VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant

Similar documents
THERMOFIT RNF-100 TUBING Polyolefin, Flexible, Heat-Shrinkable

SPECIFICATION RW-2514 Document Number NBC MARKER SYSTEM (Ladder Form) NBC-SCE

THERMOFIT ADHESIVE S Flex Fluid Resistant, High Temperature, One Part-Flexible Epoxy

Heat-Shrinkable Tubing

Shrink-Kon Thin Wall Heat Shrinkable Tubing

RBK-ILS-125 SCOPE. This Quality Assurance Specification establishes the quality standard for RBK-ILS-125.

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

MATERIAL SPECIFICATION RIGID FOAM; CLOSED CELL POLYMETHACRYLIMIDE (PMI)

MILITARY SPECIFICATION. PLASTIC MOLDING and EXTRUSION MATERIAL, POLYETHERETHERKETONE (PEEK)

UL RATED HEAT SHRINK TUBING

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

Specifications for Concrete Embedment Liner

Single core conductor BETAtherm 145

ZZ-M-71F February 26, 1987 SUPERSEDING ZZ-M-71E May 3, 1979 FEDERAL SPECIFICATION MATTING, RUBBER AND VINYL

UNI-BELL PVC PIPE ASSOCIATION UNI-B-15-10

Heatshrink & Cable Repair Solutions

FLAME RETARDANT POLYPROPYLENE SHEET

P.V.C. INSULATED UNARMOURED COPPER CABLES

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

PART UF REQUIREMENTS FOR PRESSURE VESSELS FABRICATED BY FORGINGS

4Molded Parts. Molded Parts. Table of Contents

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

*** Supercedes: BECO E and COM , , & ***

PMG LISTING CRITERIA FOR MULTILAYER PIPE AND FITTINGS ASSEMBLY FOR REFRIGERANT APPLICATIONS LC1036

Mar11 Rev B

Product Specification JUL 14 Rev. A1

Evaluation of Polypropylene Drainage Pipe Manufacturers

DATA SHEET A5000 RELEASE FILM

Feb12 Rev D

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

GUIDE SPECIFICATION: DUCT LINER

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. March 16,

FRP Floor Panels Standard Specification

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

Single-Jacketed Tubing


Quality Standard for ACR Copper Tubes in LWC

COMMERCIAL ITEM DESCRIPTION FITTINGS FOR CABLE, POWER, ELECTRICAL AND CONDUIT, METAL FLEXIBLE

Heritage Quality Performance

Table of Contents. Applications...3. Extruded Sizes...7. Value Added Services Heat Shrinkable Extrusions Technical Information...

HEAT SPREADERS. Heat Spreaders. and C-Wing

DuPont Kapton HPP-ST

HOSTAFORM C 9021 GV1/30 POM Glass Reinforced

Standard Specification for Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series) 1

Mar11 Rev C

WIRES AND CABLES, ELECTRICAL, 600V, LOW FREQUENCY. ESCC Generic Specification No. 3901

PRODUCT SPECIFICATIONS

SMPM Female Cabled Connectors

WELDING PROCEDURE SPECIFICATION. Shielded Metal Arc Welding-SMAW

MODULAR PAVER DETECTABLE/TACTILE WARNING SURFACES

MECHANICAL AND PHYSICAL PROPRIETIES

DRISCOPLEX 6500 Series

Installation Practice InnerSeal

TECHNYL C 50H2 NATURAL

VECTRA A150 LCP Glass Reinforced

Table of Contents. Applications...3 Medical...4 Industrial...5

3M Electrical, Electronic and EMI Shielding Tapes Selection Guide

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

DRAFT DOCUMENT FOR INDUSTRY CONSENSUS REVIEW ONLY

Specification for Drill Pipe

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Section Domestic Water Piping (Hot and Cold Water Potable Water Distribution)

AEROSPACE MATERIAL SPECIFICATION

Double Coated Urethane Foam Tapes

C900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI. GRI Standard GM19a*

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

Standard Specification for Seamless and Welded Steel Pipe for Low-Temperature Service 1

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

QQ-A-250F September 25, 1978 SUPERSEDING QQ-A-250E October 19, 1970 (See 6.3) FEDERAL SPECIFICATION

INTERNATIONAL STANDARD

Ph: Fax Web: East Philadelphia Street Ontario, California USA

Double Coated Urethane Foam Tapes

Innovative, Thermally Conductive Silicone Solutions for LED Lighting

HOSTAFORM C POM Unfilled

RTV627 silicone rubber compound is dark gray in color and has an easily pourable viscosity of about 1300 cps.

MILITARY SPECIFICATION COATING COMPOUND, SYNTHETIC RUBBER, FOR EXPOSED STEEL SURFACES

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION

GRI - GM17 Standard Specification*

SECTION DETECTABLE/TACTILE WARNING SURFACES

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

PMG LISTING CRITERIA FOR PERT-AL-PERT PIPE AND FITTINGS FOR REFRIGERATION APPLICATIONS LC1039. Approved Date: November 2015 PREFACE

SPECIA LT Y SEA LANT S

Mar11 Rev B

Sample Bid Specification Revision 2 PVC Expanded-in-Place Pipeline Reconstruction

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED

insulate Seal Protect Single Wall ProductS

1. Cast-in-place concrete is specified in Section

DuPont Kapton FPC POLYIMIDE FILM

Pig s Tail. protective wrapping. use pig s Tail for:

INDUSTRIAL ATTACK 800

G SPECIFICATION: EXTRUDED POLYOLEFIN COATING ON STEEL GAS PIPE VOLUME: 6. REVISION: (See ) 6/17/14 5 Years

INTERNATIONAL STANDARD

Transcription:

TE Connectivity 300 Constitution Drive Menlo Park, CA 94025 USA Raychem Tubing Specification This Issue: Date: Replaces: RW-3023 Issue 9 Nov 21, 2016 Issue 8 VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant 1. SCOPE This specification covers the requirements for one type of flexible electrical insulating, extruded tubing whose diameter will reduce to a predetermined size upon the application of heat in excess of 90 C (194 F). The tubing is free of polybrominated biphenyls (PBB) and polybrominated biphenyl oxides (PBBO). VERSAFIT V2, a standard wall 125 C, VW-1 rated, UL recognized tubing meeting the requirements of UL 224. VERSAFIT V2 also meets the requirements of Standard C22.2 No. 198.1 and is CSA certified. VERSAFIT V4, a thin wall very flexible 125 C, 300 volt, VW-1 rated, UL recognized tubing meeting the requirements of UL 224. VERSAFIT V4 also meets the requirements of Standard C22.2 No. 198.1 and is CSA certified with a 150 volt rating. 2. APPLICABLE DOCUMENTS This specification takes precedence over documents referenced herein. Unless otherwise specified, the latest issued of referenced documents applies. The following documents form a part of this specification to the extent specified herein. 2.1 UNDERWRITERS LABORATORIES, INCORPORATED UL Subject 224 Extruded Insulating Tubing (Copies of UL publication may be obtained from Underwriters Laboratories, Inc., 1285 Walt Whitman Road, Melville, Long Island, New York 11746.) 2.2 CANADIAN STANDARDS ASSOCIATION C22.2 No. 198.1 Extruded Insulating Tubing (Copies of CSA publications may be obtained from Canadian Standards Association, 1897 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3.) 2.3 OTHER PUBLICATIONS ISO 846 Plastics-Evaluation of the action of microorganisms (Copies of ISO publications may be obtained from the International Organization for Standardization, 1, rue de Varembé, CH-1211 Geneva 20, Switzerland or via the ISO website at http://www.iso.ch/iso/en/isoonline.frontpage) American Society for Testing and Materials (ASTM) Standard Methods of Testing Heat-Shrinkable Tubing for Electrical Use (Copies of ASTM publications may be obtained from the American Society for Testing and Materials, 1916 Race Street, Philadelphia, Pennsylvania 19103.).

Page 2 SPECIFICATION RW-3023 ISSUE 9 3. REQUIREMENTS 3.1 MATERIAL The tubing shall be fabricated from thermally stabilized, flame-retardant, modified polyolefin and shall be crosslinked by irradiation. It shall be homogeneous and essentially free from flaws, defects, pinholes, bubbles, seams, cracks and inclusions. 3.2 PROPERTIES The tubing shall meet the requirements of Table 3. 3.3 COLOR The tubing shall be available in black, white, red, yellow, blue, green, brown, orange, violet and gray. 4. QUALITY ASSURANCE PROVISIONS 4.1 CLASSIFICATION OF TESTS 4.1.1 Qualification Tests Qualification tests are those performed on tubing submitted for qualification as a satisfactory product and shall consist of all tests listed in this specification. 4.1.2 Acceptance Tests Acceptance tests are those performed on tubing submitted for acceptance under contract. Acceptance tests shall consist of the following: Dimensions Longitudinal Change Tensile Strength Ultimate Elongation 4.2 SAMPLING INSTRUCTIONS 4.2.1 Qualification Test Samples Qualification test samples shall consist of 15m (50 feet) of tubing of the size and color specified. Qualification of one size or color shall qualify all sizes and colors. 4.2.2 Acceptance Test Samples Acceptance test samples shall consist of not less than 5m (16 feet) of tubing selected at random from each lot. A lot shall consist of all tubing of the same size from the same production run and offered for inspection at the same time. 4.3 TEST PROCEDURES Unless otherwise specified, tests shall be performed on specimens which have been fully recovered by conditioning in accordance with 4.3.1 Prior to all testing, the test specimen (and measurement gauges, when applicable) shall be conditioned for 3 hours at 23 ± 3 C (73 ± 5 F) and 50 ± 5 percent relative humidity. All ovens shall be of the mechanical convection type in which air passes the specimens at a velocity of 30-60m (100 to 200 feet) per minute.

SPECIFICATION RW-3023 ISSUE 9 Page 3 4.3.1 Dimensions and Longitudinal Change Three 150mm (6 inch) specimens of tubing, as supplied, shall be measured for length, to an accuracy of ± 1 mm (±1/32 inch) and inside diameter in accordance with. The specimens then shall be conditioned for 3 minutes in a 200 ± 3 C (392 ± 5 F) oven, removed from the oven, cooled to 23 ± 3 C (73 ± 5 F), re-measured for length, inside diameter and wall thickness in accordance with. The longitudinal change shall be calculated as follows: C = L 1 - L0 L0 x 100 Where: C = Longitudinal Change (percent) L0 = Length Before Conditioning [mm (inches)] L1 = Length After Conditioning [mm (inches)] 4.3.2 Tensile Strength and Ultimate Elongation The tensile strength and ultimate elongation of the tubing shall be determined in accordance with using 25mm (1 inch) bench marks and a 25 mm (1 inch) initial jaw separation. The speed of jaw separation shall be 500 ± 50 mm (20 ± 2 inches) per minute. 4.3.3 Secant Modulus The secant modulus of the tubing shall be tested using tubing as supplied in accordance with. 4.3.4 Copper Stability Three 150mm (6 inch) specimens of tubing shall be slipped over a snug filling, straight, clean, bare copper conductor. For tubing sizes 1/4 and smaller a solid conductor shall be used; for tubing sizes 3/8 and larger a solid or tubular conductor shall be used. The specimens on the conductors shall be conditioned for 24 hours in a desiccator or similar humidity chamber at 90 to 95 percent relative humidity and 23 ± 3 C (73 ± 5 F) (three specimens shall be conditioned for 7 days in 158.0 ± 1.0 C (316.4± 1.8 F) oven. After conditioning, the specimens shall be removed from the oven and cooled to 23 ± 3 C (73 ± 5 F). The copper conductor then shall be removed from the tubing, the tubing and conductor shall then be examined. Darkening of the copper due to normal air oxidation shall not be cause for rejection. The tubing then shall be conditioned at room temperature for 16 to 96 hours and tested for ultimate elongation in accordance with 4.3.2. 4.3.5 Dielectric Withstand, Breakdown and Strength The dielectric strength of the tubing shall be measured under oil in accordance with. Five 150mm (6 inch) specimens of tubing shall be recovered over a metal mandrel by conditioning for 3 minutes in a 200 ± 3 C (392 ± 5 F) oven. The mandrel diameter shall be slightly larger than the fully recovered inside diameter of the tubing being tested. The metal mandrel shall serve as one electrode and a 25mm (1 inch) wide strip of lead foil wrapped around the outside of the tubing as the other electrode. The test voltage shall be applied at a rate of rise of 500 volts per second. Thickness measurements for calculating dielectric strength shall be made adjacent to the point of breakdown. Specimens for dielectric withstand shall be held for 60 seconds at 2500 volts. 4.3.6 Corrosive Effect Three specimens of tubing shall be tested for copper contact corrosion in accordance with, Procedure B. Three specimens shall be conditioned for 7 days in a 158.0 ± 1.0 C (316.4 ± 1.8 F) oven. After conditioning, the specimens shall be visually examined for evidence of corrosion. 4.4 REJECTION AND RETEST Failure of any samples of tubing to conform to any one of the requirements of this specification shall be cause for rejection of the lot represented. Tubing which has been rejected may be replaced or reworked to correct the defect and then resubmitted for acceptance. Before resubmitting, full particulars concerning the rejection and the action taken to correct the defect shall be furnished to the inspector.

Page 4 SPECIFICATION RW-3023 ISSUE 9 5. PREPARATION FOR DELIVERY 5.1 FORM The tubing shall be supplied on spools, unless otherwise specified. 5.2 PACKAGING Packaging shall be in accordance with good commercial practice. 5.3 MARKING Each container of tubing shall be permanently and legibly marked with the size, quantity, manufacturer's identification, specification number, product designation and lot number. TABLE 1 V2 TUBING DIMENSIONS, METRIC As Supplied (mm) As Recovered (mm) Inside Diameter Wall Thickness Inside Diameter Wall Thickness Size nominal maximum minimum 0.8/0.4 1.2 ± 0.2 0.2 0.4 0.33 1.0/0.5 1.5 ± 0.2 0.2 0.5 0.33 1.5/0.75 2.1 ± 0.2 0.2 0.75 0.36 2.0/1.0 2.6 ± 0.2 0.25 1.0 0.43 2.5/1.25 3.1 ± 0.2 0.25 1.25 0.43 3.0/1.5 3.6 ± 0.2 0.25 1.5 0.43 3.5/1.75 4.1 ± 0.3 0.25 1.75 0.43 4.0/2.0 4.6 ± 0.3 0.25 2.0 0.43 5.0/2.5 5.6 ± 0.3 0.3 2.5 0.56 6.0/3.0 6.6 ± 0.3 0.3 3.0 0.56 7.0/3.5 7.6 ± 0.3 0.3 3.5 0.56 8.0/4.0 8.6 ± 0.3 0.3 4.0 0.56 9.0/4.5 9.6 ± 0.3 0.3 4.5 0.56 10.0/5.0 10.4 ± 0.3 0.3 5.0 0.56 11.0/5.5 11.4 ± 0.3 0.3 5.5 0.56 12.0/6.0 12.7 ± 0.3 0.3 6.0 0.56 13.0/6.5 13.5 ± 0.3 0.35 6.5 0.66 14.0/7.0 14.4 ± 0.4 0.35 7.0 0.68 15.0/7.5 15.7 ± 0.4 0.35 7.5 0.68 16.0/8.0 16.9 ± 0.4 0.35 8.0 0.68 18.0/9.0 19.0 ± 0.4 0.4 9.0 0.76 20.0/10.0 21.4 ± 0.4 0.4 10.0 0.76 22.0/11.0 23.2 ± 0.4 0.45 11.0 0.89 25.0/12.5 26.8 ± 0.4 0.45 12.5 0.89 27.0/12.5 28.2 ± 0.5 0.45 12.5 0.89 28.0/14.0 30.0 ± 0.5 0.45 14.0 0.89 30.0/15.0 32.1 ± 0.5 0.45 15.0 0.89

SPECIFICATION RW-3023 ISSUE 9 Page 5 TABLE 2 V4 TUBING DIMENSIONS, METRIC As Supplied (mm) As Recovered (mm) Inside Diameter Wall Thickness Inside Diameter Wall Thickness Size nominal maximum minimum 0.4/0.2 0.7 ± 0.2 0.1 0.22 0.187 0.6/0.3 0.95 ± 0.25 0.1 0.3 0.187 0.8/0.4 1.2 ± 0.25 0.1 0.4 0.25 1.0/0.5 1.4 ± 0.25 0.1 0.5 0.25 1.5/0.75 1.9 ± 0.25 0.1 0.75 0.25 2.0/1.0 2.3 ± 0.25 0.1 1.0 0.25 2.5/1.25 2.8 ± 0.25 0.15 1.25 0.25 3.0/1.5 3.3 ± 0.25 0.15 1.5 0.25 3.5/1.75 3.8 ± 0.25 0.15 1.75 0.25 4.0/2.0 4.4 ± 0.25 0.15 2.0 0.25 5.0/2.5 5.5 ± 0.25 0.15 2.5 0.25 6.0/3.0 6.5 ± 0.4 0.15 3.0 0.28 7.0/3.5 7.5 ± 0.4 0.15 3.5 0.28 8.0/4.0 8.5 ± 0.4 0.15 4.0 0.28 9.0/4.5 9.5 ± 0.4 0.15 4.5 0.28 10.0/5.0 10.5 ± 0.5 0.15 5.0 0.28 V4 TUBING DIMENSIONS, USA CUSTOMARY AS SUPPLIED RECOVERED Inside Diameter Inside Diameter Wall Thickness Size Minimum Maximum mm. in. mm. in. mm. in. 3/64 1.17.046 0.58.023.30 ±.05.012 ±.002 1/16 1.60.063 0.79.031.30 ±.05.012 ±.002 3/32 2.36.093 1.17.046.30 ±.05.012 ±.002 1/8 3.17.125 1.57.062.33 ±.05.013 ±.002 3/16 4.74.187 2.36.093.33 ±.05.013 ±.002 1/4 6.35.250 3.17.125.36 ±.05.014 ±.002 3/8 9.52.375 4.74.187.36 ±.05.014 ±.002 1/2 12.70.500 6.35.250.36 ±.05.014 ±.002 3/4 19.05.750 9.52.375.46 ±.08.017 ±.003 1 25.40 1.000 12.70.500.51 ±.08.020 ±.003

Page 6 SPECIFICATION RW-3023 ISSUE 9 TABLE 3 Requirements PROPERTY UNIT REQUIREMENT TEST METHOD PHYSICAL mm (inches) Dimensions In accordance with Table 1 Section 4.3.1 Dimensional Recovery Longitudinal Change Section 4.3.1 V2 - Percent +1, -5 V4 ASTMD 2671 Percent +1, -15 ASTMD 2671 UL 224 Percent +3, -3 UL 224 Eccentricity (Recovered) Percent 30 maximum Tensile Strength MPa (psi) 10.3 (1500) minimum Section 4.3.2 Ultimate Elongation Percent 200 minimum Secant Modulus (expanded) MPa (psi) 172 (2.5 x 10 4 ) maximum Low Temperature Flexibility -- No cracking UL 224 1 hour at -30 C (-22 F) Heat Shock -- No cracking UL 224 4 hours at 250 C (482 F) Heat Aging 7 days at 158 C (316 F) Followed by tests for: -- -- UL 224 Tensile Strength MPa (psi) 70% minimum of unaged specimens Section 4.3.2 UL 224 Ultimate Elongation Percent 100 minimum Flexibility -- No cracking Dielectric Withstand at 2500 V Seconds 60 minimum Dielectric Breakdown Volts 50% minimum of unaged specimen Section 4.3.5 Dielectric Strength kv/mm 19.7 (500) minimum (Volts/mil) Copper Stability 7 days at 158 C (316 F) No brittleness, glazing, cracking or severe discoloration of tubing. No Section 4.3.4 Followed by test for pitting or blackening of copper. Ultimate Elongation Percent 100 minimum Section 4.3.2 Restricted Shrinkage -- Pass UL 224 ELECTRICAL Dielectric Withstand at 2500 V Seconds 60 minimum UL 224 Dielectric Strength kv/mm 19.7 (500) minimum Section 4.3.5 (Volts/mil) Volume Resistivity Ohm-cm 1 x 10 14 minimum

SPECIFICATION RW-3023 ISSUE 9 Page 7 TABLE 3 Requirements (continued) CHEMICAL (continued) Corrosive Effect 7 days at 158 C (316 F) PROPERTY UNIT REQUIREMENT TEST METHOD -- No Corrosion Section 4.3.6 Flammability -- Pass UL 224, VW-1 Water Absorption (Recovered) 24 hrs at 23 C ± 2 C ( 73 F ± 3 F ) Fungus Resistance Followed by tests for: Tensile Strength Ultimate Elongation Dielectric Strength Percent 0.5 maximum MPa (psi) percent Volts per mm (volts per mil) 10.3 (1500) minimum 200 minimum 19,700 (500) minimum ISO 846 Method B Section 4.3.2