 500 mm width, 125 mm thickness, and 1530 mm length, were cast and tested to failure under four-point bending. Two slabs were reinforced with three number of 10 mm tor steel bars at the tension side that corresponds to 0.38% steel reinforcement ratio. One slab was used as a control whilst the other slab was strengthened with fiber reinforced polymer (FRP). Other three slabs were reinforced with four numbers of 6 mm mild steel bars at the tension side that corresponds to 0.18% steel reinforcement ratio. One slab was used as a control specimen while the other two slabs were strengthened with different arrangement of fiber reinforced polymer (FRP). In the experimental stage, the influences of FRP on the slabs were analyzed by studying their behaviour at failure. Keywords: Flexural, Reinforced concrete slabs, Strengthening, Fiber reinforced polymer (FRP)

1. Introduction Strengthening of reinforced concrete (RC) structures is often required due to design stage errors, construction stage errors, inadequate maintenance, over loading at service stage, accidental damages and reduction of capacity due to aging and environmental effect. Some sort of a upgrading is required for those structures to overcome the problem. A large number of strengthening techniques are available in the world and are being used worldwide to overcome such problems. Some of the commonly used strengthening techniques are section enlargement, steel plate bonding, sprayed concrete, jacketing method, external post tensioning, Fiber Reinforced Polymer (FRP) bonding. Although these techniques can effectively increase the element s load carrying capacity, they are often susceptible to corrosion damage, which results in failure of the strengthening system. According to Tamer EM and Khaled S (2008), among those, the application of Fiber Reinforced Polymer (FRP) is a non-corrosive innovative strengthening system, which has the potential for extending service lives of RC structures and reducing maintenance costs. Fiber Reinforced Polymer (FRP) can be used for the strengthening or retrofitting of existing concrete structures to resist higher design loads, correct deterioration-related damage. According to Tarek HA and Yousef AS (2001), repair with externally bonded FRP reinforcement is a highly practical strengthening system, because of ease and speed of installation, efficiency of the structural repair and corrosion resistance of the materials. The application of FRP creates minimal modification to the geometry, aesthetics and utility of the structure. Several studies on the behaviour of reinforced concrete slabs strengthened with FRP composite sheets provided valuable information regarding the strength, deformation, ductility and long-term performance of the FRP strengthening systems. Accoring to Sujeeva S (2002), the advantages of using FRP include lightweight, ease of installation, minimal labour costs, higher strength-to-weight ratio, higher stiffness-to-weight ratio, higher corrosion resistance and durability. This paper presents the potential use of externally bonded fiber reinforced polymer (FPR) systems to upgrade reinforced concrete slabs deficient in flexural strength. This aims a confirmation to the effectiveness of using FRP in repair and rehabilitation of reinforced concrete slabs. 2. Experimental study Experimental investigation was carried out on five slab specimens reinforced with tor steel bars (f y = 460 N/mm 2 ), mild steel bars (f y = 250 N/mm 2 ) and different arrangement of fiber reinforced polymer (FRP). The specimens were tested under four point bending.

2.1 Slab specimens In the Experimental program five slabs of length 1530mm, and a cross-section of 500mm width 125mm depth were cast with two types of steel bars. The clear span was 1350 mm. Three slabs were singly reinforced at tension side by four numbers of 6 mm mild steel bars and the other two slabs were singly reinforced at tension side by three numbers of 10 mm tor steel bars with a concrete clear cover of 25 mm. This corresponded to a steel reinforcement ratio of about 0.18% and 0.38% respectively. For the strengthened slabs, Carbon Fiber Reinforced Polymer (CFRP) strips having a width of 200 mm and a thickness of 1 mm was bonded to the tension face of the slab with two different arrangements (TS1 & TS2), which corresponded to a CFRP reinforcement ratio of about 0.32% and 0.64%. Figure 1 shows a schematic of a typical test specimen with loading arrangement. W/2 W/2 Dial gauges on both sides 90mm 450mm 450mm 450mm Figure 1: Slab loading pattern 90mm 500 mm 125 mm 200 mm Figure 2: T10 TS1 Cross section 500 mm 1-Layer TYFO SCH41 Carbon Strip 200mm wide. 125 mm 200 mm 1-Layer TYFO SCH41 Carbon Strip 200mm wide. Figure 3: R6 TS1 Cross section

500 mm 125 mm 200 mm 200 mm 50 mm 1-Layer TYFO SCH41 Carbon Strips 200mm wide each Figure 4: R6 TS2 Cross section 2.2 Test matrix The test matrix is given in Table 1. A total of five slabs were used in the present study. Two slabs were used as control specimens whilst the other three slabs were strengthened with CFRP strips as follows. As the first arrangement, one CFRP strip bonded to centre of tension face of the slabs, had 10 mm tor steel bars and 6 mm mild steel bars. As the second arrangement, two strips of CFRP bonded to tension face of the slab, had 6 mm mild steel bars. Table 1: Test Matrix Specimen Longitudinal Reinforcement No. of CFRP strips CFRP Reinforcement Ratio (%) T10 Control 3 T10 @ 225mm -- -- T10 TS1 3 T10 @ 225mm 1 0.32 R6 Control 4 R6 @ 175mm -- -- R 6 TS1 4 R6 @ 175mm 1 0.32 R 6 TS2 4 R6 @ 175mm 2 0.64 2.3 Material properties All the slabs were cast with normal weight concrete with a maximum aggregate size of 18 mm. The concrete had an average compressive strength of 38 N/mm 2 and modulus of elasticity of 29 kn/mm 2 at the time of testing. A concrete cover of 25 mm was used for the main reinforcement. The characteristic strength of tor and mild steel reinforcement was 460MPa and 250MPa, respectively. The CFRP strip was TYFO SCH41 Carbon Strip. Properties of CFRP composite strips and the Epoxy are given in Table 2 and Table 3.

Table 2: Specifications of CFRP Table 3: Specifications of Epoxy Material Typical dry fiber properties Properties Typical Test Values Tensile Strength 3.79 GPa UTS 72.4 MPa Tensile Modulus 230 GPa Tensile Modulus 3.18GPa Ultimate Elongation 1.7% Elongation Percentage 5.0% Density 1.74 g/cm3 Flexural Strength 123.4 MPa Weight per sq.yd. 644 g/m2 Flexural Modulus 3.12 GPa 2.4 Test set-up and instrumentation All slabs were tested under four-point bending with an effective span of 1350 mm as shown in Figure 1. Load was applied monotonically at the mid-span of the slab using a hydraulic jack and a proving ring having a capacity of 100 kn. A spreader plate was used to transfer the load to the slab through two loading points placed at the ends of the middle third of the slab span. The slab was supported on two steel rods, 1350 mm apart on centre. Two dial gauges were placed on the mid-points of both longitudinal directions on the top surface, mid span of the slab to measure the deflection while a calibrated load cell was used to record the load. Two strain gauges, each of 30 mm length, were bonded to the surface of the CFRP strip at the mid-span and concrete at the top face at the mid-span of the slab. Figure 5 shows a photograph of the test arrangement. Dial gauges Figure 5: Test arrangement

2.5 Test results and discussions 2.5.1 Mode of failure The control slabs exhibited a conventional ductile flexural mode of failure in which the slabs failed by crushing of concrete. Specimens T10 TS1, R6 TS1 and R6 TS2 strengthened with CFRP failed prematurely without warning by debonding of CFRP laminates. 2.5.2 Load CFRP strain relationship Figure 6: Load versus CFRP strain at mid-span relationship. The load versus CFRP strain at mid-span section relationships are shown in Figure 6. The load versus mid-span CFRP strain relationships for specimens R6-TS2-A and R6-TS2-B were identical. All the values were less than it ultimate CFRP strain value of 0.017.Therefore there were no CFRP material failure occurrence.

2.5.3 Load deflection relationship The load versus mid-span deflection relationships for all specimens is shown in Figure 7 while Table 4 summarizes the structural test results and increments of the load carrying capacity of strengthen slabs. Table 4: Test results Experimental Values Specimen P u (kn) u (mm) Mode of failure Increment of the load carrying capacity (%) T10-CS 29.17 5.68 Concrete crushing --- T10-TS1 82.16 13.95 CFRP debonding [(82.16-29.17)/29.17] 100 = 181.66 R6-CS 18.24 1.30 Concrete Crushing --- R6-TS1 48.56 8.90 CFRP debonding [(48.56-18.24)/18.24] 100 = 166.22 R6-TS2 85.61 8.66 CFRP debonding [(85.61-18.24)/18.24] 100 = 369.30 P y and P u refer to yield and ultimate loads, respectively. y and u refer to mid-span deflections at yield and ultimate loads, respectively. Figure 7: Load versus mid-span deflection relationship.

CFRP bonding improves the ductility of the slabs effectively. The ultimate load of specimen T10-TS1 was about 181.7% higher than that of control. Specimen T10-TS1 failed by intermediate crack induced debonding of the CFRP strip. The strengthening with CFRP greatly increased the load carrying capacity of the slabs. The ultimate load of specimen R6-TS1, which was strengthened with with one strip of CFRP along with span, was about 166.2% higher than that of control specimen R6-CS. The ultimate load of specimen R6-TS2, which was strengthened with two strips of CFRP along with span, was about 369.3% higher than that of control specimen R6-CS. The slabs strengthened with higher percentage of CFRP had higher ultimate load carrying capacity relative to those of the control. 3. Conclusion A simple and efficient, experimental procedure to predict the nominal moment capacity of RC slabs strengthened with external CFRP laminates was presented. The experimental results of a series of slab strengthened with a different number of layers of CFRP were also presented. From the results obtained following conclusions can be drawn: The experimental study indicated that the strengthened specimens failure mode was Intermediate crack induced debonding failure due to stress concentration. CFRP bonding improves the ductility of the slabs. The test results indicated that a significant gain in flexural strength can be achieved by bonding CFRP laminates to the tension face of RC slabs. The use of CFRP laminates as an external reinforcement to strengthen and upgrade concrete structural members proved to be efficient.

References Tamer, EM and Khaled, S (2008), "Strengthening of reinforced concrete slabs with mechanically-anchored unbonded FRP system," Construction and Building Materials, vol. 22, no. 4, pp. 444-455. Tarek, HA and Yousef, AS (2001), "Ultimate strength predictionfor RC beams externally strengthened by composite materials composite materials," composites Part B: engineering, vol. 32, pp. 609-619. Sujeeva, S (2002), "User Friendly Guide for Rehabilitation or Strengthening of Bridge Structures Using Reinforced Polymer Composites," CRC Construction Innovation.