NOBURST. NOBURST Antifreeze & Heat Transfer Fluid Factory Pre-mixed Freeze Protection for Water-based Heating and Cooling Systems

Similar documents
NOBURST. NOBURST Antifreeze & Heat Transfer Fluid Factory Pre-mixed Freeze Protection for Water-based Heating and Cooling Systems

This Technical Note is to notify you that Tecvalco has changed the brand of glycol in the CWT Heater. This change took affect in April 2016.

Dynalene Ethylene Glycol Series

Havoline Antifreeze Coolant

Low Temperature Heat Transfer Fluids

Glysofor TERRA - Specification

Low-Temperature Heat Transfer Fluids Newer Options

Water Quality Specification for Power Supplies

MATERIAL SAFETY DATA SHEET FILE NO.: Instant Brass & Copper Tarnish Remover MSDS DATE: 9/15/2011

ALL SAFE SOLVENT-FREE METAL & PARTS WASHING COMPOUND

Havoline XLC. Product information. 1 Description. 2 Benefits

SAFETY DATA SHEET 46V PAG OIL WITH UV DYE

Water Treatment Program. Training Manual

Dow Oil and Gas. NORKOOL Cleaner, Degreaser and Inhibitor 244 System Maintenance Solutions

SAFETY DATA SHEET Keratin Complex Smoothing Therapy ADVANCED GLYCOLIC HAIR TREATMENT

MATERIAL SAFETY DATA SHEET

green safe efficient Your refrigerant for sustainable chilling and freezing:

Dye and Perfume Free Synthetic Machining and Grinding Fluid

INDUSTRIAL & MANUFACTURING

Version 2 Revision Date 03/04/2013 Print Date 03/07/2013

Safety Data Sheet (SDS) Revision / Review Date: 1/19/15

SAFETY DATA SHEET Keratin Complex Blondeshell Masque

PHOSPHATE FREE TSP REPLACEMENT G-MAX 302 Emergency Phone Material Safety Data Sheet

Material Safety Data Sheet Product No , Cutting Fluid, Soluble Oil Issue Date ( ) Review Date ( )

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

Safety Data Sheet (ASTM D1193 TYPE IV WATER)

*MATERIAL SAFETY DATA SHEET*

Common Name: RECIP LUBRICANT MINERAL OIL Manufacturer: SPEEDAIRE MSDS Revision Date: 7/1/2007 MSDS Format: ANSI-OSHA P14115A

Radiator Maintenance

DRILLING AND TAPPING COMPOUND

Material Safety Data Sheet

BON AMI POWER FOAM GLASS CLEANER

DOW CORNING CORPORATION Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

West Michigan s Factory Representative

Safety Data Sheet Page 1 of 6 Black Flag Fly Window Traps Revision date: 2/17/2016

SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: HAZARDS IDENTIFICATION PRODUCT

Material Safety Data Sheet

Material Safety Data Sheet This MSDS is prepared in accordance with OSHA 29 CFR

MATERIAL SAFETY DATA SHEET. Polypropylene

DRANO DUAL FORCE FOAMER CLOG REMOVER

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET DISTILLED WITCH HAZEL 14% NATURAL GRAIN ALCOHOL

Material Safety Data Sheet

Copper Corrosion Control

Material Safety Data Sheet

Material Safety Data Sheet

Please take the time to complete the attached questionnaire and return the completed survey within thirty (30) days of receipt.

MATERIAL SAFETY DATA SHEET

6.1 Introduction to Wastewater Issues

MATERIAL SAFETY DATA SHEET For Freezol Water based fire extinguisher anti-freezing agent

0 50 Very soft Soft Medium Hard

University of Houston Master Construction Specifications Insert Project Name SECTION WATER TREATMENT SYSTEMS PART 1 - GENERAL

Page 1 / 6 Safety Data Sheet. Lubricating Grease. Issuing Date Revision Date Version 1

1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND THE COMPANY DWS/LF/100, DWS/LF/250 & DWS/LF/500

SAFETY DATA SHEET. Veteran Miracle Finish. DISTRIBUTOR 24 HR. EMERGENCY TELEPHONE NUMBERS Cavalier Inc.

WHITE PAPER. Water Quality. Management for the Plastics Industry. Benefit from Improved. Water Quality. Management.

DOW CORNING CORPORATION Material Safety Data Sheet

Version 4 Revision Date 09/27/2013 Print Date 09/27/2013

MATERIAL SAFETY DATA SHEET MSDS #: 166 BLACK LIQUOR SOAP 1. PRODUCT AND COMPANY IDENTIFICATION

INTERCOOL BIOGREENHeat Transfer Fluids. Renewably Sourced Susterra 1,3-Propanediol

Name Product identifier % GHS-US classification

Material Safety Data Sheet

Gilette Environment Health and Safety

Trend Machinery & Cutting Tools Ltd

Material Safety Data Sheet Version: 1.5 Revision Date: 2012/06/19 1. PRODUCT IDENTIFICATION

DOW CORNING CORPORATION Material Safety Data Sheet

Material Safety Data Sheet (MSDS)

MATERIAL SAFETY DATA SHEET

Material Safety Data Sheet

Solid Ink - Black, Cyan, Magenta, Yellow

MO TITRANT M SAFETY DATA SHEET. 1. Product and Company Identification. 2. Hazards Identification. 3. Composition / Information on Ingredients

Products for Welding Liquids, sprays and doughs

Material Safety Data Sheet Flash Rust Inhibitor MB Section 1. Chemical Product and Company Identification

The Thermal Bath Fluids

SAFETY DATA SHEET. 1. Product and Company Identification. Product Name : DIRTEX SPRAY Product Code : 760N Recommended Use: Cleaner

Material Safety Data Sheet

POTASSIUM BICARBONATE

Material Safety Data Sheet. Accepta Statham House Talbot Road Manchester M32 0FP

SAFETY DATA SHEET 16 Sections

DOW CORNING CORPORATION Material Safety Data Sheet

2015 UPC Chapter 6 Water Systems Part 1 RV

SAFETY DATA SHEET. Robelle Industries 3-Month Algaecide. Page 1 of 5 1. PRODUCT AND COMPANY IDENTIFICATION

DOW CORNING CORPORATION Material Safety Data Sheet MOLYKOTE(R) 55 O-RING GREASE

Galvanic Corrosion Prevention Guide for Water Cooling Systems

SUPER WHITE FONOLINE Petrolatum. Sonneborn, Inc. 771 Old Saw Mill River Road Tarrytown, NY , USA

Scott s Liquid Gold Wood Cleaner & Preservative (Aerosol) or consult local poison control center immediately

SAFETY DATA SHEET Pump Flush

MATERIAL SAFETY DATA SHEET

RHOPLEX WL-96 Waterborne Acrylic Polymer For Low VOC Interior Clear Wood Finishes

SAFETY DATA SHEET. Step and Shine Concentrate

Paints and Coatings Industry Cleaning products for all paint systems. For a perfect surface

Product Health & Safety Data

#287 FOOD GRADE FLUSHING AGENT

MATERIAL SAFETY DATA SHEET

Page : 1 MATERIAL SAFETY DATA SHEET Version : 1 OCTAVE SECTION 1 IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING

Material Safety Data Sheet

Material Safety Data Sheet

Material Safety Data Sheet

Transcription:

Antifreeze & Heat Transfer Fluid Factory Pre-mixed Freeze Protection for Water-based Heating and Cooling Systems non-toxic Q antifreeze solutions are to be used in place of water and other water-like fluids in systems where freezing may either cause damage or interfere with the functioning of systems or equipment and/or toxicity to humans or animals is a concern. 1 Simple Solutions... Proven Performance AMERICAN COMPANY AMERICAN PRODUCTS VIEW PRODUCT DETAILS AND DIAGRAMS ONLINE

ANTIFREEZE AND HEAT TRANSFER FLUID non-toxic antifreeze solutions are factory pre-mixed freeze protection for water-based heating and cooling systems to be used in place of water and other water-like fluids in systems where freezing may either cause damage or interfere with the functioning of systems or equipment, and/or toxicity to humans or animals is a concern. family of products consists of ALL-NEW RTU40 PG, RTU35 35% PG, and RTU30 30% PG, plus -100, Super, HD, and AL. AVAILABLE SIZES 5-gallon pails 30-gallon drums 55-gallon drums 275 or 330-gallon totes 5,000-gallon tank truck AVAILABILITY Noburst Ready to Use mixes are available throughout the U.S. through wholesale distributors. Please contact Noble Company for your local representative and wholesaler. CUSTOM BLENDS Custom formulations are available for lower concentrations of glycerine.please contact Noble Company for more information. INGREDIENTS Active: Propylene Glycol and Dipotassium Phosphate Other: Viscosity Reduction Agent, Food-Grade Dye, Deionized Water 24

NEW! READY TO USE Water quality concerns are no longer limited to our drinking water. Whether it s well or municipal water with high total hardness, boiler equipment manufacturers are now more cautious than ever. When mixing propylene glycol on-site, poor water quality can lead to long-term damage to heating systems. Noble Company is addressing those concerns and is pleased to introduce a new line of ready-to-use antifreeze that eliminates these water quality concerns. Designed to be introduced directly into systems with no on-site dilution, RTU products are factory premixed with deionized water ensuring no mineral content or hardness levels and the elimination of chlorides, which are second only to oxygen as a leading cause of heating system corrosion. RTU blends are available in 30, 35, and propylene glycol concentrations with no minimum order quantity. DO NOT DILUTE. RTU40 PG Boiling Point 103.9 Viscosity @ 160 F 1.04 Specific Gravity @ 72 F 1.027 Thermal Conductivity @ 160 F 0.24 Specific Heat Capacity @ 160 F 0.925 RTU 35 35% PG Boiling Point 102.8 Viscosity @ 160 F 0.93 Specific Gravity @ 72 F 1.024 Thermal Conductivity @ 160 F 0.255 Specific Heat Capacity @ 160 F 0.939 RTU30 30% PG Boiling Point 102.2 FREEZE 35% 30% -6 F 0 F 11 F Viscosity @ 160 F 0.82 Specific Gravity @ 72 F 1.021 Thermal Conductivity @ 160 F 0.271 Specific Heat Capacity @ 160 F 0.953 FLOW BURST 35% 30% 35% 30% -16 F -10 F 2 F -8 F > SYSTEM PROTECTION Freeze Point is the temperature where the first ice crystal forms in the fluid. Burst point is the temperature where the fluid is solid, expanding, and bursting the vessel. *Specific gravity measured at 72 F. **Viscosity, specific heat capacity, and thermal conductivity are measured at 160 F. 3

-100 Non-toxic Non-corrosive High efficiency Blended with deionized water -100 is to be used in place of water and other water-like fluids in systems where freezing may either cause damage or interfere with the functioning of systems or equipment and/or toxicity to humans or animals is a concern. This product must NOT be used in automotive cooling systems or with galvanized metals containing zinc or aluminum. FREEZE 0 F -30 F Boiling Point 238 224 218 Viscosity @ 160 F 2.19 1.43 0.93 FLOW BURST -10 F -40 F -80 F Specific Gravity @ 72 F Thermal Conductivity @ 160 F Specific Heat Capacity @ 160 F 1.055 1.046 1.035 0.161 0.205 0.256 0.806 0.890 0.939 SUPER Concentrated formula Non-toxic Non-corrosive High efficiency SUPER is for hydronic boilers and solar systems. With proper installation and annual inspection, it will protect systems from freeze damage and severe corrosion for 10 years. This product must NOT be used in automotive cooling systems or with galvanized metals containing zinc or aluminum. FREEZE FLOW BURST -20 F 0 F -30 F -10 F > -80 F Boiling Point 310 237 222 219 Viscosity @ 160 F 4.13 2.30 1.29 1.00 Specific Gravity @ 72 F Thermal Conductivity @ 160 F Specific Heat Capacity @ 160 F 1.052 1.054 1.044 1.031 0.126 0.157 0.217 0.251 0.696 0.797 0.898 0.929 44

AL Use with all metals Non-corrosive Special inhibitor package High efficiency Blended with deionized water An antifreeze and heat transfer fluid for systems which contain aluminum components. AL has inhibitor technology that is compatible with all metals commonly used in hydronic heating systems including brass, cast iron, steel, solder, copper, and aluminum. This product must NOT be used in automotive cooling systems or with galvanized metals containing zinc or aluminum. 1 AL is not to be used in contact with or potential contact with potable water. FREEZE 0 F -30 F Boiling Point 238 224 218 Viscosity @ 160 F 2.19 1.43 0.93 FLOW BURST -10 F -40 F -80 F Specific Gravity @ 72 F Thermal Conductivity @ 160 F Specific Heat Capacity @ 160 F 1.055 1.046 1.035 0.161 0.205 0.256 0.806 0.890 0.939 HD Extended temperature range Non-toxic Non-corrosive High efficiency Blended with deionized water HD is a non-toxic* antifreeze and heat transfer fluid with a special inhibitor package allowing for use where system temperatures demand glycol stability. Safe for use up to 325 F. Does not contain silicone-based additives, which can harm systems at high temperatures. This product must NOT be used in automotive cooling systems or with galvanized metals containing zinc or aluminum. FREEZE FLOW BURST 0 F -16 F -10 F -26 F Boiling Point 310 237 222 219 Viscosity @ 160 F 4.13 2.21 1.26 0.99 Specific Gravity @ 72 F Thermal Conductivity @ 160 F Specific Heat Capacity @ 160 F 1.052 1.054 1.044 1.037 0.126 0.160 0.220 0.247 0.696 0.803 0.901 0.932 5

APPLICATIONS SYSTEM TYPE -100 AL Super HD RTU Hydronic heat systems l l l l l Solar heating systems l Geothermal systems Air Hydronic heat pumps l l l l Air Hydronic furnaces l l l Water-based heat extraction systems Cooling systems & chillers l l l l l l l l l l Refrigerating systems l l l l l Cooling towers l l l l l Industrial heat transfer l l l l l Plumbing winterization l l l Snow melt systems l l l l In-floor heating l l l l l HEAT TRANSFER PROPERTIES Relative System Efficency 2 Thermal Conductivity BTU/HR/FT/ F Viscosity (Centipoises) Foam Character Water 1.000 0.35 0.42 None +32 Noburst -100 () 0.930 0.256 0.93 None -60 Noburst -100 () 0.833 0.205 1.43 None -80 Noburst -100 () 0.799 0.161 2.19 None -100 Ethylene Glycol 3 () 0.896 0.237 1.40 Slight -34 Ethylene Glycol 3 () 0.772 0.183 2.75 Slight -60 Ethylene Glycol 3 () 0.693 0.151 5.00 Slight +5 Silicone SlyTherm 444 4 0.351 0.082 9.86 Slight -121 SlyTherm800 4 0.369 0.074 5.00 Slight -40 Synthetic Hydro-Carbon 3 0.475 0.070 11.69 High -40 Therphenyl 6 0.409 0.0677 9.86 Very High -20 Cold Protection Level (F ) 1. Table data obtained from Dow Chemical, Noble Company tests, and competitors product literature. All comparisons (except cold protection level) are at fluid temperatures of +150 F. 2. System efficiency as a function of specific heat and fluid density with no change in fluid flow rate. 3. Data is for DowTherm brand Ethylene Glycol, Trademark and product of the Dow Chemical Company. 4. Slytherm is a Trademark and product of Dow-Corning Corporation. 5. Data is for H-30, a product of Mark Enterprises. 6. Data is for Therminal 66 Modified Terphenyl 6, a product of Monsanto Industrial Chemicals Company. 64

FLUID INSTALLATION NEW SYSTEM EXISTING SYSTEM For AL: Clean by circulating Hydronic System Cleaner Empty/flush fluid Add product or water until desired freeze temp is obtained Install into system and circulate Purge excess air from system Pull sample from system and test for ph and proper freeze temperature For -100, Super, HD, and RTU: Clean by circulating scale/boiler cleaner If mixture is incorrect Clean by circulating System Pre-Cleaner Empty/flush fluid Test mixture with propylene glycol refractometer If mixture is correct Record test results and date on system tag Empty/flush fluid Fill with clean water, circulate, then empty Test Noburst with a propylene glycol refractometer for proper concentration Mix product with deionized/distilled water to desired freeze temperature (see mix chart on container) FLUID MAINTENANCE Draw a fluid sample If fluid is dark, dirty, or smells acidic Drain the fluid and dispose MAINTENANCE Systems with installed should be tested at least annually for adequate concentration and corrosion inhibitor protection level. If concentration is low, add according to this If fluid is clean Refer to product fluid installation chart FORMULA TO INCREASE CONCENTRATION: Example: 400 Gallon Capacity Desired Use a ph tester to measure the fluid s ph OR send sample to Noble Company for testing If the ph of fluid test below 7.5 ph Drain the fluid and dispose currently in system in a container Step 1: 75 minus 50 = 25 (Desired Current) Step 2: 100 minus 50 = 50 ( Current) Step 3: 400 x 25 = 10,000 (Capacity x {Desired Current}) For AL: If the ph of the fluid tests between 7 ph & 8.0 ph, add AL Inhibitor (ph should be between 8 & 9.0) Test product with a propylene glycol refractometer for desired freeze temperature If mixture is correct Step 4: 10,000 divided by 50 = 200 Conclusion: 200 gallons of -100 must be added to the 200 gallons of solution currently in the system to reach a total solution. Before adding additional, drain adequate fluid from the system so that when the new is added, the operating pressure will not For -100, Super, HD, and RTU: If the ph of the fluid tests between 7 ph & 8.0 ph add Inhibitor Boost (ph should not exceed 12.0) If mixture is incorrect Add product or water until desired freeze temp is obtained Record test results and date on system tag be too high. If the corrosion inhibitor tests low, add one pint of Inhibitor Boost for every 20 gallons of fluid capacity of the system. If the total system capacity is less than 20 gallons, use one pint. If after Inhibitor Boost addition and thorough system mixing the corrosion inhibitor still tests low, add another pint for every 20 gallons system capacity. If after this addition the inhibitor still tests low, the system has been contaminated with minerals or an acidic chemical. The system should be drained, cleaned, and recharged with fresh. 7

SYSTEM MAINTENANCE SYSTEM PRE-CLEANER Removes flux, oil, and grease from new systems, assuring maximum performance. Use one pint for every 50 gallons of system capacity. For use with: -100, Super, HD, RTU INHIBITOR BOOST Regenerates corrosion inhibitors and extends the life of in a system. Use one pint for every 20 gallons of system capacity. For use with: -100, Super, HD, RTU E-3 DEFOAMING AGENT To aid in removing air from the system. Air can cause corrosion, reduce circulation, waste energy, and cause noise. Use one pint for every 25 gallons of system capacity. For use with: -100, Super, RTU ALL METALS INHIBITOR Reduces the rate of corrosion and helps prevent scale formation on heat exchanger surfaces. Safe on all metal systems (including aluminum). Can be used with water only systems. Suitable for use with Onix & Pex tubing used in hydronic installations. Use one gallon for every 50 gallons of system capacity. For use with: AL HYDRONIC SYSTEM CLEANER Penetrates and disperses a broad range of mineral and organic deposits. Helps recover efficiency in older, corroded systems. Cleans aluminum, iron, copper, brass, and stainless steel. Suitable for use with Onix & PEX tubing. Contains no TSP, acids, or heavy metals. Use one gallon for every 50 gallons of system capacity. For use with: -100, Super, HD, AL, RTU

TESTING ACCESSORIES TEST KIT (10 TEST STRIPS) For testing the concentration and reserve alkalinity For determining the actual level of freeze and corrosion protection in a system For use with: -100, Super, and HD, RTU ANALOG REFRACTOMETER For testing the freeze point Use for testing propylene glycol Can be used to test batteries For use with: -100, Super, HD, AL, RTU PALM ABBE DIGITAL REFRACTOMETER Instant results of freezing point (PG & GL) and % concentration by volume Use for testing propylene glycol and glycerine Auto calibration For use with: -100, Super, HD, AL, RTU TESTING To test the freeze protection level of, the correct instrument must be used. FLAMMABILITY: Non-flammable. is not flammable since it has no measurable flashpoint (Pensky-Martens Closed Cup); however, if the product comes in extended contact with open flame, it is possible it will ignite. Material Safety Data Sheets available upon request. FUMES: Non-hazardous. ENVIRONMENTAL HAZARD: Low. is not toxic to animals or plants. Spills may generally be disposed of through city sanitary sewer; however, local sewer authorities should be contacted prior to disposal. Large spills, uncontrolled disposal, and waterway discharge should be avoided since biodegrades rapidly, possibly depleting oxygen supply in bodies of water which can result in fish kill. All uncontrolled spills should be reported to local authorities. Water softeners should be disconnected from the boiler or provided with backflow protection to prevent contamination of the mineral bed.

SYSTEM REQUIREMENTS, LIMITATIONS & CAUTIONS should not be used in systems where temperatures regularly exceed 275 F or in systems that are permanently open to the atmosphere. Use HD in systems where temperatures exceed 275 F, up to 325 F, such as solar hot water systems. Systems constructed of aluminum will also experience corrosion with, particularly if high temperatures (125 F +) are expected. For systems with aluminum, use AL. All other common metals are protected from corrosion with -100, Super, HD, and RTU. products should not be used in systems containing galvanized metal. is not recommended for use with CPVC or PVC. Should not be used in steam-type heating systems. Should not be used as a coolant for internal combustion engines. Although existing systems require no modification, in new systems being designed for use with, the following modifications are recommended: (1) the expansion tank should be sized to allow about 4% greater expansion than for plain water in the same temperature range; (2) the pump head should be increased by 10% over the minimum requirements for those with plain water; and (3) a strainer should be installed in the return line ahead of the pump. A well-maintained hydronic system using should not require other treatment chemicals. should not be used with other water treatment chemicals. Noble Company cannot test all possible combinations of chemicals for compatibility and proper performance. Although is compatible with the leading stop-leak chemicals, we do not recommend the use of these chemicals because of their possible detrimental influence on equipment. TECHNICAL SUPPORT Noble offers technical services for the following: Specifications Field Services Installation Design Fluid Testing Installation Techniques and Unique Applications Address inquiries ATTN: Technical Support, Email: sales@noblecompany.com or phone at: 800-878-5788. Field services are available through factory representatives and Noble Company staff. Contact Noble Company for local representatives. Additional product information and MSDS are available immediately through our website at www.noblecompany.com. Q FDA REFERENCE -100, HD, Super, and RTU are considered Generally Recognized as Safe by the Federal Food & Drug Administration. Non-Toxic is used to describe extremely low chronic and acute toxicity. No maximum safe intake for humans has been established. TOXICOLOGICAL, ENVIRONMENTAL, & HEALTH INFORMATION Gosselin Toxicity Index (Propylene Glycol): 1 essentially nontoxic. Mean Single Lethal (Oral) Dosage: greater than one liter. FDA Reference: Propylene Glycol: 21 CFR 182.1666, Dipotassium Phosphate: 21 CFR 182.6285. Both qualify as Generally Recognized as Safe for use as Direct Food Additives. P.O. Box 350 Grand Haven, MI 49417-0350 800-878-5788 Fax: 231-799-8850 www.noblecompany.com Registered Trademark of Noble Company Trademark of Noble Company, Grand Haven, MI. 2018 Noble Company File #FF122017-14 03/18 Supersedes NB012017-11