GypLyner UNIVERSAL Metal framed wall lining system

Similar documents
GypLyner UNIVERSAL Metal framed wall lining system

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Issue date: 1st May Key changes since original publication (July 2005):

Staggered stud acoustic partition system

Tiling Tiling

C05. S03. P02 P08 FireWall

Staggered stud acoustic partition system

The extra strong, extra durable, sound resistant system that you can direct fix to

ShaftWall. Shaft and duct encasement system. ShaftWall.

Quantity take-off details

Tiling Tiling Finishes C08

Loadbearing timber joist floors

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

C06. S02. P02 P22 CasoLine mf

CO9. Sound absorbing solutions C09

Boards. Products - Boards.

C05. S02. P02 P30 ShaftWall

GypLyner universal. Internal wall insulation (IWI) installation guide

Selecting partitions

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE.

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Thermal Laminate Board.

DriLyner rf. Internal wall insulation (IWI) installation guide

June Non - Residential Refurbishment Internal lining walls

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD

June Residential Refurbishment Separating walls

December 2011 OFF-SITE. Off-site solutions

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD

Knauf MF Suspended Ceilings

F L O O R S A N D C E I L I N G S

Plastering. Holiday Inn - Sultanate of Oman

USGBORAL.COM SYSTEMS+ INTRODUCTION OUTRWALL BRICK VENEER WALLS EXTERNAL WALLS INNOVATIVE SYSTEMS SOLUTIONS

Multi-layer Insulation Blanket for Walls

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

PITCHED ROOF SOLUTIONS

Multi-layer Insulation Blanket for Walls

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

SOUND INSULATION TESTING IN DWELLINGS


Thermal Laminate Board.

Product Information Sheet

TILING SPECIFICATIONS

CI/SfB. November Design Guide Concrete block masonry

Garage Conversion - Between and Under Joist Applications

June Residential New Build Render and cladding walls

Plaster systems. Plaster systems.

URSA MINERAL WOOL URSA Cavity Batts

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

Multi-layer Insulation Blanket for use in Walls

Multi-layer Insulation Blanket for Walls

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

ASSEMBLY INSTRUCTION TG 2002

Benefits.

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

SECTION GYPSUM BOARD

Building Design Data

icore HR outperforms other building boards in many important ways including the following:

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internal Wall PRODUCTS: Vencel Resil Limited

RMF Intercell. NBS Specification 2013 K41

CI/SfB (2-) Rn7 (M2) Cavity Wall Specification Guide

The Celotex Handy Guide

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

The ecological choice. Besblock STAR PERFORMER. The multi-purpose energy saving block JULY 2014 UNIVERSAL, COST EFFECTIVE, DELIVERABLE

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

Specialists in Acoustic Flooring and House to Flat Conversions

The GlasRoc Shaftliner Type X advantage...

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

SoundBlocTM. Gyproc SoundBloc Plasterboard. Technical & Safety Datasheet.

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

URSA MINERAL WOOL URSA Acoustic Roll

June Residential Refurbishment Exposed soffit floors

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

Fire Door Installation

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

Knauf Safeboard. X-ray partitions. Lead-free X-ray shielding plasterboard. 100% lead-free board. Economical radiation protection.

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

GIB Quiet Clip GIB CBI March Features and Benefits

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Brick Veneer Walls. Insulation

Rondo steel stud. Framing Systems Installation Manual. revised: october 2008

SECTION GYPSUM BOARD ASSEMBLIES

Transcription:

Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury offices, Bournville, Birmingham 66

wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system that is suitable for all internal non-loadbearing applications. C B A 9 66 R w db 0. 0. W/m K Key facts Commonality of ceiling and wall lining components General purpose lining Minimal connection to the structure Overcomes difficulties of background irregularities Can satisfy thermal performance and acoustic requirements GypWall RAPID GypLyner and RAPID UNIVERSAL db Plus Provides service void of mm - mm A Gypframe GL Lining Channel + B C Gypframe GL or GL9 Bracket + C Gypframe GL8 Track Ideal for refurbishing existing walls where: - wall surface quality is poor - acoustic or thermal upgrades are required - a cavity is required to accommodate services, such as water and waste pipes Applications Due to the design flexibility of, this system can be tailored to meet the requirements of a wide range of applications. Sector Office / commercial Education Housing Retail Healthcare Apartment buildings Sport and leisure Industrial High-rise multi-occupancy 6

L SPECSURE S Y S T E M www.british-gypsum.com System components Gypframe metal products GL Lining Channel GL Bracket For maximum mm stand-off from wall. 00, 00mm 000, 600mm 9mm Board products (continued) Gyproc DuraLine Thickness Width Gyproc ThermaLine boards Thickness Width mm 00mm - 90mm 00mm Moisture resistant boards are specified in intermittent wet use areas, GL9 Bracket For maximum mm stand-off from wall. 9mm e.g. shower cubicles. NB DUPLEX grade board is used as an external wall lining to control water vapour transmission. GL Channel Connector GL8 Track 600mm Fixing and finishing products Gypframe GL GypLyner Anchors For fixing Gypframe GL, GL9 or GL Brackets to concrete / masonry. Gyproc Wafer Head Drywall Screws For metal-to-metal fixing up to 0.9mm thick. 99 FC 0 Fixing Channel 00mm 0 FC 90 Fixing Channel 9mm Gyproc Drywall Screws For fixing boards to Gypframe metal framing and brackets to timber supports. Gyproc Sealant Sealing air paths for optimum sound insulation. Service Support Plate For the installation of plywood within a partition cavity. GFS Fixing Strap GFT Fixing T 0mm 00mm 00mm Gyproc jointing materials For seamless jointing. Gyproc edge and angle beads Protecting and enhancing board edges and corners. Gyproc Control Joint To accommodate structural movement. Thistle Board Finish or Thistle Multi-Finish To provide a plaster skim finish. Board products or Gyproc WallBoard Thickness Width., mm 900, 00mm Thistle Durafinish To provide improved resistance to accidental damage. Gyproc WallBoard DUPLEX Thickness Width Gyproc SoundBloc Thickness Width., mm 900, 00mm., mm 00mm Insulation products Isover APR 00 mm or 0mm, for improved acoustic performance. Isover CWS 0mm, for improved thermal and acoustic performance. I F E T I M E W A R R A N T Y Always use genuine branded British Gypsum components to qualify for SpecSure lifetime warranty 68

T 08 800 99 F 08 6 886 E bgtechnical.enquiries@bpb.com Installation overview The required cavity depth up to a maximum of mm is determined, and chalk lines marked to floor and ceiling to indicate positioning of the Gypframe GL8 Track. Gypframe GL8 Track is fixed to perimeters using appropriate fixings. Vertical lines are marked on the wall at appropriate intervals to indicate Gypframe GL or GL9 Bracket fixing centres. Horizontal lines are marked at appropriate centres to determine individual bracket positions. Brackets are then fixed into position. Gypframe GL Lining Channels are friction-fitted into the track, extending if required. Bracket legs are bent forward and each leg fixed to the Gypframe GL Lining Channel. The protruding bracket legs are bent back to sit clear of the channel face. Openings Gypframe GL Lining Channel is positioned either side of the door opening and fixed to the Gypframe GL8 Track at head and base. A section of Gypframe GL8 Track is cut and bent to form the head of the opening. Short lengths of Gypframe GL Lining Channel are positioned above the opening to provide additional support and to maintain appropriate support centres. At window openings, Gyproc edge bead is fixed to the perimeter of the window frame to protect and retain the lining. See Construction details. For full installation details, refer to the British Gypsum SITE BOOK, available to download from www.british-gypsum.com At internal angles, a Gypframe GL Lining Channel is positioned tight into the corner to provide support for the lining. Boards are fixed to all framing members. For full installation details, refer to the British Gypsum SITE BOOK, available to download from www.british-gypsum.com 69

www.british-gypsum.com Performance ( Refer to section - Basic principles of system design) Table new-build - meeting thermal insulation requirements for external cavity walls L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Brick / cavity / block wall comprising 0mm brick skin, 0mm clear cavity, block inner leaf. Brick / cavity / block wall comprising 0mm brick skin, 0mm Isover CWS, block inner leaf. Detail Board Lining Minimum Minimum U-value type thickness overall wall Aircrete block (λ = 0. W/mK) inner leaf ThermaLine SUPER 0 8 0. ThermaLine SUPER 60 8 0.6 ThermaLine SUPER 90 68 0.9 ThermaLine PLUS 0 0. ThermaLine SUPER 0 08 0.8 ThermaLine PLUS 0 8 0. Medium density block (λ = 0. W/mK) inner leaf ThermaLine SUPER 60 8 0. ThermaLine SUPER 0 8 0. ThermaLine SUPER 90 68 0. ThermaLine PLUS 0. NB Calculations are based on the proportional area and combined methods for determining U-values of structures containing repeated thermal bridges in accordance with BS EN ISO 696. NBS work section K0 - Plasterboard drylinings / partitions / ceilings 0

T 08 800 99 F 08 6 886 E bgtechnical.enquiries@bpb.com Table refurbishment - upgrading thermal insulation of external walls L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Brick / cavity / brick wall comprising 0mm cavity brick skin. 0mm clear cavity, 0mm inner brick plastered. Solid brick wall (mm) with inner face plastered. Detail Board Lining Minimum Minimum U-value type thickness overall wall Outer brick (λ = 0. W/mK), inner brick (λ = 0.6 W/mK), solid brick (λ = 0. W/mK) ThermaLine PLUS 0 0. ThermaLine SUPER 60 0. ThermaLine SUPER 0 6 0. ThermaLine SUPER 0 0 0. ThermaLine SUPER 0 0.9 Subject to severity of exposure and weathertightness. Including mm Isover APR 00 in the cavity / framing. NB Calculations are based on the proportional area and combined methods for determining U-values of structures containing repeated thermal bridges in accordance with BS EN ISO 696. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

www.british-gypsum.com Performance ( Refer to section - Basic principles of system design) Table refurbishment - upgrading sound insulation of solid internal walls L I F E T I M E SPECSURE S Y S T E M W A R R A N T Y Solid brick wall (0mm) with mm plaster each side and Gypframe GL Lining Channel framework fixed to one side to give mm cavity. Lining as in table. Solid brick wall (0mm) with mm plaster each side and Gypframe GL Lining Channel framework fixed to one side to give mm cavity. Cavity filled with mm Isover APR 00. Lining as in table. Solid brick wall (0mm) with mm plaster each side and Gypframe GL Lining Channel framework fixed to both sides to give mm cavities. Cavities filled with mm Isover APR 00. Solid block wall, of mass 00kg/m, with mm plaster each side. Gypframe GL Lining Channel framework fixed to one side to give mm cavity. Cavity filled with mm Isover APR 00. Solid block wall, of mass 00kg/m, with mm plaster each side. Gypframe GL Lining Channel framework fixed to one side to give 8mm cavity. Cavity filled with 0mm Isover APR 00. Detail Board Lining Sound insulation System type thickness Improvement over reference existing wall R w (R w + Ctr) R w (R w + Ctr) mm db db SoundBloc x. 9 () + (-) B6009 SoundBloc x. (0) +0 (+6) B6008 SoundBloc x. 60 () + (-) B600 SoundBloc x. (0) +0 (+6) B6008 SoundBloc x. 60 () + (+) B600 SoundBloc x. 6 (6) + (+) B600 SoundBloc x. 66 (9) +9 (+) B600 NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings

T 08 800 99 F 08 6 886 E bgtechnical.enquiries@bpb.com Design Planning - key factors The depth of the cavity is determined by the positioning of the fixing brackets. Allow for a stand-off of mm - mm plus the lining thickness for Gypframe GL Brackets, and mm - mm plus the lining thickness for Gypframe GL9 Brackets. These stand-offs are sufficient to correct irregularities normally encountered in solid backgrounds. The stand-off will determine the lining dimension required at door and window reveals and soffits. Ceilings should be installed prior to installing wall linings. Any abutting partitions should also be installed prior to drylining. Cavity barriers Building Regulations may require the provision of vertical cavity barriers to long runs of lining. Minimum.mm plasterboard, cut to cavity depth and screw-fixed to the leg of Gypframe GL Lining Channel, will provide a satisfactory cavity barrier. Refer to section 0 Cavity fire barriers. Cabling Thermal performance Uncontrolled air movement through the drylining cavity can result in excessive heat loss from the building. The quoted U-values for wall lining are based on a sealed cavity between the lining and the background. This is achieved in practice if the abutting elements and the background are well fitted, and junctions are sealed. When the perimeter of the cavity is to be sealed by the drylining contractor, the recommended method is to apply a continuous fillet / ribbon of Gyproc Dri-Wall Adhesive or Gyproc Sealant to the perimeter of the external wall and around any openings. Central heating and waste pipes The designer should also specify a method of restricting air movement around the perimeter of suspended timber floors, such as the provision of a flexible seal between the floor and walls. Good standards of thermal insulation can be achieved where Gyproc ThermaLine laminates are specified as the lining. There may, however, be a slight risk of pattern staining where temperature, humidity, and soiling conditions are extreme. Wall lining rigidity Brackets should be positioned equidistant at maximum 800mm vertical centres. Where there is a requirement for increased rigidity, these support centres should be reduced accordingly, although acoustic performance may be downgraded. Gypframe GL GypLyner Anchors are recommended for fixing brackets to the solid background. Services The cavity between the metal framework and the background facilitates the incorporation of services. Pipes and conduits should be fixed in position before installing the framing. When installing Gyproc ThermaLine laminates, the insulation should not be chased to accommodate services. PVC covered cables must not come into contact with polystyrene insulation. Suitable isolation methods such as conduit or capping should be used. Refer to section. Service installations. Soil pipes Fixtures Lightweight fixtures can be made directly to the lining. Medium weight fixtures should be made to Gypframe 99 FC 0 Fixing Channel. Heavyweight fixtures (to BS ), such as wash basins and wall cupboards, can be fixed using Gypframe 0 FC 90 Fixing Channel. Refer to section.. Service penetrations and fixing into drywall systems. Board finishing Refer to section Finishing systems and decorative effects. For more information refer to the British Gypsum SITE BOOK, available to download from www.british-gypsum.com Please refer to section - Basic principles of system design for general guidance

www.british-gypsum.com Construction details Head and base External angle Internal angle 8 6 Partition junction Window reveal 0 9 6 Gyproc plasterboard Gypframe GL Lining Channel Gypframe GL or GL9 Bracket fixed with Gypframe GL GypLyner Anchor Gypframe GL8 Track Gyproc Sealant Bulk fill with Gyproc jointing materials (where gap exceeds mm) 8 9 0 Wall structure Skirting Gypframe C Stud Gyproc Drywall Edge Bead Window frame

T 08 800 99 F 08 6 886 E bgtechnical.enquiries@bpb.com