Automated 2-D HPLC Using Trap Columns for the Fractionation, Isolation and Screening of Natural Products

Similar documents
Fast Preparative Column Liquid Chromatography (PCLC)

Accessing the E-Gel 96 System via the Quad-Z 215 with Disposable Tips

Streamlined Purification of Assay-Ready Oligonucleotides by Automated HPLC

Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions

HPLC/FLASH Purification ADVANCE THE PACE OF YOUR DISCOVERY TO ACHIEVE THE RESULTS OF TOMORROW

Preparative HPLC is still the

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Fully-Automated Workstation for Direct camp Enzyme Immunoassay Kit

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

Genotoxicity is the property of a compound

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Fundamentals and Techniques of Preparative HPLC. Parto Zist Behboud Tel: 42108

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Guide to Trap Cartridge Care and Use

Flexibility with. Preparative HPLC

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Bivalirudin Purification:

On-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

MassPREP On-Line Desalting Cartridge

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Zwitterion Chromatography ZIC

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Optimizing the Purification of a Standard Chiral Compound Utilizing a Benchtop, Multi-Purpose, Semi-Preparative to Preparative HPLC System

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Overview of preparative HPLC. Analytical Technologies Limited

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

UFFLC of the Proteome Ultra High Pressure and Ultra Fast Flow Liquid Chromatography: A New Approach To Proteomics

Technical Note. Introduction

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

EtG / EtS Analysis UCT INNOVATION THROUGH CHEMISTRY FORENSICS

The Theory of HPLC Gradient HPLC

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

Aflatoxin & Ochratoxin Analysis. A Completely Automated Solution with the Freestyle, ThermELUTE, and SMART Immunoaffinity Cleanup Columns

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Automated in-line buffer preparation from readymade stock solutions in a mab process step

Quick Manual to the Waters UPLC System

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Method Translation in Liquid Chromatography

Analysis and Purification of Polypeptides by Reversed-Phase HPLC

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Application Note. Abstract. Authors. Introduction. Environmental

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

Laboratory Water Quality Affects Protein Separation by 2D Gel Electrophoresis

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Thermo Scientific. Dionex IonPac AS9-HC. Column Product Manual. P/N: May Part of Thermo Fisher Scientific

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Rapid Extraction of Therapeutic Oligonucleotides from Primary Tissues for LC/ MS Analysis Using Clarity OTX, an Oligonucleotide Extraction Cartridge

5 AMP Sepharose 4B. instructions

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Phenyl Sepharose CL-4B

CAMAG TLC-MS INTERFACE 2

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Glyphosate and AMPA in drinking water

RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF GLATIRAMER ACETATE FOR INJECTION IN PHARMACEUTICAL DOSAGE FORMS

Determination of Cations in Hydraulic Fracturing Flowback Water from the Marcellus Shale

7 Preparative Columns

Analysis of biomolecules by SEC and Ion-Exchange UPLC

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

Application Note 00394

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Ultrahydrogel Columns

Ergonomic Pipetting for Problem Liquids!

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

Determination of Adenovirus pviii (31K) Concentration for Estimation of the Empty Capsid Concentration of the Adenovirus Reference Material (ARM)

Preparative HPLC System

BÜCHI Labortechnik AG

The practical task of monoclonal IgG purification with CHT TM ceramic hydroxyapatite

Promix TM. Enter a New Era in Biomolecule Analysis with. Columns. Unsurpassed Selectivity and Peak Capacity for Peptides and Proteins

Superdex 200 Increase columns

Practical guidance for switching between anion and cation analysis systems

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

Peptide Mapping: A Quality by Design (QbD) Approach

Preparative SFC QDa Applications in Natural Products Research Judith M. Rollinger Ulrike Grienke

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

AZURA Bio purification

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Transcription:

Automated 2-D HPLC Using Trap Columns for the Fractionation, Isolation and Screening of Natural Products Application Note 227 Joan Stevens, Ph.D., Alan Hamstra, Tim Hegeman and Luke Roenneburg (Gilson, Inc.) Introduction One aspect of 2-D chromatography that is being explored uses small reverse-phase columns to trap the eluent from the ion-exchange column at defined timed intervals. Components are then eluted from the trapping reverse-phase columns onto an analytical reverse-phase column with fraction collection for further analysis using techniques such as mass spectroscopy and bioactivity assays. All types of 2-D chromatography have an attractive characteristic: they enhance the separation of a mixture that is not possible to separate using 1-D chromatography. While manual 2-D chromatography can be a difficult process, automation of the procedures alleviates the variables and increases repeatability and throughput. A resurgence in natural product evaluation for biological activity is evident based on articles noted in scientific journals and the other media. One such natural product is Mugwort (Artemisia vulgaris), or black sage, whose components have been associated with digestive stimulant, diuretic and nerve tonic. The main chemical components of Mugwort extracts are alpha, beta-thujones, 1, 8-cineole, camphene and camphone, which have associative affects of neurotoxicity and abortifacient. Materials & Methods Instrumentation and Software 215 Liquid Handler: equipped with 819 Injection Module with 500-µL injection loop, low-mount fraction collection valve (3) VALVEMATE Valve Actuator: equipped with 7610 Rheodyne (1), 10-port, 2-position; and 7060 Rheodyne (2), 6-position, selector valve (2) UV/VIS Detector: high-pressure analytical flow cell (1), 5-mm; and analytical flow cell (1), 5-mm (2) 32X HPLC Pumping System 307 Isocratic HPLC Pump: 5-mL pump head UniPoint System Software March 2005 Page 1 of 5 319327-01

Accessories and Reagents Columns Ion-exchange: AX300 250 x 4.6 mm, 6 micron Trap reverse-phase: (5) Aquasil C-18 30 x 4.6 mm, 3 micron Reverse-phase: Beta Basic C-18 100 x 4.6 mm, 3 micron Mobile Phase (ion-exchange) (A) 20 mm tris acetate, ph 7.8 (B) 20 mm tris acetate, 100 mm sodium acetate Gradient: 0 50% B in 25 minutes, 50% B from 25 27 minutes Mobile Phase (reverse-phase) (A) water, 0.1% TFA (B) ACN, 0.1% TFA Gradient: 0 100% B in 12 minutes, 100% B from 12 14 minutes Natural Products Evaluated Mugwort (black sage): methanol/water extracts, 100 mg/ml of plant was extracted. Figure 1. 2-D System illustration. Figure 2. Schematic of 2-D System plumbing. March 2005 Page 2 of 5 319327-01

Methodology Mugwort (black sage) ground plant (flowers, leaves, stems) was extracted with water and methanol. The extracts were filtered with a 0.45-µm filter. The aqueous and organic extracts were injected onto the ion exchange column. The injection volume was 500 µl to overload the column. The sample was eluted through the ion exchange column. The column eluent prior to the detector was mixed with a constant volume (0.35 ml/min) of water from a dilution pump. The eluent was trapped onto small reverse-phase columns (5) post detector at timed intervals. The trapped RP columns were then switched on line to an analytical reverse-phase column, and the components were separated and fractions were collected. Fractions could then be analyzed via MS or other methods for biological activity. Bidirectional System Control The two HPLC systems are controlled through actions written to the display of the 215 Liquid Handler (e.g., ready, busy ). Two operations lists are run independently of each other to maintain sample and fraction tracking in unique data files. This allows each system to complete their application without delay and employ one 215 Liquid Handler for both systems to minimize required bench space. Collected fractions are then analyzed via selective methods (e.g., MS analysis). Results (a) Time (min) Figure 3. Ion exchange chromatograms from mugwort extractions using (a) water and methanol. Spikes represent switching between the trapping columns. Column was exposed to an excess of sample for collection and post-run evaluation. March 2005 Page 3 of 5 319327-01

(a) Time (min) Figure 4. Overlays of the reverse-phase chromatograms from the trapped columns; trap 1 5, top to bottom. (a) Water extract traps and methanol extract traps. Each column was switched in line with the reverse-phase analytical column and run under basic RP conditions. Fractions were collected via time for each run into microplates. Specific fractions were then analyzed via MS. (a) (c) (d) Figure 5. Mass spectral data taken on specific fractions from the methanol extract. Evaluation of the data was based on a published database for mugwort: ARS Phytochemical and Ethnobotanical (permission for use granted by Dr. Duke). Although additional evaluations and studies would need to be done to confirm all structural determinations, possibilities are offered as follows: (a) carotene-type compound, coumarin/cineole, (c) coumarin (d) plant steroid-type compound. March 2005 Page 4 of 5 319327-01

Conclusion 2-D HPLC as presented in this application offers separation advantages for complex components such as natural products (e.g., Mugwort). Complex constituents found in natural products require tandem separation techniques which are manually challenging. The use of 2-D automated HPLC in this perspective allows for a significant amount of the natural product to be loaded onto the ion exchange column in order to circumvent the requirement for a significant initial separation which will require adjustments for each natural product evaluated. Employing small RP columns to trap the eluent, in conjunction with the dilution pump, reduces the salt concentration, eliminating the concern that the sample will precipitate ( salt out ) under RP conditions. Retaining the compounds from the initial ion exchange onto the small trap columns simplifies the 2-D reverse-phase chromatography. Extremely reproducible fractionation of the secondary RP separation deliver the components in an acceptable state for mass spectral evaluation. Having the entire process automated on one bed layout eliminates confusion with sample transfer and sample and fraction tracking. The entire process is controlled through the software, and sample and fraction tracking data are identified and can be placed in discrete folders for future evaluation. Automation of 2-D HPLC offers a degree of consistency and throughput that enhances the process and evaluation of the components to be determined. Gilson, Inc. World Headquarters P.O. Box 620027, Middleton, WI 53562-0027 USA Telephone: (1) 800-445-7661 or (1) 608-836-1551 Fax: (1) 608-831-4451 Gilson S.A.S. 19, avenue des Entrepreneurs, F-95400 VILLIERS LE BEL France Telephone: (33-1) 34 29 50 00 Fax: (33-1) 34 29 50 20 www.gilson.com sales@gilson.com, service@gilson.com, training@gilson.com March 2005 Page 5 of 5 319327-01