SECTION 07530CP EPDM MEMBRANE ROOFING

Similar documents
SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS MEMBRANE ROOFING

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION TURBINE VENTILATORS

ITEM 458 WATERPROOFING FOR STRUCTURES

SECTION EXPANSION CONTROL

LAKEWOOD HIGH SCHOOL RECOAT/REROOF PROJECT 100% OWNER REVIEW

SECTION ALPHAGUARD RESTORATION 20 YEAR WARRANTY SYSTEM. f. Conditions and Division 01 Specification Sections, apply to this Section.

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

1 Firestone EPDM Roofing Systems

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

FIRESTONE ULTRAPLY TPO SA APPLICATION GUIDE

RUBBERGARD EPDM SA APPLICATION GUIDE

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

FLUID APPLIED WATERPROOFING

Repair Maintenance Hangar Phase II August 2010

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

ARCHITECTURAL GUIDE SPECIFICATION REROOFING OVER EXISTING BUR C-EPDM SYSTEM 2001 FOR STEEL AND WOOD DECKS

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SECTION IMPACT RESISTANT WALL PROTECTION

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

GenFlex EZ TPO Peel & Stick SA (HW) APPLICATION GUIDE

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

1.1 SECTION INCLUDES Verify Scope, including identification of plies and type of coating.

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

SECTION PVC SINGLE PLY ROOFING

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

A. Source Limitations: Obtain each type of building insulation through one source.


CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

TILE TILE

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

SECTION HVAC GRAVITY VENTILATORS

2016 Capital Improvement Project REHABILITATION OF METAL ROOFING SECTION REHABILITATION OF METAL ROOFING PART 1 - GENERAL

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

SECTION RESILIENT SHEET FLOORING

SCOPE OF WORK PROJECT IDENTIFICATION

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

A. Access doors and frames are part of an access door and frame allowance.

ARCHITECTURAL SPECIFICATIONS LOOSE LAID & BALLAST SYSTEM

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

SECTION SELF-ADHERING SHEET WATERPROOFING

SECTION HVAC INSULATION

SECTION METAL ROOF PANELS

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS

Specifications for FL-100 Soffit Panel

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Firestone RubberGard The EPDM reference

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

PRE-ENGINEERED METAL BUILDING SYSTEM

Firestone Polyiso Boards

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

DIVISION 07 - THERMAL AND MOISTURE PROTECTION Preparation for Re-Roofing Built-Up Asphalt Roofing, Cold-Applied

Metal Roof Panels

Union County Vocational - Technical Schools Scotch Plains, New Jersey

UL Listing: EPDM Roofing Systems

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Page 1 of 5

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

TTR SYSTEMS ROOF SPECIFICATION

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

COMMERCIAL ROOFING SYSTEMS

SECTION CONCRETE PAVING SLABS SET IN MORTAR

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

SECTION PREPARATION FOR RE-ROOFING

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

Corium Brick Rainscreen System Specifications

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION ACOUSTICAL PANEL CEILINGS

SECTION PIPING INSULATION

TEKTON Flashings and TEKTON Construction Tape

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

Transcription:

PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL DESIGN REQUIRENTS A. Use a fully adhered membrane no ballasted or mechanically fastened systems. Do not use EPDM around mechanical equipment where oils or grease may contaminate the membrane. Use heat-welded PVC membrane (Sarnafil) for these locations. B. Show all mechanical equipment supports and all penetrations on the roof plan and provide design details to address each condition. Use round pipes for all roof penetrations, so that the membrane can be secured with a hose clamp. Do not use wide flange-type profiles to penetrate the membrane. C. Perform wind load and uplift calculations per ASCE/ANSI 7, Minimum Design Loads for Buildings and Other Structures, current edition and verify that the roofing system chosen is capable of sustaining the calculated uplift loads. D. For new construction provide sloped roof deck rather than tapered insulation for general roof drainage. Use tapered insulation or wood blocking at flashing details to promote local drainage. E. Perform a roof drain calculation and size drains accordingly. Elevate the perimeter of the roof to promote drainage to interior drains. Make provisions for overflow drainage in the event of drain blockage. 1.3 PERFORMANCE REQUIREMENTS A. Install sheet membrane roofing and base flashing that are watertight; will not permit the passage of liquid water; and will withstand wind loads, thermally induced movement, and exposure to weather without failure. B. Material Compatibility: Provide roofing materials that are compatible with one another under conditions of service and application required, as demonstrated by roofing system manufacturer based on testing and field experience.

C. FMG Listing: Provide roofing membrane, base flashings, and component materials that comply with requirements in FMG 4450 and FMG 4470 as part of a membrane roofing system and that are listed in FMG's "Approval Guide" for Class 1 or noncombustible construction, as applicable. Identify materials with FMG markings. 1. Fire/Windstorm Classification: Class 1A-90. 1.4 WARRANTY A. Special Warranty: Manufacturer's standard form, without monetary limitation, in which manufacturer agrees to repair or replace components of membrane roofing system that fail in materials or workmanship within specified warranty period. Failure includes roof leaks. 1. Special warranty includes roofing membrane, base flashings, roofing accessories, roof insulation, fasteners, cover boards, roof pavers, walkway products and other components of membrane roofing system. 2. Warranty Period: 15 years from date of Substantial Completion. Provide copy of warranty framed and mounted to each roof hatch, door, other means of roof access. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Provide products by one of the following. Obtain all components for roofing system from same manufacturer or as approved by the manufacturer. 1. Carlisle Syntec Systems; Carlisle Corp. 2. Firestone Building Products Co. 2.2 EPDM SHEET A. Membrane: ASTM D 4637, Type I, nonreinforced uniform, flexible sheet made from EPDM, and as follows: 1. Thickness: 60 mils (1.5 mm), nominal. 2. Exposed Face Color: Black. 2.3 AUXILIARY MATERIALS F. Auxiliary materials recommended by roofing system manufacturer for intended use and compatible with membrane roofing. Liquid-type auxiliary materials shall meet VOC limits of authorities having jurisdiction.

G. Sheet Flashing: 60-mil (1.5-mm) thick EPDM, partially cured or cured, according to application. H. Bonding Adhesive: Manufacturer's standard bonding adhesive.seaming Material: Manufacturer's standard synthetic-rubber polymer primer and 3-inch (75-mm) wide minimum, butyl splice tape with release film. I. Lap Sealant: Manufacturer's standard single-component sealant, color to match roofing membrane. J. Water Cutoff Mastic: Manufacturer's standard butyl mastic sealant. K. Metal Termination Bars: Manufacturer's standard predrilled stainless-steel or aluminum bars, approximately 1 by 1/8 inch (25 by 3 mm) thick; with anchors. L. Fasteners: Factory-coated steel fasteners and metal or plastic plates meeting corrosionresistance provisions in FMG 4470, designed for fastening membrane to substrate, and acceptable to membrane roofing system manufacturer. M. Miscellaneous Accessories: Provide preformed cone and vent sheet flashings, preformed inside and outside corner sheet flashings, T-joint covers, in-seam sealants, cover strips, and other accessories. N. Flexible Walkways: Factory-formed, nonporous, heavy-duty, solid-rubber, slipresisting, surface-textured walkway pads, approximately 3/16 inch (5 mm) thick, and acceptable to membrane roofing system manufacturer. 2.4 ROOF INSULATION A. Provide preformed roof insulation boards that comply with requirements and referenced standards, selected from manufacturer's standard sizes and of thicknesses indicated. B. Polyisocyanurate Board Insulation: ASTM C 1289, Type II, felt or glass-fiber mat facer on both major surfaces. C. Tapered Insulation: Provide factory-tapered insulation boards fabricated to slope of 1/4 inch per 12 inches (1:48), unless otherwise indicated. D. Provide preformed saddles, crickets, tapered edge strips, and other insulation shapes where indicated for sloping to drain. Fabricate to slopes indicated. 2.5 INSULATION ACCESSORIES A. Furnish roof insulation accessories recommended by insulation manufacturer for intended use and compatible with membrane roofing.

B. Fasteners: Factory-coated steel fasteners and metal or plastic plates meeting corrosionresistance provisions in FMG 4470, designed for fastening roof insulation to substrate, and acceptable to roofing system manufacturer. C. Cover Board: ASTM C 1177/C 1177M, glass-mat, water-resistant gypsum substrate, 1/2 inch (13 mm) thick. 1. Product: Subject to compliance with requirements, provided "Dens-Deck" manufactured by Georgia-Pacific Corporation. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with the following requirements and other conditions affecting performance of roofing system: i. Verify that roof openings and penetrations are in place and set and braced and that roof drains are securely clamped in place. ii. Verify that wood blocking, curbs, and nailers are securely anchored to roof deck at penetrations and terminations and that nailers match thicknesses of insulation. iii. Verify that minimum concrete drying period recommended by roofing system manufacturer has passed. iv. Verify that concrete substrate is visibly dry and free of moisture. Test for capillary moisture by plastic sheet method according to ASTM D 4263. v. Verify that concrete curing compounds that will impair adhesion of roofing components to roof deck have been removed. vi. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Clean substrate of dust, debris, moisture, and other substances detrimental to roofing installation according to roofing system manufacturer's written instructions. Remove sharp projections. B. Prevent materials from entering and clogging roof drains and conductors and from spilling or migrating onto surfaces of other construction. Remove roof-drain plugs when no work is taking place or when rain is forecast. C. Complete terminations and base flashings and provide temporary seals to prevent water from entering completed sections of roofing system at the end of the workday or when rain is forecast. Remove and discard temporary seals before beginning work on adjoining roofing.

3.3 INSULATION INSTALLATION A. Coordinate installing membrane roofing system components so insulation is not exposed to precipitation or left exposed at the end of the workday. B. Comply with membrane roofing system manufacturer's written instructions for installing roof insulation. C. Install tapered insulation under area of roofing to conform to slopes indicated. D. Install one or more layers of insulation under area of roofing to achieve required thickness. Where overall insulation thickness is 2 inches (50 mm) or greater, install 2 or more layers with joints of each succeeding layer staggered from joints of previous layer a minimum of 6 inches (150 mm) in each direction. E. Trim surface of insulation where necessary at roof drains so completed surface is flush and does not restrict flow of water. F. Install insulation with long joints of insulation in a continuous straight line with end joints staggered between rows, abutting edges and ends between boards. Fill gaps exceeding 1/4 inch (6 mm) with insulation. Cut and fit insulation within 1/4 inch (6 mm) of nailers, projections, and penetrations. G. Adhered Insulation: Install each layer of insulation and adhere to substrate as follows: Set each layer of insulation in a cold fluid-applied adhesive. H. Install cover boards over insulation with long joints in continuous straight lines with end joints staggered between rows. Loosely butt cover boards together and fasten to roof deck. Set cover boards in a cold fluid-applied adhesive. 3.4 ADHERED ROOFING MEMBRANE INSTALLATION A. Install roofing membrane over area to receive roofing according to membrane roofing system manufacturer's written instructions. Unroll roofing membrane and allow to relax before installing. B. Start installation of roofing membrane in presence of membrane roofing system manufacturer's technical personnel. C. Accurately align roofing membrane and maintain uniform side and end laps of minimum dimensions required by manufacturer. Stagger end laps. D. Bonding Adhesive: Apply bonding adhesive to substrate and underside of roofing membrane at rate required by manufacturer and allow to partially dry before installing roofing membrane. Do not apply bonding adhesive to splice area of roofing membrane.

E. Mechanically or adhesively fasten roofing membrane securely at terminations, penetrations, and perimeter of roofing. F. Apply roofing membrane with side laps shingled with slope of roof deck where possible. G. Tape Seam Installation: Clean and prime both faces of splice areas, apply splice tape, and firmly roll side and end laps of overlapping roofing membranes according to manufacturer's written instructions to ensure a watertight seam installation. Apply lap sealant and seal exposed edges of roofing membrane terminations. H. Repair tears, voids, and lapped seams in roofing that does not meet requirements. I. Spread sealant or mastic bed over deck drain flange at deck drains and securely seal roofing membrane in place with clamping ring 3.5 BASE FLASHING INSTALLATION A. Install sheet flashings and preformed flashing accessories and adhere to substrates according to membrane roofing system manufacturer's written instructions. B. Apply bonding adhesive to substrate and underside of sheet flashing at required rate and allow to partially dry. Do not apply bonding adhesive to seam area of flashing C. Apply lap sealant and seal exposed edges of sheet flashing terminations. Terminate and seal top of sheet flashings and mechanically anchor to substrate through termination bars. 3.6 WALKWAY INSTALLATION A. Flexible Walkways: Install walkway products in locations indicated. Adhere walkway products to substrate with compatible adhesive according to roofing system manufacturer's written instructions. 3.7 FIELD QUALITY CONTROL A. Testing Agency: Owner will engage a qualified independent testing and inspecting agency to perform roof tests and inspections and to prepare test reports. B. Final Roof Inspection: Arrange for roofing system manufacturer's technical personnel to inspect roofing installation on completion and submit report to Architect. Notify Architect or Owner 48 hours in advance of date and time of inspection. C. Repair or remove and replace components of membrane roofing system where test results or inspections indicate that they do not comply with specified requirements. Additional testing and inspecting, at Contractor's expense, will be performed to determine compliance of replaced or additional work with specified requirements.

3.8 PROTECTING AND CLEANING A. Protect membrane roofing system from damage and wear during remainder of construction period. When remaining construction will not affect or endanger roofing, inspect roofing for deterioration and damage, describing its nature and extent in a written report, with copies to Architect and Owner. B. Correct deficiencies in or remove membrane roofing system that does not comply with requirements, repair substrates and repair or reinstall membrane roofing system to a condition free of damage and deterioration at time of Substantial Completion and according to warranty requirements. END OF SECTION