Sign & Post Installation. Standard Specifications and Standard Drawings. July 2017 Edition

Similar documents
CITY OF FARGO SPECIFICATIONS SIGNING

CITY OF SANTA ANA PROPOSAL PROJECT NO.: CHESTNUT AVE & BUSH/CYPRESS BIKE LANES FAID#: U58DP005861

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

CHAIN LINK FENCES AND GATES

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Section 13. Guidelines for the Design of Ground Mounted Sign Supports

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

PLATFORMS. Aluminum Platforms

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

1 1 4" FRAMING SYSTEM

SECTION PLATE CONNECTED WOOD TRUSSES

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

Section 906. STRUCTURAL STEEL

1470 Dale Court Austell, GA Phone: Fax:

DIVISION 1100 TRAFFIC

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

TEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Section 2 Supplemental Specification 2.11 High Tension Cable Barrier

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Code Compliance Research Report CCRR-0194

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Cantilevered Rail System

PUBLIC WORKS SKAGIT COUNTY SAMISH ISLAND ROAD SAMISH ISLAND ROAD SLIDE REPAIR

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Fig Beam Clamp Retaining Strap (B-Line B3367)

SECTION CLIMBING WALLS

ALSPEC ALUMINIUM SYSTEMS TECHNICAL MANUAL

PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

POST FRAME BUILDING STANDARDS

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION 1043 FENCE MATERIAL

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

A. Access doors and frames are part of an access door and frame allowance.

ROLLING RACK. Simple Security

SECTION ALUMINUM BLEACHER SYSTEM (NEW SCHOOLS/REPLACEMENT AT EXISTING SCHOOLS)

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

Fig. 1 - Standard Clevis Hanger

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

TRANSPORT II " 10.5" MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING

Model # 338S-OP. 9/30/2011 Page 1 of 13

Smarter. Safer. Leaner.

SECTION MASONRY ACCESSORIES

The advantages of resistance welding versus Mig welding are: Weld consistency Weld strength Floor cleanliness.

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019

Model # 158-P4. 12/12/2013 Page 1 of 11

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Architectural Specifications, Section Phenolic Lockers

40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Seismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION ALUMINUM GATES

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

ROOF MOUNT KIT OWNERS MANUAL

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SPECIFICATION FOR REINFORCED SOIL WALL

Single & Back-to-Back StiffWall Column Product Profile

SECTION ORNAMENTAL HANDRAILS AND RAILINGS

American Metal Specialties, Inc.

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

SECTION IMPACT RESISTANT WALL PROTECTION

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION I -- IRONWORK

Planning and installation instructions

Note: Above dimensions will vary due to manufacturer s tolerances. Metric sizes also available.

UTILUX CABLE MANAGEMENT

SECTION SLUICE GATES

PIPE AND TUBE RAILINGS

DIVISION 33 - UTILITIES SECTION UTILITY PIPE BORING AND JACKING DIVISION 33 UTILITIES SECTION UTILITY PIPE BORING AND JACKING

GroundTrac. Installation Manual

SECTION ALUMINUM RAILINGS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

Code Compliance Research Report CCRR-0213

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

Model # 358H-PR. 4/8/2011 Page 1 of 12

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

Pick Smarter. Pick Better. Pick UNEX. MODULAR FLOW-THROUGH WORK STATIONS FOR ASSEMBLY AND LINESIDE STORAGE

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

SECTION ACOUSTICAL PANEL CEILINGS

Box Rail. Single Box Rail Bracket

SPECIFICATION FOR THE RUBBER SPEED HUMPS

Ultra Aluminum Fence, Rail & Gate Specifications

16. Design of Pipeline Structures.

Transcription:

Standard Specifications Sign & Post Installation Utility Services Department 500 George Street North, Peterborough, Ontario, K9H 3R9 Transportation Division Telephone: 705-742-7771 Fax: 705-876-4621 Sign & Post Installation Standard Specifications and Standard Drawings. July 2017 Edition

2 TABLE OF CONTENTS NUMBER TITLE PAGE TABLE OF CONTENTS 2 INDEX OF STANDARD DRAWINGS 3 CP4000.00 SUPPLY / INSTALL NEW TRAFFIC SIGNS & POSTS 4 CP4000.01 REMOVAL AND SALVAGE OF EXISTING TRAFFIC SIGNS 6 CP4000.02 SUPPLY AND INSTALL OVERSIZED STREET NAME SIGNS 6

INDEX OF STANDARD DRAWINGS 3 USDTR 5000.07 USDTR 5000.08 USDTR 5000.09 USDTR 5000 10 USDTR 5000.11 USDTR 5000.12 USDTR 5000.13 USDTR 5000.14 USDTR 5000.15 USDTR 5000.16 USDTR 5000.17 USDTR 5000.18 Typical Sign for hazard marker/keep Right Signs Typical Bicycle Lane Typical Parking Signage Installation/Location Detail Typical School Crossing Signs in Vicinity of Sidewalks Typical School Crossing Ahead and School Area Typical Sign Installation/Location Detail Typical Regulatory and Street Name Signs Installation/Location Detail Typical 100mm X 100mm Pressure Treated Post Installation/Location Detail Typical Oversized Street Name Sign Mounting Detail Typical Sign Installation/Location Detail Typical Sign Installation/Location Detail for Traffic Signal Ahead & NEW Sign for Signal Control Typical 911 Address Sign Installation/Location Detail City of Peterborough Traffic Sign Sheeting Specifications 2014.

4 CP4000.00 SUPPLY / INSTALL NEW TRAFFIC SIGNS & POSTS The unit price identified in the schedule of unit prices shall be full compensation for all labour, equipment and material necessary to supply and install new traffic signs and posts as shown on the contract drawings. All signs shall be supplied in accordance with the Ontario Traffic Manuals & City of Peterborough Traffic Sign Sheeting Specifications 2014. Posts shall be heavy duty, galvanized U-channel posts, except when placed in asphalt or concrete, where posts shall be Unistrut Telepar galvanized posts with sleeve. All signs and posts shall be installed in accordance with City of Peterborough Standard Specifications and Drawings. The typical location of posts in boulevards shall be 1.0 metre behind the curb and the sign shall be installed at a minimum height of 2.1 metres to the bottom of the sign. All U-Channels and Wooden Posts must be installed as a single uniform post. Specifications: 6 X 6 Wooden Pressure Treated Post Length: Varies Thickness: Width: 5½ inches 5½ inches 4 X 4 Wooden Pressure Treated Post Width: Thickness: Length: 3½ inches 3½ inches Varies Unistrut Telepar Galvanized Posts with Sleeve Galvanized Steel 4 sided perforated 14 Gauges Main Post 1-3/4 x 1-3/4 (Cut to length) Anchor Post 2 x 2 x 3 Sleeve 2-1/4 x 2-1/4 (Cut to length) U-Channel Post

5 U-Channel *flanged* rolled and formed Hot Dip Galvanized per ASTM 123 Minimum Yield strength 80,000 psi Minimum Tensile strength 117,000 psi Minimum weight 2.47 lbs / ft Holes punched 50mm on centre, 25 mm from top of post to approx 1.5 m down Bottom holes punched to attach stabilizer plate. Tapered Drive point Mounting Hardware Kit for Steel Posts (All Hardware to be minimum Grade 5) 2-3/8 X16X2 Stainless Steel bolts 2-3/8 Stainless Steel washers 2 3/8 Stainless Steel lock washers 2 3/8 x1 Nylon washers 2 1 x3/4 Cast aluminium Post Filler Block 2 3/8 X16 Stainless Steel Hex Nuts Banding Materials for Poles 1/2 inch x 0.030 Stainless Steel Banding / Strapping. 1425 lbs Tensile Strength. 1/2 inch Stainless Steel Banding Buckles. Flared Leg Stainless Steel Bracket Additional Hardware for Street Name Signs Criss Cross for Two ¼ Extruded (4)-Set Screw 5/16 18-1/2 Post Cap 1/8 Flat Sign 2 3/8 O.D. (6)-Set Screw 5/16 18-1/2 Circular Support Post Cap Adapter 2 ¼ O.D. Signs are to be manufactured in accordance with MUTCD, OTM Standards & City of Peterborough Traffic Sign Sheeting Specifications 2014. Traffic Signs to be 16 gauge galvanized steel unless specified under Special Provisions of the contract documents. Street Name Sign blades shall be 6 1/4" high constructed of 0.125 aluminum with Engineering Grade Sheeting 3290 Reflective White lettering on 3437 3M Prismatic Green background, 4" upper/lower case CG Triumvirate Bold. No border or holes are required. Non-standard signs shall be detailed under Special Provisions of the contract documents. Reference: USDTR 5000.07 Typical Sign for Hazard Marker/Keep Right Signs

6 USDTR 5000.08 Typical Bicycle Lane USDTR 5000.09 Typical Parking Signage Installation/Location Detail USDTR 5000.10 Typical School Crossing Signs in Vicinity of Sidewalks USDTR 5000.11 Typical School Crossing Ahead and School Area USDTR 5000.12 Typical Sign Installation/Location Detail USDTR 5000.13 Typical Regulatory and Street Name Signs Installation/Location Detail USDTR 5000.14 Typical 100mm X 100mm Pressure Treated Post Installation/Location Detail USDTR 5000.15 Typical Oversized Street Name Sign Mounting Detail USDTR 5000.16 Typical Sign Installation/Location Detail USDTR 5000.17 Typical Sign Installation/Location Detail for Traffic Signal Ahead & NEW Sign for Signal Control USDTR 5000.18 Typical 911 Address Sign Installation/Location Detail City of Peterborough Traffic Sign Sheeting Specifications 2014 CP4000.01 REMOVE & SALVAGE EXISTING TRAFFIC SIGNS & POSTS The unit price identified in the schedule of unit prices shall be full compensation for all labour and equipment to remove and salvage all traffic signs, posts and hardware as shown on the contract drawings. All signs, posts and hardware removed to be delivered to 200 Townsend St. on the same day as removal. Materials are to be removed in a manner in which no damage will occur during the removal process. Any traffic signs that are to be removed that could pose a safety hazard to the public (ie. Stop signs, Yield signs, etc.) must be replaced with a temporary signs for the duration of the project. The Contractor is responsible to maintain these signs until permanent signs are installed. CP4000.02 SUPPLY AND INSTALL OVERSIZED STREET NAME SIGNS The unit price identified in the schedule of unit prices shall be full compensation to supply and install oversize street name signs as shown on the Contract Drawings in accordance with USDTR-5000.15. Unit price bid shall include but not limited to all brackets, hangers and fasteners necessary to install signs on overhead traffic signal arms. Mounting hardware shall be the Sentinel Universal Mounting Bracket. The extrusion is to be 1.2 meters to 1.8 meters feet long depending on the length of the sign. Signs greater than 2.1 meters in length require a 1.8 meter extrusion. The sign blade shall be 16" high constructed of 0.125 aluminum with Engineering Grade Sheeting 3290 Reflective White lettering on 3437 3M Prismatic Green background, 10"

7 upper/lower case CG Triumvirate Bold with 5 lettering for street abbreviation. No border or holes are required. Example: Lansdowne St. Reference: USDTR-5000.15