Underground Exhaust System

Similar documents
ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

SECTION UTILITY MANHOLES AND STRUCTURES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

4 EXTREME FOUNDATION PANELS

SITE WORK II: Footings, Cisterns

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

INDEX FOR SPECIFICATIONS FOR REMOVING CULVERTS AND PLACING CULVERTS SCOPE... 1

POST FRAME BUILDING STANDARDS

SECTION PIPE & PIPE FITTINGS PART 1 GENERAL

CHAPTER 11 CONDUITS AND FITTINGS

Fabrication and Installation Table of Contents

SECTION DUCTILE IRON FITTINGS. A. This section includes materials, installation, and testing of ductile iron fittings 48 inches and smaller.

SECTION HVAC DUCTS AND CASINGS

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

CONDUITS AND FITTINGS

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

4 EXTREME FOUNDATION PANELS

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

B-500 / B-600 SERIES

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

SPECIFICATION FOR REINFORCED SOIL WALL

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

A Design Review of Waterproofing Codes

SECTION FACILITY SANITARY SEWERS

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)

When I started tiling, we didn t do our own shower pans that BATHS

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

FLOOR AND AREA DRAINS

ROLLING RACK. Simple Security

B R OA DWAY RAC K. High Security

ZS880 Linear Shower Drain Installation Instructions

A. BILL OF QUANTITIES FOR SANITARY SEWER

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

BioPrism Solid Surface

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

Foundation instruction manual. 99 ft² (9,2m²)Grillkota

Storm Drainage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

Design & Construction Standards, Revised January

SPECIFICATIONS FOR POLYVINYL COATED UNDERGROUND DUCT SYSTEMS & FUME EXHAUST SYSTEMS

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

Attachment A-Flagpole(s) Specifications

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

TILE TILE

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Zurn Z886. 6" Perma-Trench. Installation Instructions

Underground Piping for Private Hydrants & Sprinkler Supply Line

Welcome: What is U-Drain? Drain Materials. Flow

Installation Information 2016

SECTION WATER DISTRIBUTION

Diffused Aeration Piping Equipment

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Flygt Advanced Low Pressure Sewer System Package

STANDARD SPECIFICATIONS SECTION JACKED CASING

FORMDECK. constructions. constructions

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

INSPECTION GUIDELINES: JOIST AND UNDERFLOOR COMBO

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Guidelines to installing the ACO Sport range of products

Sample Specification

INDUSTRIALIZED CONSTRUCTION BRASILIT FIBER CEMENT BOARD, PANELS AND ACCESSORIES FOR THE EXECUTION OF YOUR CONSTRUCTION

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

Luka Quality Assurance Manual (Eng)

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours

11. Construction processes and materials Power House Maintenance Building Fuel Treatment Building...

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

***************************************************************************************************************

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION TURBINE VENTILATORS

American Metal Specialties, Inc.

Douglas County Traffic Signal Installation Guidelines (January 2013)

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 811 CONDUIT AND DRAINAGE STRUCTURES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

SECTION A1 EXCAVATION AND BACKFILL GENERAL

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

WIRING METHODS CHAPTER 38

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Summary of the 2011 Changes

Foundation/Site Work Code Requirements

SPECIFICATION GUIDELINE

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

Uwall UNIVERSAL CONSTRUCTION MANUAL

Section 2: Underground

Installation Instructions

C. Foundation stabilization for pipe and utility structures.

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

TYPICAL INSTALLATION INSTRUCTIONS

Transcription:

Operation and Maintenance Manual Underground Exhaust MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015

Underground Duct Construction Standards 1. Dig trench depth to allow for minimum distance from the top of the pipe of 11 to finished floor, to a maximum distance from the top of the piece of pipe of 17 to finished floor. (The saddle body is adjustable. The saddle tube has a clamp band attached to hold outlet to saddle.) In some cases the saddle may not be adjustable. In this instance, the trench depth will be the distance from the bottom of the pipe to the floor flange. 2. Install pipe and fittings according to local codes and industry standards. Use proper sealant at all joints. If joints utilize angle rings use appropriate sealant or closed cell gasket material. 3. Pipe and fittings should be pitched, in the direction of airflow, back to a sump or pit where the pipe emerges from underground. Consult local codes for any special requirements. 4. Following the building plan, locate and mark location for each floor outlet assembly. 5. Cut hole in pipe. Hole to be slightly larger than the opening in the saddle tap. Remove any burrs or rough edges that may come in contact with flex hose assembly. 6. Center saddle over hole and fasten pipe making sure that the saddle is inclined in the proper direction. It is recommended that the saddles be attached to the pipe with full circle clamps on each end. Screws or rivets that protrude in to the pipe may catch on the flex hose assembly causing damage to the hose and/or making hose storage difficult. Use appropriate joint sealant to seal saddles to main duct. 7. Back fill around pipe and saddle assembly. Consult local codes for any special requirements. 8. Adjust floor flange to proper level. Position and/or support using wooden stakes if necessary. 9. You are now ready to pour the finished floor. Care must be taken so as not to disturb floor outlets while pouring and finishing the floor. (For example, don t allow them to be run over with the cement truck or wheelbarrows.) info@ 1

Underground Duct Construction Standards S3.41 This installation standard is applicable to ducts placed in or beneath concrete floors or in areas free from vehicle traffic. S3.42 Materials shall conform to the project specifications. S3.43 Ducts shall be located as shown on the contract drawings. S3.44 The duct contractor shall provide: a) Proper assembly of the duct, including connections and sealing as prescribed; b) Verification of the undamaged condition of the duct before enclosure with fill or encasement. c) Anchorage for the duct, if any. d) Notices of requirements for successive placements of fill, if any. e) Precautions against use of powered vibrators in placing concrete on or around ducts. f) Witnessing of backfill or encasement. g) Temporary protection of openings in ducts. info@ 2

info@ 3

info@ 4

Commentary Materials commonly used for this application include; galvanized steel, vinyl chloride-coated steel, and stainless steel. Glass fiber-reinforced resin, asbestos, cement, tile, and other nonmetal ducts are also used. Ducts are not generally deemed to be or required to be waterproof. Ducts should always be above the water table. The designer should carefully evaluate the exposure to moisture or round water and require vapor barriers, sumps, porous fill, and subsoil drainage pipe as necessary. CSI Specification 02410 provides useful references for subsoil damage. The top of drain tile should be below the bottom of the duct. Corrosion resistance is an important characteristic of both in-slab and under-slab ducts. The Portland Cement Association has guidelines for protection of metals in contact with concrete. ASHRAE's s Handbook addresses the corrosion of materials in soil environments. The strength of round ducts makes them the preferred shape for underground application. Round duct wall thicknesses in these standards are generally acceptable for below-grade installation. Ribbed or corrugated styles have additional crushing strength. Temporary internal supports can be appropriate at times. Ducts should have continuous bedding. Ducts to be embedded in concrete are subject to floating and they must be restrained. The first pour should be the base support for the duct and anchors should be included. Twelve gage (2.68mm) wire, 16gage (2.75mm) straps, or other appropriate ties should be specified for hold-down. Ducts buried in sand or pea gravel are not known to float. Porous fill and earth fill should not be dumped directly on ducts in trenches. Fill should be firmly but not heavily tamped under and around the duct. The first foot of fill should be shovelled on top of the duct. Fill should not contain stones larger than 2" (51mm). info@ 5

MODELS: 23816 - FOR 3 HOSE; 23818 - FOR DUAL 3 HOSE; 23817 - FOR 4 HOSE; 23819 - FOR 5 HOSE; 23820 - FOR 6 HOSE SIDE VIEW * LAY FLAT DOOR & FLOOR FLANGE Concrete ***11" 17" Body Floor Saddle Air Flow Main Duct - Pitch 1" in 40' NOTES: 1. This dimension can be increased or decreased 2. Extension sleeves will be required to reach heights over 17". TOP VIEW 13.5" Main Duct 10.5" 1/4" Door PRODUCT FEATURES: DOOR - 1/4, 4-way Structural Solid Steel Plate - 9 x 11 Zinc Coated FLOOR FLANGE - 14-Gauge Stamped Steel Plate Zinc Coated BODY - SADDLE - 20-Gauge 304 Stainless Steel 20-Gauge 304 Stainless Steel info@ 6