than 2.1 lb per ft 3 or 33 lb per module (2 ft x 2 ft x 4 ft bundle of fastened sheets).

Similar documents
MARPAK modular biomedia WASTEWATER TREATMENT

How to Design a Singly Reinforced Concrete Beam

PRECAST CONCRETE ON-SITE WASTEWATER TANKS

Design of Semi gravity Retaining Walls

SECTION I FLEXIBLE PIPE VS. RIGID PIPE (GENERAL)

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

June 1, 2012 PARTIES INTERESTED IN COLD-FORMED STEEL FRAMING MEMBERS

Testing Packaged Products Weighing More Than 150 Lbs.

Standard Test Methods for Transmitted Shock Characteristics of Foam-in-Place Cushioning Materials 1

Survey and Testing of Pre-1988 Braced Frame Structures From The West Coast of the United States

Standards for Testing and Rating Shoring Equipment

HP COMPRESSION TEST METHOD A Rev. A

CHAPTER 12 TRICKLING FILTER PLANTS

screens TM A Weatherford Company MUNI-PAK DESIGN TECHNOLOGY

AMERICAN NATIONAL STANDARD ANSI/NAAMM STANDARD. Maximum Bearing Bar Depth / 2 (63.5 mm)

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

SESSIL TRICKLING FILTERS

LPI 56 Technical Guide

Reinforced Concrete Tilt-Up Wall Panel Analysis and Design (ACI 551)

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Allowable Loads for Round Timber Poles

Technical Bulletin 132. Diffused Air Mixing Requirement. by:

Figure Trickling Filter

3. CLASSIFICATION AND IMPLICATIONS OF DAMAGE

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

RB WEIR GATES MODEL GENERAL DESCRIPTION DESIGN CONSTRUCTION

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

The Carport - Bryan, Texas

Snow load design using the 2003 International Building Code

Biofilm Reactor Technology and Design

Module 20: Trickling Filters Answer Key

Testing Packaged Products Weighing up to 150 Lbs.

ASE SYSTEMS. EPOXY RESIN FLOOR Prep / REPAIR SYSTEM For Air Caster Load Moving Equipment

DynoRaxx EVOLUTION PR Guide to Code Compliant Installation

Precast Concrete Bearing Wall Panel Design (Alternative Analysis Method) (Using ACI )

TECHNICAL NOTE On Cold-Formed Steel Construction

Structural Engineering

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

PUSH-BACK. storage rack systems EXCEL STORAGE PRODUCTS EXCEL STORAGE PRODUCTS EXCEL STORAGE PRODUCTS EXCEL STORAGE

W. Mark McGinley March 3, 2016 ISEA MEETINGS 1

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM


Design of Short Span Steel Bridges

OTEC 2017 Spray Applied Pipe Liner Supplemental Specifications 833 Calculations for the Resin Based Liner Presented by Peter Blais, PE

Analysis 2: Greenroof Design

INSTALLATION OF REFRACTORY FIBER KILN AND FURNACE LININGS

Weir Specialty Pumps. WEMCO Torque-Flow

THE BRACE CONNECTION THE BOLTED OPTION FIGURE 1 MODEL SHOWING THE BOILER AND THE STRUCTURAL SUPPORT SYSTEM (BOILER BUILDING)

SECTION ALUMINUM GATES

LAMINATED VENEER LUMBER

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

MWF Advanced Floor. User Guide. Last Updated on July 27 th 2015

Full-Scale Bending Tests of Strongwell s SE28 Fiberglass-Reinforced Polymer Poles

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

PV Newsletter Monthly Publication from CoDesign Engineering Academy

SPECIFICATION FOR PREFABRICATED VERTICAL DRAINS

1. Cast-in-place concrete is specified in Section

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

MECHANICAL BRIDGING AND BRIDGING ANCHORAGE OF LOAD BEARING COLD-FORMED STEEL STUDS. Paul E. Lackey, EIT Nabil A. Rahman, Ph.D.

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

MC-3500 and MC-4500 Design Manual

Figure 5 - A shoring tower is made by assembling end frames with diagonal braces

Chapter 4 Load Tables for Flexural Members and Connections

Selecting The Right Cushion

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

Proudly Made in the U.S.A.

YOUR SPLASH PAD RESOURCE

10/10/2007. Is it Dark at Night?

Water Utility Science Water Math and Hydraulics 050. Name: Date:

Page 10-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LIGHTING AND SIGNS

MS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

Would You Like Concrete With Little or No Shrinkage, Cracking, and Curling??? We Will Focus on:

Editing notes to assist users are separated from specification text by rows of asterisks. Delete these notes prior to final printing.

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

Overturning Forces. 12 times 300 lbs = 3,600 lbs of shear force along top of wall. Shear Wall

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

SECTION PLATE CONNECTED WOOD TRUSSES

SHEET METAL ROOF TEST REPORT

LMSSC PACKAGING STANDARD

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle

Design Data 6. Loads and Supporting Strengths Elliptical and Arch Pipe. Values of B d

Understanding compact shelving

COMPOSITE MATERIALS HANDBOOK. Volume. Structural Sandwich. Composites

Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement 1

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing

CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES 9.2 TYPES OF STAIR CASES

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

ADDENDUM No. 6. ITB No. 4424: W.R. Wheeler (Swift Run) Service Center PUD Non-motorized Improvements Phase 1

Chip Sealing The Nuts and Bolts. Thomas J. Wood Research Project Supervisor MN/DOT

LAKESIDE Water Purification Since Bulletin #1218 Revised June Spiravac Clarifier. Peripheral Feed Center Takeoff Suction Sludge Removal

REINFORCING TABLES INSTALLATION MANUAL

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

Originally Issued: 03/10/2017 Revised: 03/30/2019 Valid Through: 03/31/ Design

Modal Analysis as a Tool to Resolve Pump Vibration Issues

ITEM 404 DRIVING STEEL PILING

ENGINEERED POWER SOLUTIONS

Individual Truss Marking Is it a Building Code Requirement?

Transcription:

PLASTIC MEDIA - WHERE S THE BEEF? Avoiding Trickling Filter Media Collapse John R. Harrison, CDM 319 SW Washington Ave, Suite 900 Portland, OR 97204 (503) 232-1800 HarrisonJR@cdm.com ABSTRACT: In 1974 the cost of plastic trickling filter media ranged generally from $2.00 to $3.50 per cubic foot. In 1997 the cost for plastic media is nearly the same as it was 20 years ago. Why hasn t the cost of plastic filter media risen dramatically, and are there issues involved that consulting engineers should be aware of or warned about? Photo 1: Warning Presented is a discussion of changes in media manufacturing and on the testing of media. Some of these changes have resulted in confusion as to appropriate specification language for procuring plastic media. The result has been that deficient media was installed at some trickling filter plants. Suggestions are made in this paper as to appropriate specification language for procuring plastic media. Today, there should be no concern that trickling filter media does not have sufficient plastic beef and strength o assure a 20-year life. From 1960 through 1980 there were few changes in media configuration or specification language. However, in the early 1980 s two changes occurred which are of major concern to engineers involved in specifying plastic media. The first change was the introduction of the short-term (approximate 2-hour) test for determining the minimum allowable bearing strength of a plastic module. Prior to 1982 plastic vertical flow (VF) media had been specified principally by specifying minimum sheet thickness (from 18 to 27 mil) and requiring that media conform to a 96-hour bearing capacity test with an allowed 2% deflection at 760 lbs/ft 2 at a test pressure of 75 F. Another common specification item in 1974 was that module weight was to be no less than 2.1 lb Photo 2: VF PVC Module per ft 3 or 33 lb per module (2 ft x 2 ft x 4 ft bundle of fastened sheets). The second major change which occurred from 1982 to 1984 was the active promotion of cross flow (XF) media as a replacement for VF media. The introduction of XF media brought on a series of concerns as to whether traditional specification values were appropriate for the slanted-corrugated sheets versus the alternating flat and vertically corrugated sheets. Of primary concern was the possibility of solids buildup or partial plugging with XF media, which could add to the live load of the media. There was also a need to account for the corrugation process which includes stretching sheets so that the after forming thickness may be only 60 to 70

percent of the before forming or flat sheet thickness. Variations in the success and quality of plastic modules supplied from the early 1980 s through mid 1990 s is illustrated by comparing media at three different facilities. Table 1 presents the data from these facilities, where the media was supplied by the same manufacturer. In 1982 the testing of traditional VF media (Table 1* - Facility A) using a 96-hour test resulted in a fairly 2. Wastewater containing fouling characteristics 3. Improper use of media with irregular geometric shapes (cross flow and random) 4. Non-uniform media support systems, and 5. Poor fabrication and installation problems. This paper discusses engineering design choices which are critical in avoiding problems related to the primary causes of media collapse. PRIMARY CAUSES OF COLLAPSE Photo 3: XF PVC Media substantial media containing slightly over 34 lbs of PVC per module of dry fabricated product. The introduction of XF media (Table 1 - Facility B), and the use of the 2-hour or short-term test with allowance of a 1.25 percent deflection, resulted in a reduction in PVC weight to 25 lbs per module. Even with this reduction in module weight and sheet thickness, the media at Facility B has performed satisfactorily for nearly 15 years. However, the media at Facility C was installed in 1992 and collapsed within 5 years. The reduced module weight and sheet thickness at Facility C are the primary suspected causes of failure. Other suspected contributing factors to filter media failures have been: 1. Poor solids capture prior to the biofilter In the mid 1970 s plastic self-standing media was made almost entirely of fastening alternating flat plastic sheets with corrugated plastic sheets. Manufacturing was done by only one or two companies within the United States and material data sheets Photo 4: Collapsed Media Layer readily identified both the properties of the individual PVC sheets and the weight and

bearing strength of the fabricated modules. A typical module (2 ft x 2 ft x 4 ft) was specified to weigh greater than 2.1 lbs per ft 3 and (claimed some product data sheets) could withstand a 96-hour compression test with less than 2% deflection with a bearing load of 760 lbs/ft 2 at 75 F. Many engineers did not require confirmation testing because of the time and expense of performing the long-term test. If requested, most media manufacturers submitted results from a short-term 2-hour test specifically performed on media to be supplied for that particular project. The 2- hour test had not been standardized but could be correlated to the 96-hour long-term test. By the early 1980 s a new short-term (2-hr) test was formally introduced at a wastewater conference by Jean Mabbott of B.F. Goodrich. By the mid-1980 s most consulting engineers were aware of the need to require specific testing of media and included was controlled by a wave with minimum height of 1.5 to 1.75 inches. When Mabbott introduced the short term test in 1982, a 1.0 percent deflection was recommended for testing purposes so that not too much plastic material would be deformed or otherwise obstruct the vertical flute opening and inhibit biological soughing. With the introduction of XF media, the wave height has been generally reduced to 1.25 inches and the previous vertical flute has been tilted to provide a break for water that might otherwise fall vertically without intimate contact. Some engineers failed to heed or understand the potential need to use less than a 2 percent deflection criteria on media tests. The need for a reduced allowable deflection in the bearing test results from: a) reduced wave height, b) change in media geometry, and c) a 48-fold (96 hr:2 hr) reduction in testing time. Those engineering firms Photo 5: Deflection on Module Surface who used a 1.0 to 1.25 percent deflection in their 2- specification language associated with the shortterm test. Unfortunately, media of inadequate hour bearing strength media specification strength may have been supplied where the generally obtained media with more plastic engineering specifications did not properly beef than those who retained a 2% deflection address the following issues. criteria. Allowable Deflection With the 96-hour test, a 2 percent deflection had historically been allowed with vertical media. When considering deflection it is important to recognize that the original 2 percent allowance was associated with a media whose corrugated open vertical flute Sheet Thickness and Module Dry Weight With VF media in the 1970 s one major manufacturer offered three sheet thicknesses: 27 mil (extra heavy), 23 mil (heavy), and 18 mil (standard). Their forming (bending or corrugating) process was done so that there

was no difference between the sheet thickness before or after forming. However, with the introduction of XF media most manufacturers produced corrugations by thermoforming which stretches the media so that consideration should be given to both before and after forming sheet thickness. The after forming thickness is a direct ratio of the surface area of sheet material prior to and after the forming of a module. For example, with a standard shaped module made of 19 sheets with a flat surface area of 16 square feet per sheet, the total uncorrugated or before forming surface area would be 304 square feet. If the supplied or after fabricated media contains 30 ft 2 per ft 3, then the after forming area is 480 ft 2 (30 ft 2 /ft 3 x 16 ft 3 ) and the area ratio is 0.63 (304 ft 2 /480 ft 2 ). Therefore, if the plastic modules are formed from 22-mil sheets, the after forming thickness would be approximately 12.7 mils (0.63 x 22 mil). Requiring a minimum before forming thickness of 24 mils has been one method of assuring the media has sufficient PVC. However, it is the after forming thickness that will control the media strength, not the before forming values. Some engineers have either specified too low of an after forming sheet thickness or have not enforced the specified minimum after forming sheet thickness. Since after forming thickness varies, the specification criteria should control the minimum thickness value. The average thickness or strength is of little consequence since, like links in a chain, a column of media is only as strong as the weakest module. The minimum after forming thickness of any module, in any layer, of a filter layer should be no less than 15 mils. A minimum practical sheet thickness is necessary simply because of the uncertainties in: plastic creep, forming and the slow deformation of plastic materials over time. In addition to considering the after-forming thickness, specifying the number of sheets in the module should also be done. A useful field check as to the supply of adequate PVC material can be obtained by specifying and verification of a minimum dry weight (lb) per module. A number of engineers have specified minimum dry module weights ranging from 24 to 28 pounds per module. This measurement can be taken onsite during construction. A useful conversion factor for dry weight is: Material Properties Specifying the properties of individual PVC sheets used to fabricate the modules is critical to assuring quality control. Since PVC sheets are thermoplastic, their properties are affected by the ingredients used in formulating the sheets. Some of the critical tests for assessing properties of PVC sheets are given in Table 2.

Testing Load Perhaps the most significant area of misunderstanding in media specification is in the selection of a design test load for the bearing strength test. Designers often do not select an appropriate minimum module test load. The minimum load should reflect a practical test value that accounts for: concentrated loads, field conditions, fabrication variability, the weight of biomass, the weight of pumped transient water, and timing differences (accounting for a 2-hour test to 20-year life). Minimum test loads suggested are: A minimum load criteria based on media depth and the actual operating weight of the media should also be stated in the procurement specification. The operating load criteria has historically been based on the estimated live load for VF media, and not with the XF media that is most popular in today s design. In Mabbott s original work with VF media, the load associated with pumped water was considered minor, this may not be true with XF media. Mabbott used an overall factor of 4.0 to equate average live loads measured in the field, to a laboratory shortterm test load. This test factor is necessary to account for creep of plastic material that will occur over the 20-year life of the media versus the 2-hour test. To explain, Table 3 presents an estimation of test load criteria for a filter with 10 layers of media (20 feet deep). Column B gives the cumulative live load (module plus biomass load) using an average 200 lb (6.25 lb/ft 3 ) per module weight selected for design purposes. The traditional approach to determining the Photo 6: Heavy Biogrowth design minimum test load (psf) has been to multiply the live load by a test factor. For example, in Column E of Table 3, a test factor of 4 was used to determine the testing criteria of 700 psf for the 7 th layer of media using traditional methods. If vertical media was being used, then the true operating weight (including the weight of pumped water) would be only 16% greater than the live load because of the relatively short hydraulic retention time (2 min per 10 ft @ 1.2 gpm/ft 2 ). However with XF media a longer hydraulic retention time of approximately 7 minutes per 10 feet could cause considerably (56 percent) greater operating loads (Column F) then originally planned. The comparison shown in Table 3 is based on hydraulic retention times for media with fixed nozzle distribution. Rotary distribution with slow rotation may help to reduce the effect of added weight from transient water. However, regardless of the distribution method, design engineers need to take greater care in selecting a test load that accounts for the

Load Raio specific media type, application and weight of pumped water. 30 25 20 15 10 5 0 Facility A Facility B Facility C Facility A comparison of the estimated operating weight (Plastic Media + Biomass + Pumped Water) for the three facilities described earlier in Table 1 is presented in Figure 1. Figure 1 shows that media at Facility C had three times more load (weight in lbs) to carry than media at Facility A for each pound of plastic supplied. Figure 1 may even be load for XF to VF media (Facility B compared an understatement of the differences in operating to Facility C) since some studies have indicated there can be up to 50 percent more biomass accumulation on XF media then would occur with VF media. Specific Test Criteria Selection of media design criteria should depend upon location of the module in the tower. The bottom layer may be supported by grating or placed directly upon support beams. A beam test may be required to be sure the selected media is capable of supporting the module weight plus the weight of all of the layers of media above, the biota growth, and Photo 7: Media Before / After Collapse the water resting on its surface. This combined load must be carried at the maximum temperature for the planned life of the tower. Each intermediate layer must be load tested in contact with another module to be sure that it is capable of carrying the module weight plus all media above it plus biota plus water. The top layer has the least weight to support but must resist ultra violet light exposure, hydraulic erosion and foot traffic. The top layer is often a special composition designed for this service which is quite different from other layers. Additional Criteria and Cost A good engineering specification for plastic media should contain other criteria too numerous to mention in this paper. There are several sources for determining suitable criteria, including model specifications and recommendations from media suppliers. Albertson has prepared a draft generic specification for plastic media that should be evaluated. It is suggested that references given at the conclusion of this paper be considered before finalizing media specification. The question could be asked, if a restrictive engineering specification is used for procurement of plastic media, will this necessarily drive the cost of plastic modules to excessively high levels? Although the price of

plastic materials will vary there may only be a 10 to 20 percent increase in cost to assure modules of adequate strength. This is a minor cost when compared to the trauma and expense associated with a media collapse. Table 4 provides a comparison of the price quotes from 1974 for VF media to a recent price quotation on XF media every bit as beefy as media supplied in the 1970 s. As indicated by the price per cubic foot, media supplied in the late 1990 s with XF configuration and short-term testing may be as inexpensive as 20 years ago. These bargain prices may be due to improved forming methods, the availability and price of suitable PVC, and other items that do not effect media quality. To assure adequate strength, two media manufacturers (Brentwood Industries and Marley) have stated it is their practice to supply modules with stringent deflection criteria and with adequate test loads. With these standards and a good engineering specification the owner of a trickling filter can be assured of durable, long lasting plastic media. CONCLUSIONS The following conclusions can be made based on our present understanding of media strength. 1) The short-term test is an acceptable method of evaluating media strength with proper specification criteria and verification of short-term to long-term test results. 2) Suggested minimum bearing criteria for standard (27 to 30 ft 2 /ft 3 ) media should include: a) Detailed bearing strength test. - maximum deflection - test loads based on operating weight and media depth - minimum test loads regardless of depth - specific test criteria and test submittals - temperature consideration for the worst condition b) Minimum sheet thickness both before and after forming. c) Minimum weight for dry modules without biomass. d) Detailed listing of fabricated module properties including the number of sheets and methods for forming. e) Listing of suitable properties for PVC materials used in forming modules. 3) Care needs to be taken in selecting the media type and specification criteria to avoid media collapse. REFERENCES 1. Albertson, Orris E., (1997) Draft, Model Trickling Filter Media Specification Unpublished, Enviro Enterprises, Inc., Salt Lake City, UT. 2. Mabbott, Jean W., (1982) Structural Engineering of Plastic Media for Wastewater Treatment by Fixed Film Reactors, First International Conference on Fixed Film Biological processes, Kings Island, OH.