NEC 2014 Code Changes

Similar documents
WIRING METHODS CHAPTER 38

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.

Revisions for the 2011 National Electrical Code - Part 2

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Basic Requirements for Residential Electrical Installations

SECTION GROUNDING AND BONDING

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

1. Approved Manufacturers: Carlon Electrical Products, Cantex, or approved equal.

Table of Contents. Preface

Article 300: Wiring Methods And Materials

(Condensed from National Electric Code)

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

CHAPTER 11 CONDUITS AND FITTINGS

2011 National Electrical Code Update Training. Henrico County Department of Building Construction and Inspections

2011 National Electrical Code Update Training

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

Panel 7 Proposals For 2005 NEC Articles 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 382, 394, 396 and 398

UNDERGROUND SERVICES SECONDARY

ELECTRICAL BULLETIN

ELECTRICAL BULLETIN

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

Standard of Practice - Campus Electrical Distribution System

Temporary Wiring Practices And Guidelines For NECA. National Electrical Contractors Association Omaha, Nebraska

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

2015 Code Rollout Meeting Q & A

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

B. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83.

CONDUITS AND FITTINGS

Summary of the Changes 2017 National Electrical Code

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

Specifications for Residential Overhead Electric Service Installation

CITY OF GRANDE PRAIRIE

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

Section 2: Underground

ELECTRICAL SAFETY FOLLOW UP INSPECTION REPORT (4th)

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

St. Clair County Electrical Code Regulations

Telecommunication Spaces

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

AGENDA. NEC Code-Making Panel 6. Report on Comment Meeting. December 6 December 8, Redondo Beach, CA

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion).

GILA RIVER FIRE DEPARTMENT REQUIREMENTS

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

SECTION BASIC ELECTRICAL REQUIREMENTS

National Electrical Installation Standard. Type AC Cable and Type MC Cable. NACMA Draft 4

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

TYPICAL INSTALLATION INSTRUCTIONS

Installation of CSST Gas Piping Systems

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

CHAPTER 29 PLUMBING SYSTEMS

Electric Service Requirements. Residential Overhead. Engineering Specification T002. February

Emergency, Legally Required, and Optional Standby Power Systems

SECTION INSULATED WIRE AND CABLE

ELECTRICAL CODE TRADE REFERENCE

Underground Service Requirements and Instructions

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

Specifications Electrical Metallic Tubing (EMT)

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

The Inspection Process. Waxhaw N.C.

A. Product Data shall be provided for each type of product indicated.

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

296-4B-010 thru 110. Adopted standards - inspectors - city inspection - variance.

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

STABILOY Brand MC Cable InSTALLATION GUIDE

PORT OF SAN FRANCISCO ELECTRICAL CODE. Based on the 2016 California Electrical Code

Specification Lightning Protection Systems

DOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING) B ADDRESS AND DETAILS OF THE INSTALLATION Address: SPECIMEN

Electric Service Standards

National Electrical Installation Standard. Type AC Cable and Type MC Cable. NACMA Draft 4. Page - 1

CONSULTING ENGINEERS 5145 Livernois, Suite 100 Troy, Michigan Tel: Fax:

ELECTRIC METERING GENERAL

GENERAL PLAN REVIEW REQUIREMENTS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

ELECTRICAL SAFETY INSPECTION REPORT

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction

Permitting and Inspecting PV Systems. PV Codes and Standards 101. Photovoltaic System Basics

Questions & Answers. Amendments to Ontario Electrical Safety Code 23 rd Edition/2002

Basic Service. This Section provides information regarding a. Introduction

FREQUENTLY ASKED QUESTIONS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.

CAL/OSHA ELECTRICAL HIGH VOLTAGE

SECTION WIRES AND CABLES

Transcription:

NEC 2014 Code Changes Articles 280.21-300.50 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1000 volts II. Instillation III. Connecting Surge Arresters 280.21 Connection The arrester will be connected to one of the following: (1)Grounded service conductor (2) Grounding electrode conductor (3) Grounding electrode for the service (4) Equipment grounding terminal in the service equipment 280.24 Interconnections The surge arrester protecting a transformer that supplies a secondary distribution system will be interconnected as specified in section 280.24(A), (B), or (C). 2014 All Star Training Inc. 1

(A) Metallic Interconnections A metallic interconnection will be made to the secondary grounded circuit conductor or the secondary circuit grounding electrode conductor provided that, in addition to the direct grounding connection at the surge arrester, the following occurs: (B) Through Spark Gap or Device Where the surge arrester grounding electrode conductor is not connected as in section 280.24(A) or where the secondary is not grounded as in section 280.24(A) but is otherwise grounded as in section 250.52, an interconnection will be made through a spark gap or listed device as required by section 280.24(B)(1) or (B)(2): 280.25 Grounding Electrode Conductor Connections and Enclosures Except as indicated in this article, surge-arrester grounding electrode conductor connections will be made as shown in Article 250 Parts III and X. Grounding electrode conductors installed in metal enclosures will adhere to section 250.64(E). ARTICLE 285 Surge-Protective Devices (SPD s), 1000 volts or Less 285.1 Scope. This article covers general requirements, installation requirements, and connection requirements for surge-protective devices (SPDs) permanently installed on premises wiring systems of 1000 volts or less. 2014 All Star Training Inc. 2

Informational Note: Surge arresters 1000 volts or less are also known as Type 1 SPDs. 285.13 Type 4 and Other Component Type SPDs. Type 4 component assemblies and other component type SPDs shall only be installed by the equipment manufacturer. III. Connecting SPD s 285.23 Type 1 SPD s (B) At the Service When installed at services, Type 1 SPD s will be connected to one of the following grounds: (1) Grounded service conductor (2) Grounding electrode conductor (3) Grounding electrode for the service (4) Equipment grounding terminal in the service equipment 285.24 Type 2 SPDs. Type 2 SPDs shall be installed in accordance with 285.24(A) through (C). 2014 All Star Training Inc. 3

(A) Service-Supplied Building or Structure. Type 2 SPDs must be connected anywhere on the load side of a service disconnect over-current device required in 230.91, unless installed in accordance with 230.82(8). (B) Feeder-Supplied Building or Structure. Type 2 SPDs are to be connected at the building or structure anywhere on the load side of the first over-current device at the building or structure. (C) Separately Derived System. The SPD must be connected on the load side of the first over-current device in a separately derived system. 285.25 Type 3 SPD s Type 3 SPD s (TVSS s) will be allowed to be installed on the load side of branch circuit overcurrent protection up to the equipment served. If included in the manufacturer s instructions, the Type 3 SPD connection will be a minimum of 10 m (30 ft.) of conductor distance from the service or separately derived system disconnect. 285.27 Connection Between Conductors An SPD (surge arrester or TVSS) will be allowed to be connected between any two conductors ungrounded conductors, grounded conductor, equipment grounding conductor, or grounding electrode conductor. During a surge the grounded 2014 All Star Training Inc. 4

conductor and the equipment grounding conductor will be interconnected only by the normal operation of the SPD (surge arrester or TVSS) during a surge. 285.28 Grounding Electrode Conductor Connections and Enclosures Except as indicated in this article, SPD grounding connections will be made as shown in Article 250 Part III. Grounding electrode conductors installed in metal enclosures will adhere to section 250.64(E). Chapter 3 - Wiring Methods and Materials ARTICLE 300 General Requirements for Wiring Methods and Materials 300.2 Limitations. (A) Voltage. Wiring methods specified in Chapter 3 must be used for 1000 volts, nominal, or less where not specifically limited in some section of Chapter 3. They shall be permitted for over 1000 volts, nominal. 300.3 Conductors (A) Single Conductors Single conductors specified in Table 310.104(A) will only be installed if they are part of a recognized wiring method of Chapter 3. (B) Conductors of the Same Circuit 2014 All Star Training Inc. 5

(1) Paralleled Installations Conductors will be allowed to run in parallel according to section 310.10(H). The requirement to run all circuit conductors within the same raceway, auxiliary gutter, cable tray, trench, cable, or cord will apply separately to each portion of the paralleled installation, and the equipment grounding conductors will adhere to section 250.122. Parallel runs in cable tray will adhere to section 392.8(D). (C) Conductors of Different Systems (1) 1000 Volts, Nominal, or Less Conductors of ac and dc circuits, rated 1000 volts, nominal, or less, will be allowed to occupy the same equipment wiring enclosure, cable, or raceway. All conductors will have an insulation rating equal to at least the maximum circuit voltage applied to any conductor within the enclosure, cable, or raceway. Secondary wiring to electric-discharge lamps of 1000 volts or less, if insulated for the secondary voltage involved, shall be allowed to occupy the same luminaire, sign, or outline lighting enclosure as the branch-circuit conductors. (2) Over 1000 Volts, Nominal. Conductors of circuits rated over 1000 volts, nominal, are not permitted to occupy the same equipment wiring enclosure, cable, 2014 All Star Training Inc. 6

or raceway with conductors of circuits rated 1000 volts, nominal, or less unless otherwise permitted in 300.3(C)(2)(a) through (C)(2)(d). (a) Primary leads of electric-discharge lamp ballasts insulated for the primary voltage of the ballast, where contained within the individual wiring enclosure, are permitted to occupy the same luminaire, sign, or outline lighting enclosure as the branch-circuit conductors. (b) Excitation, control, relay, and ammeter conductors used in connection with any individual motor or starter are permitted to occupy the same enclosure as the motor-circuit conductors. (c) In motors, transformers, switchgear, switchboards, control assemblies, and similar equipment, conductors of different voltage ratings are permitted. (d) In manholes, if the conductors of each system are permanently and effectively separated from the conductors of the other systems and securely fastened to racks, insulators, or other approved supports, conductors of different voltage ratings are allowed. Conductors having non-shielded insulation and operating at different voltage levels must not occupy the same enclosure, cable, or raceway. 300.4 Protection Against Physical Damage If they are subject to physical damage, conductors, raceways, and cables will be protected. 2014 All Star Training Inc. 7

(E) Cables, Raceways, or Boxes Installed in or Under Roof Decking A cable raceway, or box, installed in exposed or concealed locations under metalcorrugated sheet roof decking, will be installed and supported so that there is no less than 38 mm (1 ½ in.) measured from the lowest surface of the roof decking to the top of the cable, raceway, or box. A cable, raceway, or box will not be installed in concealed locations in metal-corrugated, sheet decking-type roof. (G) Insulated Fittings Where raceways contain 4 AWG or larger insulated circuit conductors and these conductors enter a cabinet, box, enclosure, or raceway, the conductors will be protected by an identified fitting providing a smoothly rounded insulating surface, unless the conductors are separated from the fitting or raceway by identified insulating material that is securely fastened in place. (H) Structural Joints A listed expansion/deflection fitting or other approved means will be used where a raceway crosses a structural joint intended for expansion, contraction or deflection, used in buildings, bridges, parking garages, or other structures. 300.5 Underground Installation 2014 All Star Training Inc. 8

(A) Minimum Cover Requirements. Direct-buried cable or conduit or other raceways must be installed to meet the minimum cover requirements of Table 300.5. (B) Wet Locations. The interior of enclosures or raceways installed underground are to be considered to be a wet location. Insulated conductors and cables installed in these enclosures or raceways in underground installations shall comply with 310.10(C). Any connections or splices in an underground installation must be approved for wet locations. (C) Underground Cables and Conductors Under Buildings. Underground cable and conductors installed under a building must be in a raceway. Exception #1: Type MI Cable will be allowed under a building without insulation in a raceway where embedded in concrete, fill or other masonry according to section 332.10(6) or in underground runs where suitably protected against physical damage and corrosive conditions according to section 332.10(10) Exception #2: Type MC Cable listed for direct burial or concrete encasement will be allowed under a building without installation in a raceway according to section 330.10(A)(5) and in wet locations according to section 330.10(11). 2014 All Star Training Inc. 9

(D) Protection from Damage. Direct-buried conductors and cables are to be protected from damage in accordance with 300.5(D)(1) through (D)(4). (1) Emerging from Grade. Direct-buried conductors and cables emerging from grade and specified in columns 1 and 4 of Table 300.5 must be protected by enclosures or raceways extending from the minimum cover distance below grade required by 300.5(A) to a point at least 2.5 m (8 ft) above finished grade. In no case shall the protection be required to exceed 450 mm (18 in.) below finished grade. (2) Conductors Entering Buildings. Conductors entering a building must be protected to the point of entrance. (3) Service Conductors. Underground service conductors that are not encased in concrete and that are buried 450 mm (18 in.) or more below grade are to have their location identified by a warning ribbon that is placed in the trench at least 300 mm (12 in.) above the underground installation. (4) Enclosure or Raceway Damage. Where the enclosure or raceway is subject to physical damage, the conductors shall be installed in rigid metal conduit, intermediate metal conduit, RTRC-XW, Schedule 80 PVC conduit, or equivalent. (E) Splices and Taps. Direct-buried conductors or cables shall be permitted to be spliced or tapped without the use of splice boxes. The splices or taps shall be made in accordance with 110.14(B). 2014 All Star Training Inc. 10

(F) Backfill. Backfill that contains large rocks, paving materials, cinders, large or sharply angular substances, or corrosive material shall not be placed in an excavation where materials may damage raceways, cables, or other substructures or prevent adequate compaction of fill or contribute to corrosion of raceways, cables, or other substructures. Where necessary to prevent physical damage to the raceway or cable, protection must be provided in the form of granular or selected material, suitable running boards, suitable sleeves, or other approved means. (G) Raceway Seals. Conduits or raceways through which moisture may contact live parts shall be sealed or plugged at either or both ends. Informational Note: Presence of hazardous gases or vapors may also necessitate sealing of underground conduits or raceways entering buildings. (H) Bushing. A bushing, or terminal fitting, with an integral bushed opening is to be used at the end of a conduit or other raceway that terminates underground where the conductors or cables emerge as a direct burial wiring method. A seal incorporating the physical protection characteristics of a bushing is permitted to be used instead of a bushing. (I) Conductors of the Same Circuit All conductors of the same circuit and, where used, the grounded conductor and all equipment grounding conductors are to be 2014 All Star Training Inc. 11

installed in the same raceway or cable or installed in close proximity in the same trench. Exception #1: Conductors will be allowed to be installed in parallel in raceways, multi-conductor cables, or direct-buried single conductor cables. Each raceway or multi-conductor cable will contain all conductors of the same circuit, including equipment grounding conductors. Each direct-buried single conductor cable will be located in close proximity in the trench to the other single conductor cables in the same parallel set of conductors in the circuit, including equipment grounding conductors. Exception #2: Isolated phase, polarity, grounded conductor, and equipment grounding and bonding conductor installations will be allowed in nonmetallic raceways or cables with a nonmetallic covering or non metallic sheath in close proximity where conductors are paralleled as allowed in section 310.10(H), and where the conditions of section 300.20(B) are met. (J) Earth Movement. Where direct-buried conductors, raceways, or cables are subject to movement by settlement or frost, direct-buried conductors, raceways, or cables are to be arranged so as to prevent damage to the enclosed conductors or to equipment connected to the raceways. 2014 All Star Training Inc. 12

Informational Note: This section recognizes S loops in underground direct burial to raceway transitions, expansion fittings in raceway risers to fixed equipment, and, generally, the provision of flexible connections to equipment subject to settlement or frost heaves. (K) Directional Boring. Cables or raceways installed using directional boring equipment must be approved for the purpose. 300.7 Raceways Exposed to Different Temperatures (A) Sealing If portions of a raceway or sleeve are known to be subjected to different temperatures, and where condensation is known to be a problem, the raceway or sleeve will be filled with an approved material to prevent the circulation of warm air to a colder section of the raceway or sleeve. An explosion proof seal will not be required for this purpose. (B) Expansion Fittings. Raceways shall be provided with expansion fittings where necessary to compensate for thermal expansion and contraction. 300.9 Raceways in Wet Locations Above grade 2014 All Star Training Inc. 13

Where raceways are installed in wet locations abovegrade, the interior of these raceways will be considered to be a wet location. Insulated conductors and cables installed in raceways in wet locations abovegrade will adhere to section 310.10(C). 300.11 Securing and Supporting (2) Non-Fire Rated Assemblies Wiring located within the cavity of a non-fire-rated floor-ceiling or roof-ceiling assembly will not be secured to, or supported by, the ceiling assembly, including the ceiling support wires. An independent means of secure support will be provided and will be attached to the assembly. Where independent support wires are used, they will be distinguishable by color, tagging, or other effective means. (B) Raceways Used as Means of Support. Raceways must be used only as a means of support for other raceways, cables, or nonelectrical equipment under any of the following conditions: (1) Where the raceway or means of support is identified as a means of support (2) Where the raceway contains power supply conductors for electrically controlled equipment and is used to support Class 2 circuit conductors or cables that are solely for the purpose of connection to the equipment control circuits (3) Where the raceway is used to support boxes or conduit bodies in accordance with 314.23 or to support luminaires. 2014 All Star Training Inc. 14

300.15 Boxes, Conduit Bodies, or Fittings Where Required A box will be installed at each outlet and switch point for concealed knob-and-tube wiring. Fittings and connectors will be used only with the wiring methods for which they are designed. Where the wiring method is conduit, tubing, Type AC cable, Type MC cable, Type MI cable, non-metallic-sheathed cable, or other cables, a box or conduit body will be installed at each conductor splice point, or pull point, unless otherwise allowed in section 300.15(A) through section 300.15(L). 300.21 Spread of Fire or Products of Combustion Electrical installations in hollow spaces, vertical shafts, and ventilation of airhandling ducts will be made so that the possible spread of fire or products of combustion will not be substantially increased. Openings around electrical insertions into or through fire-resistant-rated walls, partitions, floors, or ceilings will be fire stopped using approved methods to maintain the fire resistance rating. 300.22 Wiring in Ducts Not Used for Air-Handling Fabricated Ducts for Environmental Air, and Other Spaces for Environmental Air (Plenums) 2014 All Star Training Inc. 15

The provisions of this section will apply to the installation and uses of electrical wiring and equipment in ducts used for dust, loose stock, or vapor removal; ducts specifically fabricated for environmental air; and other spaces used for environmental air (plenums). (A) Ducts for Dust, Loose Stock, or Vapor Removal. No wiring systems of any type is to be installed in ducts used to transport dust, loose stock, or flammable vapors. No wiring system of any type is permitted to be installed in any duct, or shaft containing only such ducts, used for vapor removal or for ventilation of commercial-type cooking equipment. (B) Ducts Specifically Fabricated for Environmental Air Equipment, devices, and the wiring methods specified in this section shall be allowed within such ducts only if necessary for the direct action upon, or sensing of, the contained air. Where equipment or devices are installed and illumination is necessary to facilitate maintenance and repair, enclosed gasketed-type luminaires shall be permitted. Only wiring methods consisting of Type MI cable without an overall nonmetallic covering, Type MC cable employing a smooth or corrugated impervious metal sheath without an overall nonmetallic covering, electrical metallic tubing, flexible metallic tubing, intermediate metal conduit, or rigid metal conduit without an 2014 All Star Training Inc. 16

overall nonmetallic covering must be installed in ducts specifically fabricated to transport environmental air. Flexible metal conduit is allowed, in lengths less than or equal to than 1.2 m (4 ft), to connect physically adjustable equipment and devices permitted to be in these fabricated ducts. The connectors used with flexible metal conduit must effectively close any openings in the connection. (C) Other Space Used for Environmental Air (Plenums) This section applies to space not specifically fabricated for environmental airhandling purposes but used for air-handling purposes as a plenum. This section will not apply to habitable rooms or areas of buildings, the prime purpose of which is not air handling. Further Information #2: The phase Other Spaces Used for Environmental Air (Plenum) as used in this section correlates with the use of the term plenum in NFPA 90A-2009, Standars for the Installation od Air-Conditioning and Ventilating Systems, and other mechanical codes where the plenum is used for return air purposes, as well as some other air-handling spaces. (1) Wiring Methods The wiring methods for such other spaces will be limited to totally enclosed, nonventilated insulated busway having no provisions for plug-in connections, Type MI 2014 All Star Training Inc. 17

cable, without an overall nonmetallic covering. Type MC cable without an overall non metallic covering, Type AC cable, or other factory-assembled multi-conductor control or power cable that is listed for use within an air-handling space, or listed prefabricated cable assemblies of metallic manufactured wiring systems without nonmetallic sheath. Other types of cables, conductors, and raceways will be allowed to be installed in electrical metallic tubing, flexible metallic tubing, and intermediate metal conduit, rigid metal conduit without an overall nonmetallic covering, flexible metal conduit, or, where accessible, surface metal raceway or metal wireway with metal covers. Nonmetallic cable ties and other nonmetallic cable accessories used to secure and support cables shall be listed as having low smoke and heat release properties. (2) Cable Tray Systems The provision in (a) or (b) will apply to the use of metallic cable tray systems in other spaces used for environmental air (plenums), where accessible as follows: (a) Metal Cable Tray Systems. Metal cable tray systems will be allowed to support the wiring methods in section 300.22(C)(1). (b) Solid Side and Bottom Metal Cable Tray Systems. Solid side and bottom metal cable tray systems with solid metal covers will be allowed to enclose wiring 2014 All Star Training Inc. 18

methods and cables, not already covered in section 300.22(C)(1), according to section 392.10(A) and (B). (3) Equipment Electrical equipment with a metal enclosure, or electrical equipment with a nonmetallic enclosure listed for use within an air-handling space and having adequate fire-resistant and low-smoke-producing characteristics, and associated wiring material suitable for the ambient temperature will be allowed to be installed in such other spaces unless prohibited elsewhere in this Code. Further Information: One method of defining adequate fire-resistant and lowsmoke producing characteristics for electrical equipment with a nonmetallic enclosure is in ANSI/UL 2043-2008, Fire Test Heat and Visible Smoke Release for Discrete Products and Their Accessories Insulated in Air-Handling Spaces. Exception: Integral fan systems will be allowed where specifically identified for use within an air-handling space. II. Requirements for over 1000 Volts, Nominal 300.37 Aboveground Wiring Methods: Aboveground conductors will be installed in rigid metal conduit, in intermediate metal conduit, in electrical metallic tubing, in RTRC and PVC conduit, in cable 2014 All Star Training Inc. 19

trays, in auxiliary gutters as busways, as cablebus, in other identified raceways, or as exposed runs of metal-clad cable suitable for the use and purpose. In locations accessible to qualified persons only, exposed runs of Type MV cables, bare conductors, and bare busbars will also be allowed. Busbars will be allowed to be either copper or aluminum. 300.38 Raceways in Wet Locations Above Grade. Where raceways are installed in wet locations above grade, the interior of these raceways shall be considered to be a wet location. Insulated conductors and cables installed in raceways in wet locations above grade. 300.45 Warning Signs. Warning signs shall be conspicuously posted at points of access to conductors in all conduit systems and cable systems. The warning sign(s) must be legible and permanent and shall have the following wording: DANGER HIGH VOLTAGE KEEP OUT 300.50 Underground Installations A) General. Underground conductors shall be identified for the voltage and conditions under which they are installed. Direct-burial cables shall comply with the provisions of 310.10(F). Underground cables shall be installed in accordance 2014 All Star Training Inc. 20

with 300.50(A)(1), (A)(2), or (A)(3), and the installation shall meet the depth requirements of Table 300.50. (1) Shielded Cables and Non-shielded Cables in Metal- Sheathed Cable Assemblies. Underground cables, including non-shielded, Type MC and moistureproof metal sheath cables, shall have those sheaths grounded through an effective grounding path meeting the requirements of 250.4(A)(5) or (B)(4). They shall be direct buried or installed in raceways identified for the use. (2) Industrial Establishments. In industrial establishments, where conditions of maintenance and supervision ensure that only qualified persons service the installed cable, non-shielded single-conductor cables with insulation types up to 2000 volts that are listed for direct burial are allowed to be directly buried. (3) Other Non-shielded Cables. Other non-shielded cables not covered in 300.50(A)(1) or (A)(2) shall be installed in rigid metal conduit, intermediate metal conduit, or rigid Non-metallic conduit encased in not less than 75 mm (3 in.) of concrete. (B) Wet Locations The interior of enclosures or raceways installed underground will be considered to be a wet location. Insulated conductors and cables installed in these enclosures or raceways in underground installations will be listed for use in wet locations and 2014 All Star Training Inc. 21

will adhere to section 310.10(C). Any connections or splices in an underground installation will be approved for wet locations. (C) Protection from Damage Conductors emerging from the ground will be enclosed in listed raceways. Raceways installed on poles will be of rigid metal conduit, intermediate metal conduit, RTRC-XW Schedule 80 PVC conduit, or equivalent, extending from the minimum cover depth specified in Table 300.50 to a point 2.5 m (8ft.) above finished grade. Conductors entering a building will be protected by an approved enclosure or raceway from the minimum cover depth to the point of entrance. Where direct-buried conductors, raceways, or cables are subject to movement by settlement or frost, they will be installed to prevent damage to the enclosed conductors or to the equipment connected to the raceways. Metallic enclosures will be grounded. 2014 All Star Training Inc. 22