Utility Cabinet System (UCS)

Similar documents
SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

INDUSTRIAL GUARDRAIL SYSTEMS

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Architectural Specifications, Section Phenolic Lockers

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

A. Access doors and frames are part of an access door and frame allowance.

SECTION DIRECTORIES

OPERABLE PARTITIONS. Signature

SECTION EXTERIOR GRILLS AND SCREENS

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION GYPSUM BOARD ASSEMBLIES

DIVISION 13 - SPECIAL CONSTRUCTION SECTION ACOUSTICAL PANEL ENCLOSURE

Record Master SHELVING SYSTEMS

Post Style with ABS Real Tuff

Division 11 - Equipment Section 11401

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

Product Specifications MRI Trench Duct

PH6000. Key Features

McNICHOLS. McNICHOLS ECO-MESH System MODULAR FAÇADE AND TRELLIS SYSTEMS...

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES

Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass

A. Submit the following in addition to the standard requirements.

SECTIONAL DOOR SYSTEMS

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Keylar Shelving (QLD) Pty Ltd

SECTION CLIMBING WALLS

Vertigo Cladding Board

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

SECTION ALUMINUM GATES

PIP STF05521 Details for Angle Railings for Walking and Working Surfaces

SECTION HVAC GRAVITY VENTILATORS

Outdoor + Switchgear, Walk-in Equipment Buildings Low & Medium Voltage NEMA 3R

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

SECTION SECTIONAL OVERHEAD DOORS

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

WHAT IS CANTILEVER RACK?

Selecting Cover Systems

SECTION IMPACT RESISTANT WALL PROTECTION

Planning and installation instructions

Power Zone Center. Your solution for power distribution and control systems

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

A. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION EXPANSION CONTROL

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

Built to Order. Stile. Frames. Section Contents. Profiles. Elevations. Double Egress Frames Pocket Frames

Industry Standard Terms & Definitions Of The Steel Deck Institute

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES

RUUKKI FORMA DESIGN INSTRUCTION

1.1.2 All window frames will be Kite marked to indicate compliance with these standards.

MODEL: IMPULSE - DUAL SIT/STAND CONSOLES

Government Market Brochure GSA Contract GS-07F-6106P

Fully framed glass panels

COMPLETE REVISION November Process Industry Practices Architectural. PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

A-Series Aluminum Gantry Crane

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

CTC PROFILES FOR CARPET

SECTION 1043 FENCE MATERIAL

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

SECTION RESILIENT SHEET FLOORING

SECTION ROLLER GATES

Fire protection, soundproofing and thermal insulation


University Apartments on Brooklyn PROJECT MANUAL

KIOSK DESIGN CRITERIA

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Transcription:

(UCS) The Ultimate in Stainless Steel Modular Walls UCS: Eliminates the need and the costs of constructing a traditional wall Provides easier access and faster installation of the utilities compared to traditional wall construction Allows for future modifications of the utilities unlike a traditional wall construction www.streivor.com

Panels removed Quick and Easy Access Panels in place Streivor s provides the perfect alternative to standard stud and sheetrock walls that use tile, stainless steel and/or fiberglass reinforced plastic panels for the outer covering. The outer shell of the is fabricated from heavy gauge Type 304 #4 Stainless Steel with a 180 grit one directional polish, thus UCS walls provide an aesthetically pleasing, durable, flexible cabinet system that is easy to install, easy to clean and easy to maintain at a cost that is competitive with a standard stud and sheetrock walls. In addition, UCS walls are fitted with removable panels that allow easy access to the inside of the cabinet to make additions and/or modifications to the utilities. Call 1 888-343-6464 www.streivor.com

Exterior Finishes s can be custom manufactured with various outer surface finishes other than Type 304 #4 Stainless Steel. Materials such as decorative metals or glass can be included in the exterior UCS design. The UCS can also be powder coated in a multitude of colors and/or supports the installation of ceramic tiles. with inset ceramic tiles www.streivor.com Call 1 888-343-6464

Installation All s are fully assembled in the factory per customer specifications. The UCS is then disassembled and each part is clearly marked prior to shipping. Streivor also provides a detailed, easy to understand assembly drawing for reassembly in the field. The Utility Cabinets are reinforced with 1" x 1" angle iron framing that facilitates anchoring to the floor and/ or structure above. Call 1 888-343-6464 www.streivor.com

with panels removed Utility Installation The is designed with easily removable and replaceable panels. When the panels are removed, contractors have complete access to the inside of the cabinet and the Unistrut Utility Support Channels. The inside of the is completely unobstructed and the contractor does not have to drill or cut any holes through any studs or obstructions to install conduit or piping. All of the conduit and piping quickly fastens to the Utility Cabinet s inner Unistrut frame and connects to junction boxes, or is passed though the knockouts pre-engineered at the factory. Once the contractor completes the installation, they can replace the removable panels to close the cabinet. The panels can be removed and/or replaced at any time in the future allowing for easy utility inspection, modification and/or repair. www.streivor.com Call 1 888-343-6464

Human Machine Interface mounted to the side of the vertical wall. Vertical walls provide ideal locations for the installation of Demand Ventilation Controls and other electrical switches. Easy to Clean and Maintain The outer shell is fabricated out of Type 304 Stainless Steel, which is an ideal material for withstanding today s harshest commercial kitchen environments. When properly maintained, cabinets can withstand water and other moisture without deterioration and also helps prevent mold from developing. Call 1 888-343-6464 www.streivor.com

Durable & Flexible The heavy gauge stainless steel outer shell provides a durable surface that can withstand the heaviest traffic of a commercial kitchen. Cabinets have galvanized plated Unistrut channels that are welded to stainless steel hat channels. The UCS also has an angle iron frame for anchoring to the building. s can be fabricated in standard or custom sizes. Junction boxes, knockouts sizes and their positions are also customizable. www.streivor.com Call 1 888-343-6464

UCS-1: Removeable Panels 1 Side *Typically installs against a wall UCS-2: Removeable Panels 2 Sides *Typically installs in an island configuration Vertical Cabinets: Removable upper and lower cabinet door with recessed pulls 1" x 1" x.125" thick angle iron mounting frame on the top and bottom of the vertical cabinets Heavy Duty 12 Gauge Galvanized Unistrut frame for mounting pipe and conduit 1ea 2" x 4" junction box with stainless steel cover 1ea 4" x 4" junction box with stainless steel cover Horizontal Cabinets: Removable panels with recessed pulls Heavy Duty 12 Gauge Galvanized Unistrut frame for mounting pipe and conduit 2" x 4" junction boxes with stainless steel cover on 30" maximum centers 4" x 4" junction boxes with stainless steel cover on 30" maximum centers 2.5" and 1.5" round alternating knockouts along the underside of the cabinet spaced on 12" centers www.streivor.com 2150 Kitty Hawk Road, Livermore, CA 94551 Phone: (925) 960-9090 Fax: (925) 960-9055 3.2017 Copyright Streivor, Inc.