ENERGY EFFICIENT RETROFIT MEASURES GUIDE

Similar documents
Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Home Energy Assessment Rebate Guide

Michigan Energy Code Training and Implementation Program

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12

NB Power s Home Insulation Energy Savings Program as of August 1, PROGRAM INTRODUCTION PROGRAM OVERVIEW ELIGIBILITY...

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

RESEARCH HIGHLIGHT. Design and Construction of the Northern Sustainable House Arviat, Nunavut

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

Personal: Residential Grant Table for ecoenergy Retrofit

Boulder City NV Prepared by (Print Name) Signature Date

National Building Code Part 9 Energy Efficiency: Focus Paper to Assist in the Review of Proposed Changes

Can you Believe Energy Savings Forecasts

Airspace R-Values. Educational Overview. Revised 12/6/2016

Hardin County Planning and Development Commission

Corium Brick Rainscreen System Specifications

Michigan Energy Code Training and Implementation Program

2012 CLEAResult All rights reserved. Residential Energy Efficiency

Fenestration Energy Performance:

ORDINANCE NO. An ordinance amending Chapter 59, Dallas Energy Conservation Code, of the Dallas City

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

ADMINISTRATION CHAPTER 1

New Hampshire Residential Energy Code

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

Save NOW with a home retrofit grant - Save later on your energy bills.

Administrative Changes

Oregon High Performance Home Requirements

1) For the purpose of this Section, the term common space shall mean all spaces required to

Compliance Certificate

California HERO Program Residential Eligible Product List All Products

Case Study #9 Phoenix Rising

NEW HAMPSHIRE CODE OF ADMINISTRATIVE RULES

Building Design Data

ASHRAE 62.2: What s New in 2016

How do you install yours?

Building Codes and Ordinances ARC 227

CHAPTER 3: Modern Methods of Construction (MMC)

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Ontario s Building Code

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

INTERIOR ENVIRONMENT

Questar ThermWise Duct Technical Specifications

Low-Income Energy Savings Program. Program Guidelines

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera

Phase Two Change Proposal for the Next Edition of the Building Code: 2-CC-B POTENTIAL CHANGE TO ONTARIO S BUILDING CODE:

BUILDING PERMIT APPLICATION PACKAGE

3.1 Noise Overlay District

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise

BC BUILDING CODE ERRATA

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

November 10, 2015 Baltimore, MD. presented by

NW Natural Washington Residential, Contractor Install

Florida HERO Program Residential Eligible Product List All Products

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

WESTECK WINDOWS and DOORS

Commercial Building Envelope Program

Single Family Residence Building Permits

Inspection of New One- and Two- Family Dwellings

Alpen Windows - LEED Impact Analysis

2012 IECC Residential with State Adopted Changes

HERO Program Residential Eligible Product List California Residential Eligible Products... 2

BUILDING ENERGY CODES UNIVERSITY

Net Zero Building Enclosure Retrofits for Houses: An Analysis of Retrofit Strategies

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Chapter 1: Compliance

ACHIEVING HIGH-PERFORMANCE MULTI-UNIT RESIDENTIAL BUILDINGS: THE OPPORTUNITIES

RESEARCH HIGHLIGHT. Design Development of Low-Energy and Affordable Multi-Unit Residential Buildings

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

CRITERIA FOR TESTING IMPACT & NON IMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE

Building Guide. Colorado Chapter of the International Code Council

Passivhaus Project Documentation Wrexham Passivhaus

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

IRC 2012 Key Changes

ILLINOIS SPECIFIC AMENDMENTS TO THE IECC 2015 EDITION

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

Module number 6 provides an on-line, self-paced training seminar on energy efficiency and energy conservation for residential buildings.

Great Ocean Rd Ice Creamery

Renovation of a Detached Single-Family House into an Energy Efficient Low Energy House Larsen, Tine Steen; Maagaard, Steffen; Jensen, Rasmus Lund

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

One and Two Family Additions

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

NEW HOMES PROGRAM 2017 PROGRAM GUIDE

Margaret Batts Tobin Laboratory

Training Certification Categories

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

Advanced Ventilation for Residential applications FBC Res 2010.

Moisture Considerations for Insulated Building Assemblies

Moisture and temperature conditions in cold lofts and risk of mould growth

Carpenter Level 2 Rev. September 2017

ENERGY STAR for New Homes: Technical Specification - Ontario January 2011, revised September 2011

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Transcription:

ENERGY EFFICIENT RETROFIT MEASURES GUIDE ENERGY EFFICIENCY RETROFIT PROGRAM FOR LOW-INCOME HOUSEHOLDS CO-OP COMPONENT For nonprofit continuing housing cooperatives listed in the Québec Enterprise Register as lessors of social housing complexes.

Make the right choice! Doing renovations? Choose energy-efficient measures and you may be eligible for a rebate on the cost of the work under this Program. Eligibility 1. General condition Nonprofit continuing housing cooperatives that are listed in the Québec Enterprise Register as lessors of social housing complexes and that manage rental housing are eligible. 2. Specific conditions Buildings must be rental housing administered by co-ops of the type described above. Eligible buildings are those appearing on the list produced on the basis of the general condition set out above. Buildings must be equipped with permanent electric heating systems that are the main heating system and are used to heat the entire building. Eligible retrofit measures 4A Replacement of windows and patio doors (sliding glass doors) with ENERGY STAR certified models 4B Insulation upgrade main walls 4C Insulation upgrade roof with attic space 4D Insulation upgrade roof without attic space 4E Insulation upgrade foundation walls 4F Addition of heat recovery to mechanical ventilation (An engineer s opinion is required; co-ops interested in this measure must contact their federation, which in turn will contact Hydro-Québec.) The co-op has 12 months as of the date of the preretrofit assessment to have the work performed by a certified contractor and obtain the postretrofit assessment. Conditions applicable to retrofits differ from those applicable to general measures. Hydro-Québec has established a list of eligible products for measure 4A only; windows and patio doors must be replaced by models that are ENERGY STAR certified for the climate zone where the building is located. Applicable criteria are outlined in the Appendix. For each measure (except measure 4A), Hydro-Québec requires confirmation of the information provided in Appendix Section 2 by a member of one of the following professional governing bodies (the competent professional governing bodies ), who will affix his or her seal to the documents and recommend the measure: Ordre des technologues professionnels du Québec Ordre des ingénieurs du Québec Ordre des architectes du Québec 3. Eligibility period The work must be performed after April 30, 2007, and be completed before December 31, 2018. The request must be received within six months of the completion of the work. Important Read Specific Conditions of Participation in this guide for each type of measure carefully. For further information, visit our Web site: www.hydroquebec.com/org-comm/en. 2

Procedure 1. Have the following on hand Your organization number 2. Complete the entire Retrofit Measures form Section 1 General information Section 2 Information on work performed Section 3 Total rebate and customer s undertaking NOTE: Each building must be identified by its complete address and the building number must be indicated. 3. Enclose the following The Retrofit Measures form, duly completed and signed Appendix Section 2 of the Retrofit Measures form: - Measure 4A: copies of the invoices or validated by a member of one of the following professional governing bodies, as well as the corresponding ENERGY STAR data sheets. - Measures 4B, 4C, 4D, 4E and 4F: validated by a member of one of the following professional governing bodies, who will affix his or her seal to the documents: Ordre des technologues professionnels du Québec Ordre des ingénieurs du Québec Ordre des architectes du Québec NOTE: All information requested on the form must be provided. 4. Mail in the rebate application and supporting documents Hydro-Québec Soutien aux programmes Complexe Desjardins, tour Est, 24 e étage C. P. 10000, succ. Place Desjardins Montréal (Québec) H5B 1H7 Processing time Hydro-Québec will issue a cheque within 30 days of receiving your application, provided that the form is properly filled out and accompanied by the required supporting documents. 3

Completing the rebate application To obtain a rebate, you must enter the information required about the work performed. The rebate may not under any circumstances exceed the cost of products purchased or measures applied. The information provided in the Appendix Section 2 must be checked and signed by a member of a competent professional governing body, who must specify the nature of the work performed in each eligible building and the thermal resistance before and after the retrofit for each measure applied (except measure 4A). Specific Conditions of Participation Characteristics Hydro-Québec has not established a list of eligible products (except in the case of windows and patio doors) for the retrofit measures. However, Hydro-Québec does require that thermal resistance be confirmed before and after each retrofit measure (except measure 4A) by a member of a competent professional governing body. Eligible retrofit measures 4A Replacement of windows and patio doors (sliding glass doors) with ENERGY STAR certified models 4B Insulation upgrade main walls 4C Insulation upgrade roof with attic space 4D Insulation upgrade roof without attic space 4E Insulation upgrade foundation walls 4F Addition of heat recovery to mechanical ventilation (An engineer s opinion is required; co-ops interested in this measure must contact their federation, which in turn will contact Hydro-Québec.) 4

Using the tables to complete the rebate application Measure 4A Replacement of windows and patio doors with ENERGY STAR certified models Rebate per m 2 of net surface area replaced Zone 1 * Heating degree- day range Amount of rebate 2 3,500 6,000 $40/m 2 3 6,000 $50/m 2 1. Climate zone as defined in the ENERGY STAR qualifying criteria for residential doors, windows and skylights sold in Canada and not according to the Regulation respecting energy conservation in new buildings. Application The table above shows the amount of the rebate for improving thermal performance by replacing windows and patio doors separating a heated space from the outside air in a building in a municipality located in climate zone 2 or 3, as defined in the ENERGY STAR qualifying criteria for residential doors, windows and skylights sold in Canada ( eligible building ). The rebate amounts apply to all windows and all vertical sliding glass doors. Type of windows and patio doors Windows and patio doors installed in an eligible building must be ENERGY STAR certified for the climate zone where the building is located*. * The list of ENERGY STAR certified products for each climate zone (as defined in the ENERGY STAR qualifying criteria) is available on the Web site of the Office of Energy Efficiency, Natural Resources Canada. Products that are ENERGY STAR certified for zone 3 are automatically certified for zone 2, but not vice versa. The rebate application must list the brand name, model number and energy rating (ER) of each window and patio door used. This information is available from the product supplier and at www.energystar.gc.ca. 5

Net surface area Net surface area (m 2 ) of windows and patio doors replaced by high-efficiency models is measured between the exterior faces of the window or door frame and excludes any surface of any window or door for which a rebate is being claimed that does not meet the criteria specified in the preceding section. General comments Certain frames allow better vertical alignment of the glazing and the sash, such that the window is as close as possible to the interior surface of the wall. This ensures better thermal performance. As much as possible, windows should be selected to take this into consideration. In general, windows and patio doors with the highest ER offer the best thermal performance, particularly in buildings without air-conditioning and with identical window exposure on all four sides. ERs that meet the CSA A440.2 standard, Energy Performance of Windows and Other Fenestration Systems, are available for all ENERGY STAR certified windows. Solar heat gain: Low-emissivity (low-e) coatings minimize heat loss by radiation and heat gain by solar radiation. The characteristics of these coatings can be selected based on the orientation of the window or patio door to maximize performance. Building energy simulation models or the specifications in the CSA A440.3 standard can be used for this purpose. 6

Measure 4B Insulation upgrade main walls Rebate per m 2 of net surface area upgraded Final effective thermal resistance Initial effective thermal resistance RSI < 2.11 RSI = 2.11< 2.47 RSI = 2.47 2.66 RSI = 2.82 3.16 $17/m 2 RSI = 3.17 3.60 $21/m 2 $17/m 2 RSI = 3.61 4.04 $25/m 2 $21/m 2 $17/m 2 RSI 4.05 $32/m 2 $25/m 2 $21/m 2 The table above shows the amount of the rebate for improving the thermal resistance (reducing the thermal conductivity) of main walls separating a heated space from the outside air. The rebates apply to aboveground wall assemblies but not to walls or parts of walls in contact with the ground. Walls with slopes less than 60 to the horizontal are considered to be roofs, and roofs with slopes of 60 or more to the horizontal are considered to be walls. Effective thermal resistance Initial and final effective thermal resistance (preretrofit and postretrofit) of wall assemblies concerned must be determined using the method described in Appendix C of the Model National Energy Code of Canada for Houses 1997 (MNECH). Net surface area Net surface area (m 2 ) of the main walls whose thermal resistance is to be improved is measured horizontally between the interior faces of the exterior intersecting walls and vertically between the interior face of the roof assembly and the top of the foundation walls (or ground level). Net surface area excludes any surface not insulated to the final effective thermal resistance for which a rebate is being claimed (specifically areas adjacent to floors that cannot be insulated to improve effective thermal resistance as indicated) and openings created by doors, windows or other glazed surfaces, measured from the exterior faces of their frames. General comments The wall components and assemblies whose thermal resistance is to be improved must be designed and built in accordance with good practice to resist or adjust to all environmental loads to which they may be exposed, particularly temperature, water vapour, wind and precipitation levels, differences and fluctuations. To minimize the risk of deterioration of materials, particular attention should be paid to the following: Measures to prevent condensation in the walls, including humidity control in the interior spaces of the building Measures to prevent water infiltration as a result of precipitation, notably flashings and sheathing membranes or materials Measures to promote evaporation of moisture that could accumulate in the walls and cause damage Use of low water-vapour permeance and low air permeance materials in walls 7

Measure 4C Insulation upgrade roof with attic Rebate per m 2 of net surface area upgraded Final effective thermal resistance Initial effective thermal resistance RSI < 2.29 RSI = 2.29 3.51 RSI = 3.52 4.40 RSI = 3.52 4.39 $8/m 2 RSI = 4.40 5.63 $10/m 2 $10/m 2 RSI = 5.64 6.68 $11/m 2 $10/m 2 $10/m 2 RSI 6.69 $11/m 2 $10/m 2 $10/m 2 The table above shows the amount of the rebate for improving the thermal resistance (reducing the thermal conductivity) of roof assemblies separating a heated space from the outside air. The rebates apply in particular to roofs with vented attics where there is sufficient space to install thermal insulation; generally, the roof and the ceiling are separate assemblies. A ceiling is deemed to be part of the adjacent roof, and the ceiling, the roof or both the roof and ceiling in this roof/ceiling assembly may be insulated in accordance with good practice. The table generally applies to roof assemblies where the ceiling is insulated and there is a space ventilated to the outside in accordance with good practice between the insulation and the roof sheathing. Walls with slopes less than 60 to the horizontal are considered roofs, and roofs with slopes of 60 or more to the horizontal are considered walls. Effective thermal resistance Initial and final effective thermal resistance (preretrofit and postretrofit) of the roof assemblies concerned must be determined using the method described in Appendix C of the Model National Energy Code of Canada for Houses 1997 (MNECH). Net surface area Net surface area (m 2 ) of a roof assembly whose thermal resistance is to be improved is measured the length and width of the insulation between the interior faces of intersecting exterior walls and excludes any surface not insulated to the final effective thermal resistance for which a rebate is being claimed and openings created by skylights, chimneys or other large elements of this type. General comments Roof components and assemblies whose thermal resistance is to be improved must be designed and built in accordance with good practice to resist or adjust to all environmental loads to which they may be exposed, particularly temperature, water vapour, wind and precipitation levels, differences and fluctuations and accumulations of snow, ice and water. To minimize the risk of deterioration of materials, particular attention must be paid to the following: Measures to prevent condensation in roof assemblies (including humidity control in the interior spaces of the building) and to ventilate to the outside the space between the insulation and the roof sheathing Measures (with respect to roof components, flashings, junctions and penetrations in particular) to prevent water infiltration as a result of precipitation and accumulation of snow, ice or water The structural strength of roof assembly frames, to ensure tolerance of potential snow, ice and water loads 8

Measure 4D Insulation upgrade roof without attic Rebate per m 2 of net surface area upgraded Final effective thermal resistance Initial effective thermal resistance RSI < 0.88 RSI = 0.88 1.75 RSI = 1.76 3.52 RSI = 1.76 2.10 $9/m 2 RSI = 2.11 2.99 $17/m 2 $9/m 2 RSI = 3.00 3.86 $24/m 2 $17/m 2 $9/m 2 RSI 3.87 $31/m 2 $24/m 2 $17/m 2 The table above shows the amount of the rebate for improving the thermal resistance (reducing the thermal conductivity) of roof assemblies separating a heated space from the outside air. The rebates apply in particular to roof assemblies without attics ventilated to the outside where the thermal insulation is not between the roof framing members but rather above them, as is the case with heavy timber or concrete roof decks with rigid insulation. The rebates also apply to roof assemblies with limited space for satisfactory installation of insulation, particularly those where the frame consists of parallel joists with rigid insulation installed above them. A ceiling is deemed to be part of the adjacent roof, and the ceiling, the roof or both the roof and ceiling in this roof/ceiling assembly may be insulated in accordance with good practice. The table generally applies to roof assemblies where the roof is insulated in accordance with good practice. Walls with slopes less than 60 to the horizontal are considered to be roofs, and roofs with slopes of 60 or more to the horizontal are considered to be walls. Effective thermal resistance Initial and final effective thermal resistance (preretrofit and postretrofit) of the roof assemblies concerned must be determined using the method described in Appendix C of the Model National Energy Code of Canada for Houses 1997 (MNECH). Net surface area Net surface area (m 2 ) of a roof assembly whose thermal resistance is to be improved is measured the length and width of the insulation between the interior faces of intersecting exterior walls and excludes any surface not insulated to the final effective thermal resistance for which a rebate is being claimed and openings created by skylights, chimneys or other large elements of this type. General comments Roof components and assemblies whose thermal resistance is to be improved must be designed and built in accordance with good practice to resist or adjust to all environmental loads to which they may be exposed, particularly temperature, water vapour, wind and precipitation levels, differences and fluctuations and accumulations of snow, ice and water. To minimize the risk of deterioration of materials, particular attention must be paid to the following: Measures (with respect to roof components, flashings, junctions and penetrations in particular) to prevent water infiltration as a result of precipitation and accumulation of snow, ice or water The structural strength of roof assembly frames, to ensure tolerance of potential snow, ice and water loads 9

Measure 4E Insulation upgrade foundation walls Rebate per m 2 of net surface area upgraded Initial effective thermal resistance Final effective thermal resistance RSI < 1.23 600 mm below ground RSI < 1.23 full surface RSI = 1.23 2.11 600 mm below ground RSI = 2.11 2.63 full surface $22/m 2 $22/m 2 $7/m 2 RSI 2.64 full surface $27/m 2 $27/m 2 $29/m 2 The table above shows the amount of the rebate for improving the thermal resistance (reducing the thermal conductivity) of foundation wall assemblies separating a habitable heated basement space with a minimum clear height of 6 ft. 4 in. (1.95 m) from exposed ground or outside air. Effective thermal resistance Initial and final effective thermal resistance (preretrofit and postretrofit) of the assemblies concerned must be determined using the method described in Appendix C of the Model National Energy Code of Canada for Houses 1997 (MNECH). Net surface area Net surface area (m 2 ) of a foundation wall assembly whose thermal resistance is to be improved is measured horizontally between the interior faces of adjacent walls in contact with the ground and vertically between the top of the foundation wall and the surface of the intersecting floor in contact with the ground. Net surface area excludes any surface not insulated to the final effective thermal resistance for which a rebate is being claimed and openings created by doors, windows or other glazed surfaces, measured from the exterior face of their frames. General comments Wall assemblies and components whose thermal resistance is to be improved must be designed and built in accordance with good practice to resist or adjust to all environmental loads to which they may be exposed, particularly temperature, water vapour, wind, precipitation and ground moisture levels, differences and fluctuations. To minimize the risk of deterioration of materials, particular attention must be paid to the following: Measures to prevent condensation in the foundation walls, including humidity control in the interior spaces of the building Measures to prevent water infiltration as a result of precipitation Measures to prevent walls in contact with the ground from absorbing ground moisture Measures to promote evaporation of moisture that could accumulate in the walls and cause damage Use of low water-vapour permeance and low air permeance materials in walls 10

Measure 4F Add heat recovery to mechanical ventilation (see specific conditions) Rebate per unit of reference airflow Type of heat recovery Initial condition Balanced mechanical ventilation system designed for continuous operation Type I $15 per L/s of reference airflow Type II $20 per L/s of reference airflow The table above shows the amount of the rebate for adding heat recovery to one or more balanced mechanical ventilation systems in a building in order to recover sensible heat from the exhaust air and transfer it to supply air entering the building, thus reducing the building s electricity consumption. To qualify for a rebate, all heat recovered from the exhaust air must be transferred to a fresh air supply stream of equivalent flow (± 10%) and all spaces involved must be initially heated entirely by electricity. The building s balanced mechanical ventilation system, including its exhaust and supply system, must be designed (before or after the retrofit) for continuous operation. Type of heat recovery For independent systems serving a single dwelling and systems for which test data and results (test method below) are known, the sensible heat recovery efficiency must be between 50% and 70% for type I heat recovery and at least 70% for type II heat recovery. The sensible recovery efficiency of heat recovery ventilator (HRV) systems must be determined at an outdoor temperature of 0 C and a rated airflow equivalent to the operating airflow of the balanced mechanical HRV system. The airflow thus measured is the recovered-heat airflow. Thermal performance tests must be conducted in accordance with the CAN/CSA C439 standard, Standard Laboratory Methods of Test for Rating the Performance of Heat/Energy-Recovery Ventilators. For other systems, net heat recovery efficiency must be between 50% and 70% for type I heat recovery and more than 70% for type II heat recovery. Net sensible recovery efficiency of these systems must be established in accordance with the ARI 1060 standard, Performance Rating of Air-to-Air Heat Exchangers for Energy Recovery Ventilation Equipment, at a rated airflow equivalent to the operating airflow of the balanced mechanical HRV system. The airflow thus measured is the recovered-heat airflow. Heat recovery systems and related ducts must be located within the heated building envelope whenever possible. If not, or if outdoor exposure is required, the manufacturer s instructions must cover such usage and particular attention must be paid to airtightness, watertightness, water vapour transfer, thermal insulation and weather protection of the equipment and the air ducts running to it from inside the heated envelope, so that all measures are taken in accordance with good practice to maintain the anticipated efficiency. 11

Reference airflow The reference airflow (L/s) is the smallest of the following three values: (7.5 x n1 + 7.5 x n2) + COM where n1 = total number of units in the building n2 = total number of rooms in the building COM = (0.25 x C1) + C2 where C1 = floor area (m 2 ) of common corridors, service rooms and storage areas (0 in the case of a building with a single unit) C2 = floor area (m 2 ) of common rooms (0 in the case of a building with a single unit) Mean design winter ventilation rate (L/s) of the balanced mechanical ventilation system Mean airflow during the heating season of the balanced mechanical HRV system or systems; this is the mean recovered-heat airflow. General comments A building s mechanical ventilation needs (rate and distribution) must be established in accordance with good practice. Mechanical ventilation systems and any measuring systems required to maintain net overpressure and underpressure within acceptable limits must also be designed and built in accordance with good practice. Where real or perceived mechanical ventilation needs are minimal and the mean ventilation rate would be significantly reduced in the heating season, the payback period for adding heat recovery to the mechanical ventilation system may be as long or longer than the service life of the equipment. This may be particularly true in two-storey houses where the air leakage rate of the envelope is more than four or five air changes per hour (ACHs) at 50 Pa, which is the average leakage rate of homes built before 1985: with real average mechanical ventilation needs so low, the mean ventilation rate would be significantly reduced during the heating season. A maintenance program should be established for mechanical ventilation systems, particularly HRV systems. 12

Applicable warranties Warranties on products installed are those offered by manufacturers and installers (such as those covering manufacturing defects that affect safety or performance). Hydro-Québec shall not be held liable for any damage or harm arising from the installation or use of products or from the work performed. Verifying applications You must unconditionally agree to submit the necessary documents or to give a guided tour of your premises within twelve months of the date of completion of the work to ensure compliance with Program conditions. Hydro-Québec can reduce payments for any overpayments to the Organization under one or more previous payments. If the overpayments to the Organization exceed the amount owed by Hydro-Québec, the company can demand repayment of the amounts owed to it within 30 days. If you fail to comply with Program conditions, you must repay any rebates received from Hydro-Québec. Rebates apply only to eligible retrofit measures. Eligible measures and rebate amounts are shown in the tables of this guide. Failure to pay Hydro-Québec Hydro-Québec may deduct any amount you owe from the rebate to be paid. The rebate will be paid within 30 days of Hydro-Québec s receipt of your application, provided the proofs of purchase and installation meet requirements. Link to other programs Any work for which Hydro-Québec has paid a rebate under the Energy Efficiency Retrofit Program for Low-Income Households Co-op Component shall be ineligible for any other rebate or financial assistance under any other Hydro-Québec program. Supporting documents to be submitted You must complete and submit the Appendix Section 2 of the Retrofit Measures form, which must be checked and signed by a member of a competent professional governing body (see specific conditions). Proofs of purchase and installation to be submitted on request You must retain all invoices related to the work covered by the rebate application for twelve months after completion of the work and submit them on request. The invoices must include the following information: Name of customer Nature of work Description of materials used Date work was done Total price paid Corresponding ENERGY STAR data sheets (measure 4A) Changes to specific conditions Hydro-Québec reserves the right to change without prior notice the specific conditions of participation in the Energy Efficiency Retrofit Program for Low-Income Households Co-op Component. However, the specific Program conditions will continue to apply to applications approved by a professional prior to the effective date of the changes. Installation standards You are solely responsible for the selection, purchase and installation of materials and for the work performed. You are solely responsible for compliance with the requirements herein as well as those decreed by regulatory authorities, recommended by manufacturers or considered to be good practice, particularly those set forth in applicable codes and standards or in applicable directives, guides or manuals published by agencies such as the NRCC or the CMHC. Environment It is up to you to recycle or dispose of any products replaced under this Program. 13

The Energy Efficiency Retrofit Program for Low-Income Households Co-op Component covers other products that can help reduce energy-consumption and save even more money. Inquire about them. For further details, go to www.hydroquebec.com/org-comm/en or call 514 ÉNERGIE (363-7443) 1 800 ÉNERGIE Montréal area elsewehere in Québec Hydro-Québec Coordinated by Communication avec la clientèle for Direction Approvisionnement en électricité July 2015 Ce document est également publié en français. 2015G1311A 100%