Top reasons to upgrade to a Q Exactive HF-X hybrid quadrupole-orbitrap mass spectrometer

Similar documents
High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct.

Thermo Scientific TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative performance. with unprecedented ease

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

Key Words Q Exactive Focus, SIEVE Software, Biomarker, Discovery, Metabolomics

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

LTQ Orbitrap XL Hybrid FT Mass Spectrometer Unrivaled Performance and Flexibility

LC/MS/MS Solutions for Biomarker Discovery QSTAR. Elite Hybrid LC/MS/MS System. More performance, more reliability, more answers

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

Liver Mitochondria Proteomics Employing High-Resolution MS Technology

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Agilent 6430 Triple Quadrupole LC/MS System

Thermo Scientific Proteomics & Metabolomics Seminar Tour

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

performance and throughput

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

UFFLC of the Proteome Ultra High Pressure and Ultra Fast Flow Liquid Chromatography: A New Approach To Proteomics

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

The clearly better choice

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc

Using HRAM Survey Analysis Combined with Rapid MS2 Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

MetaboScape 2.0. Innovation with Integrity. Quickly Discover Metabolite Biomarkers and Use Pathway Mapping to Set them in a Biological Context

Thermo Scientific TSQ Quantum Access MAX

Elute LC series. Innovation with Integrity. UHPLC Precision for MS applications LC-MS

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778)

Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Application Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona

ICP Expert software. Technical Overview. Introduction

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

CaptiveSpray nanobooster

TurboMass GC/MS Software

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Agilent solutions for contract research and manufacturing organizations

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

QUANLYNX APPLICATION MANAGER

BÜCHI Labortechnik AG

Agilent InfinityLab LC/MSD Series EXTEND THE BOUNDARIES OF YOUR ANALYSIS

Advanced QA/QC characterization MS in QC : Multi Attribute Method

Peptide Mapping: A Quality by Design (QbD) Approach

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Pharmaceutical LC/MS Solutions from Agilent Technologies

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

High-Throughput Peptide Mapping with the Vanquish UHPLC System and the Q Exactive HF Mass Spectrometer

NovoCyte Flow Cytometer

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

The Five Key Elements of a Successful Metabolomics Study

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

faster, confident more path to all the information in your samples. Agilent MassHunter Workstation Software Our measure is your success.

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

Increasing MS Sensitivity for Proteomics

HPLC/FLASH Purification ADVANCE THE PACE OF YOUR DISCOVERY TO ACHIEVE THE RESULTS OF TOMORROW

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

PESTICIDE SCREENING APPLICATION SOLUTION

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Agilent 6500 Series Q-TOF LC/MS System

SMART Digest Kit User Manual. Version 2

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

Agilent 6400 Series. System. Concepts Guide. The Big Picture. Agilent Technologies

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

HDX-MS at Waters Waters Corporation 1

The Effect of MS/MS Fragment Ion Mass Accuracy on Peptide Identification in Shotgun Proteomics

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Application Note. Authors. Abstract

Transcription:

GRANT APPLICATION RESOURCE QExactive HF-X hybrid quadrupole-orbitrap mass spectrometer Top reasons to upgrade to a HF-X hybrid quadrupole-orbitrap mass spectrometer Keywords Proteomics, protein identification, protein ID, protein quantiation, relative quantitation, protein multiplexing, TMT, high throughput mass spectrometry, MS, Plus MS, HF MS, HF-X MS, BioPharma Option, monoclonal antibodies Goal This document is intended to address the technical and workflow benefits of using the HF-X mass spectrometer (MS) system, specifically providing conclusive arguments for laboratories looking to enhance their MS capabilities to an advanced hybrid quadrupole-orbitrap mass spectrometer. Summary Understanding biomolecules as drug targets, disease markers, and therapeutic agents demands highly sensitive analysis of complex biological samples, without sacrificing robustness and speed. The Thermo Scientific HF-X hybrid quadrupole-orbitrap mass spectrometer rises to the challenge as a versatile platform, setting new standards in sensitivity, performance and productivity for any workflow. Building on the proven performance of the Thermo Scientific hybrid quadrupole- Orbitrap MS family of instruments, the new HF-X mass spectrometer couples a high field Thermo Scientific Orbitrap mass analyzer with a high capacity transfer tube and electrodynamic ion funnel that together maximize ion loading and transmit ions over a broad mass range. As a result, the instrument delivers a bright, focused and ion-rich beam, which translates to high sensitivity and excellent stability in analysis quality from run to run. Smart instrument control features match the superior ion transmission with increased acquisition speed and even more sophisticated data-dependent acquisition and analysis strategies to meet data quality needs at every stage of your work, from discovery to verification to quantitation.

Introduction The Thermo Scientific HF-X mass spectrometer is the latest and most advanced MS instrument in the MS product portfolio. Orbitrap mass analyzer-based mass spectrometers have been well known for high resolution and accurate mass detection capabilities. Benchtop MS instruments are widely used by many laboratories and have evolved into a proteomics analysis workhorse, being highly versatile for multiple proteomics applications and workflows, be they qualitative or quantitative. Researchers constantly face issues with sample complexities and dynamic range, which cannot be addressed fully by up-front fractionation or optimal chromatographic resolution alone. In trying to resolve these problems (e.g., abundance differences of peptides), it is imperative that mass spectrometric technologies be refined in terms of scan speeds, resolution and sensitivity. The release of the HF-X MS introduced several proven hardware innovations and novel acquisition methods driven by instrument control improvements implemented on this platform. These features are targeted towards increasing experimental efficiency, providing multiple modes of analysis and addressing common analytical challenges associated with highly complex, low abundant or challenging samples, while improving ease of instrument operations for MS users. Aimed at comprehensive analysis of proteins present in complex biological samples, the HF-X MS is a breakthrough, as well as an essential MS tool for discovery proteomics, translational research, precision medicine and clinical applications. Hardware benefits The HF-X MS has the following capabilities: Consistency in analytical performance to achieve quantitative accuracy and reproducibility with uncompromised sensitivity for highly rigorous research workflows, suited for large-scale studies involving challenging sample types Improved scan rates up to 4 Hz for faster scan acquisitions allowing for increased instrument throughput and productivity New intelligent data-dependent acquisition workflow for intact proteins that facilitates deeper insights from topdown proteomics Parallel reaction monitoring (PRM) and high-resolution data-independent acquisition (HR-DIA) modes, providing flexibility and delivering robust workflows for all quantitative experimental needs The HF-X MS is equipped with the following: Novel architecture with a high capacity transfer tube (HCTT) and electrodynamic ion funnel that increases ion transmission and boosts sensitivity for all analytes, from small molecules to native antibodies Advanced Quadrupole Technology (AQT) that enhances selectivity in precursor isolation and improvement of transmission at narrow isolation widths Advanced Active Beam Guide (AABG) for greater sensitivity and maximum robustness Advanced Peak Determination (APD) feature coupled with increased acquisition speed dramatically increases peptide sequencing speed and coverage depth A C-trap that stores and compresses ion populations before injection into the ultra-high field Orbitrap mass analyzer Ultra-high field Orbitrap mass analyzer providing resolution at 24, FWHM at m/z 2 and scan speeds up to 4 Hz at 7,5 FWHM at m/z 2 In previous generations of hybrid Orbitrap mass spectrometers (e.g., Thermo Scientific Orbitrap Velos and Orbitrap Elite MS), precursor selection and fragmentation typically occurred in a linear ion trap. For these MS systems, the linear ion trap provided sufficient MS/MS scan rates for most qualitative proteomics experiments. However, as the MS community evolved to seek quantitative information, faster acquisition rates, faster chromatographic separations and higher sample throughputs became the basic requirements for routine quantitative analysis. 1 The combination of a quadrupole mass filter with an Orbitrap mass analyzer provides a configuration for virtually instantaneous ion selection along with similarly fast Higher-energy Collisional Dissociation (HCD) fragmentation, to satisfy the requirements of speed and sensitivity. 2

Figure 1. Hardware schematic of the HF-X MS. HyperQuad Mass Filter with Advanced Quadrupole Technology (AQT) Electrodynamic Ion Funnel C-Trap Advanced Active Beam Guide (AABG) HCD Cell Ultra High Field Orbitrap Mass Analyzer High Capacity Transfer Tube Table 1. Fundamental features and benefits of hybrid quadrupole-orbitrap MS technology. Features Ultra-High Resolution Sub ppm Mass Accuracy Optimized Scan Matrix Speed Easy-to-Use Software Experimental Flexibility Benefits High resolving power for confident structural confirmation High selectivity and confidence in molecular formula Improved transient times advantageous for efficient, high quality MS/MS acquisitions Faster scan rates for improving protein identification rates, achieving quantitation accuracy Build complex methods using the intuitive method editor DDA, DDA+, PRM, HR-DIA acquisition modes Key improvements have been made to various hardware components on the HF-X mass spectrometer to give enhanced analytical performance: Novel front-end architecture similar to the proven high-end research grade Thermo Scientific Orbitrap Fusion Lumos Tribrid mass spectrometer and highend triple quadrupole Thermo Scientific TSQ series mass spectrometers to provide increased sensitivity. The ion source is comprised of the High Capacity Transfer Tube (HCTT) and Electrodynamic Ion Funnel (EDIF) to achieve better ion transmission, ion stability and reach lower limits of detection ranging from small molecule analytes to native antibodies. Accelerated Higher-Energy Collisional Dissociation (ahcd) enables faster MS/MS acquisition and compatibility with capillary-flow rates, producing reliable and high quality MS 2 spectra Table 2. Specifications. Features HF-X MS Resolution 24, (FWHM) at m/z 2 Mass Range 5 to 6, m/z (up to 8, m/z)* Scan Rate Up to 4 Hz at resolution setting of 7,5 at m/z 2 Quad Isolation Down to.4 Da Mass Accuracy <3 ppm RMS (external); <1 ppm RMS (internal) Dissociation Source CID, HCD Multiplexing Up to 1 precursors/scan Polarity Switching Sensitivity One full cycle in <1 sec (one full positive mode scan and one full negative mode scan at resolution setting of 6,) MS/MS: 1 fg reserpine on column S/N 15:1; SIM 5 fg reserpine on column S/N 15:1 Dynamic Range >5,:1 Scan Functions Full Scan (FS), All Ion Fragmentation (AIF), Selected Ion Monitoring (SIM), Parallel Reaction Monitoring (PRM), Data Independent Acquisition (DIA), data dependent HCD (ddhcd) *With BioPharma option Detailed product specifications for the HF-X MS can be found on www.thermofisher.com. For sole source specifications, kindly contact your local sales representative or contact us at Grant Central. 3

Experimental benefits of the HF-X MS Analytical robustness for routine applications, delivering reproducibility and high throughput High-resolution accurate-mass and sensitivity Fast scan speeds for shorter gradient times Highest data quality, in comparison with QTOFs Innovative instrument control features enable unrivaled data-dependent performance the shortest possible time, driving the need for improved on-the-fly spectral analysis and peak assignment. The APD algorithm fulfills this need by identifying the charge states and monoisotopic m/z values of isotopic envelopes at greatly improved peak depths in complex MS spectra (Figure 2). For conventional bottom-up shotgun experiments of complex proteomes, this algorithm dramatically increases the population of precursors available for data-dependent analysis, which in turn results in more MS/MS spectra, PSMs and unique peptide identifications. Push the limits of discovery proteomics with faster and deeper sequencing Empowers standardized label-free quantification workflows, providing robust and reproducible results for translational proteomics studies Reason 1: Innovative instrument control features enable unrivaled data-dependent performance The HF-X MS is equipped with a suite of novel instrument control optimizations permitting improved precursor selection, more efficient scanning matrices and faster Orbitrap mass analyzer acquisition speeds. Collectively, the following innovations ultimately allow superior sensitivity and productivity to meet the demands at various experimental stages (from discovery, to verification and quantitation), throughput levels and depth of analysis, regardless of your application. Advanced Peak Determination (APD) Traditional data-dependent MS acquisition relies on robust and accurate ion charge determination as the first step to initiate MS n analysis and allow molecular identification. Conventional versions of peak detection algorithms have significant limitations including inefficient identification of all isotopic clusters in a complex spectrum, limited identification of adjacent or overlapping isotopic clusters, and an inability to assign poorly resolved spectra. FTMS MS 1 scans have been shown to contain many more precursors than what is typically selected for MS/MS during a data-dependent run. This is due to limited scan rates and sensitivity on legacy MS systems impacting the number of MS/ MS events triggered. Today, higher performance mass spectrometers like the Orbitrap Fusion Lumos Tribrid MS and HF-X MS, are engineered with extreme sensitivity and resolution, and can generate high quality MS/MS spectra from low signal-to-noise components in Standard Peak Determination Advanced Peak Determination Figure 2. Enhancements to on-the-fly charge state detection leads to the identification of more precursor candidates in complex spectra resulting in more data-dependent triggers in proteomics samples, and higher number of identifications. While providing an obvious advantage to complex bottom-up sample analysis, APD can benefit other applications in an equal manner. Top-down analysis of intact molecules is often complicated by complex charge envelope profiles, resulting in redundant fragmentation events that ultimately limit the dynamic range of identification and result in incomplete characterization of proteins in a sample. Utilizing the Protein Mode within the BioPharma option, top-down workflows will benefit from APD s ability to perform real-time, robust charge state assignments of unresolved or resolved intact proteins. In addition, smart APD algorithms automatically select the dominant charge proteoform along with optimal collision energy for the fragmentation of each selected precursor to achieve complete and confident identification of proteins in the sample (Figure 3). 4

On-the-fly deconvolution based on charge envelope to select a single charge state of each dominant proteoform. MS/MS analysis of each proteoform fragmented with optimal collision energy and detected at a resolution setting of 12,. Relative Abundance 1 8 6 4 2 588.5 z=44 631.5 z=41 673. z=19 696.5 z=32 742.8 z=3 752.1 z=17 857. z=26 891.3 z=25 968.7 z=23 112.7 z=22 1172.3 z=19 1237.5 z=18 131.3 z=17 5 6 7 8 9 1 11 12 13 14 m/z post acquisition Relative Intensity 1 8 6 4 2 699.7 z=37 T: FTMS + p ESI d Full ms2 742.8353@hcd3. [2.-8.] 798.11 R=6836 z=15 1 Relative Abundance 8 6 4 2 58.63 R=8586 z=3 748.29 R=796 z=16 811.58 T: FTMS + p ESI d Full ms2 752.58@hcd3. R=6586 [2.-8.] 687.55 735.41 z=15 R=7616 R=756 87.66 z=7 1 z=16 R=6386 73.33 z=11 95.11 R=756 756.72 R=686 8 z=17 R=7236 z=8 z=7 754.29 66 5 7R=7236 8 9 z=7m/z 81.98 872.47 R=746 R=6696 4 z=6 z=8 677.41 T: FTMS + p ESI d Full ms2 699.6851@hcd3. [2.-8.] R=7586 711.67 92.74 z=7 R=7256 R=6446 762.44 997.11 2 z=8 z=15 R=786 1 R=5996 z=14 z=7 Deconvolution with Respect 8 22256.3 6 7 8 9 691.57 1 12767.8 15 2 25 Mass 2585.8 Relative Abundance Relative Abundance 6 4 2 495.69 R=8346 z=5 MS/MS Proteoform 1 m/z 559.8 R=7856 z=4 61.6 R=886 z=4 R=7326 z=22 667.2 R=7316 z=16 MS/MS Proteoform 2 813.39 R=6516 z=13 MS/MS Proteoform 3 5 6 7 8 9 m/z Figure 3. APD facilitates improved top-down analysis in an intact protein mixture. Separation of a mixture of E.coli ribosomal proteins using a 4 min method, 7,5 resolution setting on the HF-X MS can be achieved with confident deconvolution of the charge envelope and selection of a single charge state for each dominant proteoform (shown for 3 proteoforms in the mixture). Optimized Scan Matrix and Accelerated Higher- Energy Collisional Dissociation (ahcd) With the HF-X MS, we introduce a 16 ms transient length to allow up to a 4 Hz scan rate at 7,5 resolution. In addition, the reduction of inter-scan and intra-scan overhead times deliver an extra 1 ms ion injection time (IT) into the Orbitrap mass analyzer in MS/MS mode for the 16 ms transient (Figure 4). This modified ahcd timing maximizes ion accumulation time within a shorter transient time and ensures the highest MS 2 spectral quality even at rapid 4 Hz scan rates. This is demonstrated in a triplicate analysis where a HeLa cell digest ran on the Thermo Scientific HF hybrid quadrupole-orbitrap mass spectrometer and HF-X MS at two different MS 2 resolution settings of 15, and 7,5 respectively (Figure 5). From the peptide score distribution (>8, peptides), the HF-X MS clearly achieves the perfect balance between resolution and reliable MS 2 spectra without sacrificing spectral quality. Thus, the Orbitrap mass analyzer delivers the same high-quality, high-confidence data but at roughly twice the scan rate of previous MS platforms. Q-Exactive HF MS 15K MaxIT 32 ms Q-Exactive HF-X MS 7.5K 16 ms Max IT 4 Hz 18 Hz Reduced scan timing and ahcd allows similar maxit at 7.5K Orbitrap analyzer detection Maximum ion fill time Scan overhead time Figure 4. Optimized Protein scan matrix Precursors now enables (1% a novel FDR) 7,5 resolution Orbitrap mass analyzer setting for maximal scanning speed. 5

Figure 5. Maximal productivity can be achieved with the new 7,5 resolution setting while still retaining highest data quality. To highlight the performance benefit of these features with respect to a bottom-up analysis, 1 µg of HeLa cell line digest was analyzed on the HF-X MS using the 7,5 resolution setting under various LC gradient durations. This same experiment was also performed on the HF MS at 15, resolution. The short 16 ms transient time combined with ahcd resulted in the detection and identification of ~1,1 peptides per minute under conditions where sample complexity is maximal. Identification of more unique peptides on the HF-X MS is especially evident at shorter gradient times. This highlights the potential to maximize insights from your peptide ID experiments, by improving productivity without sacrificing data quality (Figure 6). Number of Unique Peptides Per Minute 12 1 8 6 4 2 Suitable transient length for maximal productivity High confidence spectra at 7,5 resolution HF MS HF-X MS -5-4 -3-2 -1 1 Normalized peptide score distribution (Ln) HF MS, (15k) HF-X MS, (7.5k) Reason 2: Push the limits of discovery proteomics with faster and deeper sequencing Basic research as well as biomedical studies increasingly rely on advanced technology for rapid, wide scale, comparative analysis of proteomes. Taking proteomics discovery to the next level of insight and productivity requires innovative advances in MS technology. The HF-X MS sets new standards in speed and sensitivity building on the well-known Orbitrap mass analyzer attributes of providing the highest confidence and selectivity. Deep proteome analysis should be completed in hours rather than days. The new HF-X MS is faster and has improved sensitivity with the enhanced HCTT and EDIF front-end design architecture, allowing you to probe deeper and more efficiently. The HF-X mass spectrometer boosts productivity in protein identification, while maintaining the proven mass accuracy of the high field Orbitrap mass analyzer. Superior ion transmission, together with ahcd and new scan rates up to 4 Hz, drive more efficient use of the Orbitrap mass analyzer. The same, or better, protein identifications in half the analysis time HeLa cell line digest was analyzed in triplicate using a 3-minute liquid chromatographic (LC) separation on the HF-X MS and a 6 minute LC separation on both a HF MS and MS. Almost the same number of protein groups were identified on the HF-X MS in half the time, achieving a nearly 2-fold improvement in analysis time as the previous generation instrument. Users with past experiences using previous generation series mass spectrometers can perform the same experiments in half the time and expect to obtain even more significant data than before (Figure 7). The faster scan rates on this instrument, while preserving spectral quality, present a tremendous potential throughput advantage for large-scale proteomic studies as the productivity in large-cohort analyses can be effectively doubled. Such an improvement is beneficial for labs that have limited instrument access time to accommodate increasing sample quantities and drive experimental efficiency. 7.5 15 3 6 Gradient Length (min, log scale) 6 Figure 6. The HF-X MS delivers rapid, deep proteome sequencing results with maximal productivity. Data provided courtesy of Jesper Olsen. 2

MS, 6 min HF MS, 6 min HF-X MS, 3 min 2,638 4,83 3,831 Almost the same data in half the time 45% more data in half the time Protein Groups Figure 7. Proteins identified faster than ever. To further illustrate the improved identification efficiency for peptide sequencing shotgun experiments, Jesper Olsen s group at the University of Copenhagen performed an analysis of in-depth proteome profiling of HeLa cell line using a typical offline peptide fractionation scheme followed by analysis on the HF-X MS. This experiment provided the ultimate performance test of this instrument and the results from this deep proteome sequencing study were overlaid with previously published data collected on a HF MS using comparable acquisitions settings. 3 Impressively, the enhanced speed of the HF-X MS produced over 8, protein identifications in less than half the time and with fewer fractions than their previous best analysis (Figure 8). In addition, proteins from the first fraction alone contained approximately 5% of proteins found across all fractions which could prove useful for experiments where maximal protein annotation needs to be achieved in the shortest amount of time. Increased peptide ID efficiency Figure 8. Deep proteome fractionation studies are completed in 5% less time. Data with courtesy from J. Olsen, Novo Nordisk Foundation, Center for Protein Research, University of Copenhagen. 2 In certain scenarios, productivity is not the key analytical criteria, but rather depth of insight is desired. Studies involving PTM analysis, deep proteome investigation, or spectral library building can benefit from the advanced technology of the HF-X MS. To evaluate the efficiency potential of the HF-X MS, 1 µg of HeLa cell line digest was analyzed in triplicate on the HF-X MS, HF MS and MS systems. A 6-minute LC separation was used on all systems. Results show that the HF-X MS identified significantly more unique peptides in the same amount of time, resulting in improved proteome depth and protein coverage (Figure 9A). Alternatively, with significantly more unique peptide identifications per unit time, you can shorten your time-to-results at any throughput scale and at any depth of analysis (Figure 9B 6 min vs 3 min). A MS, 6 min HF MS, 6 min HF-X MS, 6 min 32,45 B MS, 6 min HF MS, 6 min HF-X MS, 3 min 26,533 22,959 22,959 16,431 ~4% more peptide IDs in same amount of time 16,431 ~16% more data in half the time ~95% more peptide IDs in same amount of time ~6% more data in half the time 7 Peptides Peptides Figure 9. Increased peptide ID efficiency with the HF-X MS allows improved depth and coverage (A) or higher productivity to be achieved (B).

Reason 3: The HF-X MS empowers standardized label-free quantification workflows, providing robust and reproducible results for translational proteomics studies Precision medicine and translational proteomics studies require implementation of highly robust analytical platforms to deliver accurate and reproducible peptide/ protein quantitation, along with productive throughput. Verification of protein biomarkers requires confident quantitation of low-level proteins in large cohort studies. To this end, the superior consistency and performance of the HF-X MS sets new standards in quantitative accuracy, sensitivity and reproducibility for rigorous research workflows in large-scale studies of challenging protein samples. Label-free precursor ionbased MS 1 quantitation is a proven approach, delivering confident and reliable protein measurements. New DDA+ and HR-DIA workflows for label-free quantitation eliminate missing values across samples, delivering reproducibility and precision for large sample cohorts. DDA+ is a new label-free quantitation workflow on the HF-X MS optimized for analytical robustness and reproducible precursor-based protein quantitation when the highest level of data precision is required. In traditional data-dependent workflows, consistent precursor and thereby protein quantitation can be challenging to achieve due to the stochastic sampling nature of the mass spectrometer. Since a subset of all possible precursor ions is selected for fragmentation and subsequent identification, reliable and consistent precursor quantitation is routinely accomplished for only a fraction of proteins in a sample. The remaining unselected precursors, and proteins by extension, are undetected and unquantified even if they were in fact present within the sample. This creates limitations for experiments where researchers want to compare protein levels across many samples, such as biomarker discovery and validation studies, because data for some proteins will be missing in some samples, leading to poor reproducibility and the so-called missing value problem. The newly developed DDA+ quantitation workflow addresses this limitation by providing a sensitive, standardized, robust approach for all stages of the analytical process. DDA+ builds on the proven, trusted approach of datadependent MS acquisition and database-mediated identification utilized in peptide ID studies and applies the necessary analytical components to facilitate reproducible precursor-based protein quantitation. The DDA+ workflow leverages the capillary-flow Thermo Scientific UltiMate 3 RSLCnano system and new 15 µm I.D. Thermo Scientific EASY-Spray columns in combination with the performance attributes of the nextgeneration HF-X MS to maximize robustness and up-time without sacrificing sensitivity (Figure 1). The UltiMate 3 RSLCnano capillary-flow solution with direct flow-control delivers application versatility ideal for high-throughput large-sample cohort discovery profiling (3 5 µl/min flow rate) as well as highly sensitive, targeted validation experiments (1.2 µl/min flow rate). The integrated microflow loading pump permits fast sample loading and column washing at increased flow rates whether operating in pre-concentration or direct inject mode. Robust LC Separation Optimized MS Acquisition Comprehensive Data Informatics UltiMate 3 RSLCnano system 15 µm EASY-Spray columns HF-X MS Proteome Discoverer software Figure 1. DDA+ provides a standardized, robust, sensitive solution for label-free quantitation. 8

The 15 µm ID x 15 mm EASY-Spray column was designed to ensure the optimal balance between sensitivity found on a nano-lc separation scale, while providing the throughput benefits of analytical flow LC-MS. Increased loading capacity of this capillary column allows higher sample loading amounts to be analyzed and higher peptide and protein identification rates to be achieved while preserving the robustness and analytical stability necessary for demanding translational studies. In fact, retention time stability of RSD <1% along with peak area stability of RSD <1% can be achieved across hundreds of injections, spanning many days delivering consistent and reliable data that you can trust (Figure 11). In addition, improvements in column consistency and robustness ensure that the 15 µm EASY-Spray column will provide the dependable long-term performance required for demanding applications such as largecohort analysis (Figure 12). The HF-X MS is the perfect complement to the DDA+ workflow with the brighter ion beam, APD, optimized scan matrix with ahcd, and higher MS/MS scan speed, allowing it to achieve a higher level of sensitivity while retaining the throughput benefits of capillary flow and workflow robustness. This enhanced sensitivity essentially allows the 15 µm EASY-Spray column to operate in cap flow mode and achieve quantitative results similar to a traditional nano-lc setup (Figure 13). A Retention time, min System in standby 1 8 EDLIAYLK, RSD% =.46 6 MIFAGIK, RSD% =.72 4 2 KYIPGTK, RSD% =.35 5 1 15 2 25 3 35 Day 1 Injection No. Day 8 B Peak area 4.E+7 EDLIAYLK, RSD% = 5 2.E+8 3.E+7 2.E+8 2.E+7 MIFAGIK, RSD% = 9 1.E+8 2.E+7 8.E+7 8.E+6 4.E+7 KYIPGTK, RSD% = 7.E+.E+ 2 25 3 35 Injection No. Peak area Figure 11. Analytical stability of caplc MS analysis of Cytochrome C protein digest. (A) Excellent retention time stability was observed (RSD <1%) for 35 injections. (B) Peak area stability was evaluated on MS 1 level for 15 consecutive injections conducted between day 5 and 8. Source data Pushing the leading edge in protein quantitation: Integrated, precise, and reproducible proteomic workflows. A RSD=1.8% 4,578 4,55 4,553 RSD=1.9% 29,37 29,552 3,448 B 85% 79% 4,578 4,52 87% 4,29 Quantified, CV <2% Protein Groups Peptide Groups Protein Groups Column 1 Column 2 Column 3 Column 1 Column 2 Column 3 Injection 1 Injection 35 Injection 1 Figure 12. Dependable, robust LC performance for demanding applications. (A) Inter-column consistency with RSD <2% RSD, and (B) long-term quantitative performance are possible with the new 15 µm EASY-Spray column. (Analysis of 4 µg HeLa, 6 min method, UltiMate 3 system, 1.2 µl/min, HF-X MS, 12 K/7.5 K, Top 4). Source data Pushing the leading edge in protein quantitation: Integrated, precise, and reproducible proteomic workflows. Intensity A 3.E+9 HF-X MS 2.5E+9 HF MS 2.E+9 1.5E+9 1.E+9 5.E+8.E+ 1 2 3 Minutes 4 5 6 B Protein Groups 5, 4, 3, 2, 1, Nano-LC 75 µm I.D. 1 µg HeLa Cap-LC 15 µm I.D. 4 µg HeLa 4,548 4,647 4,431 4,418 4,283 3,942 Comparable sensitivity, increased robustness Quantified Complete quan Complete quan and CV <2% 9 Figure 13. HF-X MS combined with caplc-ms demonstrates enhanced MS 1 sensitivity and robustness. (A) 1 µg HeLa digest was analyzed using the 15 μm EASY-Spray column and 6 min LC-MS analysis. The MS 1 base peak chromatograms on each system are overlaid and shown. (B) The improved sensitivity of the HF-X MS allows quantitative results comparable to nano-lc (3 nl/min flow) to be obtained using the 15 μm EASY-Spray column and cap-lc (1.2 µl/min flow). Source data Pushing the leading edge in protein quantitation: Integrated, precise, and reproducible proteomic workflows.

The DDA+ workflow on the HF-X MS is empowered by novel data processing and analysis features in Thermo Scientific Proteome Discoverer software. The optimized, label-free quantitation processing pipeline including, retention-time alignment and feature linking across datasets, can extract more information across replicates, increasing quantitation, and virtually eliminating the missing value issue associated with DDA analysis. This delivers more robust, highly reproducible and precise protein quantification for virtually all the proteins identified (Figure 14 and 15). This precision becomes important when monitoring very subtle biological changes that require very high fidelity quantitation. Taking advantage of the high-resolution, accurate mass (HRAM) capability of the HF-X MS and a high-resolution data independent acquisition (HR-DIA) workflow, excellent peptide quantitation with high reproducibility can also be achieved. The HR-DIA approach is uniquely suited for large scale studies due to its ability to rapidly identify and to reproducibly quantify all ions within an LC-MS analysis. HR-DIA presents a complementary workflow for users undertaking quantitative studies as the high resolving power of the Orbitrap mass analyzer really benefits label-free precursor quantitation. HR-DIA, optimally applied on Orbitrap mass analyzer instruments like the HF-X MS, utilizes high resolution full MS 1 data for quantification and MS 2 information for identification based on spectral libraries. The HF-X MS provides the requisite high-resolving power (12 K or 24 K) on the MS 1 scan to reduce interferences to a minimum, and the brighter ion source and optimized scan matrix offer unparalleled depth of coverage and dynamic range. In addition, the scan speed and sensitivity enhancements on the HF-X MS maximize productivity and quantitative insight (Figure 16A). For users with limited or precious sample, the improved performance attributes of the HF-X MS permit equivalent quantitative results to be generated with only half the amount of sample as before (Figure 16B). The HF-X MS has emerged as the instrument of choice for its HRAM capabilities while retaining the flexibility to provide robust, standardized, reproducible quantification workflows no matter your experimental needs. Rep 1 Rep 2 Rep 3 Completely quantified peptides 5% quantified during MS Missing data = sparse quantitation Complete quantitation Rep 1 Rep 2 Rep 3 97% quantified from DDA+ Figure 14. Maximize quantitative reproducibility and reduce missing data points. A triplicate analysis of 4 µg HeLa protein digest was analyzed using the HF-X MS and DDA+. The heat maps indicate peptides that were commonly quantified across replicates (dark green) and those that were not quantified in one or more replicates (light green). The improved label free quantitation algorithm of DDA+ boosts quantitative information resulting in a more comprehensive analysis. 1 % of Proteins 1 8 6 4 2 Protein quantitation variance 89% 98% 3,329 proteins completely quantified 1 2 3 4 5 %CV 4 2 22,525 peptides completely quantified 1 2 3 4 5 %CV Figure 15. DDA+ enables quantitative confidence through high precision measurements. A triplicate analysis of 4 µg HeLa protein digest was analyzed using the HF-X MS and DDA+. The distribution of the coefficient of variation for all the proteins and peptides that were quantified in the experiment are plotted. % of Peptides 1 8 6 Peptide quantitation variance 81% 97%

A Peptide Precursors (1% FDR) B Protein Precursors (1% FDR) 46,217 42,26 37,367 34,63 25,99 28,231 28,716 21,95 >2% increase 19,772 4,581 4,5 Half sample load 3,39 3,159 2,169 2,413 4,861 3,516 2,818 ID CV% <2% CV% <1% Half the analysis time HF-X 6 mins HF 6 mins HF-X 3 mins HF 4 µg HF-X 2 µg HF-X 4 µg Figure 16. HR-DIA provides unparalleled proteome coverage and reproducibility. A triplicate analysis of HeLa protein digest was analyzed with a HF-X MS and HF MS using an optimized HR-DIA method (12 K MS 1, 3 K DIA, 1 m/z x 8 windows). Data was analyzed using Spectronaut. (A) Peptide groups quantified from 4 µg HeLa protein digest. (B) Protein groups quantified from a 6 minute MS analysis. Why choose Orbitrap mass analyzer technology? Changing research trends and analytical needs have driven mass spectrometry innovation, especially in the past decade. Today s mass spectrometers must be equipped with superior performance features such as high resolution, mass accuracy, dynamic range and fast scanning capabilities in order to fulfill rigorous experimental demands and handle extremely complex samples. In today s research, these same instruments have to provide the flexibility to carry out a variety of analytical techniques including multiplexing and multiple acquisition modes, in addition to being highly robust with consistent performance for high throughput analysis to suit a variety of experimental workflows and varying laboratory needs. Since its introduction in 25, Orbitrap mass analyzer technology has revolutionized mass spectrometry-based research to meet these various challenges across multiple application fields of interest. The exceptional value of Orbitrap mass analyzer systems in delivering uncompromising analytical performance and achieving greater experimental possibilities has been well recognized by the scientific community. Adoption of Orbitrap mass analyzer technology has grown over the years with the proven increase in numbers of Nature and Science family publications (Figure 17). 8 7 Number of Orbitrap Publications 6 5 4 3 2 1 25 26 27 28 29 21 211 212 213 214 215 216 Figure 17. Rising trend in number of Orbitrap mass analyzer-based research publications in Nature and Science journals since its introduction in 25. Source data Nature Family of Journals and Science Journals AAAS. 11

Which Orbitrap mass analyzer system is right for my life science research? The series mass spectrometers have multiple products to suit your research requirements. Table 3. Orbitrap selection guide. Instrument Attributes Focus MS MS Plus MS HF MS Analyzer Orbitrap Orbitrap Orbitrap Ultra-High Field Orbitrap Mass Range m/z 5 3, m/z 5 6, m/z 5 6,; up to 8, m/z with BioPharma option Maximum Resolution at m/z 2 7, 14, 14,; 28, with Enhanced Resolution Mode m/z 5 6,; up to 8, m/z with BioPharma option HF-X MS Ultra-High Field Orbitrap m/z 5 6,; up to 8, m/z with BioPharma option 24, 24, Maximum Scan Speed 12 Hz 12 Hz 12 Hz 18 Hz 4 Hz Top N/MS n Top 3 ddms 2 Top 1 ddms 2 Top 1 ddms 2 Top 2 ddms 2 Top 4 ddms 2 Mass Accuracy Internal Calibration <1 ppm <1 ppm <1 ppm <1 ppm <1 ppm Polarity Switching <1 sec <1 sec <1 sec <1 sec <1 sec Multiplex SIM only (up to 1 precursors) Yes, up to 1 precursors Yes, up to 1 precursors Yes, up to 1 precursors Intact Protein Mode No No Yes Yes N/A BioPharma Option No No Yes Yes Yes Yes, up to 1 precursors Collision Energy NCE and CE Normalized CE Normalized CE Normalized CE Normalized CE Dissociation HCD HCD HCD HCD HCD 12

Which LC should I select for my Orbitrap mass analyzer system? UHPLC portfolio for LC-MS applications. Detailed product specifications can be found on www.thermofisher.com Table 4. UHPLC selection guide. Instrument Attributes Nano-flow LC EASY-nLC 12 Nano-, capillary-, micro-flow LC UltiMate 3 RSLCnano Micro- and analytical flow LC Vanquish Horizon Vanquish Flex Quaternary Analytical flow LC Vanquish Flex Binary Settable Flow-Range 2 2, nl/min 5 µl/min* and 2,5 µl/min**.1 5 ml/min.1 8 ml/min.1 8 ml/min Recommended Flow Range 1 1, nl/min 5 nl/min-5 µl/ min and 5 2,5 µl/min** (isocratic, gradient formation from 5 µl/min) 5 µl/min 5 ml/min 1 µl/min 8 ml/min 1 µl/min 8 ml/min System Pressure 1,2 bar (17,5 psi) 86 bar*** (12,5 psi) 1,5 bar (22, psi) 1, bar (15, psi) 1, bar (15, psi) Pump Binary syringe (high-pressure gradient) 1. Binary serial dual-piston (highpressure gradient); 2. Integrated ternary serial dual-piston (low pressure gradient) Binary parallel dual-piston (highpressure gradient) Quaternary serial dual-piston (low-pressure gradient) Binary serial dual-piston (highpressure gradient) Autosampler Type Pulled loop, zero-loss sample pick up Pulled loop, zero-loss sample pick up Split loop Split loop Split loop System Gradient Delay Volume GDV <1 µl <35 nl in preconcentration configuration Adjustable; default: 175 µl (with 35 µl mixer) Adjustable; default: 62 µl (with 2 μl mixer) Adjustable; default: 175 µl (with 35 µl mixer) Sample Capacity 1 sample rack 3 sample racks 4 sample racks**** 4 sample racks**** 4 sample racks**** Column Temperature N/A Room temperature, +7 C up to 75 C 5 12 C 5 12 C 5 12 C Column Heating Mode N/A Forced air Still air/forced air Still air/forced air Still air/forced air Column Pre-Heating N/A N/A Active and passive Active and passive Active and passive * using dedicated nano-, capillary-, or micro-flow meters ** in integrated micro pump of the NCS-35RS module *** 8 bar (11,6 psi) for capillary- and micro-flow range **** Thermo Scientific Vanquish Charger module is available to increase capacity up to 12 high racks or 23 shallow well-plates 13

Table 5: Which hybrid quadrupole Orbitrap system best suits my experimental requirements? Performance Features Focus MS MS Plus MS HF MS HF-X MS Resolution Sensitivity Speed Dynamic Range Mass Accuracy Multiplexing Table 6: Which hybrid quadrupole Orbitrap system best suits my area of life science research? Application Focus MS MS Plus MS HF MS HF-X MS Peptide IDs TMT Quantitation SILAC Label Free Quantitation Top Down Intact Analysis PTM Phosphorylation Least Fit Best Fit References 1. Scheltema RA, et al. The HF, a Benchtop Mass Spectrometer with a Pre-filter, High-performance Quadrupole and an Ultra-high-field Orbitrap Analyzer. 214 Molecular & Cellular Proteomics, 13, 3698-378. 2. Kelstrup, CD et al. Performance evaluation of the HF-X for shotgun proteomics. Journal of Proteome Research. 218 Jan 5;17(1):727-738. 3. Kelstrup, CD et al. Rapid and Deep Proteomes by Faster Sequencing on a Benchtop Quadrupole Ultra-High-Field Orbitrap Mass Spectrometer. Journal of Proteome Research. 214 Dec 5;13(12):6187-95. Find out more at thermofisher.com/qexactivehfx 218 Thermo Fisher Scientific Inc. All rights reserved. Spectronaut is a trademark of Biognosys Inc. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. WP65128-EN 218M