QCI HEP Pre Exam Quiz

Similar documents
Quality Control Inspection Checklist. WX Contractor: BWR: Yes / No DCF: Yes / No Work Order: Yes / No

Questar ThermWise Duct Technical Specifications

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

Retrofit Installer / Shell

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

10 Steps to Save Energy in Your House

Low-Income Energy Savings Program. Program Guidelines

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Connecticut 2011 Baseline Study of Single-Family Residential New Construction. Final Report

Hardin County Planning and Development Commission

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

ENERGY AUDITOR STUDY GUIDE

Boulder City NV Prepared by (Print Name) Signature Date

Home Energy Assessment Rebate Guide

Crawl Space Moisture Control

Compliance Certificate

NEW HOMES PROGRAM 2017 PROGRAM GUIDE

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

Crawl Spaces and Basements: Defining the Building Envelope

Guidelines for Measures & Strategies Wall Air Sealing & Insulation Methods in Existing Homes

HOUSING ENERGY- EFFICIENCY INSPECTION FIELD MANUAL

Home Energy Savings Program. Utah Participating Weatherization Trade Ally Program Manual

W02 Designing a Priority List

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Radon Vent Pipe System. Labeling Performance Indicators

2012 CLEAResult All rights reserved. Residential Energy Efficiency

Home Efficiency Program Installation Standards: V8 Effective: 4/13/2014

Encapsulated, Sealed & Closed Crawlspace Installation Manual

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Chapter 2: Foundation

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

2017 SPECIFICATIONS MANUAL ENERGY TRUST OF OREGON EXISTING HOMES

Energy Efficiency Programs

NB Power s Home Insulation Energy Savings Program as of August 1, PROGRAM INTRODUCTION PROGRAM OVERVIEW ELIGIBILITY...

For building inspections

AEP Ohio IN-HOME ENERGY PROGRAM Scoring Methodology for QAQC Scoring System Version 1.1 2/3/15

Energy Audits. Presented By. Eugene Hoyt Professional Inspector TREC # IECC Energy Inspector/Plans Examiner ICC #

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

COAD Ohio Weatherization Training Center Course Overview

The ENERGY DETECTIVE. Where Is Your Home Losing Money? Find out with The Energy Detective Call Home Energy Analysis Program

Presented by The National Association of Certified Home Inspectors Chicago Chapter

Introduction to Building Envelope Analysis

ENERGY EFFICIENCY CERTIFICATION

San Diego Gas & Electric Residential Whole House Retrofit Programs. Quality Assurance & Quality Control Plan

Homes. Plan Review Input Form. Office Use: P l an Rev iew Contro l Nu mb er

The Energy Audit National Weatherization Training Conference Priority Lists Experiences and Impacts Nick Milano

Michigan Energy Code Training and Implementation Program

Plan Check & Field Inspection Guide

2017 Program Manual Home Energy Solutions

2012 IECC Residential with State Adopted Changes

HPW Protocol Reference Manual

AGREEMENT CONCERNING EXISTING AS BUILT CONSTRUCTION

NW Natural Washington Residential, Contractor Install

Passive House II, The Design Process. Ray Rebilas, AIA - Kitchen & Associates. Harry Moody - Pennrose Properties. Mike Ferguson - S.B.

THE ILLIANA HOME INSULATION GUIDE

Quality Control Inspection of Homes with Thermal Imaging

LIMITED POTENTIALLY HAZARDOUS MATERIAL BUILDING INSPECTION REPORT AND ASBESTOS BUILDING INSPECTION REPORT. for

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

Vermont Residential Building Energy Code. Handbook

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

Michigan Energy Code Training and Implementation Program

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Sample Home Inspection

Document Title: Doc No: FRM B4-59 Rev No: Page: Of: Thermal Insulation Program Certification Report

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Advanced Ventilation for Residential applications FBC Res 2010.

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

PRE-FABRICATED HOUSING

The Inspection Process. Waxhaw N.C.

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

The Numerous Benefits of Energy Efficient Practices

Cellulose Insulation Products. Date: Submitted to: Submitted by: Job Reference: Job Name

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

Inspection Report. 1 of 8

Green Building Standards Implementation Plan. Version 01

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002

DUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

Inspection of New One- and Two- Family Dwellings

2018 Program Manual Home Energy Solutions

General Residential Code Requirements

New Hampshire Residential Energy Code

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Title 24 HERS Certification Training 2016 Guide to HERS Verification of Existing Conditions

ASHRAE 62.2: What s New in 2016

Construction Report NYSERDA Residential Performance Challenge

Notice. Privacy Act. Klickitat PUD 1313 S. Columbus Ave. Goldendale, WA (509) or (800) Privacy Act Notice:

Structural. Orientation of the Home. Northeast Oklahoma REC s Energy Efficient Tips for Home Builders

Energy Audits, Improvements In Small Ofice Buildings

Appendix. Home Heating Analysis Worksheet. Introduction. Directions C-1

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

G. Warren, Inc. Metuchen, NJ Definitions

Insulation Inspection Procedures. Inspection Requirement? Insulation Inspection Procedures. Assessment: Grade I. Boundary condition for Grade I

Transcription:

QCI HEP Pre Exam Quiz 1. When spraying two part foam the technician's BEST choice for respiratory protection is a: a) Full face respirator with p 100 filters b) Filtering face piece c) Full face or hood supplied air respirator d) Half face respirator with a VOC cartridge 2. According to ASHRAE 62.2 2013, a full bathroom with a fan moving this amount of air would require no additional ventilation added using the alternative compliance ventilation method, as long as there was an operable window: a) 20 CFM b) 50 CFM c) 15 CFM d) 30 CFM 3. According to NFPA 54, what is the minimum required volume for a combustion appliance zone housing a natural draft atmospheric furnace and water heater totaling 120,000 BTUH input? a) 50,000 ft3 b) 12,000 ft3 c) 6,000 ft3 d) 4,200 ft3 4. An appropriate energy efficiency measure can be defined as: a) Whatever your experience tells you will save energy in a given home. b) A measure recommended by the program approved audit or priority list. c) Attic insulation if there is R 10 or less existing. d) Refrigerator replacement if existing unit is over 7 years old. 5. During a final inspection you determine the attic hatch was not installed according to program requirements and looks very sloppy. The client complains. Your BEST course is to: a) Deduct the price of the attic hatch from the contractor's reimbursement. Issue a re work and re bid the attic hatch. b) Immediately call the crew leader and have the client explain the problem. Assign a re work order. c) Contact your supervisor to get a re work order in process. Inform the client that things will proceed according to program regulations. d) Assure the client the work will be fixed, and contact the crew leader as soon as possible to assign the re work order.

6. During a final inspection your blower door reading shows you the house needs additional air sealing. To help identify where air sealing efforts should focus, you conduct zone pressure diagnostics, starting with the house to attic. With the house at 50 WRT outside, you measure 45 in the house WRT the attic. This tells you: a) Wall cavities are connecting the basement to the attic. Seal at the top and bottom to achieve target blower door number. b) The ceiling is leaking more to the attic than the attic is to outside, indicating air sealing the ceiling/attic floor will be highly effective. c) Dropped soffits were not addressed, and are connecting the attic with the living space. Air sealing those is a high priority. d) The ceiling is acting as a suitable air barrier. You will test other zones to locate major air leaks. 7. During an in progress inspection you find an installer standing on the client's dryer to access the attic hatch. As the quality control inspector, your best response is to: a) Order the installer to climb down and provide your phone number to the client to call you if any more situations like this occur. b) Loudly berate the installer so the client can hear that you are against such practices. c) Say nothing to the installer, but call the installer's supervisor and report the incident. d) Assist the installer in moving the dryer and positioning a ladder for safe access, and, during a break, raising the issue of professional conduct and respect for client 8. During an in progress inspection you find that the auditor mis identified the building envelope and the installers are not insulating a wall between the conditioned and unconditioned space, a living room and enclosed porch. They are also not insulating the walls of the enclosed but unconditioned porch. They will complete wall insulation this afternoon, according to their schedule. Your best response is to: a) Assume the auditor had a good reason of omitting this wall from the insulation measure and not mention it again. b) Say nothing at the moment, but write up the error in your report, knowing that the crew will return and finish the job appropriately. c) Contact your supervisor to get a verbal okay, follow the procedure for change orders, and then inform the crew of the added area to be installed. It is up to them to complete today or return later. d) Contact the energy auditor and make him/her start the process for a change order. Leave the crew undisturbed. 9. During an in progress inspection, which of the following BEST describes your scope of evaluation?

a) Worker professionalism and safety; Cleanliness of home; Distance to nearest public restroom b) Client satisfaction with in progress work; Worker professionalism and safety; Workmanship of installed measures c) Workmanship of installed measures; Crew's system of tools and materials accounting; Number of residents present during work d) Cleanliness of home; Client satisfaction with in progress work; Workmanship of crews 10. The amount of water vapor contained in a given volume of air compared to the total amount of water vapor it is capable of containing is called: a) Relative humidity b) Dew point c) Condensation d) Wet bulb 11. During the final inspection, which of the following is NOT a necessary part of the quality control inspector's job? a) Convene a meeting with client, auditor and crew leader to discuss job outcomes and get client sign off. b) Question the client about satisfaction with the entire process and include in the report. c) Verify the work was installed according to the work order through visual/sensory and diagnostic evaluations. d) Acquire client satisfaction sign off and retain form in client file. 12. During the final inspection client interview, aside from conducting relevant client education, your primary purpose is to: a) Provide material for companies and products that may meet future client needs. b) Evaluate client satisfaction. c) Verify client program eligibility. d) Acquire signed waiver from client, in the case of future problems. 13. Once you have set up worst case draft conditions, which appliance do you fire first to conduct worst case CAZ depressurization tests? The appliance with the: a) Longest flue distance from chimney b) Highest BTU capacity c) Smallest diameter flue pipe d) Lowest BTU capacity 14. Testing individual return and supply ducts with a pressure pan helps determine what? a) Location of leakage areas in the ductwork b) Overall leakage from ducts to the home

c) Whether the ducts are blocked or constrained d) Effective R value for insulated ducts 15. The audit for a home you are inspecting indicates the unfloored attic was previously uninsulated, and the work order specified insulating to R 30, which adheres to your program requirements. During final inspection you discover that about 1/2 of the attic had existing R 13 batt insulation, which the installers left in place and blew over with another R 30 of cellulose. You conduct blower door and IR testing to determine the insulation is effective where blown over the batts. You will: a) Deduct the cost of the cellulose that brought the R value higher than R 30 for half the attic from the contractor reimbursement. b) Make a note of the discrepancy in the client file, and include in your report the inaccuracies in the initial audit. c) Contact the crew leader to request cost effectiveness justification for the cellulose which effectively brought half of the attic above R 30. d) Create a change order, have the crew return, remove the fiberglass batts and rake the cellulose smooth before signing off on the job. 16. The program you are working for requires you maintain EPA's Lead Renovation, Repair and Painting (RRP) Certified Renovator certification. What is the bare minimum you must do to acquire and maintain the certification? a) Take the 8 hour course, written and hands on tests, and acquire 35 Continuing Education Units (CEUs) every 5 years. b) Challenge and pass the exam, and acquire 35 Continuing Education Units (CEUs) every 3 years. c) Take the 8 hour course, written and hands on tests, then take a refresher course every 5 years. d) Take the 8 hour course, written and hands on tests, and then acquire 35 Continuing Education Units (CEUs) and take a refresher course every 5 years. 17. The temperature difference between the evaporator and the compressor inlet on a cooling unit is called: a) Supercooling b) Subcooling c) Superheat d) Expansion ratio 18. Which of the following is NOT typically a critical component of the client file? a) Copy of client driver s license b) Verification of client eligibility for the program c) Client satisfaction and sign off form d) Work scope and/or job order documents

19. Which of the following pieces of information regarding the exterior of a home should be collected during an inspection in order to analyze the home s energy consumption? a) Proper closure of garage door b) Standing water around the crawlspace c) Presence of gutters d) Number of windows 20. While reviewing the required paperwork for a recently completed project you notice that a new exterior door was on the work order but not noted in the contractor invoices or your final inspection report. Your BEST course of action is to: a) Call the client to schedule another final inspection to verify the door wasn t replaced and move forward accordingly. b) Call the client to determine if the door replacement is desired and move forward accordingly. c) Call the responsible contractor to determine why the door was not replaced and move forward accordingly from there. d) Sign off on the paperwork, including a note about the door. 21. You are at a job where no work was done in the attic. Existing insulation levels were adequate, and no additional venting was needed. During your final inspection you: a) Since no work was conducted in the attic, mark "N/A" on the final inspection form and move on to the next item. b) Ask the homeowner to verify the pre retrofit insulation characteristics noted in the audit form. Have them sign off and include this form in the client file. c) Confirm with the crew leader that no work was done in the attic. Contact the auditor to verify the pre audit numbers and sign off on the job after all other work is inspected. d) Access the attic and verify the pre retrofit insulation levels as noted in the audit form and spot check ventilation and high temperature flues running through the attic. 22. You are closing out a project in which there have been a number of re works, but everything was ultimately completed as required. Which of the following BEST describes what you should include in your job file? a) All official documentation, including client sign off sheet, and any handwritten or other notes you kept to track the anomalies. b) The original work order, change orders and contractor invoices. c) Original audit, work order and client sign off sheet. d) All official documentation, the original audit, change orders and the client sign off sheet.

23. You are final inspecting a job that included replacing an unsafe gas water heater with a new, natural draft water heater. What is the required slope for the vent connector from the water heater to the main chimney? a) 1" per horizontal foot. b) 1/2" per horizontal foot. c) 4" per horizontal foot. d) 1/4" per horizontal foot. 24. You are inspecting for a program that requires measures be installed in the order of cost effectiveness to be eligible for contractor reimbursement. The initial audit shows the home was eligible for complete wall dense pack insulation installation according to program requirements. Lower down the priority list, windows are listed as cost effective, though not as effective as the wall insulation. At final inspection you see that all the windows have been replaced, but the walls were not insulated. The client explains during the client interview that the contractors said all the program funds had been used up installing windows and they could do no more. You: a) Explain to the client that the program reimbursement requirements have not been met, and she will have to pay for the windows. b) Reimburse the contractor for the windows, and issue a re work for the higher priority measures to be installed within a given time frame. c) Contact your direct supervisor and have this contractor removed from the roster. Provide the client with contact information for insulation contractors in the area. d) Contact the crew leader and instruct them to install wall insulation and other higher priority measures before being reimbursed for the windows. 25. You are traveling near an in progress job and decide to drop by for a spot check. Which of the following would it NOT be appropriate to request from workers on site? a) Safety Data Sheets for materials being used on the job site b) Worker credentials c) Program eligibility of homeowner d) Work order and any change orders

Quiz Key 1 C 2 D 3 C 4 B 5 D 6 D 7 D 8 C 9 B 10 A 11 A 12 B 13 D 14 A 15 B 16 C 17 C 18 A 19 D 20 C 21 D 22 A 23 D 24 D 25 C