T5 Tube Light Ideal for decorative and ambient lighting in retail outlets, hotels, warehouses, government buildings, and multi-unit residences T5 Tube UL, cul Pending Light DLC Pending (T5 Tube is compatible for the traditional ballast tube) "Built-In AC Power" Germany Patent: Gebrauchsmusters / Nr. 20 2011 052 005.6 Japan Patent: Registration : 3173203 The T5 Tube Light is the smart alternative to a fluorescent T5 lamp. The unique tube design provides omni-directional with only 16 watts of power High efficacy LED accent light 30,000-hour rated average life Superior color rendering with 80CRI Instant-on light Emits virtually no UV/IR light in the beam Contains no mercury Unsurpassed light uniformity Offers omni-directional light for ambient illumination * * Easy to experience 5-year limited warranty It's not necessary to remove the ballast and starter
T5 Tube Light Product specification (Subject to change without notice) Power (watts) Dimension LT-T512-16WE09 16W Dia.18 x 1149mm MOL (Inches) 48 Light base IP Grade Certification Warranty G5 IP52 IEC., SAA., PSE., CE., ROHS.,( UL, cul, DLC Pending ) 5 years Electrical and Technical Data (Subject to change without notice) Power (watts) Input Voltage Input Frequency LT-T512-16WE09 16W 100-277V 50-60Hz 120 >0.9 30,000 Min.80 4000-6000 View Angle PF Rated Avg. Life (Hours) CRI Color Temp. (Kelvin) Approx. Lumens @4000K 1635lm-milky cover Approx. Lumens @5000K, 6000K 1735lm-milky cover Shipping Data (Subject to change without notice) Net Weight (g) Inner box Dimensions (Dia x L) (mm) Carton Dimensions (L x W x H) (mm.) Qty. of Per Carton Per Carton Gross Weight (KG) LT-T512-16WE09 200 25 x 1222 1245 x 224 x 235 60pcs 12.2 Approx. Qty. of per Approx. Qty. of per 20 container (pcs.) 40 container (pcs.) Luminance Distribution (Subject to 1150mm tube 120 view angle)
Quick Install ation Guide T5 Tube Light Energy Saving Data Energy Efficiency, Reduces carbon dioxide emissions Estimated Lighting Costs Using a 28W Fluorescent tube Present Wattage 32 W x Annual Operating Hours 3,000 hrs = 96,000 watt-hours... 1,000 = 96 kwh per year x kwh rate of $0.11 = $10.56 per year x 100 lamps per space = $ 1056 annual energy cost per space Estimated Lighting Costs Using a 16W T5 Tube Light Present Wattage 16 W x Annual Operating Hours 3,000 hrs = 48,000 watt-hours... 1,000 = 48 kwh per year x kwh rate of $0.11 = $5.28 per year x 100 lamps per space = $528 annual energy cost per space Total Estimated Annual Savings = $528 Energy saving rate: 53.1% Reducing carbon dioxide emissions: 3 ton CO2 /year Based on 100 lamps per space operating at 3,000 hours per year. This energy saving example shows an application of 100 tubes in a space currently using 100 incandescent 28W, operating 3,000 hours per year at a cost of $0.11 per kwh. Your actual savings may vary depending on the energy costs in your geographic location. Replacing 100 standard incandescent 28W fluorescent tubes with the 16W T5 Tube Light can provide significant energy cost savings of $528 per year! Potential savings from the reduction savings from the reduction in HVAC costs as a result of using a lower wattage bulb that emits less heat is an additional benefit not included in this example.
Instructions Please take the time to read this quick installation guide. The guide contains important information and notes regarding the installation and operation of the T5 Tube Specifier Series. This T5 Tube Specifier Series are suitable to replace T5 fluorescent lights. During replacement rewiring is NOT necessary; please follow the installation steps. Traditional fluorescent tube wiring diagram VS This T5 Tube Light wiring diagram ( Need not Retrofit ) One Tube V Replace Instructions 1. Remove diffuser (if applicable) and fluorescent tube. 2. You Need NOT retrofit all wires which connected to ballast. 3. Install this tube light directly. 4. Repeat steps 1 to 3 for each additional bulb\ ballast based on illustration below. Two Tubes and one ballast VS Three/Four Tubes and one ballast Luminare Description 1. This Tube Light is suitable for installation in T5 standard luminaries. 2. Ensure all parts and accessories are in the package, VS included instruction, filed- applied label and tubular lamp. 3. Please make sure the existed luminaire dimension is large enough to replace the Tubes Lights. Three/Four Tubes and two ballasts V
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS WARNING: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 1. Risk of fire or electric shock. The electrical rating of these products are 100~277V. The installer must determine whether they have 100~277V at the luminaire before installation. 2. Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when installing the reflector kit hardware. Check for enclosed wiring and components. 3. Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. 4. Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings. 5. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. 6. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation DANGE R RISK - OF SHOCK-DISCONNECT POWER BEFORE INSTALLATION. CAUTI ONS: 1. Suitable for dry and damp locations. 2. Do not use with Dimmers. 3. Not for use in totally enclosed luminaires. 4. This d evice is not intended for use with emergency exit fixtures or emergency lights. 5. Before replacing, turn off power and let lamp cool to avoid electrical shock or burn. 6. Risk of electric shock. Do not use where directly exposed to water. 7. This d evice is not intended for use with emergency exits. 8. Lamps must be operated within an ambient fixture temperature of -22F (-30c) and 113F (45c) co comply with all safety and warranty regulatio ns. Light and Energy International, LLC, P.O. Box 51960, Sparks, NV 89434 USA