Low viscous (easy flowing) elastic adhesive for wood flooring

Similar documents
High viscous (thixotropic) elastic adhesive for wood flooring

Low Viscosity, Solvent Free Elastic Adhesive for Wood Flooring. Solvent free Odourless Recyclable tin pail EMICODE EC 1 PLUS R, very low emission

Construction. Solvent free elastic adhesive for Wood Flooring. Product Description. Product Data Sheet Edition _1. 1 SikaBond -52 Parquet 1/6

Construction. Solvent Free Elastic Adhesive for Wood Flooring. Product Description

Footfall sound dampening system for wood flooring

3-part thixotropic epoxy patching mortar

1-part polyurethane pourable self levelling floor joint sealant

Product Data Sheet Sikadur -31 CF Normal Product Description Uses ruction Const Characteristics / Advantages

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

1-part elastic joint sealant and multipurpose adhesive

Construction. 1-part elastic sealant for the internal and external caulking of wooden floors. Product Description. Product Data. Form.

Liquid applied polyurea hybrid membrane

1-part PUR highly elastic coating

Sikadur -Combiflex CF Adhesive Type N and Type R are thixotropic two part adhesives based on epoxy resins and fillers.

2-part epoxy primer, levelling mortar and mortar screed

Non-sag, ultra low modulus, neutral cure silicone sealant for pavements

TECHNICAL DATA SHEET SIKALEVEL 25 LATEX SELF LEVELLING 25KG

Construction. Adhesive for bonding Carbon Fibre & Steel reinforcement. Product Description. Tests

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

Sikafloor -161 is an economic, two part, solvent free, low viscosity epoxy resin, suitable for use under hot climate condition.

Construction. 2-part epoxy primer. Product Data

Product Data Sheet Edition 25/01/2006. Sikasil WS-305. Product Description. Uses. Characteristics / Advantages

Construction. 3-part cement and epoxy combination micro mortar for surface sealing. Product Description 1 1/5. Tests

2-part epoxy textured roller and seal coat

PRODUCT DATA SHEET Sikafloor -378

Construction. 2-part epoxy roller and seal coat. Product Description

CHARACTERISTICS / ADVANTAGES

Building Systems. 1-Part Silicone Weatherseal for Structural Glazing. Product Description. Product Data Sheet Edition_1, 2009 Sikasil WS-305 CN

Construction. 2-part epoxy impregnation resin. 1 Sikadur /6

Construction. Sikafloor N Elastic. 1-part PUR highly elastic coating. Product Data Sheet Version 29/03/2011(Corporate edition 12/08/2010)

Sikadur -330 is a two part, thixotropic epoxy based impregnating resin / adhesive.

PRODUCT DATA SHEET Sikafloor -161

Sikalastic -821 LV is a two part, elastic, crack-bridging, rapid-curing polyurethane membrane. Sikalastic -821 LV is for machine application only.

Highly Chemical Resistant Laminate System. Sika Asplit VEL is 2 part, glass fabric reinforced, vinyl-ester based coating and lining system.

1-part elastic sealant for joints exposed to chemicals

2-part epoxy self-smoothing and broadcast system

Construction. 1-part high performance sealant for flooring. Product Description. Environmental Information. Product Data Sheet Edition _1

2-part flexible epoxy coating, chemically resistant and electrostatically conductive

2-pack Polyurethane grout for rail fixing (continuous undersealing)

PRODUCT DATA SHEET Sikafloor -381

1-part Elastic Sealants for Joints Exposed to Chemicals

Icosit KC 340/45 is a flexible two-component polymer grout based on polyurethane resin, hand and machine applicable.

Construction. 2-part epoxy protective coating. Product Description. Product Data 1 1/5. Test. Form. Storage

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

3-Part Epoxy Grouting System for Pile Capping

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Construction. Adhesive for bonding reinforcement. Product Description. Tests. Product Data Sheet Edition 16 December 2014

hüma PARKETTSYSTEM GmbH INSTALLATION GUIDE

2-part, electrostatic conductive epoxy coating

Product Data Sheet SikaFuko Swell-1 Positioning Description Uses Advantages Approval / Standards Construction Product Data Packaging

Construction. Hydrophilic, swellable hose for sealing construction joints in watertight structures. (formerly Sika Injectoflex HPM)

Construction. Sodium silicate based surface hardener, dustproofer, sealing and curing compound for concrete. Product Description.

Construction. Universal anchoring adhesive. Product Description. Tests. Product Data Sheet Edition _1. 1 Sika AnchorFix S 1/6

Part of the Sikaplan WT Membrane System

PRODUCT DATA SHEET Sikafloor -381 ECF

PRODUCT DATA SHEET Sikaflex PRO-3 WF

TECHNICAL DATA SHEET SIKAFLOOR LEVEL 30 25KG. Buy SIKAFLOOR LEVEL 30 25KG at

Construction. High performance joint sealing system. Product Description. System Data Sheet Edition _1. 1 Sikadur Combiflex SG system 1/8

Construction. 3-part cement and epoxy combination mortar for self-smoothening floor screeds of 1.5 to 3 mm. Product Description 1 1/6

2-part epoxy primer, levelling mortar, intermediate layer and mortar screed

Waterproofing and Damp-proofing Cementitious Slurry

PRODUCT DATA SHEET Sikaflex Tank N

Single pack, solvent based Polyurethane, used in Balcony 10, 15 and 20 waterproofing systems

Construction. Pulastic Coating-221 W. 2 Component Polyurethane

One-part High Performance Sealant for Flooring

Cost-effective, single component, polyurethane, liquid waterproofing membrane

Part of the Sikaplan WT Membrane System

Construction. High performance joint sealing system. Product Description 1 1/9. Product Data Sheet Edition 29th October 2015

Construction. Sikafloor -CureHard -24 Transparent Surface Hardener, Dustproofer, Sealing and Curing Compound for Concrete. Product Description Uses

SikaCor 255 Epoxy-binder for mortars on concrete and steel. Protective Coatings

2-part Epoxy Self-smoothing and Broadcast System

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Flooring and Bedding. RonaFloor SL. Self-smoothing seamless epoxy resin flooring system

Product Data Sheet Product Description tio Uses tru n Characteristics / Advantages

ISEGA Certificate of Conformity U 09

TILING SPECIFICATIONS

Construction. Sikagard Part Epoxy Protective Coating. Product Data Sheet Version 20/07/2011(Corporate edition 28/03/2011) Product Description

Construction. 2-pack Polyurethane grout for rail fixing. Product description. Product data. Product Data Sheet Edition 08.

PRODUCT DATA SHEET Sika Galvashield XP

Carbon fibre shear links for structural strengthening

Understanding the requirements when laying wood flooring over calcium sulphate based screeds

Construction. Carbon fiber shear links for structural strengthening. System Description. (Template for local translation, only for internal use)

UNDERSTANDING THE REQUIREMENTS OF GYPSUM CALCIUM SULPHATE ANHYDRITE OR ALPHA HEMIHYDRATE SCREED IN FLOORING AND INSTALLING WOOD FLOORING

PRODUCT DATA SHEET Sikalastic -560

2-part epoxy coating, chemically highly resistant and electrostatic conductive

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

TECHNICAL DATA SHEET AUS-FLEX MULTI

GREENFORCE ADVANCED TRI-LINKING ADHESIVE AND MOISTURE CONTROL MEMBRANE. Use Environments. Substrates. Flooring Types. Cured Physical Properties

ARDEX X 32 MICROTEC Universal Rapid Setting and Drying Thin-to-Thick Bed Mortar

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

Fiber Reinforced Tile and Stone Mortar

DURABASE CI. Underlay mats for decoupling and sealing tiled flooring 1/5 A P P L I C A T I ONS AND FUNCTION.

Coloured Mineral Dry Shake Floor Hardener

High-performance anchoring adhesive. n Styrene-free n Low odour n Low wastage n No transportation restrictions

Screedmaster Ultimate

2-part PUR Resin Self-Smoothing Screed, Intermediate and Sealer Coat

Fields of application

PROBERT S TIP: Technical terms from A to Z. DIY Lexicon. Nur im

Construction. Sikafloor -262 AS N. 2-part epoxy electrostatic conductive self-smoothing system. Positioning Description.

Transcription:

Product Data Sheet Edition 26/08/2005 Identification no: 02 05 02 03 003 0 000001 Low viscous (easy flowing) elastic adhesive for wood flooring Construction Product Description Uses Characteristics / Advantages Product Data Form Colour SikaBond -T55 is a one part, elastic adhesive. With SikaBond -T55: Solid- and engineered wood floors (strips, longstrips, planks, panels, boards) mosaic parquet, industrial parquet, wood paving (residential) as well as chipboards can be bonded 1-part, ready to use Fast curing Elastic, footfall-sound-dampening adhesive Suitable for common types of wood floors Especially for problematic wood such as beech and bamboo Suitable for bonding wood floors directly onto old ceramic tiles Reduces stress on the substrate: the elastic, material-compatible adhesive reduces transverse stress between the wood floor and the substrate Suitable for subfloor heating Adhesive can be sanded Ochre Packaging 13 kg metal pails (=10 litre) Storage Storage Conditions / Shelf Life 12 months from date of production if stored in undamaged original sealed containers, in dry conditions and protected from direct sunlight at temperatures between +10 C and +25 C. 1 1/5

Technical Data Chemical Base 1-part Polyurethane, moisture curing. Density ~ 1.34 kg/l (DIN 53 479) Skinning- / Laying Time Curing Rate Sag Flow Service Temperature Mechanical / Physical Properties ~ 45-60 minutes (+23 C / 50% r.h.) ~ 4.0 mm/24h (+23 C / 50% r.h.) Floor may be walked on / sanded 12-24 hours after installation (depending on climatic conditions and adhesive layer thickness). Consistency: Spreads very easily, trowel marks stable. -40 C to +70 C Shear Strength ~ 1.0 N/mm 2, 1 mm adhesive thickness (+23 C / 50% r.h.) (DIN 281) Tensile Strength ~ 1.5 N/mm 2 (+23 C / 50% r.h.) (DIN 53 504) Shore A Hardness ~ 35 (after 28 days) (DIN 53 505) Elongation at Break ~ 400% (+23 C / 50% r.h.) (DIN 53 504) System Information Application Details Consumption Substrate Quality Full Surface Bonding: 700-900 g/m 2 with notched trowel B3 (acc. to IVK guidelines) or 3 / 16 " 1 / 8 " 1 / 8 " (engineered strips / planks, mosaic parquet). 800-1000 g/m 2 with notched trowel B11 (acc. to IVK guidelines), AP 48 or 3 / 16 " 3 / 16 " 3 / 16 " (solid wood, engineered longstrips / panels, industrial parquet, wood paving (residential), chipboards). For bonding of long, width boards or in case of uneven substrates it could be necessary to use a notched trowel with bigger notches (avert hollow sections). For substrates prepared with Sika Primer MB, the consumption of SikaBond -T55 is lower. Clean and dry, homogeneous, even, free from grease, dust and loose particles. Paint, laitance and other poorly adhering particles must be removed. Standard construction rules must be observed. 2 2/5

Substrate Preparation Concrete / cement screed: Must be ground and thoroughly cleaned with industrial vacuum cleaner. Anhydrite screed / Anhydrite flowable screed: Must be ground and thoroughly cleaned with industrial vacuum cleaner shortly before bonding starts. Broadcast mastic asphalt: Must be primed with Sika Primer MB. Instructions for use, see Product Data Sheet for Sika Primer MB. Glazed ceramic and old ceramic tiles: Degrease, clean with SikaCleaner or grind the tile-surface and clean thoroughly with an industrial vacuum cleaner. Wood- / gypsum boards (e.g. chipboards, plywood,...): Glue / screw the boards to the substructure. They have to be fixed on the substrate. In case of floating subfloors, please contact our Technical Service. Unknown substrates: Please contact our Technical Department. SikaBond -T55 can be used without priming on cement floors, anhydrite floors, chip boards, concrete and ceramic tiles. For broadcast mastic asphalt, cement floors with an excessive moisture content, as well in case of renovation on old adhesive residues and on structurally weak substrates use Sika Primer MB. For detailed instructions consult the Product Data Sheet of Sika Primer MB or contact our Technical Department. Application Conditions / Limitations Substrate Temperature Ambient Temperature Substrate Humidity During laying and until SikaBond -T55 has fully cured substrate temperature must be > +15 C and in case of floor heating < +20 C. For Substrate temperatures the standard construction rules are relevant. Room temperature between +15 C and +35 C. For ambient temperatures the standard construction rules are relevant. Permissible substrate moisture content: - 2.5% CM for cement screed (ca. 4% Tramex / Gravimetric weight percent) - 0.5% CM for anhydrite screed - 3-12% CM for magnesia flooring (proportion of organic parts) Permissible substrate moisture content in case of floor heating: - 1.8% CM for cement screed (ca. 3% Tramex / Gravimetric weight percent) - 0.3% CM for anhydrite screed Relative Air Humidity Between 40% and 70% - 3-12% CM for magnesia flooring (proportion of organic parts) For moisture content and quality of substrates the guidelines of wood floor manufacturer as well as standard construction rules must be observed. 3 3/5

Application Instructions Application Method / Tools Cleaning of Tools Potlife Notes on Application / Limitations Notes Local Restrictions SikaBond -T55 is applied to the properly prepared substrate directly from the pail and uniformly distributed by notched trowel. Press the wood floor elements firmly into the adhesive so that the wood floor underside is fully wetted. The elements can then be joined together using a hammer and a impact block. Many types of wood floors have to be tapped from the top. A distance of 10 mm from the wall to the wood floor must be observed. Fresh, uncured adhesive remaining on the wood floor surface must be removed immediately with a clean cloth and if necessary cleaned with Sika Remover-208. Test wood floor surfaces for compatibility with Sika Cleaner-208 before use. The laying instructions of the wood floor manufacturer as well as standard construction rules must be observed. Clean all tools and application equipment with Sika Remover-208 immediately after use. Hardened / cured material can only be mechanically removed. ~ 45 minutes SikaBond -T55 is only suitable for experienced applicator. If, according to wood floor suppliers or producers deviation from the standards is permissible, temperatures between +5 C and +35 C must be observed for the adhesive. For better workability the adhesive temperature must be at least +15 C. For the proper curing of the adhesive sufficient ambient moisture is necessary. Wood floors in non insulated areas such as basements, or other areas without a damp proof membrane, must only be installed after the application of Sikafloor EpoCem sealed with Sika Primer MB to control the moisture. For detailed instructions consult the Product Data Sheets or contact our Technical Service. In case of chemically pre-treated types of wood floors (e.g. ammonia, wood stain, timber preservative) and woods with high oil content SikaBond -T55 is only to be used after a written recommendation from our Technical Service. Do not use on PE, PP, TEFLON, and certain plastizied synthetic materials (carry out pre-trials or contact our Technical Service). Some primers can negatively influence the adhesion of SikaBond -T55 (pre trials recommended). All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. 4 4/5

Construction Health and Safety Information Protective Measures Ecology Transportation Class Important Notes Toxicity Legal Notes To avoid rare allergic reactions, we recommend the use of protective gloves. Change soiled work clothes and wash hands before breaks and after finishing work. Local regulations as well as health and safety advice on packaging labels must be observed. Residues of material must be removed according to local regulations. Fully cured material can be disposed of as household waste under agreement with the responsible local authorities. Detailed health and safety information as well as detailed precautionary measures e.g. physical, toxicological and ecological data can be obtained from the material safety data sheet. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika Limited Watchmead Welwyn Garden City Hertfordshire AL7 1BQ United Kingdom Phone +44 1707 394444 Telefax +44 1707 329129 www.sika.co.uk, email: sales@uk.sika.com ISO 14001 ISO 9001 5 5/5