Azure cseries. A new way to see the light. c600 c500 c400 c300

Similar documents
Azure Biosystems Western Blotting Workflow

Innovations To Meet Your Needs

Chemiluminescence Detection. Using UVP s ChemiDoc-It System

Flow Cytometry - The Essentials

Optiblot ECL Ultra Detect Kit (1.2pg 2ng)

Blotting and Immunodetection. Multiplex Fluorescent Blot Detection: A Troubleshooting Guide

Radiance. Long Protocol for Catalog Numbers. Chemiluminescent substrate for quantitative chemiluminescent Westerns

Multiplex Fluorescent Western Blot Starter Kit for the Bio- Rad ChemiDoc MP

ChemiDoc Touch Imaging System

Imaging Nucleic Acid Gels on the Odyssey Fc Imager

Dolphin-Chemi Plus. Aim: To visualise and evaluate the performance of chemiluminescent immunoblots using Wealtec s Dolphin-Chemi plus image system

Amersham Western blotting

Western Blotting Detection Reagents

Imaging and Electrophoresis. Gel Doc EZ Imager. Accelerate your research. Push-button imaging in just 10 seconds.

d. Bands hidden by overexposure with chemiluminescence become clear when imaged with Odyssey.

GeneTools the Essential Software For Accurate DNA/RNA Gel and Blot Analysis

Experimental Protocol for Multiplex Fluorescent Blotting Using the ChemiDoc MP Imaging System

Thermo Scientific GENESYS 10S Bio spectrophotometer

A legacy of innovation and discovery

Instant-Bands Protein Sample Loading Buffer for SDS-PAGE. User s Manual. View Protein Bands in an SDS Gel. Instantly. EZBiolab.

GEL IMAGING. The detection and quantitation of specific subsets of posttranslationally

Touchscreen (standalone capabilities, PIN-protected user accounts, and dye calibration/rnasep functionality)

Speed Past the Twists and Turns in Protein Research

EZ-Vision DNA Dye as Loading Buffer

WesternBright Quantum

Lecture 13: Analysis of 2D gels

CF Dyes Next Generation Fluorescent Dyes Secondary antibody

Comparing the Agilent 2100 Bioanalyzer Performance to Traditional DNA Analysis Techniques

TaqPath ProAmp Master Mixes

This Document Contains:

In-Gel Western Detection Using Near-Infrared Fluorescence

Good Westerns Gone Bad:

WANT TO IMPROVE YOUR WESTERN BLOTTING EFFICIENCY? TAKE ADVANTAGE OF OUR GREAT WORKFLOW OFFERS!

and Criterion TGX Stain-Free Precast Gels

hfab Rhodamine Housekeeping Antibodies

GE Healthcare Life Sciences. Laser. epi. trans CCD. epi. Imaging. Principles and Methods

PERFORMANCE MADE EASY REAL-TIME PCR

Direct visualization, sizing and concentration measurement of fluorescently labeled nanoparticles using NTA

In-Cell Western Kits I and II

ab Optiblot Fluorescent Western Blot Kit

Working Reagent Preparation 1:1,000 dilution in standard Alcoholic Ortho- Phosphoric acid staining solution

Laboratory Water Quality Affects Protein Separation by 2D Gel Electrophoresis

ProSignal Dura Juniper Creek Lane, San Diego, CA Phone: Fax:

All-In-One Precast Agarose Gel Electrophoresis Kit (2x9-Well)

QImaging Camera Application Notes Multicolor Immunofluorescence Imaging

Using ULS24 CMOS Bio-imager as a Readout Sensor for Chemiluminescence Immunoassay and DNA Hybridization Assay

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

PSC 4-Marker Immunocytochemistry Kit PSC (OCT4, SSEA4) Immunocytochemistry Kit PSC (SOX2, TRA-1-60) Immunocytochemistry Kit

Sample Quantitation. Spectrophotometry 18. Protein Assays 20. Ordering Information 23

Fluorescent Nanoparticles for Western Blotting

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

special offers from your protein biology resource

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Revolutionary Fluorescence

Notes to accompany the slidecast on theory of SDS PAGE and Western blotting

Integrated Imaging Solutions for Robust and Replicable Data

Staining and Detection

ProSignal Pico Juniper Creek Lane, San Diego, CA Phone: Fax:

Optiblot. Western Blot Reagents and Troubleshooting Tips. Discover more at abcam.com/optiblot

DNA Arrays Affymetrix GeneChip System

Amersham * ECL * Gel horizontal electrophoresis system

Greenhouse Gas Measurement Technology

NovoCyte Flow Cytometer

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

SYBR Green I Nucleic Acid Gel Stain

Extraction of DNA staining dyes from DNA using hydrophobic ionic liquids

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis)

SDS PAGE. Reagents and Equipment. SERVA SDS PAGE Gels. Electrophoresis Buffers, Ready-to-Use. Reagents. Gel Media. SERVA Protein Standards

CyFlow Cube series Appealing from every angle

Agilent s Mx3000P and Mx3005P

Protein Electrophoresis EZ-Run Protein Gel Solution EZ-Run Protein Standards EZ-Run Gel Staining Solution Traditional SDS-PAGE Reagents

Maximize Your Western Blotting Results. Superior products for every step of the Western workflow

Bioinstrumentation Light Sources Lasers or LEDs?

CBI Toolbox Tour 2015

ibox Explorer TM Imaging Microscope

LabChip 90 System with DataViewer Software

Electrophoresis 101 Student Worksheet

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Technical Note Detection of post-immunoprecipitation proteins by Western blot using the Quick Western Kit IRDye 680RD

B-BOX Blue Light LED epi-illuminator. Catalogue No.: VE0100. Operator s Manual Ver

Technical Note. Housekeeping Protein Validation Protocol

Precast Gels. ClearPAGE. SDS PAGE or DNA/Native gels with unsurpassed resolution and 2 year shelf life

KPL LumiGLO Reserve Chemiluminescent Substrate

SmartSpec Plus spectrophotometer

Odyssey Western Blotting Kits LT

SuperSignal West Pico Chemiluminescent Substrate

western blotting Complete, innovative western workflow solutions

CELL HEALTH. reliable cell viability data. instant time savings. PrestoBlue Cell Viability Reagent

Fig1: Melt pool size of LAMP vs. µlamp. The LAMP process s melt pool is x the area of the LAMP s melt pool.

Masayoshi Honda, Jeehae Park, Robert A. Pugh, Taekjip Ha, and Maria Spies

Enzyme-Linked ImmunoSorbent Assay. See more with KPL ELISA products Get higher signal and lower background.

icycler iq Real-Time PCR Detection System Instruction Manual

Molecular characterization, detection & quantitation of biological products Purin Charoensuksai, PhD

RapID Raw Materials Verification System

Expression Array System

Strep-tag Technology for Molecular Weight (MW) Determinations on Blots Using Precision Plus Protein Standards

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

One-Step Western TM Kit using TMB

Boundary-breaking acoustic focusing cytometry

Transcription:

Azure cseries A new way to see the light. c600 c500 c400 c300

Infrared Laser Excitation for Quantitative Western Blot Imaging in the NIR Improve Your Data Quality Imaging with infrared dyes offers signal stability and low background fluorescence. Additionally, imaging with NIR dyes allows you to study multiple proteins in a blot, even if those proteins overlap in molecular weight. Azure Biosystem s cseries laser technology offers two IR detection channels enabling a user to image more than one protein in an assay. Sensitive Detection of Proteins with Chemiluminescent Westerns Get Out of the Dark The Azure cseries provides accurate and fast chemiluminescent detection, as well as the sensitivity, dynamic range, and linearity needed for quantitative blot analysis. Get the best picture every time, and stop wasting money on film. Use Cy 5/Cy 3/Cy 2 Dyes, Blue-Excited DNA Dyes, and More A Total Solution for Western Blot Imaging and Gel Documentation The cseries is a multichannel, multimodal imager, with IR, visible light, and UV excitation channels. Detect Cy dyes, Alexa dyes, Safe dyes, and more.

Azure cseries Features Easy Installation Just unpack, power-up and start. No technician required. Compact, Integrated Design A unique design and integrated tablet computer gives this system a small footprint, saving you room for other tools on the benchtop. Simple Image Saving Save to a USB drive, to a network via WiFi or Ethernet, or print to a printer. Fully Upgradeable All models can be easily upgraded at a later time to accommodate additional applications. AzureSpot Analysis Software Analysis tools for 2D densitometry, automatic land and band detection, background correct, molecular weight calculation, and annotation. Tablet 10.1 tablet controls the system with the touch of a finger. Networking is easy, with WiFi or Bluetooth. Laser Diodes at 660 nm and 785 nm Narrow band excitation enables NIR applications with better sensitivity than LEDs or white light sources. RGB LEDs Excitation at 460, 526, and 628 nm for Cy2/Cy3/Cy5 or similar. EPI White Lights Provide overhead illumination for white light imaging. EPI Blue LED at 470 for Blue-Excited DNA Dyes All systems come standard with excitation for dyes like SYBR Safe, enabling the user to use dyes that are less harmful to the DNA sample, and to the environment. Visible Dye Imaging Transilluminated light source for visible or white light dyes such as Coomassie gels or similar.

High Resolution Camera Capture the finest details of your sample. Deep Peltier Cooling -50 C regulated cooling for low-noise images. Dual-Focus Technology Image samples in perfect focus, and with optimal lens settings, without having to touch the camera. 7 Position Filter Wheel The motorized filter wheel allows flexibility of applications. Chemi Blot Shelf Place chemiluminescent blots closer to the detector on an adjustable shelf (stored in the door when not in use). 3 USB Ports Connect to a drive or network, or attach a thermal printer. FOV The large field of view allows imaging of large gels and blots, or multiple gels at once. Dual-Wavelength UV UV illumination with peaks at 302 and 365 nm. Compatible with a wide range of dyes including ethidium bromide, SYBR green, SYBR gold, SYPRO orange, fluorescein, RadiantRed, Texas Red, SYPRO Red. Safety Safety interlock to prevent accidental UV exposure.

Quantitative Analysis of Infrared Fluorescent Westerns Why Fluorescent Westerns? Detect Multiple Proteins in One Assay Two infrared fluorescent channels for detection enable simultaneous two-color analysis. Save time and sample by detecting multiple proteins in the same assay without needing to strip and reprobe the blot, or having to run a second blot. Multichannel fluorescent detection also enables normalization of your intensity values to a loading control to correct for inaccuracies in loading. No Rushing to the Darkroom With infrared dyes, data are not contingent on the lifespan of an enzymatic reaction. Using secondary antibodies labeled with IR dyes, detection is convenient. No more rushing to the darkroom before the signal decays. IR dyes offer advanced signal stability for reproducible data that are not time sensitive. Time Elapsed 0 1 hour 12 hours 1 2 3 4 Western blot of human transferrin, probed with IR800 secondary antibody. Images captured at 60 micron resolution, with the same exposure time. Resolve Co-migrating Bands 1 2 Fluorescent Westerns eliminate the need to strip and reprobe when detecting co-migrating bands. This not only saves money spent on reagents, but also saves time and sample. A B 1 2 1 2 C Simultaneous detection of EGFR and phospho-egfr. Control cells (lane 1) and cells treated with EGF (lane 2) were imaged. EGFR was detected in the green channel (panel B), and phospho-egfr was detected in the red channel (panel C). Panel A shows the green and red channels superimposed.

c600 c500 Why IR Fluorescent Westerns? Increased Sensitivity Because of Reduced Membrane Autofluorescence at Infrared Compared to Visible Wavelengths Nitrocellulose membranes were imaged using lasers with wavelengths at 660 nm and 785 nm. The same membranes were scanned for the same time at 525 nm and 630 nm wavelengths. Autofluorescence was much lower when using infrared wavelengths. Median Pixel Intensity 2000 1800 1600 1400 1200 1000 800 600 400 200 0 525 nm 630 nm 660 nm 785 nm Why Choose the Azure c500 and c600 for IR Fluorescent Westerns? Increased Sensitivity with Laser-excitation of IR Dyes Other CCD based imaging systems use LEDs for excitation of IR dyes, but these LEDs typically do not match the dye excitation peak. Azure s cseries use lasers carefully selected to match the excitation peaks of the dyes for more sensitive detection relative to other systems. A Relative Absorbence 1.0 0.9 0.8 0.7 0.6 0.4 0.3 0.2 0.1 0.0 Excitation Spectra 680 dye Azure cseries Competitor 660 nm 625 nm 250 300 350 400 450 500 550 600 650 700 750 800 Wavelength (nm) Relative Absorbence 100 90 80 70 60 50 40 30 20 10 0 Excitation Spectra 800 dye Azure cseries Competitor B 5000 2500 1250 625 313 156 78 39 20 10 5 2.5 pg Azure, 40 second exposure Laser scanner system, 5 minute exposure 747 nm 785 nm 600 650 700 750 800 Wavelength (nm) 850 900 A) Azure s laser more closely matches the excitation maximum of IR 700 and 800 dyes. B) Azure s performance matches that of the leading lr based laser scanner system.

Western Blotting with Chemiluminescence No Need to Change Your Protocol Already using an HRP substrate? No matter what substrate you are using, the Azure cseries systems are compatible with your current protocol. Instead of using film and a developer, simply place your blot in the cseries to get great results. No Need for a Darkroom Get the sensitivity you trust from film, with the convenience of digital imaging. Using the highresolution, deeply cooled camera of the Azure c300, 400, 500 or 600, and the 0.95 fast lens technology, you can capture images with the same sensitivity as film. The system acts as a darkbox. With digital image collection, data are immediately ready for analysis. A Two slot blots of serially B diluted HRP-coupled secondary antibody were prepared on nitrocellulose. Both blots were treated with a substrate and A) imaged on film for 2 minutes, or B) imaged on the Azure cseries for 2 minutes at full resolution. Note the limited dynamic range and the saturated bands on film, making quantitation difficult. Better Quantitation The biggest advantage of switching to digital imaging is the ability to get more quantitative data from your Western blots. Film saturates quickly, making it impossible to quantify high-abundance bands. The Azure cseries has a broad dynamic range that is coupled with sensitive detectors, allowing quantitation over several orders of magnitude of protein concentrations. Pixel Intensity 35000 30000 Azure cseries R 2 = 0.99613 25000 20000 15000 10000 5000 0 0 5 10 15 20 25 30 35 Antibody (picograms) 0.5 1 2 4 8 16 32 64 pg Azure cseries gives a linear response to a serial dilution of an HRP-coupled antibody. Azure c600

c600 c500 c400 c300 16 bit Imaging for a Wide Dynamic Range A Western blot was imaged on both the Azure c600 (a 16 bit system) and a competitive 12 bit system. While the 10 second exposure appears similar on the different system, the 12 bit system produces an image that is saturated, and not suitable for analysis. 1 sec 10 sec Log Pixel Intensity Azure c600 (16 bit) R 2 = 0.99185 Log Pixel Intensity 12 bit CCD system R 2 = 0.75929 0.10 1 10 100 Log Picograms Protein 0.10 1 10 100 Log Picograms Protein High Resolution Provides Faster Chemi Acquisition A CCD camera has the ability to combine multiple pixels into a single larger pixel or super pixel. This is a technique known as binning. Binning of 1X1, means the full resolution of the camera is used to capture an image. A binning of 2X2 means that the areas of 4 adjacent pixels are combined into one larger pixel, and so on. In a 2X2 bin, the sensitivity to light is increased by 4 times due to the 4 pixel contributions. This is a powerful technique for chemiluminescent Western imaging. The Azure c300 C600 offers 5 levels of binning for optimal image acquisition. 1X1 Binning 5.4 µ 5.4 µ 40 seconds, unbinned 2X2 Binning 10.8 µ 10.8 µ 40 seconds, 2X2 bin **referenced from ccd.com

Flexibility for Your Applications A Total Solution for Western Blot Imaging and Gel Documentation The cseries is a multichannel, multimodal imager, with IR, visible light, and UV excitation channels. Detect Cy dyes, Alexa dyes, Safe dyes, and more. Light Sources The flexibility of Azure s cseries comes from the wide variety of light sources. 302 365 460 470 526 628 660 785 nm cseries Excitation Wavelengths c600 c400 Visible Fluorescence Detection The c400 and c600 have powerful LEDs compatible with Cy5, Cy3 and Cy2 or similar dyes. Carry out multiplex blots detecting 2 or 3 different proteins using 2 or 3 different colors. Cy5 and Cy3 Images Azure 120 micron resolution, less than 1 minute exposure time Laser-Based System 200 micron resolution, >5 minute exposure time

Safe Dye Detection An alternative to ethidium bromide, less-harmful Safe dyes can be imaged with the EPI Blue LEDs standard in the system. Protein Analysis Protein gels stained with Coomassie blue or silver stain can easily be imaged using the visible light application. DNA Detection with Ethidium Bromide With a dual-wavelength 302 nm and 365 nm UV transilluminator, images of ethidium bromide-stained DNA gels can be captured in a fraction of a second. An interlock switch prevents accidental exposure to UV. For band excision, the switch can be overridden with the press of a button, and the UV transilluminator can be pulled out. c600 c500 c400 c300 Blue Light Imaging SYBR Safe, SYBR Gold, SYBR Green White Light Imaging Coomassie Blue, Silver Stain Stain-Free UV Imaging Ethidium Bromide A Snapshot of Compatible Dyes* Alexa Fluor 488 Alexa Fluor 546 Alexa Fluor 555 Alexa Fluor 633 Alexa Fluor 647 Alexa Fluor 680 Chemiluminescence Coomassie Blue Coomassie Fluor Orange Cy 2 Cy3 Cy5 Deep Purple DyLight 488 DyLight 550 DyLight 633 DyLight 650 DyLight 680 DyLight 755 DyLight 800 ECL Plex Ethidium Bromide GelStar IRDye 650 IRDye 680LT IRDye 680RD IRDye 700DX IRDye 750 IRDye 800CW IRDye 800RS Qdot 525 Qdot 565 Qdot 585 Qdot 605 Qdot 655 Qdot 705 Qdot 755 Silver Stain SYBR Green SYBR Gold SYBR Safe SYPRO Orange SYPRO Red SYPRO Ruby SYPRO Tangerine *Other dyes are also possible. Compatible dyes depend on your system configuration.

Choose the system that suits your needs c600 c500 c400 c300 Ultimate Western System Infrared Imaging System Visible Fluorescent Western System Darkroom Eliminator IR Fluorescence Visible Fluorescence Chemiluminescence UV Fluorescence Visible Imaging Blue Excited DNA Dyes IR Fluorescence Chemiluminescence UV Fluorescence Visible Imaging Blue Excited DNA Dyes Visible Fluorescence Chemiluminescence UV Fluorescence Visible Imaging Blue Excited DNA Dyes Chemiluminescence UV Fluorescence Visible Imaging Blue Excited DNA Dyes Upgradeable to c600 Upgradeable to c600 Upgradeable to c600, c500, and c400 cseries Specifications c600 c500 c400 c300 Camera 8.3 MP Cooling -50 C regulated cooling 7 Position Filter Wheel UV 302/365 nm EPI Blue LED Chemi Visible Fluorescent Westerns NIR Westerns Field of View 20 x 15 cm Footprint (W x H x D) 38 x 55 x 36 cm www.azurebiosystems.com info@azurebiosystems.com Copyright 2013 Azure Biosystems. All rights reserved. The Azure Biosystems logo and Azure are trademarks of the Company. Alexa Fluor and QDots are a trademark of Molecular Probes, Inc. Cy3, Cy5 and Cy2 are registered trademarks of Amersham Biosciences. DyLight is a trademark of Thermo Fisher Scientific Inc. ECL Plex is a trademark of GE Healthcare. GelStar is a trademark of FMC Corporation. IRDye is a trademark of LI-COR, Inc. Stain-Free is a trademark of Bio-Rad Laboratories, Inc. SYBR and SYPRO are registered trademarks of Life Technologies. All other trademarks, service marks and trade names appearing in this brochure are the property of their respective owners.