Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

Similar documents
Azure Biosystems Western Blotting Workflow

Innovations To Meet Your Needs

Multiplex Fluorescent Western Blot Starter Kit for the Bio- Rad ChemiDoc MP

Flow Cytometry - The Essentials

Chemiluminescence Detection. Using UVP s ChemiDoc-It System

CF Dyes Next Generation Fluorescent Dyes Secondary antibody

Western Blotting Detection Reagents

Speed Past the Twists and Turns in Protein Research

Instant-Bands Protein Sample Loading Buffer for SDS-PAGE. User s Manual. View Protein Bands in an SDS Gel. Instantly. EZBiolab.

Comparing the Agilent 2100 Bioanalyzer Performance to Traditional DNA Analysis Techniques

PERFORMANCE MADE EASY REAL-TIME PCR

GE Healthcare Life Sciences. Laser. epi. trans CCD. epi. Imaging. Principles and Methods

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Optiblot ECL Ultra Detect Kit (1.2pg 2ng)

Imaging Nucleic Acid Gels on the Odyssey Fc Imager

Blotting and Immunodetection. Multiplex Fluorescent Blot Detection: A Troubleshooting Guide

Experimental Protocol for Multiplex Fluorescent Blotting Using the ChemiDoc MP Imaging System

Dolphin-Chemi Plus. Aim: To visualise and evaluate the performance of chemiluminescent immunoblots using Wealtec s Dolphin-Chemi plus image system

Notes to accompany the slidecast on theory of SDS PAGE and Western blotting

Radiance. Long Protocol for Catalog Numbers. Chemiluminescent substrate for quantitative chemiluminescent Westerns

In-Gel Western Detection Using Near-Infrared Fluorescence

BCH 462. Western Blot

d. Bands hidden by overexposure with chemiluminescence become clear when imaged with Odyssey.

Using ULS24 CMOS Bio-imager as a Readout Sensor for Chemiluminescence Immunoassay and DNA Hybridization Assay

Lecture 13: Analysis of 2D gels

Good Westerns Gone Bad:

EZ-Vision DNA Dye as Loading Buffer

ChemiDoc Touch Imaging System

TECHNICAL BULLETIN. in vitro Translation Labeling System. FluoroTect Green Lys. Instruc ons for Use of Product L5001. Revised 11/13 TB285

Proteomics And Cancer Biomarker Discovery. Dr. Zahid Khan Institute of chemical Sciences (ICS) University of Peshawar. Overview. Cancer.

Product Information. Before you begin. Component A 1 vial of 30 ul vial of 300 ul each Glycerol. Tris

Amersham Western blotting

Segments of the obstructed intestinal loops were fixed in 4% paraformaldehyde

This Document Contains:

A legacy of innovation and discovery

GEL IMAGING. The detection and quantitation of specific subsets of posttranslationally

Working Reagent Preparation 1:1,000 dilution in standard Alcoholic Ortho- Phosphoric acid staining solution

FLUORESCENT PEPTIDES. Outstanding Performance and Wide Application Range

Amersham * ECL * Gel horizontal electrophoresis system

In-Cell Western Kits I and II

Optiblot. Western Blot Reagents and Troubleshooting Tips. Discover more at abcam.com/optiblot

Maximize Your Western Blotting Results. Superior products for every step of the Western workflow

Touchscreen (standalone capabilities, PIN-protected user accounts, and dye calibration/rnasep functionality)

Technical Note. Housekeeping Protein Validation Protocol

Protein Electrophoresis EZ-Run Protein Gel Solution EZ-Run Protein Standards EZ-Run Gel Staining Solution Traditional SDS-PAGE Reagents

ab Optiblot Fluorescent Western Blot Kit

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

LabChip 90 System with DataViewer Software

MitoBiogenesis In-Cell ELISA Kit (Colorimetric)

hfab Rhodamine Housekeeping Antibodies

Imaging and Electrophoresis. Gel Doc EZ Imager. Accelerate your research. Push-button imaging in just 10 seconds.

For identifying inhibitors and activators of mitochondrial biogenesis in adherent cultured cells.

PowerPlex 4C Matrix Standard

Confocal Microscopy Analyzes Cells

Molecular characterization, detection & quantitation of biological products Purin Charoensuksai, PhD

EdU Flow Cytometry Kit. User Manual

Comparison of Deep Purple Total Protein Stain and Sypro Ruby in 1-D and 2-D gel electrophoresis

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Comparison of LANCE Ultra TR-FRET to PerkinElmer s Classical LANCE TR-FRET Platform for Kinase Applications

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

and Criterion TGX Stain-Free Precast Gels

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

B-BOX Blue Light LED epi-illuminator. Catalogue No.: VE0100. Operator s Manual Ver

CRISPR/Cas9 Gene Editing

PARP-1 (cleaved) Human In-Cell ELISA Kit (IR)

Technical Note Detection of post-immunoprecipitation proteins by Western blot using the Quick Western Kit IRDye 680RD

KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis)

Bioinstrumentation Light Sources Lasers or LEDs?

Quantitative analysis of PCR fragments with the Agilent 2100 Bioanalyzer. Application Note. Odilo Mueller. Abstract

SANTA CRUZ BIOTECHNOLOGY, INC.

western blotting tech

Gene Expression Technology

One-Step Western TM Kit using TMB

NovoCyte Flow Cytometer

TECHNICAL NOTE THE NEXT GENERATION OF MICROPLATES

Mini Gel Tank. Versatility. Easy loading. Enhanced visualization.

special offers from your protein biology resource

Your Research, Revolutionized

Automated Digital Microscopy

Before You Begin. Calibration Protocols

Direct visualization, sizing and concentration measurement of fluorescently labeled nanoparticles using NTA

FLOW CYTOMETRY. CyAn ADP. Analyzer

Top down proteomics approaches: (a) to monitor protein purification; (b) to resolve PTM isoforms and protein complexes

Western BLoT Ultra Sensitive HRP Substrate

GeneTools the Essential Software For Accurate DNA/RNA Gel and Blot Analysis

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

Photon Upconversion Sensitized Nanoprobes for

Infinite 200 PRO multimode microplate readers

Real-Time PCR Workshop Gene Expression. Applications Absolute and Relative Quantitation

Odyssey Western Blotting Kits LT

Flow Cytometry. Flow Cytometry Basics Guide

WesternBright Quantum

PSC 4-Marker Immunocytochemistry Kit PSC (OCT4, SSEA4) Immunocytochemistry Kit PSC (SOX2, TRA-1-60) Immunocytochemistry Kit

Thermo Scientific GENESYS 10S Bio spectrophotometer

PowerPlex Matrix Standards, 3100/3130

Spectral Separation of Multifluorescence Labels with the LSM 510 META

EGFR (Phospho-Ser695)

WANT TO IMPROVE YOUR WESTERN BLOTTING EFFICIENCY? TAKE ADVANTAGE OF OUR GREAT WORKFLOW OFFERS!

Integrated Imaging Solutions for Robust and Replicable Data

Transcription:

Sapphire Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

Breakthrough image capture and analysis The Sapphire Biomolecular Imager is a next generation laser scanning system that provides you with exceptional data quality through extremely sensitive detection, ultra high resolution and broad linear dynamic range. This system supports long and short wavelengths of near infrared fluorescence (NIR), red/green/blue (RGB) imaging, chemiluminescent imaging, phosphor imaging as well as optical densitometry (OD) of proteins in stained gels.* Improved multiplex fluorescent detection Chemiluminescence imaging, surpassing film Higher sensitivity for lower limits of detection (femtograms) Broad linear dynamic range for accurate quantitation Ease of use with intuitive control software * Patent pending

Electric Nuclear FLUORESCENCE IMAGING Improve Your Quantitation Stable fluorescent signals enable reliable quantitation of weak and strong bands Probe for multiple proteins on a single blot, and get more results from each sample CHEMILUMINESCENCE IMAGING Enhance your Detection Femtogram detection of protein The speed and sensitivity of traditional film with 4X the dynamic range PHOSPHOR IMAGING Improve Your Flexibility Scan storage phosphor screens for filmless autoradiography Wide dynamic range for sensitive detection

FLUORESCENCE Fluorescent probes are much more stable than traditional chemiluminescent methods since they do not rely on enzyme activity and substrate breakdown. This makes them ideal for quantitative analysis delivering consistent signal even months after the initial analysis. Choose from multiple fluorescent dyes for sensitive results. Supporting a wide range of visible and NIR dyes, the Sapphire Biomolecular Imager enables low limits of detection. 371 pg 0.72 pg 1484 pg 2.9 pg 1484 pg 2.9 pg Sample AzureSpectra 490 labeled purified BSA Imaging 488 LOD 0.72 pg DR 6.3 Linearity R 2 =0.99 Sample AzureSpectra 550 labeled purified transferrin Imaging 520 LOD 2.9 pg DR 5.7 Linearity R 2 =0.992 Sample AzureSpectra 650 labeled purified transferrin Imaging 658 LOD 2.9 pg DR 5.7 Linearity R 2 =0.993 742 pg 1.45 pg 1484 pg 2.9 pg Sample AzureSpectra 700 labeled purified transferrin Imaging 658 LOD 1.45 pg DR 6.0 Linearity R 2 =0.999 Sample AzureSpectra 800 labeled purified transferrin Imaging 780 LOD 2.9 pg DR 5.7 Linearity R 2 =0.99

FLUORESCENCE: APPLICATIONS Quantitative Western Blots Fluorescent Westerns enable quantification of post-translation modifications without stripping and reprobing. Spectrally separate the channels to resolve protein changes, and use a loading control to normalize for lane to lane loading variation. Cy3 IR 700 IR 800 Multiplex fluorescent detection of STAT1 (Cy3), Phospho-STAT1 (IR700), and GAPDH (IR800) in HeLa lysates. Composite image shows simultaneous detection of three proteins. See multiple proteins on the same blot With multiplex fluorescence, you can detect up to 4 targets simultaneously, with a high degree of sensitivity in each channel. Reduce errors from blot to blot variations by probing for multiple targets on the same blot, without stripping and reprobing. With the Sapphire Biomolecular Imager, up to 4 different fluorescent probes can be used and imaged at once. AzureSpectra 490 Azure Spectra 550 AzureSpectra 700 AzureSpectra 800

FLUORESCENCE: APPLICATIONS High Resolution Gel Imaging 2D Electrophoresis and 2D-DIGE are used to accurately quantitate subtle changes in protein expression. High sensitivity, broad dynamic range, and resolution down to 10 microns make the Sapphire Biomolecular Imager suited for 2D electrophoresis applications, enabling you to detect changes in complex samples. Laser-based imaging delivers sharp and crisp DNA and protein gel images. Common DNA dyes such as EtBr and SYBR Green allow you to detect your DNA size or concentration. Visible protein stains, such as Coomassie Blue, and fluorescent protein stains, like Sypro Ruby, are also compatible with the Sapphire Biomolecular Imager. Mass (pg) 625 313 156 78 39 20 SYBR Green 488 nm EtBr 520 nm SYBR Green 520 nm Representative gels showing 3kb of DNA ladder. 5000 pg 5 pg Untreated HeLa lysate was labeled with Cy3. Treated HeLa lysate was labeled with Cy5. Samples were simultaneously separated using IEF in the first dimension and SDS-PAGE in the second dimension. Purified transferrin was serially diluted 1:1 from 5000 pg to 5 pg and separated using SDS-PAGE in a 4-15% Tris-Glycine gel. After separation, the gel was stained using Coomassie Blue and imaged using the 658 laser of the Sapphire Biomolecular Imager.

FLUORESCENCE: APPLICATIONS Cell-Based ELISAs Slide-Based Imaging Detect proteins in fixed cultured cells using target-specific primary antibodies and fluorescently conjugated secondary antibodies. Quickly and accurately measure relative protein expression in multiple samples, targeting several proteins with spectrally distinct dyes. High resolution imaging, down to 10 microns, enables visualization of small features. Image fluorescent DNA and protein arrays, or tissue slides on the Sapphire Biomolecular Imager. HeLa cells were serially diluted and seeded into a 96-well plate, cultured, fixed and permeabilized, then probed for Tubulin with AzureSpectra 550 (520 channel, green), beta-actin with AzureSpectra 800 (780 channel, blue) and RedDot 1 Nuclear Stain as a normalization control (780 channel, red). Full Moon BioSystems Scanner Calibration Slide scanned at 10 µm resolution using the 520 nm and 658 nm channels of the Sapphire Biomolecular Imager.

CHEMILUMINESCENCE The sensitivity of chemiluminescent detection provides fast detection of low abundance proteins. Chemiluminescence can be more sensitive than other detection techniques due to the amplification of signal by enzyme activity. Additionally, most samples have no background signal, and are ideal for researchers who want the cleanest images. 305 fg 313 pg

CHEMILUMINESCENCE: APPLICATIONS Western Blotting Digital imaging enables a wide dynamic range for chemiluminescent imaging. Traditional film saturates quickly, making it hard to distinguish weak and strong bands simultaneously. SAPPHIRE BIOMOLECULAR IMAGER FILM Signal Intensity Signal Intensity pg Protein pg Protein Purified transferrin serially diluted and detected with chemiluminescent Western using Azure Radiance Substrate. Exceptional signal over background ratios allow for detection of small quantities of protein with the Sapphire Biomolecular Imager compared to film. Simultaneous imaging of chemiluminescent samples and colored molecular weight markers. Images are captured serially, and then overlaid within the capture software.

PHOSPHOR IMAGING To detect radioactive signals using phosphor imaging, samples containing radiolabeled samples are exposed to a storage phosphor screen. Light is emitted from the screen in proportion to the amount of radioactivity in the sample upon laser-induced stimulation. Filmless autoradiography 5 0.036 4.5 µci/g Log Integrated Intensity 4 3 2 1 American Radiolabeled Chemicals Carbon-14 standard exposed to Storage Phosphor Screen for three hours then imaged on the Sapphire Biomolecular Imager. 0 1 2 3 Log nci/g 4 5 6 Sample 14 C autoradiographic standard Imaging Phosphor LOD 0.036 µci/g DR 5.4 orders of magnitude Linearity R 2 =0.99

IMAGE CAPTURE AND ANALYSIS Workflow software for gels and blots Application driven software makes setting up imaging protocols simple. Sapphire Capture software is designed to walk you through the steps to set up the perfect imaging parameters. AzureSpot Analysis software designed for quantitation. View and analyze single and multichannel images.

TECHNOLOGY DRIVEN PERFORMANCE Discover more with a laser-based imager. The quality of excitation light affects image quality and your ability to detect subtle changes. The Sapphire Biomolecular Imager uses up to 4 solid state lasers as excitation sources. 488 nm 520 nm 658 nm 784 nm BLUE GREEN RED NEAR INFRARED AzureSpectra 490 AzureSpectra 550 AzureSpectra 650 AzureSpectra 700 AzureSpectra 800 Dylight 488 Dylight 550 Dylight 650 Dylight 800 AlexaFluor 488 Alexa Fluor 546 Dylight 680 Alexa Fluor 790 Cy2 Cy3 Cy5 Cy7 Cy5.5 BODIPY 500/510, FL APF Fluorescein (FITC) GFP Rhodamine 110 SYBR Gold, Green, Safe Rhodamine TAMRA TRITC RFP SYPRO Ruby IRDye 680 IRDye 800

1 2 3 PHOTON MULTIPLIER TUBE (PMT) AVALANCHE PHOTODIODE (APD) CHARGE-COUPLED DEVICE (CCD) Highly sensitive photodetector Focusing electrode Secondary electrons High quantum efficiency in the NIR Samples the entire spectrum simultaneously, and allows long integration times Primary electron Photocathode Dynode Anode Connector pins The Sapphire Biomolecular Imager s patent pending design uses 3 different detection modes to deliver ultimate application flexibility. Using PMTs, APDs, and CCD, the Sapphire is a unique system designed for visible fluorescence, NIR fluorescence, and chemiluminescent imaging.

Choose from three models SAPPHIRE NIR NIR Fluorescence Chemi Imaging Phosphor Imaging ü optional optional SAPPHIRE RGB RGB Fluorescence Chemi Imaging Phosphor Imaging ü optional optional SAPPHIRE RGBNIR RGB Fluorescence NIR Fluorescence Chemi Imaging Phosphor Imaging ü ü optional optional

Specifications Sapphire NIR Sapphire RGB Sapphire RGBNIR Part number IS1000 IS1001 IS1002 Laser excitation wavelengths 658, 784 488, 520, 658 488, 520, 658, 784 Bit depth 16 bit 16 bit 16 bit Scanning area 25 cm X 25 cm 25 cm X 25 cm 25 cm X 25 cm Scanning mode Simultaneous Simultaneous Simultaneous Resolution 10 micron 1000 micron 10 micron 1000 micron 10 micron 1000 micron Detectors Avalanche Photodiode Photomultiplier Tube, Avalanche Photodiode Photomultiplier Tube, Avalanche Photodiode Scanning speed 50 cm/s 50 cm/s 50 cm/s Filters Red 710/40, IR 832/37 Blue 518BP22, Green 565BP24, Red 710BP40 Blue 518BP22, Green 565BP24, Red 710BP40, IR 832/37 Dimensions (W X H X D) 75 cm X 45 cm X 70 cm 75 cm X 45 cm X 70 cm 75 cm X 45 cm X 70 cm Weight 140 lbs 140 lbs 140 lbs Power requirements 100 240 VAC ± 10%, 50/60 Hz 100 240 VAC ± 10%, 50/60 Hz 100 240 VAC ± 10%, 50/60 Hz Computer Windows 10 laptop Windows 10 laptop Windows 10 laptop Chemiluminescent Upgrade Optional Optional Optional Imaging area, chemiluminescent 16 cm X 13 cm 16 cm X 13 cm 16 cm X 13 cm Bit depth 16 bit 16 bit 16 bit Resolution 2688 X 2200 2688 X 2200 2688 X 2200 Imaging time 0-60 minutes 0-60 minutes 0-60 minutes Visible imaging Yes Yes Yes Phosphor Imaging Module Optional Optional Optional Sample types Storage phosphor screen (imaging plate) Storage phosphor screen (imaging plate) Storage phosphor screen (imaging plate)

6761 Sierra Court, Suite F Dublin, CA 94568 USA Phone: 925.307.7127 Fax: 925.905.1816 info@azurebiosystems.com www.azurebiosystems.com Copyright 2017 Azure Biosystems. All rights reserved. The Azure Biosystems logo, Azure Biosystems, and Sapphire are trademarks of the Company. Alexa Fluor and QDots are a trademark of Molecular Probes, Inc. Cy3, Cy5 and Cy2 are registered trademarks of Amersham Biosciences. DyLight is a trademark of Thermo Fisher Scientific Inc. RedDot is a trademark of Biotium. All other trademarks, service marks and trade names appearing in this brochure are the property of their respective owners.