Single-Cell Electroporation Using a Multifunctional Pipette

Similar documents
Growth of Micro-Ikebana on a Floating Substrate: A Method to Monitor Local Supersaturation Levels

Construction of a Seebeck Envelope Calorimeter and Reproducibility of Excess Heat

Note that Methylene Blue-stained cultures may require an additional washing step if the second wash is still very blue in appearance.

Improved Monitoring of P. aeruginosa on Agar Plates

NANO SCRATCH TESTING OF THIN FILM ON GLASS SUBSTRATE

Protocol. NEXTERION Slide H. Protein application

Catherine G. Reyes, Anshul Sharma and Jan P.F. Lagerwall. July 18, Complete description of experimental details

Implantable Microelectronic Devices

Enzyme-mediated preparation of hydrogels composed of poly(ethylene glycol) and gelatin as cell culture platforms

Nickel Electroplating

Supporting informations

Soft silicon anodes for lithium ion batteries

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

10 Manor Parkway, Suite C Salem, New Hampshire

1/2W, 0805 Low Resistance Chip Resistor (Lead / Halogen free)

Packaging Commercial CMOS Chips for Lab on a Chip Integration

ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE

Characteristic and efficiency of PEM fuel cell and PEM electrolyser

Protection Effectiveness of Vapor Corrosion Inhibitor VpCI 619 for Corrosion Under Insulation at Elevated Temperatures

Transmission Electron Microscopy (TEM) Prof.Dr.Figen KAYA

Electricity and Chemistry

Electronic Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 2013

Microcontact Printing Procedures for Adhesive and Conductive Epoxies

Mechanical behavior of crystalline materials- Comprehensive Behaviour

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Course schedule. Universität Karlsruhe (TH)

Novel concept of rechargeable battery using iron oxide nanorods. anode and nickel hydroxide cathode in aqueous electrolyte

Electricity. Characteristic and efficiency of PEM fuel cell and PEM electrolyser Stationary currents. What you need:

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

SOLIK Li-hochleitende Keramiken für all-solid-state Batterien

Electrolysis, electrode polarisation, decomposition voltage, galvanic elements, Faraday s law.

Supporting Information

What is Electroplating?

All-solid-state Li battery using a light-weight solid electrolyte

Realization of ITS-90 from K through K: One Company s Approach

Ceramic and glass technology

Diffused Aeration Piping Equipment

Protocol. Nexterion Slide A+ MPX 16. DNA-application

Corning BioCoat Matrigel Matrix 6-well Plates for Embryonic Stem (ES) Cell Culture. Catalog Number Guidelines for Use

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Why Does Rust Occur? 7.1 IN GENERAL

Introduction. 1 Method for making work rolls for cold rolling and characteristics required for rolls

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

All panels can be supplied in a range of styles, to suit the applications pictured below.

HIGH TEMPERATURE FURNACES. High Temperature Chamber Series High Temperature Tube Series High Temperature Elevator Series

Lab #2 Wafer Cleaning (RCA cleaning)

AVX Specialty Catalog

Leveraging the Precision of Electroforming over Alternative Processes When Developing Nano-scale Structures

Cryogenic substrate cooling or substrate heating without vacuum feedthroughs

PRELIMINARY. HTHA (Z1-Foil)

HTHA (Z1-Foil) Vishay Foil Resistors

GeneGel HyRes Starter Kit

Electron Microscopy (EM) Grid

Preparing Cell Cultures of Human Embryonic Kidney

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

PCB Technologies for LED Applications Application note

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Revised 27 Aug rm (Vers. 4.1)

icell DopaNeurons Application Protocol

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Bulk Deformation Processes

Chapter 15 Extrusion and Drawing of Metals

SPIRAL-WOUND PEM FUEL CELLS FOR PORTABLE APPLICATIONS. T.J. Blakley, K.D. Jayne, and M.C. Kimble

PLP 6404 Epidemiology of Plant Diseases Spring 2015 LAB 2 PHASES IN THE DISEASE CYCLE: GREENHOUSE AND LAB EXERCISE

Oligomer-Coated Carbon Nanotube Chemiresistive Sensors for Selective Detection of Nitroaromatic Explosives

Non Destructive Inspection Technology for Thermal Power Plants

EXTRA CREDIT - EXPERIMENT G ELECTROCHEMISTRY ACTIVITY OF METALS

Salinity in Seawater

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

CHAPTER III METHODS AND MATERIALS

Extrusion. Key Issues to Address. Lecture 2. Process. Process Variants. Process Analysis. Problem Solving

Lithium Potassium Manganese Mixed Metal Oxide Material for Rechargeable Electrochemical Cells

Uddeholm Formvar. FORMVAR is a trade mark registered in the European Union

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Preparation for 3D cell culture on Alvetex Scaffold. 1. 3T3 cells were routinely maintained in T-75 flasks.

AM1880 Standard Platinum Resistance Thermometer User s Guide

EFFECT OF THE MICROSTRUCTURE OF Ni/Au METALLIZATION ON BONDABILITY OF FR-4 SUBSTRATE

Supporting Information. Self-Supporting Nanoclay as Internal Scaffold Material for Direct Printing of Soft Hydrogel Composite Structures in Air

SP3S-AQ2-01 AIR QUALITY SENSOR S March, 2004

Electrodes: »3 types. Types: Micro electrode Depth & needle electrodes Surface electrodes

TIG WELDING OPPORTUNITIES OF BIMETALLIC ENDLESS SAW BLADES

AGAROSE GEL ELECTROPHORESIS. Assiut University

Materials and Methods Materials Required for Fixing, Embedding and Sectioning. OCT embedding matrix (Thermo Scientific, LAMB/OCT)

METAL FINISHING. (As per revised VTU syllabus: )

Specimen Preparation Technique for a Microstructure Analysis Using the Focused Ion Beam Process

a) The self-diffusion coefficient of a metal with cubic structure can be expressed as

Evaluation of the Orientation of 90 and 180 Reinforcing Bar Hooks in Wide Members

AISI D2 Cold work tool steel

Chapter 19. Forming and Shaping Plastics and Composite Materials

SIMS Analysis of Hydride in Commercially Pure Titanium

HAND BOOK OF ELECTROPLATING ANODIZING & SURFACE FINISHING TECHNOLOGY

Galvanic Metallisation of CFRP devices

Extended-Frequency SMA Connectors

Guide for Conformal Coated Tantalum Capacitors

Sample Preparation 3D Cell Explorer. Version 1.1 July 2015 Sabine Bautz

LAMINAR FLOW FUEL CELLS & FLUID DYNAMICS IN THE HIGH SCHOOL CLASSROOM

THERMOFIT ADHESIVE S Flex Fluid Resistant, High Temperature, One Part-Flexible Epoxy

Troubleshooting of Electrolytic Color Anodizing of Aluminum

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

Transcription:

Single-Cell Electroporation Using a Multifunctional Pipette Alar Ainla, Shijun Xu, Nicolas Sanchez, Gavin D. M. Jeffries and Aldo Jesorka Electronic Supplementary Information (ESI) Table of contents Table of contents... 1 Supplementary Methods... 1 Method S1. Cell preparation... 1 Method S2. Dye loading of cells... 1 Method S3. Preparation of carbon fiber electrodes... 2 Method S4. Electric field simulation... 2 Method S5. Fabrication of the Pipette with an integrated electrode... 2 Table S1. Simulation settings for the external carbon fiber electrode... 2 Table S2. Simulation settings for the integrated Field s metal electrode... 3 Table S3. Geometries of the macroscopic parts of the electroporation setup... 3 Table S4. Serial resistance components.... 4 Figure S1. A schematic representation of the electrode setup... 5 Figure S2. Fluorescent and brightfield micrographs of pipette electoporated cells... 5 Table S5. Characteristic parameters and operation conditions for the microfluidic superfusion pipette.... 6 Supplementary Methods Method S1. Cell preparation Adherent NG-108-15 cells were cultured in thin glass bottom (#1 coverslip) petri dishes, suitable for confocal imaging, for 2-6 days in Dulbecco s modified eagle medium (DMEM) supplemented with fetal calf serum (10%). Method S2. Dye loading of cells The cells were loaded with the calcium sensitive dye, Calcium-Green -1 AM ester (Life Technologies Inc, Carlsbad, USA). A 200 µm stock solution was first prepared using DMSO, which was then diluted with Ringer s solution (VWR) to obtain a final working concentration of 4 µm. After removing the petri dish from the incubator, the culture medium was removed and the cells were rinsed twice with PBS buffer, followed by the addition of 2ml of the calcium dye loading solution. The cells were exposed to the dye loading solution for 1 h at room temperature, then rinsed twice with phosphate buffered saline (PBS) buffer 1

(Ca 2+ free). This buffer had an ionic strength of 60 mm; containing 5 mm Trizma base, 30 mm K 3 PO 4, 30 mm KH 2 PO 4 and 0.5 mm NaEDTA, NaOH adjusted to ph 7.8, and was also used as the main buffer for all experiments. Method S3. Preparation of carbon fiber electrodes Plastic encapsulated ProCFE carbon fibers, with an OD 5 µm, were obtained from Dagan Corp. and assembled as follows: An OD 1.0 mm borosilicate glass tube was trimmed to 5 cm in length, using a ceramic glass cutter or diamond scribe. A 10 cm long silver wire was inserted such that 1cm protruded from the tube. Conductive silver epoxy (ELFA Electronics, Sweden) was mixed in a 1:1 ratio and a drop of 2-3 mm diameter was applied to the protruding end. The glass rod with the epoxy covered end was quickly inserted into the rear of the plastic covered carbon fiber, such that the epoxy filled the plastic barrel completely. Additional epoxy was applied where necessary, to achieve a complete seal. The carbon fibers were stored vertically, with the tip pointing downwards, for at least 1h before use, to ensure that the silver epoxy had sufficiently hardened. Method S4. Electric field simulation Electric field strengths were evaluated in numeric simulations using COMSOL Multiphysics 4.1 employing the electric currents (ec) model. The electrical conductivity of water was set to an initial value of = 5.5 10 (pure water in COMSOL). Our model is, however, insensitive to the exact values of electrical conductivity, as long as the value is used consistently throughout the calculations. Two simulation series were performed: one for the carbon fiber electrode, and another for the integrated Field s metal electrode, using the parameters outlined in tables S1 and S2, respectively. In both cases the Cell was modeled to be 5 µm high, a diameter of 20 µm, with an insulating membrane and a conducting interior. Method S5. Fabrication of the Pipette with an integrated electrode PDMS multifunctional pipettes were fabricated as described earlier 21. Electrodes were prepared as shown in Figure 1. First, the bottom of the well connecting to the electrode channel was filled with grains of Field s metal (Alloy MCP61, Mindsets Ltd, Waltham Cross, UK). Thereafter, the pipette was heated to ~70-90 C for 1min on a hot plate. Pressure of up to 2.7 bar was then applied, which caused the molten metal to quickly (<5s) fill the channel, forming a droplet at the pipette tip. The pipette was removed from the hot plate, and left to cool to room temperature. Excess metal was removed from the tip using tweezers. The pipette was inspected under a light microscope to check for air entrapped in the metal filling. Defects were corrected by repeating the filling cycle. Gold coating. In order to eliminate electrochemical degradation of the Field s metal, we electrodeposited a gold film onto the exposed electrode surface at the pipette tip. For this purpose the tip was immersed into a common commercial KAu(CN) 2 based gold plating solution A3000 (Aurotech, Sweden) with Na 2 CO 3 added for ph adjustment. A Pt wire was used as a counter electrode and a potential of -1.6V (relative to the Pt wire) was applied for 10 min to the Field s metal electrode for deposition. Interfacing. A custom pipette holder was ordered from Teadusmosaiik OÜ (Tartu, Estonia). This holder was equipped with M4 screw holes at the top surface of the manifold, which allowed access to the pipette wells. The holes are normally hermetically sealed with Teflon tape tightened screws. The electrode-fitted well was interfaced with a spring loaded battery contact (ordered from ELFA, Sweden), which was fitted into a Nylon screw. The spring-loaded contacts ensured good electrical connection without putting strain on the Field s metal plug. Table S1. Simulation settings for the external carbon fiber electrode Parameter Values Outer dimensions of the simulation volume 100 µm x 100 µm Height of the simulation volume 50 µm Radius of the fiber tip 2.5 µm Height of the fiber (center) 2.5 µm Distance between fiber and center of the cell (series) 10, 15, 20, 25, 30, 35, 40 µm Calculated electrical resistance of the simulation volume (R sim ) 16 GΩ 2

Table S2. Simulation settings for the integrated Field s metal electrode Parameter Values Bottom dimensions of the simulation volume 300 µm x 200 µm Height of the simulation volume 150 µm Width of the pipette tip 200 µm Electrode size 20 µm x 20 µm Thickness of the bottom membrane 20 µm (bottom to electrode distance) Pipette height (distance between pipette bottom and surface) 0, 5, 10, 20, 40 µm (series) Pipette angle 30 Pipette position in the middle of sim. volume Distance between pipette and center of the cell (series) 10, 20, 30, 40, 50, 60, 80, 100 µm Calculated electrical resistance of the simulation volume (R sim ) 9.1 GΩ The total resistance of the electroporation setup can be calculated as a sum of resistances of electrodes, the interface between the metal and the liquid, and the liquid bath. In this particular geometry we can divide the resistance of the liquid bath further into serial components. = + + +. describes the resistance of the simulation volume, which is in the immediate vicinity of the electrode, describes a spherical extension of this volume extending to the surface of the bath, describes the resistance of the bath as a thin disk shaped water layer ( h), and finally, describes the resistance around the cylindrical gold counter electrode, which is placed as a loop inside the liquid bath. The geometry of the setup and all resistances are shown in figure S1. The resistances between the spherical surfaces can be calculated from the equation, = 4 1 1 While for cylindrical and disk shaped volumes it is expressed as, = 2 where =1 1.8 10 Ω stands for the resistivity of water. The geometries of the macroscopic parts are given in table S3. Table S3. Geometries of the macroscopic parts of the electroporation setup Parameter Symbol Value Radius of the dish 22 mm Height of water level in the dish h ~4 mm Length of Au wire =2 ~140 mm Diameter of Au wire 0.2 5mm Radius of simulation volume (Carbon fiber 50 µm electrode) Radius of simulation volume (Integrated electrode) 150 µm In case of the integrated electrode, the geometries of the macroscopic parts remain the same, only the simulation volume changes. The resistance of each component can be calculated for both setups (Table S4). 3

Table S4. Serial resistance components. This estimation of resistances justifies the assumption that the entire voltage drop in the bath occurs inside the simulation volume. The error in both case should be < 4 %. Component Expression Value (Carbon fiber) Value (Integrated electrode). -- ~40 Ω -- -- 16 GΩ 9.1 GΩ 2 1 1 h 0.57 GΩ 0.18 GΩ 2h 12 MΩ 12 MΩ h 2 h 0.57 MΩ 0.57 MΩ The actual electric conductivity of the buffer solution can be estimated from the conductivity equation for strong electrolytes (Atkins, Physical Chemistry 6 th ed, 2000). Λ= Where denotes the concentration of a certain ion and this ion s molar conductivity. In case of ECB solution, the most prominent ions are Na + (~140 mm, = 5.01 ) and Cl - (~140 mm, =7.63 ), giving Λ 1.8 S m, which is ~330,000 times larger than for MilliQ (18 MΩ) water, giving a resistance estimate of the liquid bath to be ~50 kω in the case of the carbon fiber system, and ~28 kω in the case of the integrated electrode. These values are still significantly larger than, for example, the electrode resistance, which can be neglected. 4

Figure S1. A schematic representation of the electrode setup Figure S1. A schematic representation of the electrode setup; (A) plan view, (B) side view. The side view shows the series of resistances used in the simulations. The red dotted lines indicate the calculation regions; he central rectangle is was numerically simulated, the circular regions were analytically solved. The dish radius is denoted by r, the liquid level is denoted by h. All other parameter are defined in table S3 and S4. Figure S2. Fluorescent and brightfield micrographs of pipette electoporated cells Figure S2. Fluorescent and brightfield micrographs at selected time points, for single cell electoporation using the pipetee encorporated electrode, for the graph in figure 3B. (A) Shows the calcium transport through imaging of the calcium green reporter dye. (B) displays the state of the cell prior and post electroporation as well as during calcium exposure. The lack of typan staining at the end of the experiment was a strong indication of membrane integrity at the end of the experiment. 5

Table S5. Characteristic parameters and operation conditions for the microfluidic superfusion pipette. Description Symbol Value Unit Channel width w 20 µm Channel height h 20 µm Supply channel length L s 30 mm Outlet channel length L o 10 mm Electrode channel length L e 40 mm Hydraulic conductance Supply channel G s 19 /( ) Outlet channel G 0 56 /( ) Electrode resistance R e 40 Ω (calculated) Operating settings Injection on pressure P on 0.15 Bar Injection off pressure P off 0 Bar Vacuum V -0.6 Bar Inflow-Outflow ratio I/O 4 Outflow Q out 1.65 nl/s Inflow Q in 6.6 nl/s Approx. liquid exchange delay τ 2.4 s 6