Arsenic Treatment - Lessons From the Past Few Years

Similar documents
ARSENIC IN DRINKING WATER

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

Existing Arsenic Treatment Systems in California: Performance and Cost Comparisons

The city of Clearwater owns and operates

GAC for PFC Removal. Eric Forrester. Application Engineer P: E: Calgon Carbon Corporation 2017 Slide 1

A3: Contaminant Reduction, Life Cycle Impacts, and Life Cycle Costs of Ion Exchange Treatment and Regeneration

Pilot Study Report. Z-92 Uranium Treatment Process

Next Hurdle: 1,2,3-Trichloropropane. Kevin Berryhill

WRF Webcast Hexavalent Chromium Treatment with Strong Base Anion Exchange (#4488)

Treatment techniques for control of disinfection byproduct (DBP) precursors.

The 2013 University of Oklahoma International WaTER Conference

Iron/Manganese Package Plant Pre-Engineered Ground Water Treatment. Village of Bolivar, NY

Selenium Reduction. Caroline Dale

Arsenic Removal from OU Water. Sami Karam Randy Goll Ross Chaffin Roman Voronov

Engineered Media for Municipal and Industrial Applications

Renovation of the Filters at the Soldier Canyon Filter Plant in Fort Collins, Colorado

Water Treatment Plant Design at the Idaho Cobalt Project

GAC Filters for More Than Just TOC Removal

ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium

Side by Side Piloting of Process Alternatives Yields Direct Performance Comparison

Removal of Arsenic from OU Water Paul Gerber, Collin Martin, John Siska

Selenium Removal. Caroline Dale

Feasibility of Water Treatment Technologies for Arsenic and Fluoride Removal

Drinking Water Treatment Optimization Tools

Optimizing Filter Conditions for Improved Manganese Control During Conversion To Biofiltration [Project #4448]

Supporting Information. Selenium Removal from Sulfate-Containing Ground Water Using. Granular Layered Double Hydroxide Materials

ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER

Progress Report. State Water Resources Institute Program (SWRIP) March 2006 to February 2007

MONTHLY OPERATION REPORT (MOR)--ALL WATER SYSTEMS

Project 1 Treatment Cost. Project 1 Treatment Cost. Project 1 Treatment Cost. Project 1 Treatment Cost. Project 1 Treatment Cost

ACHIEVING STAGE 2 DBPR COMPLIANCE THROUGH SYSTEM OPTIMIZATION AND EFFICIENT USE OF POST-FILTRATION GAC: A 5 YEAR CASE STUDY

Using a Pilot Plant to demonstrate how raw water alkalinity can influence the treatment of drinking water

Matt Leach, P.E. CH2M. Mark Eppich, P.E. City of Columbus Division of Water. S. Dean Ramsey, P.E. CH2M

Evaluation of Second-Stage Contactor Media for Manganese Removal

FGD Wastewater Treatment Evaluation

Treatment Processes for Potable Water

ONLINE MONITORING PRACTICES FOR MANGANESE CONTROL IN DRINKING WATER TREATMENT

MEMBRANES FOR WTPS JUSTIN RAK-BANVILLE, M.SC., P.CHEM., EP WATER AND WASTEWATER INFRASTRUCTURE WSP CANADA INC

Assessment of Ion Exchange, Adsorptive Media, and RCF for Cr(VI) Removal

2016 Report on Water Quality Relative to Public Health Goals

Committed to protecting and preserving our environment. Entipur Monitor. Whole House Water Treatment.

Figures...vii Tables... ix Acknowledgments... xi Foreword... xiii Preface...xv

Performance Data Sheet

Borough of Hopewell, New Jersey

Treatment Solutions For Water Systems. Arsenic Iron Manganese Fluoride Hydrogen Sulfide Uranium Nitrates Radium Turbidity

Ocean Outfall Rule Compliance. Piloting Alternative Technologies for Recharge of the Floridan Aquifer. July 8, PD-Sw202w

ATTACHMENT A TO THE AGREEMENT FOR ENGINEERING SERVICES. Project: Chloramine Replacement Alternative Evaluation

Integrating Ozone and Ion Exchange into a 40 Year Old Lime Softening Plant

NEWMOA PFAS Technical Workshop Activated Carbon

Removal of Manganese by Microfiltration in a Water Treatment Plant*

North American Biofiltration Knowledge Base. Appendices A and B. Project #4459

Long Point Water Treatment Plant Process Evaluation and Design Upgrades for Performance Enhancement; Dover, DE

Lead & Copper Control with Phosphates Darin Skutt Technical Service Manager Carus Corporation

SIMPLE FILTER CAPPING APPROACHES FOR ENAHANCED BIOLOGICAL FILTRATION PERFORMANCE. Andrew WT Wong, EIT, University of Waterloo*

SESSION 7. High Turbidity Event Panel Discussion Contingency Plans and Lessons Learned

TECHNICAL MEMORANDUM 1 Desktop Evaluation of Alternatives GenX and Other PFAS Treatment Options Study

Ocean Outfall Rule Compliance. Piloting Alternative Technologies for Recharge of the Floridan Aquifer. June 20, PD-Sw202w

BoMet Bo B ro r n se s lecti t ve a d a sorb r e b nt re r s e in f r f o r m Hunga g r a y

NON-ECONOMIC ADVANTAGES OF UV-OXIDATION FOR 1,4-DIOXANE TREATMENT. New York s Water Event April 25, 2017

Optimizing the Ballasted Sedimentation Process at the Anacortes Water Treatment Plant Jeff Marrs Plant Manager Greg Pierson - HDR

Removal of Hydrogen Sulfide from Groundwater by Granular Activated Carbon

ARSENIC REMOVAL FROM GROUNDWATER BY FE-MN OXIDATION AND MICROFILTRATION. Sevil Caniyilmaz. B.S., Middle East Technical University, 2003

Chemical quality of household water in Bangladesh

Use of Spiral Wound UF in RO Pretreatment

Removing Heavy Metals from Wastewater

Development of Fe-GAC Adsorbent for Arsenic Removal

Granular Activated Carbon System

IWA Nutrient Removal and Recovery 2015: moving innovation into practice MAY 18-21, 2015 GDAŃSK, POLAND

Startup and Performance of the World s first Large Scale Primary Dissolved Air Floatation Clarifier ABSTRACT KEYWORDS INTRODUCTION

REAL WORLD APPLICATIONS OF USING DYNAMIC SIMULATION SOFTWARE TO OPTIMIZE WATER TREATMENT PLANT PROCESS OPERATIONS

Reverse-osmosis membranes were

Performance of GAC Filter-Adsorbers for Herbicide and DBP Control at Higginsville,, MO

Reducing THM via Aeration: A Case Study August 28, 2014

West Orange County System

Sulaibiya world s largest membrane water reuse project

Agenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References

EVALUATING NANOFILTRATION, REVERSE OSMOSIS, AND ION EXCHANGE TO MEET CONSUMPTIVE USE CONSTRAINTS AND FINISHED WATER QUALITY GOALS FOR BROWARD COUNTY

Innovative Approach to Expanding the Olentangy WTP

SHORT BED ION EXCHANGE TECHNOLOGY PRODUCES ULTRAPURE WATER WITHOUT USING A MIXED BED

Lignite versus. bituminous GAC for biofiltration a case study

Case Study Using Fenton s Reagent Under a Performance- Based Remediation Contract

Impact of Chlorine Dioxide on TTHMs Reduction in Drinking Water By Douglas D. Rittmann, Ph.D., P.E. Water/Wastewater Consultant

Water Treatment Plant Startup Issues and Considerations

Watch Water. ANSI/NSF 61 Certified From. February 2014

Recovery & Concentrate Management

A wastewater treatment facility s experience with a fresh water sponge infestation and methods used in control and eradication

Online THM Analyzer Integral to City of Benicia s Stage 2 DBPR Compliance Strategy

Walnut Shell Filter Reuse Potential

Carbon Canyon Water Recycling Facility Title 22 Engineering Report

Pilot Testing Reveals Alternative Methods to Meet Wisconsin s Low Level Phosphorus Limits

Report AQUA METROLOGY SYSTEMS. SafeGuard H2O Pilot Report. Online Cr(VI) Remediation System

The Town of Davie (town) operates a

Online Methodology for Determining THM Formation Potential & Predicted Network TTHM Levels

THE SYNERGISTIC EFFECTS OF DESIGNING OZONE WITH A BIOLOGICALLY ACTIVE FILTER

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER

Localized Treatment for DBP s using Spray Aeration and Online Monitoring

Membrane Systems. Featuring Aqua MultiBore Membranes

Advanced Treatment of Flowback Water Using Magnetic Ballast Clarification and Vortex Generating Membrane Systems for Discharge

In-Reservoir TTHM Surface Aeration: A year of results, experience and lessons learned

Transcription:

Arsenic Treatment - Lessons From the Past Few Years Sam Perry Water Treatment Engineer

Mission To protect the health of the people of Washington State by ensuring safe and reliable drinking water. 2

Arsenic and Heart Disease 2.00 Heart Disease - Hazards Ratio 1.80 1.60 1.40 1.20 1.00 0.80 ND-12 12.1-62 62-148 148-864 Arsenic (μg/l) Ref. British Medical Journal 2/2011 3

Other Recent Health Findings Cancer Current 1/10,000 health risk is at 2 ppb Toxicological Reviews EPA IRIS (2010) - Draft More potent carcinogen than previously indicated National Research Council (2013) Review multiple health endpoints skin, diabetes, neurodevelopmental Sensitive life stages (early childhood) Could lead to lower MCL?? (maybe) 4

Arsenic Treatment Experiences (USEPA) EPA Treatment Demonstration Studies 50 Water Systems 31 Adsorbent (62%) 2 Ion Exchange (4%) 15 Oxid./Coag./Filtration (30%) 2 Reverse Osmosis (4%) Treatment performance varied Sauk Center, MN 33% > As MCL Pentwater, MI 45% > As MCL 5

Arsenic Treatment Experiences (WA) Overall Perspective (as of 12/2013) 116 Affected Water Systems 64 Treating (55%) - Includes blending 36 Non-treatment alternative (31%) 16 Installing treatment/undecided (14%) Physical Treatment (SDWA Regulated) Performance has varied 8 of 52 (15%) - Most recent As sample greater than MCL 6

Arsenic Treatment Optimization Program Why/What? Not all treatment is successful Encompass concepts from Area Wide Optimization Program (AWOP) Seek first to understand Invest in people (operators/technical capacity) Empower small operational and treatment adjustments Provide a greater level of public health protection 7

8

Arsenic Treatment in WA Number of Systems by Technology Type Oxid/Filtration 15 Adsorbent 15 Blending 12 Coag/Filtration 25 Aeration/Settling 1 Reverse Osmosis 1 9

Before Reevaluating Design It is important to: Be aware of the range of options. Understand your raw water quality. Test your assumptions. Realize that the situation may be special. Avoid shortcuts. 10

Design & Operations - Some Considerations Adsorbents Raw water quality Oxidant and contact time Type of adsorbent ph adjustment Empty bed contact time (EBCT) Backwash Coag/Filt (Ox/Filt) Raw water quality Filter media - type, depth Oxidant dose and contact time Coagulant dose and contact time Filter loading rate, run length, backwash 11

Test Your Assumptions Arsenic treatment can be challenging Each application is unique Full-scale failure is not uncommon Pilot Testing Tools Jar testing (Ox/Coag/Filt) Small-scale pilot tests (Ox/Coag/Filt; IX) Rapid small scale column tests (Adsorbents) 12

Rapid Small Scale Column Tests (RSSCTs) Used to estimate breakthrough curves for adsorbents Rapid (1-3 weeks) Small Bench scale (5-10 gal/day) Multiple adsorbents can be compared 13

RSSCT Example Valley Vista, AZ Parameters AA-FS50 Full-scale RSSCT Media Radius (mm) 0.425 0.064 Column diameter (cm) 91.4 1.1 Column depth (cm) 183 15.9 EBCT (min) 4.5 0.68 Loading rate (gpm/ft 2 ) 5.5 5.0 Flowrate (ml/min) 170,100 22.3 Mass of media (g) -- 23 Duration 8 months 3 weeks (Ref. Dr. Paul Westerhoff, Ariz. State Univ.) 14

Effluent As (ppb) RSSCT Validation (Pilot vs. RSSCT for As Breakthrough) 20 GFH PD-RSSCT 15 Pilot Test 10 5 0 0 10 20 30 40 50 60 70 80 90 100 Bed Volumes treated (Thousands) Effluent As(ppb) 20 GFH 15 10 5 0 PD-RSSCT Pilot 0 10000 20000 30000 40000 50000 60000 70000 Bed Volumes treated Effluent As (ppb) 40 35 30 25 20 15 10 5 0 E33 0 5000 10000 15000 20000 Bed Volumes treated RSSCT Pilot Effluent Arsenic (ppb) 12 10 8 6 Arizona Groundwater Influent Arsenic = 12 ppb ArsenX 4 RSSCT: Spherical media (100x140 mesh) 2 Pilot Test: spherical full-size media 0-20,000 40,000 60,000 80,000 100,000 120,000 Bed Volumes Treated (Ref. Dr. Paul Westerhoff, Ariz. State Univ.) 15

RSSCTs The 411 RSSCT service providers: CH2M Hill Laboratory Corvallis, OR Tim Maloney; 541-768-3124 Tim.maloney@ch2m.com University of South Florida Dr. Vinay Gupta; 813-974-0851 vkgupta@eng.usf.edu HDR Denver, CO /CU Boulder Dr. Philip Brandhuber; 303-764-1527 Philip.Brandhuber@hdrinc.com Cost: Budgetary cost $10K-$20K Ship 55 gal drums ($150 each; 1-2/column)

Tweaking the Process - Adsorption Re(evaluate) water quality Add/Increase preoxidation time [Convert As(III) to As(V)] Free chlorine 1 mg/l, 20 to 60 seconds Other oxidants possible (KMnO 4, etc.) Increase empty bed contact time Longer bed life at longer EBCT Lower ph Test other adsorbents - use RSSCTs Switch to coagulation/filtration

Tweaking the Process Coagulation/Filtration (Re)evaluate water quality Increase preoxidation time [Convert As(III) to As(V)] Free chlorine 1 mg/l, 20 to 60 seconds Add more coagulant Increase coagulant contact time Lower filtration rate Lower ph

Arsenic Treatment - Field Data Sheet 19

Process Adjustment Increase Oxidation Time Moving the Chlorine injection Location and adding Contact time optimized removal

Effect of Increased Oxidation Time Preoxidation Before Chlorine added with Ferric After Pre-Chlorination 30 Seconds Raw Water Arsenic, ug/l 158 158 Finished Water Arsenic, ug/l 9.02 1.24 TMWA, Sparks, NV Courtesy CH2M HILL, 2010 Percent Removal 94.3% 99.2% Number of Samples 23 19 Raw Water ph 7.7 7.7 Ferric Chloride Dose, 26 21 mg/l Treated Water ph 6.7 6.72 Filter Loading Rate, 6.0 6.0 gpm/sq ft Media Type Manganese Dioxide Manganese Dioxide Media Depth, In 42" 42" 21

Case Study Lummi Island, WA 22

Hilltop Water Owners Assoc. 62 Connections Res. Pop. 72; Total Pop. 135 Raw Water Arsenic 22 to 25 ppb Brief History 2004 to 2008 - Try adsorption, other treatment; Make other improvements 12/2008 - Full Scale Pilot of Ox/Coag/Filt 11/2011 - Sanitary Survey 23

Hilltop Effect of More Iron Hilltop Arsenic 0.030 0.025 Treatment Apprvd. 12/2008 Loss of Iron Feed (?) Process Modified 2/1/12 0.020 Arsenic Level mg/l 0.015 0.010 0.005 12/11-1/12 Analyze, Baseline Sample 0.000 Sample Collection Date 24

Hilltop - Lessons Multiple possible issues A curious operator can really help the plant optimize Ultimately, Hilltop required only minor operational adjustment Success involved cooperation PWS Owner, Operator, Department of Health Staff 25

Case Study Electric City, WA 26

Electric City Turbidity and Backwash (Normal) Turbidity (Start-up spike) Backwash Flow Backwash Recycle Flow 27

Electric City Turbidity and Backwash (Filter Overload) Turbidity (Start-up spike) Backwash Flow Backwash Recycle Flow 28

Monitoring the Process is Key Any treatment process, if not adequately designed, operated and maintained, will fail. Arsenic In WA, one sample/month required Iron Good surrogate for arsenic removal (ox/coag/filt) Turbidimeters Provide continuous data (very valuable if recycle backwash) 29

Summary It is possible to meet optimization goals Consider plan-do-check-act approach 1. Collect WQ data ph, As, Fe, Mn, Si, P, V, TOC 2. Pilot test RSSCTs; C/F- Small scale pilot 3. Monitor the process Turbidity, Fe, As 4. Minor tweaks - Can improve results 30

Acknowledgements Stephen Baker, Russell Mau, Erika Lindsey, Steve Hulsman - WSDOH Jeremy Robinson, Richard Frye - Hilltop Water Owners Assoc. Tom Sorg, Darren Lytle EPA ORD Lee Odell CH2M Hill Paul Westerhoff Arizona State Univ. 31

Questions / Comments Sam Perry sam.perry@doh.wa.gov (253) 395-6755 32