Screeds. RonaScreed Underfloor Heating Screed. Rapid drying additive for floating screeds. Description. Drying Time of 50mm screed

Similar documents
Flooring and Bedding. RonaFloor SL. Self-smoothing seamless epoxy resin flooring system

Resin Bound and Bonded Surfacing. RonaDeck UV Rubber Granule Tree Pit Base. Resin bound rubber granule porous tree pit system.

EcoGran UV Resin Bound Surfacing System

a new liquid screed solution from

Screedmaster Ultimate

Eco Resin Bound UV Surfacing System

CHARACTERISTICS / ADVANTAGES

PPC Cement TUTORIAL. how to screed a floor

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

DURABASE CI. Underlay mats for decoupling and sealing tiled flooring 1/5 A P P L I C A T I ONS AND FUNCTION.

TECHNICAL DATA SHEET SIKALEVEL 25 LATEX SELF LEVELLING 25KG

MasterEmaco S Lightweight, polymer modified, fibre reinforced, structural repair mortar. Formerly: Emaco Nanocrete R3 DESCRIPTION

The ultimate free-flowing floor screed

Waterproofing and Damp-proofing Cementitious Slurry

CARPET FLOOR COVERING TRADE SPECIFICATION

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

for the master tradesman Setcrete Product Guide

Sikafloor -161 is an economic, two part, solvent free, low viscosity epoxy resin, suitable for use under hot climate condition.

Coloured Mineral Dry Shake Floor Hardener

Mapei systems for radiating floor heating with high thermal efficiency

Construction. 3-part cement and epoxy combination micro mortar for surface sealing. Product Description 1 1/5. Tests

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

SILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION

Construction. Sikafloor N Elastic. 1-part PUR highly elastic coating. Product Data Sheet Version 29/03/2011(Corporate edition 12/08/2010)

Drying of Concrete TDS 183

PRODUCT DATA CEMENTONE WATERPROOF RAPID SETTING CEMENT FOR INSTALLATION, REPAIR AND MAINTENANCE. Page 1 of 5

METHOD STATEMENT SCREEDING OF FLOOR

PRODUCT DATA SHEET Sikafloor -378

TECHNICAL DATA SHEET AUS-FLEX MULTI

GLUE-DOWN INSTALLATION VIRTUO 30 / 55

Contents. SUPPORTING PRODUCTS UL-Primer 24 Moisture Seal 24 Megalastic 25

CONNOR Control XT Page 1

Installation Guidance Note: Flotex Sheet

RETANOL XTREME HIGH PERFORMANCE SCREED ADDITIVE WITH FAST DRYING TIMES AND HIGH EARLY STRENGTH.

Floors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited

TILING SPECIFICATIONS

Part of the Sikaplan WT Membrane System

MasterSeal M 861 (Formely known as Conipur M 860 Thix)

2-part epoxy primer, levelling mortar and mortar screed

INFORMATION AGILIA HORIZONTAL

Construction. Integral waterproofing compound for concrete and mortar. Product Description. Product Data. Form. Storage.

Construction. Non-metallic Dry Shake Floor Hardener. Product Description. Tests. Product Data. Storage

Liquid applied polyurea hybrid membrane

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

MasterEmaco S 5450 PG

HYBRID. Pre-Laying Checks

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

High viscous (thixotropic) elastic adhesive for wood flooring

ASO -EZ4 Art.-No

Performance Floors for Warehouses and Distribution Centres. Kevin Dare, Managing Director, Face Consultants Ltd.

Single pack, solvent based Polyurethane, used in Balcony 10, 15 and 20 waterproofing systems

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

CIMENT FONDU. Special cement for concrete and mortar solutions

Highly Chemical Resistant Laminate System. Sika Asplit VEL is 2 part, glass fabric reinforced, vinyl-ester based coating and lining system.

High performance shrinkage compensated cementitious grout

Surface Protective Systems

Concrete. Chapter 10 Properties of Fresh Concrete. Materials of Construction-Concrete 1. Wikipedia.org

Construction. 2-part epoxy primer. Product Data

Fields of application

Construction. 3-part cement and epoxy combination mortar for self-smoothening floor screeds of 1.5 to 3 mm. Product Description 1 1/6

26 Visqueen 100% Recycled Ecomembrane 28 Visqueen DPM To Pifa Standard PROOF. membranes

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340

Ground Terraces. bal-adhesives.com. Part B: Installation Guide

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

MasterFlow 980 (Formerly known as Masterflow 980 M)

2-part epoxy self-smoothing and broadcast system

MasterEmaco T545. Rapid setting, high early strength repair mortar based on magnesia-phosphate cement for temperatures from -20 C to >30 C

Garage Conversion - Between and Under Joist Applications

Construction. 2-part epoxy roller and seal coat. Product Description

Floating Floor Constructions

Ribdeck AL STRUX 90/40. efficient designs. with. shallow slabs. fibre reinforced concrete

SIKA WATERPROOFING SYSTEMS SIKA-1 WATERPROOFING SYSTEMS

UNDERSTANDING THE REQUIREMENTS OF GYPSUM CALCIUM SULPHATE ANHYDRITE OR ALPHA HEMIHYDRATE SCREED IN FLOORING AND INSTALLING WOOD FLOORING

SIDER-POOL. Product Data. Features and Uses

Epoxy adhesive EN

Visqueen Building Products Maerdy Industrial Estate Rhymney Tredegar Gwent NP22 5PY Tel: Fax:

Fiber Reinforced Tile and Stone Mortar

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

KEY 9418 MMA BINDER DESCRIPTION KEY ADVANTAGES KEY CONSIDERATIONS COMPOSITION COLOR SELECTION SURFACE PREPARATION

REV:6-30/09/30. Liquid Rubber Timber Specification

POROUS (ABSORBENT) SUBFLOORS. (most wood subfloors and some concrete)

BOLON BY YOU INSTALLATION INSTRUCTIONS ROLLS

FLOORING INSTALLATION PRODUCTS. Flooring Adhesives. Floor Smoothing Underlayments. Waterproof Surface Membranes. Subfloor Preparation Products

2-part, electrostatic conductive epoxy coating

RESILIENT FLOORING: Hot and Heavy - Secoya

Plaster systems. Plaster systems.

REF : WEBSITE08. Monday, 12 December 2011

Product Information. DiamondCoat Polyurethane Concrete Floor Finish Clear, high build, high abrasion resistant, decorative concrete floor coating

2-part epoxy primer, levelling mortar, intermediate layer and mortar screed

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

RESILIENT FLOORING: Select Step Wood

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

1-part polyurethane pourable self levelling floor joint sealant

Plastering. Holiday Inn - Sultanate of Oman

prospec.com Concrete Repair & Restoration

hüma PARKETTSYSTEM GmbH INSTALLATION GUIDE

Concrete Slab-on-Ground

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

ECS. High Strength Concrete. North Harbour Stadium Influences on Concrete Strength Performance. ECS High Strength Concretes

Transcription:

FEATURES promotes rapid drying of floor screeds only 30mm of cover over heating pipes reduces waiting time before laying floor coverings allows early foot trafficking can be purchased and applied by competent flooring contractors minimises site delays and access simple and cost effective can be pumped to raised levels Description RonaScreed Underfloor Heating Screed additive for site batched screeds is used to quickly reduce the level of retained moisture within the screed allowing floor coverings to be laid over the screed much sooner than with conventional screeds. It also promotes high early strength in compression, permitting early access by following trades. RonaScreed Underfloor Heating Screed is supplied in concentrated form and used in low dilution. It provides rapid drying and early laying of floor coverings such as sheet vinyl, tiles, carpet etc. When laying onto insulation the minimum screed thickness is 65mm. Heating pipes require a minimum cover of only 30mm of screed. RonaScreed Underfloor Heating Screed must be applied by competent screeding and floor laying contractors. Drying Time of 50mm screed Time to reach 80% RH (1:3) Time to reach 80% RH (1:4) Time to reach 80% RH (1:5) Time to reach 75% RH (1:3) Time to reach 75% RH (1:4) Time to reach 75% RH (1:5) 4 day 7 days 11 days 8 days 11 days 18 days Drying Time of 75mm screed Time to reach 80% RH (1:3) Time to reach 80% RH (1:4) Time to reach 80% RH (1:5) 8 day 10 days 14 days

Drying Time of 75mm screed (continued) Time to reach 75% RH (1:3) Time to reach 75% RH (1:4) Time to reach 75% RH (1:5) 15 days 15 days 22 days When applied at 65mm the screed will achieve 80% RH at the surface of the screed after 6 days and 75% RH after 12 days based on application and curing at 20 C and good drying conditions. Physical Properties Yield and Coverage When applied at 75mm a RonaScreed Underfloor Heating Screed will achieve 80% RH at the surface of the screed after 8 days and 75% RH after 15 days based on application and curing at 20 C and good drying conditions. Poor drying conditions such as low temperature, high humidity and insufficient air movement will delay drying. If the screed is covered with a curing membrane such as polythene, then the drying time starts when the membrane is removed. The relative humidity (RH) at the surface of the screed should be measured with a hygrometer before proceeding to lay floor coverings; see BS 8203. Note that the screed mix designs are formulated to be covered with carpet, vinyl, tiles or other coverings and are not designed as wearing screeds or toppings. For wearing screeds, Ronafix or RonaScreed Self Smooth Topping should be used. Physical Properties Measuring Surface Drying Compressive Strength (1:3) 1 day 23N/mm² 28 days 44N/mm² Compressive Strength (1:4) 1 day 20N/mm² 28 days 40N/mm² Compressive Strength (1:5) 1 day 18N/mm² 28 days 36N/mm² The above are typical laboratory results @ 20 C. Site strengths will be lower. Mix Design (1:3) By weight (by volume) Portland cement 50kg (1) Medium sharp sand** 150kg (2.5) RonaScreed Underfloor Heating Screed 1 litre Water 15.7 litres approx* Yield 0.09m³ Mix Design (1:4) By weight (by volume) Portland cement 50kg (1) Medium sharp sand** 200kg (3.5)

Mix Design (1:4) (continued) RonaScreed Underfloor Heating Screed Water Yield 1 litre 15.7 litres approx* 0.11m³ Mix Design (1:5) Portland cement 50kg (1) Medium sharp sand** 250kg (4.25) RonaScreed Underfloor Heating Screed 1 litre Water 16.7 litres approx* Yield 0.137m³ * add diluted RonaScreed Underfloor Heating Screed to cement and sand to achieve working consistency ** mix designs are based on dry sand and aggregate. The amount of water added to the screed should be adjusted accordingly. Overdosing with RonaScreed Underfloor Heating Screed will not improve drying and may even extend drying times. Estimating Guide 1:3 Mix Required per m² @ 50mm Required per m² @ 75mm Required per m³ 1:4 Mix Required per m² @ 50mm Required per m² @ 75mm Required per m³ 1:5 Mix Required per m² @ 50mm Required per m² @ 75mm Required per m³ 0.55 litres 0.825 litres 11 litres 0.44 litres 0.66 litres 9 litres 0.36 litres 0.54 litres 7.3 litres Drying and Hardening Floor screeds incorporating RonaScreed Underfloor Heating Screed dry out more quickly than unmodified screeds and will generally accept foot traffic after 24 hours only. Vinyl floor coverings and tiles can be laid over a RonaScreed Underfloor Heating Screed surface as soon as 12 days after laying (for a 65mm screed). The durability and hardness of a RonaScreed Underfloor Heating Screed floor is superior to standard floor screeds due to its high density, compressive strength and impact resistance. Mix Components and Design The basic components of a RonaScreed Underfloor Heating Screed systems are cement (BSEN197-1 CEMII), sand from grade C or M of table 5 of BS882, RonaScreed Underfloor Heating Screed and clean water. The water content shown in mix designs must be adhered to; the use of insufficient

Mix Components and Design (continued) water will fail to fully hydrate the cement and will produce a lower performance screed. Aggregate Water Content If damp sand is used the amount of water should be adjusted accordingly. RonaScreed Underfloor Heating Screed mix 1 gives a water/cement ratio of 0.29 and yields approximately 0.1m 3. This mix design can be leaned out to 1:4 or 1:5 (cement : sand) by weight if preferred, but strength will be reduced and the screed will take longer to dry. Instructions for Use Surface Preparation The surface on to which RonaScreed Underfloor Heating Screed is to be applied must be clean and the insulation board must be appropriate for the application, joints must be taped.. Mixing RonaScreed Underfloor Heating Screed must be mixed using a forced action mixer to ensure full dispersion of the contents. Dry mix the cement and sand then dilute RonaScreed Underfloor Heating Screed with 5-8 litres of clean water and add to the mix. Add more clean water as required to achieve the correct gauging liquid content. The screeder should be able to make a ball of the mixed mortar and pull it apart without crumbling of the mortar. The mix must not be overdosed with RonaScreed Underfloor Heating Screed liquid. Laying Standard screeding practices should be followed. The mortar must be placed as soon as possible after mixing and well consolidated. Conventional tools such as float and trowel are used to obtain the desired surface finish. Joints Isolation joints should be installed around the perimeter of the floor, in doorways and around columns, manholes and other fixed elements. Bay proportions should preferably not exceeded 2:1 length to width ratio, to limit uneven curing stresses. Where separate heating zones occur within the same floor area, a joint must be positioned in the screed between the zones. Curing Curing must commence as soon as possible after finishing the screed. Cure the screed with tight fitting polythene, placed on to the screed as early as possible without damaging the surface. Cover for 24 hours then remove and air cure. Pumping RonaScreed Underfloor Heating Screed modified screeds can be pumped to the point of laying. Tests have been conducted using Putzmeister equipment and specific guidance should be sought from Ronacrete Ltd.

Contractors Unlike other screeds of a similar nature RonaScreed Underfloor Heating Screed can be purchased and applied by competent screeding contractors throughout the country. The use of RonaScreed Underfloor Heating Screed is simple and straightforward and satisfactory performance will be achieved provided the correct methods are followed. There are obvious advantages in selecting a contractor who has previous experience of the material but if requested the Ronacrete Technical Department will provide guidance and assistance to other contractors. Ronacrete Ltd maintains a list of national and local contractors who are familiar with this type of flooring system and their application procedure. Other Flooring Materials Depending on the specific requirements of the floor system being laid Ronacrete may recommend an alternative product and specification which may be more suited to the application. To discuss the use of Ronacrete materials for any application please contact the Ronacrete Technical Department for full technical and practical guidance at design and specification stage together with site assistance and practical backup. Packaging RonaScreed Underfloor Heating Screed is supplied in 20 and 210 litre units. Shelf Life and Storage Shelf life in unopened containers is 9 months. Store in a cool dry place. Protect from frost. Health and Safety RonaScreed Underfloor Heating Screed is non-flammable and harmful by ingestion. Prolonged contact with skin should be avoided. Any splashes should be washed well with water. If contact with eyes occurs wash thoroughly with water and seek medical advice. Site Attendance When on site Ronacrete representatives are able, if asked, to give a general indication of the correct method of installing a Ronacrete product. It is important to bear in mind that Ronacrete Ltd is a manufacturer and not an application contractor and it is therefore the responsibility of the contractor and his employer to ensure he is aware of and implements the correct practices and procedures to ensure the correct installation of the product and that liability for its correct installation lies with the contractor and not with Ronacrete Ltd.

0836 Ronacrete Ltd, Flex Meadow, Harlow Essex, CM19 5TD, UK 13 0836-CPR-13/F043 BS EN 934-3 Admixtures for Masonry Mortar Product: RonaScreed Underfloor Heating Screed Chloride ion content: < 0.1% Dampness Test: 75% RH at 20C at 15 Days 75mm depth of 1:3 cement / sand mix The information detailed in this leaflet is liable to modification from time to time in the light of experience and of normal product application, and before using, customers are advised to check with Ronacrete Ltd, quoting the reference number, that they possess the latest issue. Any person or company using the product without first making further enquiries as to the suitability of the product for the intended use does so at his own risk, and Ronacrete Ltd can accept no responsibility for the performance of the product, or for any loss or damage arising out of such use. RONL 691 Issue 2 6th November 2013 Ronac House, Flex Meadow, Harlow, Essex CM19 5TD, U.K. Tel: +44 (0)1279 638700 www.ronacrete.co.uk technical@ronacrete.co.uk