GEOTHERMAL HEAT PUMPS CONFIGURATIONS/INSTALLATION

Similar documents
White Paper. Geothermal Heating and Cooling

THE GEOTHERMAL ADVANTAGE

2. Ground Source Heat Pumps Invitations to complete questionnaire Responses received... 7

Pitfalls of Rules of Thumb in Geothermal Heat Pump Design

Information for Evaluating Geoexchange Applications

Horizontal Borehole Study

The desire for fossil fuel alternatives and environmentally friendly energy has

Geothermal Comfort Systems

Research on Ground Source Heat Pump Design

Parametric Study for Evaluation of Design Parameters of Standing Column Well

Geothermal Heat Pump Systems Metropolitan Washington Council of Governments Built Environment and Energy Advisory Committee May 19, 2016

Steve Kavanaugh Professor Emeritus The University of Alabama

Bioreactor Landfill Design

CLOSED-LOOP HEAT EXCHANGER FOR GROUND COUPLED HEAT PUMPS

Ground Source Heat Pump System Design and Permitting AWWA Pacific Northwest Section Conference, May 6-8, 2009 Salem, Oregon

GEO-HEAT CENTER EXECUTIVE SUMMARY

September Hybrid Air, Solar, and Ground Source Heat Pump Designs. Gaylord Olson, Yao Yu

Optimal Design for a Hybrid Ground-Source Heat Pump

Thermal Efficiency of the Borehole Heat Exchanger Built with Drilling Mud.

Limitations of Using Uniform Heat Flux Assumptions in Sizing Vertical Borehole Heat Exchanger Fields

Modeling of Standing Column Wells in Ground Source Heat Pump Systems

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

Water Well Decommissioning Guidelines

Residential Swimming Pool Heating with Geothermal Heat Pump Systems

Thermal Energy Storage

AB 2339 WORKING GROUP DRAFT DOCUMENT. Draft Energy Commission Policy for Ground Source Heat Pumps April 19, 2013

NGWA s Water Well Construction Standard: ANSI/NGWA 01-14

EVALUATION AND DESIGN OF DOWNHOLE HEAT EXCHANGERS FOR DIRECT APPLICATION

Soil Temperature Monitoring and Study of Geothermal Heat Pump Systems

LANDFILL GAS CONTROL SYSTEMS: DESIGN AND CONSTRUCTION CONSIDERATIONS. Mike Bradford, P.E.

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

Chapter 9: Applications of the Laws of Thermodynamics

The Springville City General Plan discusses Community Services and Facilities and contains the following goal:

STATE OF COLORADO DIVISION OF WATER RESOURCES OFFICE OF THE STATE ENGINEER

Local Conduction Heat Transfer in U-pipe Borehole Heat Exchangers

Water Issues Relating to Unconventional Oil and Gas Production

SorTech package solution description

Use of Geothermal Energy in Snow Melting and Deicing of Transportation Infrastructures

TEMPERATURE STRATIFICATION OF CIRCULAR BOREHOLE THERMAL ENERGY STORAGES

DIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT

DISTRIBUTED TEMPERATURE MEASUREMENTS ON A MULTI-PIPE COAXIAL BOREHOLE HEAT EXCHANGER

Altela, Inc. Treating water naturally

2016 ANNUAL ICR AND TRR WELL FIELD REPORT ICR WATER USERS ASSOCIATION

GRAY WATER RECYCLING SYSTEMS

ANALYSIS OF A HEAT PUMP SYSTEM BASED ON BOREHOLE HEAT EXCHANGERS FOR A SWIMMING POOL COMPLEX IN KRYNICA, S-POLAND

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

EVALUATION OF A HIGH TEMPERATURE SOLAR THERMAL SEASONAL BOREHOLE STORAGE

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Module 2. The Science of Surface and Ground Water. Version 2 CE IIT, Kharagpur

CTD (CONDUCTIVITY-TEMPERATURE-DEPTH)

Green Movement Energizes Growth at ClimateMaster. Product Focus: Heating and Cooling. Company Profiles. plumbing heating cooling.

SIMULATION AND MODEL CALIBRATION OF A LARGE-SCALE SOLAR SEASONAL STORAGE SYSTEM

SECTION2 Drainage Control for Surface Mines. Some Technical Aspects of Open Pit Mine Dewatering

Infiltration Guidelines

Ground-Coupled Heat Pump And Energy Storage

Natural Gas A Game Changer

Water Dependency of Geothermal Power Generation Systems

Geothermal Systems: Harnessing Earth s Energy

CONCENTRATE AND BRINE MANAGEMENT THROUGH DEEP WELL INJECTION. Abstract

is a possibility of the existence of permafrost as a result

Observations from Several Condition Assessments of Prestressed Concrete Cylinder Pipe used at Energy Generation Facilities

Simulations of a New Double U-tube Borehole Configuration with Solar Heat Injection and Ground Freezing

Steam Cooling Systems and Hybrid Cooling. Andrew G. Howell Xcel Energy

Delta School District #37 Geothermal Project A new direction for provincial Facilities

Drilling for Natural Gas in the Marcellus and Utica Shales: Environmental Regulatory Basics

Geothermal Energy for the Renewable Energy House

Challenges of Cementing Olkaria Geothermal Field

CHAPTER 13 OUTLINE The Hydrologic Cycle and Groundwater. Hydrologic cycle. Hydrologic cycle cont.

Determination of Design Infiltration Rates for the Sizing of Infiltration based Green Infrastructure Facilities

Chilled Water Distribution Systems. APPA Institute for Facilities Management New Orleans, LA January 19, 2016

HYBRID ENERGY MICROPILES IN UNDERPINNING PROJECTS COMBINATION OF LOAD BEARING STRUCTURES AND GEOTHERMAL ENERGY FIELD

Michigan Department of Environmental Quality Resource Management Division Office of Oil, Gas, and Minerals

Climate Control Solutions. Geothermal. A New Level of. Comfort. & Reliability.

22 Tubewell Drainage Systems

Groundwater Hydrology

7. Completing the Well s Structure

District Energy in Toronto. Climate & Clean Air Coalition Sustainable Technologies for Air-Conditioning Workshop November 18 th, 2017

P Temporary piezometer. MW Piezometer to remain in place. P Temporary piezometer

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

Comparative Heating Performances of Ground Source and Air Source Heat. Pump Systems for Residential Buildings in Shanghai

Design Guideline for Gravity Systems in Soil Type 1. January 2009

SEWER SYSTEM DESIGN GUIDELINES

East Maui Watershed Partnership Adapted from Utah State University and University of Wisconsin Ground Water Project Ages 7 th -Adult

GROUNDWATER COMPONENT IN MINING OPERATION-MINING HYDROLOGY

Thermal Pollution. Thermal Pollution-Niladri Chakrabarty

NUMERICAL STUDY ON THERMAL DEPLETION OF THE GROUND AROUND A GEOTHERMAL HEAT PUMP S PROBE

Walls generally range from 600 to 1500 mm thickness, in wide between 2000 and 3500 mm and can be excavated to depths of 60m or more.

3/6/2017 Past president & currently on the board of directors for the Wisconsin Geothermal Association

SIMULATION AND OPTIMIZATION OF GROUND SOURCE HEAT PUMP SYSTEMS

A. This Section includes exterior piping for vertical, direct-buried, ground-loop, heat-pump systems that operate between 23 and 104 deg F.

Environment Protection Engineering ECOLOGICAL HEATING SYSTEM OF A SCHOOL BUILDING. DESIGN, IMPLEMENTATION AND OPERATION

GEO-HEAT CENTER EXECUTIVE SUMMARY

Efficient usage of waste heat by applying a seasonal energy storage (BTES) at ITT Water & Wastewater AB, Emmaboda, Sweden

Division Mandates. Supervise the drilling, operation, and maintenance of wells to prevent damage to life, health, property, and natural resources.

Experience with Propellant Well Stimulation

1. All underground utilities under railroad tracks shall be encased in a larger pipe or conduit called the casing pipe.

FEASIBILITY STUDY ON THE UTILIZATION OF GEOTHERMAL HEAT PUMP (GHP) SYSTEMS IN JAPAN

Hydrology. Jürg M. Matter Lamont-Doherty Earth Observatory, The Earth Institute at Columbia University. May 9, 2008

Water Use for Oil & Gas Operations in Oklahoma

Transcription:

GEOTHERMAL HEAT PUMPS CONFIGURATIONS/INSTALLATION There are three main categories when dealing with geothermal heat pumps; open-loop, closed-loop, and direct-exchange. The closed-loop and direct-exchange systems can be arranged in either parallel or series configurations. OPEN-LOOP SYSTEMS In an open-loop system, heat transfer is performed with surface or groundwater. The water is taken into heat pump units and then discharged into the environment. There are several types of open-loop configurations that can be used depending on the surrounding conditions and needs of the building. SINGLE-WELL SYSTEMS Single-well systems rely on a lone well that serves as a water supply to the open-loop system. The water is pumped into the system and released after it is used into a drainage field or an existing body of water. An example of an open-loop single well is displayed in Figure 6. These systems provide an economical solution to a groundwater heat pump if there is a preexisting well. In residential situations, a domestic water supply well could possibly be too small to meet the water needs of the groundwater heat pump. Residential wells typically produce 300 to 400 gallons of water per day, where a groundwater heat pump for the same residence may require thousands of gallons of water per day. In addition to this, the water discharged from the system may be limited by environmental or local regulations. A slightly modified single-well system which may alleviate some of these concerns is a standing-column well. 6

STANDING-COLUMN WELLS A standing-column well uses the same concepts as a single-well system, except in a standing-column well most to all of the discharged water is dispensed into the original well source. This minimizes the amount of water discharge from the system into the environment. A standing-column well system is feasible when there is accessibility to fractured bedrock aquifers near the ground surface. A standing-column well typically consists of an installation of uncased boreholes 6 inches in diameter and at a depth of 1000 to 1500 feet. The surrounding aquifer is in contact with the borehole, which allows the formation of a standing column of water from the bottom of the well to the top of the groundwater table. An example of a standing-column well can be seen in Figure 7. The water for the system is drawn from the bottom of the well and discharged into the top of the well. This allows for no net withdrawal from the groundwater itself. At times of higher demand for heating or cooling, this type of system can bleed, which means it returns only a portion of the water back to the well and the other portion is discharged into the surrounding environment. When this bleeding occurs a net groundwater inflow happens within the column. This chills the standing column during periods of peak heat rejection (when building demand for cooling is the greatest) and/or warms it during peak heat extraction (when heating demand is greatest), thus reducing the required bore depth., [Virginia Tech Website]. In comparison to closed-loop geothermal heat pump systems, a standing-column well can save the owner significantly if it is well designed and accurately sited. The ground area required to install a standing-column well is the least of any geothermal heat pump system, making this type of system ideal for areas with limited space and the proper geological conditions.

7 DOUBLE-WELL SYSTEMS Double-well systems consist of both a supply and discharge well. Similarly to standing-column wells, a doublewell system may be used in instances where there are water discharge regulations or limits. An important design aspect of this type of open-loop system is the distance between the supply and discharge wells. A main consideration when determining the distance between the wells is the flow rate from the injection well to the production well. There may be a flow between wells, but it must be low enough so that the discharged water arriving at the production well is approximately the same temperature as the natural aquifer. Typical well spacing in a double-well system is in range of 200 to 600 feet. This is largely dependent upon the maximum system heat/cooling loads, time span of these maximum load conditions, and the natural flow rate and thickness of the aquifer. An example of a double-well system is shown in Figure 8.

8 SURFACE WATER SYSTEMS A surface water system uses a larger body of water like a lake or an ocean for both the water supply and discharge points. If the water body is deep enough to have a thermocline in a source containing thermal stratification, a source of cold water that remains undisturbed is available year round. Sometimes, this colder water provided by the water supply may be enough to provide direct space cooling using water/air heat exchangers. This eliminates the need for heat pumps or refrigerant to cool the building interior. When using this direct space cooling method, the temperature of the building loop water must remain below 55 F to provide effective dehumidification. Data from lakes in Alabama suggest that significant thermal stratification occurs in lakes deeper than 30 feet, with bottom water temperatures between 45 and 55 F throughout the year, even when summer surface water temperatures reach 80 to 90 F." 9 ISOLATION HEAT EXCHANGER Indirect open-loop systems employ an isolation heat exchanger between the building loop and the water supply. This eliminates exposure of building water loop or heat pump components to poor-quality supply water, making more sites potentially attractive for open-loop systems. The isolation heat exchanger also allows the

building loop and supply water loops to be operated at different flow rates and pressures for optimal thermal and hydraulic performance. 10 EVALUATING OPEN-LOOP FEASIBILITY WATER QUALITY Heat exchanger is exposed to dissolved ions, suspended solids, and microorganisms from the supply well. The heat exchanger is prone to scaling and buildup of corrosion films and fouling. The thermal and hydraulic resistance to heat transfer is increased, which decreases overall efficiency. Water treatment is not economical. WATER AVAILABILTY Required groundwater flow rate typically is between 2-3 gallons per minute per system ton. DISCHARGE WATER PERMITTING Groundwater must be re-injected into the ground or drainage system. Must follow local water discharge regulations. Water is discharged at higher elevation than the intake point which represents a static pressure head. This requires more power to overcome by the circulating pump. CLOSED-LOOP SYSTEMS Closed-loop systems are the most common geothermal heat pumps. They circulate the working fluid through the pipes and do not use a water source. They work by only transfering heat through the piping networks meaning that there is no direct interaction between the working fluid and the earth. The length of required piping depends on ground thermal conductivity, ground temperature, and heating and cooling power needed, as mentioned in Geothermal Basics above. The most common closed-loop systems are: vertical, horizontal, slinky, and pond. HORIZONTAL CLOSED-LOOPS

Horizontal closed-loop systems are composed of pipes that run horizontally through the ground. A long horizontal trench, deeper than the frost line, is dug and U-shaped coils are placed horizontally to connect the pipes. A trench for a horizontal loop field will be similar to one seen under the slinky loop field. The width of the field is dependent on the number of pipes. Horizontal loop fields are very common and economical if there is adequate land available. 11 SLINKY CLOSED-LOOPS A slinky closed-loop field is installed in the horizontal orientation with an overlaying piping network. Slinky loop fields are used when there is not adequate space for a horizontal closed-loop system. Slinky closed-loop systems have easy installation.

12 VERTICAL CLOSED-LOOPS Vertical closed-loop fields are oriented with a piping network running vertically into the ground. Holes are bored into the ground about 150-250 feet deep. There are U shaped connectors at the bottom of the hole connecting pipes. The borehole is commonly filled with a bentonite grout surrounding the pipe to provide a good thermal connection to the surrounding soil or rock to maximize the heat transfer. Vertical closed-loop fields are ideal for limited areas. During the cooling season, the local temperature rise in the bore field is influenced most by the moisture travel in the soil.

13 OTHER TYPES OF CLOSED-LOOP SYSTEMS Submerged closed-loops Hybrid loop with cooling pond Hybrid loop with cooling tower Hybrid loop with solar collector

14 DIRECT EXCHANGE (DX) LOOPS Direct exchange systems have a refrigerant circulating through copper pipes which are drilled directly into the ground, eliminating the need for a heat exchanger between the refrigerant loop and the water loop and the water pump. The DX loop systems have many benefits, including: Simple installation Higher efficiencies Shorter and smaller piping Lower installation costs

Can also be used for home water heating Very long lifetimes 15 Horizontal DX Arrangement: Horizontal-loop DX systems require about 350 feet of copper tubing per system ton, as opposed to 450 to 500 feet per ton for polyethylene ground loops. Because of their shorter length, horizontal DX ground loops need only about 500 square feet of land area per system ton, considerably less than the 1,500 to 3,000 square feet needed for conventional horizontal closed-loops. 16

17 Vertical DX Arrangement: Vertical DX systems require only a 3-inch diameter bores to a depth of 120 feet per ton, as opposed to 4- to 6-inch diameter bores to a depth of 200 to 300 feet per ton for polyethylene U-tubes in conventional vertical closed loops. Vertical DX loops need at least the same land area as their conventional counterparts, or even somewhat more. Vertical DX boreholes should be spaced at least 20 feet apart to minimize the possiblity of ground freezing and buckling in the heating mode or excessive warming and drying of the soil in the cooling mode. 18 Source : http://me1065.wikidot.com/geothermal-home-heating-and-cooling