Experimental Assessment of Hygrothermal Performance of Wood Frame Wall System in Suzhou's Lake Tai Climate Zone

Similar documents
MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

Thermal Bridging in Residential Construction

Flexible Vapor Control Solves Moisture Problems of Building Assemblies - Smart Retarder to Replace the Conventional PE-Film

Smart Vapor Retarders

Building America Special Research Project: High-R Walls Case Study Analysis

MOISTURE ACCUMULATION IN WALLS: COMPARISON OF FIELD AND COMPUTER-PREDICTED DATA

Buildings XI Conference Workshop 2: Thermal Mass IV Assessing Thermal and Moisture Control Benefits of PCM Components by Hygrothermal Simulation

Insulating Basements: Part 1 Fundamentals

ENERGY PERFORMANCE R-VALUE: PART 2, EXAMPLES OF INTEGRATED METHODOLOGY FOR EVALUATION OF ENERGY EQUIVALENT R-VALUE FOR BUILDING ENCLOSURES;

Balancing the Control of Heat, Air, Moisture, and Competing Interests

Spray Polyurethane Foam: The Need for Vapor Retarders in Above-Grade Residential Walls

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

This presentation. Basements: New & Retrofit. Basements Part of the Enclosure. Basements are Changing. Basement functions Basement Performance

The Role of Control Layers in Building Enclosure Design

The Role of Control Layers in Building Enclosure Design

Moisture Considerations for Insulated Building Assemblies

This presentation. Functions of the building enclosure. University of Waterloo and Balanced Solutions. Straube Presentation Building Canada

2013 COMMERCIAL PRODUCTS

Insulations, Sheathings and Vapor Retarders

Vancouver Field Exposure Facility: Phase IV Construction and Instrumentation Report

Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components

Moisture and temperature conditions in cold lofts and risk of mould growth

Vapor Barriers and Air Barriers

When R-Value Doesn t Measure Up

building science.com Building Science Digest 106 Understanding Vapor Barriers (rev. April 2011) by Joseph Lstiburek Abstract:

Vapour Diffusion for Residential Construction. Canada and Northern USA VAPOUR DIFFUSION FOR RESIDENTIAL CONSTRUCTION CANADA AND NORTHERN USA

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

InSoFast Outperforms R-13 Fiberglass

Published in: Proceedings Thermal Performance of the Exterior Envelopes of Whole Buildings XI, Dec 5-9, 2010, Clearwater Beach, Florida

Hygrothermal Performance Study. (Experimental & Modeling)

The REMOTE Wall System

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

Building Science for Architects. Introduction. Betsy Pettit, AIA Building Science Corporation

PH-CALCULATION Dynamic simulation with WUFI

Parex Continuous Insulation (CI)

Building Enclosure Details and Assemblies for Wood-Frame Buildings

Continuous Insulation Systems for Exterior Walls

Sealing the Envelope with SPF Insulation

THERMAL INSULATION FROM WOOD FOR BUILDINGS:

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

Airspace R-Values. Educational Overview. Revised 12/6/2016

BUILDING ENCLOSURE DESIGN GUIDE WOOD FRAME MULTI-UNIT RESIDENTIAL BUILDINGS. Summary. 1. Introduction

Building Envelope Systems Exam Learning Objectives

Integrated Air & Water Barrier Systems

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

Thermal Performance. of Light-Frame Assemblies. Building series NO. 5

ASHRAE Standard 160P Criteria for Moisture Control Design Analysis in Buildings

Adapted vapour control for durable building enclosures

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

2006 Building Science Press All rights of reproduction in any form reserved.

STUCCO FAILURES and REMEDIATION Roger G. Morse AIA

Integrated Wall Retrofit Solutions for Existing Masonry Construction for Commercial Buildings

Throughout the balance of this paper the terms attic and roof will and can be used interchangeably.

Performance-Risk Methodology for the Design of High-Performance Affordable Homes

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

How to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements. Ted Winslow

FULLBACK V PREMIUM SIDING INSULATION FOR VINYL

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

A Building Science Toolbox...

Integrated Solutions for Every Insulation Need. Complete Comfort

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

Apartment building Sodastraße 40 in Ludwigshafen, DE

Building Enclosure Performance for Existing and New Buildings

BC Building Code Overview

CONDENSATION IPROPLEMS IN.Al21n1 BUILDINGS

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Vancouver Field Exposure Facility: Phase III Exterior Insulation Analysis

Initial Study of the Moisture Performance of OSB-Sheathed Walls in Homes in Climate Zones 4 and 5

Introducing TJ Insulated Structural Framing Components

Image courtesy of KTGY, Inc. ENGINEERED FOR FIRE CODE COMPLIANCE AND DESIGN FLEXIBILITY

Insulation Retrofit Options

CertainTeed TECHNICAL BROCHURE

COLD CLIMATE HOUSING RESEARCH CENTER CCHRC. Whole Wall R-Values

Zack LeRoy Panel Pros Inc., Keene, NH (800)

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Background Basement Thermal Behavior

Net Zero Building Enclosure Retrofits for Houses: An Analysis of Retrofit Strategies

Chapter Meeting: Joint Meeting with Boston CSI and ICRI at Granite Links Insulating Load-Bearing Masonry Building January 8, 2014

Mid-Rise Wood Construction Solutions Guide

AIR BARRIERS & WATER-RESISTIVE BARRIERS

Gold Bond BRAND Gypsum Sheathing

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

High Performance Roofs How to Beat the Heat

Inside Why Spray polyurethane Foam insulation? All About Spray polyurethane Foam Book 1

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Air Infiltration & Insulation

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Carpenter Level 2 Rev. September 2017

Armourwall Stucco Systems

Developing Durable CLT Building Enclosure Assemblies

Floor Truss Ribbon Board Load Path

Technical Guide DELTA -VENT SA

How Many Times Can You Repaint the Exterior of Your Building? Kevin Brown KTA-Tator, Inc.

Transcription:

Experimental Assessment of Hygrothermal Performance of Wood Frame Wall System in Suzhou's Lake Tai Climate Zone Xiaohuan Wang, a Benhua Fei, b, * and Jun Ni c A long-term onsite assessment of the hygrothermal performance of a wood frame wall system is presented in this work. The system was applied in a wood demonstration house within the Lake Tai climate zone of Suzhou, China. The hygrothermal performance of the cavity insulation wall was determined from the temperature, relative humidity, and from the temperature of the wood material surface throughout the year. The results clearly indicated the effect of the cavity insulation, cladding cavity ventilation, and air-vapor barrier. Thermal performance was very good due to the wall cavity insulation. Cladding cavity ventilation was effective at low relative humidity of the insulated wall cavities. Condensation and mold growth were not found inside the wall during the test period. The wood frame wall system had good hygrothermal performance and may be widely used in hot summer and cold winter climate zones in China. Keywords: Hygrothermal performance; Wood frame wall; Insulation; Vapor retarder; Climate Contact information: a: Beijing Forestry Machinery Research Institute of the State Forestry Administration, Beijing 100091, China; b: International Centre for Bamboo and Rattan, Beijing, 100102, China; c: Suzhou Crownhomes Co., Ltd., Jiangsu, 215105, China; * Corresponding author: feibenhua@icbr.ac.cn INTRODUCTION The city of Suzhou in southeast China has a hot summer and cold winter climate with varying temperature and relative humidity levels. The complicated environment of hot, wet, humid, and cold conditions poses difficulties in the design of building walls when it comes to energy saving and durability. Wood frame buildings have been constructed in this zone; however, research on the hygrothermal performance of wood frame wall systems in these climatic conditions has not been performed. Thus, there are no useful data for building design and assessment. Long-term onsite assessment of hygrothermal performance has been used as a reliable method for developing energy-efficient and durable wood frame wall systems. Heat and moisture transfer through a wall have been measured for different materials and climatic conditions (Gatland and Karagiozis 2007; Toman et al. 2009; Maref et al. 2008; Tichy and Murray 2007). For instance, by comparing three interior vapor control strategies, the experimental results indicated that a 50 μm polyamide film used as an interior vapor retarder in wall systems, common to the Pacific Northwest of the US, would enhance the ability of a wall system to maintain lower relative humidity. Also the on-site experimental hygrothermal performance analysis of an interior thermal insulation system was presented, which was applied during the summer period on a brick-built Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4702

house from the end of 19 th century. The thermal resistance increased approximately two times, and water condensation was never observed inside the envelope. Dynamic changes in temperature, relative humidity, and moisture content can reveal the function of each material in multilayer walls. Factors such as ventilation, airtightness, insulation, infiltration, and vapor diffusion affect the wall s hygrothermal performance. Experiments and simulation results have been helpful for improving the hygrothermal performance of the exterior wall system (Glass and TenWolde 2007; Karagiozis and Desjarlais 2007; Tariku et al. 2009), and professional guidance and recommendations have been provided. Results from these research studies contributed to the building code requirement for a wood house with good performance in different climates. This study was carried out to develop and implement long-term onsite monitoring of hygrothermal responses of a wall system. We tested one multifamily wood frame wall assembly of a wood demonstration house in a park beside Suzhou's Lake Tai. Both sides of the wall, insulated wall cavity, and ventilation cavity conditions were monitored for the air temperature and relative humidity, and the surface temperature of the wood material in the wall was tested. EXPERIMENTAL Tested Building and Wall Configuration A wood demonstration house was built in a park beside Lake Tai by Suzhou Crownhomes Co., Ltd. (Fig. 1). The house has a post and beam structure with a 125-mmthick wall fixed within the main structure. Fig. 1. Demonstration test house The configuration of the multilayer wall is illustrated in Fig. 2. The exterior walls were framed with 38-mm by 70-mm studs and sheathed with 9.5-mm oriented strand board (OSB). Thermal insulation was achieved by inserting premium loose-fill fiberglass insulation into the cavity between studs. A continuous polyethylene film on the interior surfaces of the cavity insulation was used as an interior vapor retarder. The exterior wall finish was stucco. Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4703

Fig. 2. Configuration of multilayer wall Instrumentation and Sensor Locations One profile in the south exterior wall on the first floor was chosen for analysis. Air temperature and relative humidity were monitored with a JWSK-6ACC05 sensor (0.1 and 0.1 % resolution). Surface temperature was measured using type-t thermocouples calibrated to 0.1 K. All sensor locations are shown in Fig. 3. Air temperature and relative humidity sensors (RHT1 RHT10) were placed in each layer from the inside to the outside of the wall. These sensors were installed 300 mm from the top and bottom of the test wall. Surface temperature (T1 tot6) sensors of studs and OSB were positioned in the cavity insulation. T1 and T5 were located at the centers of the top and bottom wood plates, and T2 and T4 were in the exterior sheathing board and were 300 mm from the top and bottom wood plates. T3 and T6 were situated in studs and the exterior sheathing board, respectively, and were centered vertically between the top and bottom plates. Sensors were connected to the data collection equipment. Data were recorded in a computer every minute and could be flexibly extracted every 30 min or every hour for analysis by the operating software. The monitoring process began in June 2010, and testing has been continuous for over two years. Fig. 3. Sensor locations in the tested wall Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4704

Relative humidity /% Temperature / PEER-REVIEWED ARTICLE RESULTS AND DISCUSSION Changes of Interface Temperatures and Relative Humidity The trend was basically similar between RHT1 RHT5 and RHT6 RHT10, as described in a previous research report (Wang 2011). Thus, Figs. 4 and 5 only show air temperature and relative humidity changes for RHT1 RHT5 throughout the year (except for August, in which there were missing data). The air temperature variance of each interface of the wall from April to October was less than that from November to March of the next year. The air temperature of the medial wall was similar to that at the interface between the gypsum board and vapor retarder. The change of air temperature at the interface between the insulation layer and OSB sheathing board was closer to that of the lateral wall, which confirmed the effective function of the insulation layer. On the coldest day in January, despite the lateral wall air temperature being near 3.0 C, the temperature of the medial wall remained over 11 C. On the hottest day in July, despite the lateral wall air temperature reaching 37.0 C, the temperature of the medial wall was only 25 C. It is thus clear that the temperature difference between the medial wall and lateral wall maintained the ideal level from spring to autumn. 40 35 30 25 20 15 10 5 0-5 6/24/11 7/9/11 9/16/11 10/18/11 11/12/11 12/12/11 1/12/12 2/12/12 3/12/12 4/12/12 5/12/12 Date(Month/Day/Year) the medial wall gypsum/vapor retarder insulation/osb air space ventilation cavity the lateral wall Fig. 4. Changes in interface temperatures throughout the year 100 90 80 70 60 50 40 30 6/24/11 7/9/11 9/16/11 10/18/11 11/12/11 12/12/11 1/12/12 2/12/12 3/12/12 4/12/12 5/12/12 Date(Month/Day/Year) the medial wall gypsum/vapor retarder insulation/osb air space ventilation cavity the lateral wall Fig. 5. Changes in interface relative humidity throughout the year Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4705

Temperature / PEER-REVIEWED ARTICLE Relative humidity changes were directly related to temperature because increasing temperature could lead to increasing steam partial pressure. The relative humidity variance of the lateral wall ranged from 30% to 99%, and that of the medial wall was smaller and steadier. The relative humidity of the medial wall, that of the interface between the gypsum board and vapor retarder, that of the interface between the insulation and OSB sheathing board, and that of the air space ventilation cavity showed similar trends. The differences among each interface from December through the following March were larger than for other months because of the low indoor temperature in the winter. In addition, the peak temperature and relative humidity on each interface clearly showed a hysteresis behavior from the medial to the lateral wall. There is thus an absorption and release process to heat and water vapor for the materials of the wall. However, the delay time for the wood wall was shorter than that for concrete or masonry construction walls because wood wall is of lightweight construction. Effect on Hygrothermal Performance for Materials and Construction of Wall Insulation layer The temperature was measured monthly on the coldest day outdoors from October through the following March and was used to analyze heat transfer through the multilayer wall. Temperature gradients through the tested wall profile are shown in Fig. 6. It is clear that temperature obviously decreased from the medial to the lateral wall, and the temperature difference was greatest between the gypsum board and OSB sheathing board in the heat transfer process from the medial to the lateral wall. The greatest temperature difference value was 8 C in December. The effect of insulation is very significant and kept the interior of the house relatively warm. 25 20 15 10 5-5 0 15 85 94.5 124.5 Distance/mm Fig. 6. Temperature gradients through the test wall profile 0 10/25/11 11/21/11 12/17/11 1/23/12 2/3/12 3/12/12 Vapor retarder of polyethylene film Relative humidity was measured monthly on the coldest day outdoors from October through the following March and was used to analyze moisture transfer through the multilayer wall. Relative humidity gradients through the tested wall profile are shown in Fig. 7. It is clear that relative humidity increased from the medial to the lateral wall, and the difference was great between the gypsum board and OSB sheathing board. The greatest relative humidity difference value was 15% in January. Therefore, the polyethylene film is a good barrier material to stop air and vapor movement. Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4706

Relative humidity /% PEER-REVIEWED ARTICLE From the differences in the relative humidity seen in Fig. 5, it is clear that the polyethylene film in the wall assembly was able to stop the movement of moisture into or out of the conditioned space. Thus, the relative humidity in the insulation cavity was always lowest when the outside air was humid or the indoor air was hot-humid in the summer. However, the lower relative humidity indoors might lead to drying and cracking of the wood elements because of dry air conditions indoors during the winter. Otherwise, the relative humidity of the OSB cavity-side was not more than 70% throughout the year, so not only are there no risks of mold growth and condensation, but the relative humidity indoors can be improved in the winter without the polyethylene film layer. 90 80 70 60 50 40 30 20 10 0 0 15 85 94.5 124.5 Distance/mm 10/25/11 11/21/11 12/17/11 1/23/12 2/3/12 3/12/12 Fig. 7. Relative humidity gradients through the test wall profile Waterproof and moisture-permeable building paper The relative humidity at the interface between the insulation layer and OSB sheathing board was comparatively stable (Fig. 5) and was lower than that inside the ventilation cavity, with differences between 7% and 10% (Fig. 7). These results imply that it is more effective to use waterproof and moisture-permeable building paper under conditions of high outdoor relative humidity. Moisture penetration was impeded from the wall ventilation cavity into the interior of the house. Stucco and air space ventilation cavity Relative humidity gradients were largest in the interface between the ventilated cavity and the lateral wall (Fig. 7). The maximum gradient was 34% in December. Both the stucco and air space ventilation cavity were clearly effective in preventing moisture and rain. Data showed that relative humidity inside the cladding cavity was always lower than that of the lateral wall before it reached maximum, and the relative humidity peak inside that cavity confirmed hysteresis behavior (Fig. 5). The temperature difference between the ventilated cavity and the lateral wall was about 4 C. This confirmed that heat loss was reduced due to the thermal resistance of the air space. Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4707

Temperature / PEER-REVIEWED ARTICLE Wood frame and board The surface temperatures of SPF frame dimension lumber and OSB sheathing board are shown in Fig. 8. Surface temperatures of the OSB sheathing board at T2, T4, and T6 developed continuously with changes in lateral wall temperatures and were influenced by the outdoor temperature conditions. The wood frame surface temperatures at T1, T3, and T5 became smaller than those of the OSB sheathing. There was a certain heat barrier due to both the wood frame and insulation material. Figure 9 shows that the surface temperature was lower because of the stud thermal bridge, especially the temperature of the corner of the wood frame in the roof, which was the lowest at only 10 C. Therefore, a detailed structure and construction technique is most important to prevent energy consumption due to air leakage. 45 40 35 30 25 20 15 10 5 0-5 10/18/11 11/12/11 12/12/11 1/12/12 2/12/12 3/12/12 4/12/12 5/12/12 Date(Month/Day/Year) T1 T2 T3 T4 T5 T6 the lateral wall Fig. 8. Surface temperature of wood materials of SPF and OSB Fig. 9. Infrared spectra of the inner surface of the wall Durability Durability is closely related to hygrothermal performance. In particular, humidity can lead to destruction of wood components of a house. Wood durability is likely affected by mold growth on the surface in cases where the relative humidity remains above 80% for a long time. During the test period, the temperature of the ventilated cavity reached 37 C with the highest relative humidity of 84% in July, but the duration of high temperatures and relative humidity was not continued at length. Consequently, there was no mold growth (Li 2009). Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4708

When the relative humidity of both the medial and lateral walls was high in summer, the relative humidity of the OSB cavity-side was the lowest. All temperatures were above 0 C in winter, and the relative humidity was less than 80% under the rainy and humid weather. Therefore, water condensation in the wall was not found. CONCLUSIONS 1. The wood frame wall system demonstrated good hygrothermal performance, and the temperature and relative humidity were stable in the climate conditions of Suzhou's Lake Tai, with a hot summer and cold winter. 2. The good thermal performance of the wall is attributed to the cavity wall insulation within it, according to temperature gradients through the tested wall profile. 3. The water control strategy of using polyethylene film and building paper provides a high level of moisture resistance to reduce air relative humidity in the test wall and interior. 4. Cladding and a ventilation cavity can greatly enhance moisture tolerance and reduce moisture-related risks for a multilayer wall. There was no mold growth or water condensation inside the wall during the test period. 5. The test wall system can be widely used for environmentally-friendly buildings in the hot summer and cold winter climate zone of China. ACKNOWLEDGMENTS The authors gratefully acknowledge funding from the Twelfth Five-Year Plan of the national science and technology support project Grant. No. 2012BAD23B0105 and the leading talent project in Suzhou Wuzhong District Grant. No. WC201107 for this research. REFERENCES CITED Gatland, S., and Karagiozis, A. (2007). The hygrothermal performance of wood-framed wall systems using a relative humidity-dependent vapor retarder in the Pacific Northwest, ASHRAE Transaction. Glass, S. V., and TenWolde, A. (2007). Review of in-service moisture and temperature conditions in wood-frame buildings, General Technical Report FPL-GTR-174. USDA, Forest Products Laboratory, Madison, WI. Karagiozis, A., and Desjarlais, A. (2007). Developing innovative wall systems that improve hygrothermal performance of residential buildings, Oak Ridge National Laboratory. http://www.energy.wsu.edu/documents/building/ornl_hygrothermal_final.pdf. Li, J. (2009). Wood Science Research, Science Press, Beijing. Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4709

Maref, W., Tariku, F., and Di Lenardo, B. (2008). NRC-IRC develops evaluation protocol for innovative vapour barrier, Construction Innovation 13, 6. Toman, J., Vimmrová, A., and Černý, R. (2009). Long-term on-site assessment of hygrothermal performance of interior thermal insulation system without water vapour barrier, Energy and Buildings 41(1), 51-55. Tichy, R., and Murray, C. (2007). Developing innovative wall systems that improve hygrothermal performance of residential buildings progress report, Washington State University, wood material and engineering laboratory. http://www.energy.wsu.edu/documents/wsu_hygrothermal_fianl.pdf Tariku, F., Maref, W., Di Lenardo, B., and Gatland, S. (2009). Hygrothermal performance of RH-dependent vapour retarder in Canadian coastal climate, 12th Canadian Conference of Building Science and Technology, Montreal, QC. Wang, X. H. (2011). Research on thermal performance of wood frame wall, Postdoctoral report, Chinese Academy of Forestry, Beijing. Article submitted: June 7, 2013; Peer review completed: July 15, 2013; Revised version accepted: July 24, 2013; Published: July 29, 2013. Wang et al. (2013). Wood frame wall system, BioResources 8(3), 4702-4710. 4710