Agilent 4339B/4349B High Resistance Meters Technical Overview

Similar documents
Agilent 8490G Coaxial Attenuators

Advanced Test Equipment Rentals ATEC (2832)

Agilent CSA Spectrum Analyzer N1996A

Fluke Oscilloscope Calibration Solutions. Helping you measure up to the highest standards

Friendly User Interface. Simply AUTO Mode. Support the Universal input voltage

7700 TEST KIT OPERATIONS MANUAL

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

Agilent 16047D Test Fixture

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)

5Agilent 81110A/ 11A Performance Test

RT mA, Ultra-Low Noise, Ultra-Fast CMOS LDO Regulator. Features. General Description. Applications. Ordering Information RT9193-

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

Agilent 16034E Test Fixture

SIWAREX FTC-B Weighing Module for Belt Scales Set-up of SIWAREX FTC with SIWATOOL FTC_B

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

PCIEC/PCIE PCIEC EC-EC-AP/PCIE F-D-RA

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

NARROW PITCH (0.4mm) CONNECTORS P4S SERIES

Ruby Installation Manual

ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)

Single Pulse Resistance Welder Instruction Pamphlet CD125SP High Accuracy CD Welder

Sensor unit MC2 for toxic gases and oxygen with analog output

Pressure transducers DMU 02 Vario (flush)

Compact flue gas analyser: testo 300 M-I

Digital relative humidity & temperature sensor AM2301

The I-7531 CAN Repeater

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

AC/DC Converter SLH40 Series

Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification.

HOBO Plug Load Logger (UX ) Manual

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

HND-F. Hand-held Humidity Precision Measuring Unit % weight moisture % relative humidity. starting with ± 0.1%

Model: LoLander Series Truck Scale Model: LL FT Model: LL FT Installation, Set-Up and Operation Manual

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Combustion Laboratory Unit C492

Brochure. Equator gauging systems

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

Fine particle measuring system

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

DESIGN VERIFICATION TEST REPORT ERCDA SS-TD-TU. Mated with ERF L-DV-L

RoHS Compliant (6/6) according to Directive 2002/95/EC when ordered with 100% Sn solder.

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

nicrom e l e c t r o n i c

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

DATA SHEET Metal Element Current Sensing Chip Resistor CLS Series

RT A, Ultra-Low Dropout, Ultra-Fast CMOS LDO Regulator. General Description. Features. Applications. Ordering Information. Marking Information

PLCC Sockets Through Hole - M43 Series

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

Applications. Capacitance Code (pf) Tolerance

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

Military Attenuator Module

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Data Logging Solutions from Lascar Electronics

Contents. MY-Series 2 Placement Machines 4 Options 6 Upgrades 14. TP-Series 22 Upgrades 24

Welding Force Calibration Transmitter

SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output no

PD662 Loop-Powered Meter Instruction Manual

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

TC-L32C5L LCD TV. Model No. TC-L32C5H. Panasonic Corporation Unauthorized copying and distribution is a violation of law.

Model: LI55 DataView Level Controller Instruction Manual

Agilent Technologies U7238A MIPI D-PHY Compliance Test Software for Infiniium Oscilloscopes

Rothe Development, Inc. Houston Texas Metrology Services Division

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

Instruction Manual HI Portable ph/ec/tds/ C Meters

Solid Tantalum Chip Capacitors. Shenzhen Sunlord Electronics Co., Ltd

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.

WLC60 Heavy Duty LED Light

LITE-ON TECHNOLOGY CORPORATION

ULTRA-CUT XT SYSTEMS THE NEXT GENERATION OF HIGH PRECISION PLASMA CUTTING. We Bring Intelligence to the Table. Victor Thermal Dynamics introduces

High Reliability Hyperboloid Contacts

Tantalum Wet Electrolytic Capacitor

2% & (+ 2% PSI.

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Explore the future of osmometry. Multi-Sample Micro-Osmometer

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

xs 4S/5SManual 1.4 en

SpeedExtractor E-916 / E-914 Technical data sheet

COATING THICKNESS MEASURING

Tantalum and Niobium Technology Roadmap

Using the PPM2 Portable Trace Moisture Transmitter

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ICP Expert software. Technical Overview. Introduction

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

Model BF 720 Incubators Avantgarde.Line with forced convection

Reference Only. 2.Part Numbering (ex) NF Z 5B BW 2R9 L N 1 0 L

Table of Contents. Installation 2-10 Leveler legs... 2 Controller... 4 Dip-switch Configurations. 5 Wire Harness Installation.. 7

Extended-Frequency SMA Connectors

Calibration/Validation Guidance For Miller Welding Equipment

New Low Profile Low ESL Multi-Anode Mirror Tantalum Capacitor

Feb12 Rev D

X-RAY FOOD INSPECTION SYSTEMS DYMOND X-RAY INSPECTION SYSTEM

We are at your service around the globe!

Implantable Microelectronic Devices

GAS 3050P NDIR FLUE GAS

Transcription:

Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance Measurements For precision bench-top applications, the 1-channel 4339B is the premier solution for accurate high resistance and low current tests. For high resistance testing in manufacturing environments, the 4349B offers simultaneous 4-channel high resistance measurements for increased test throughput. Satisfy Your Needs for... High quality results High confidence testing with contact check function Remove parasitics with error correction Consistent data with 0.6% basic accuracy Compensation for handler contact chattering with trigger delay Versatile measurements Select from four test parameters Use a variety of test fixtures and accessories Perform a charge-measuredischarge sequence with the test sequence program function Save and recall up to ten measurement setups High test throughput: 4349B 9.5 ms measurements 4-channels for multiple DUTs 4-channel simultaneous testing Fast contact checking: 2 ms/ measurement GPIB and handler interfaces Ideal for high volume capacitor testing

Display: LCD with back-light. Displays measurement values. Instrument slates and comparator results. Test sequence program: Controls a series of resistance measurements. (Charge-measure-discharge) Open: Compensate leakage current and capacitance in test fixtures and cables. Measurement parameter: Select the right parameter for the measurement. Comparator: Select values for high, in, and low testing. Save/Recall: Store and retrieve up to 10 measurement states. Contact check: Verifies reliability of capacitor test connections. Agilent 4349B 4-channel high resistance meter Key parameters and specifications Agilent 4339B Agilent 4349B Test channels 1 2ch, Option 4349B-001 4ch, Option 4349B-700 Test voltage(vdc) 0.1 to 1000 Requires external power source Measurement parameters R, I, pv, ps R, I Measurement range (Ω) 10 3 to 1.6x10 16 10 3 to 10 15 Basic accuracy 0.6% 2% Display resolution 3 / 4 / 5 digits 3 / 4 / 5 digits Measurement time 10 ms/30 ms/390 ms 9.5 ms/28 ms/98 ms/397 ms 2

High quality measurements with flexible hardware Resolve data to 5 digits (3, 4, or 5 digits selectable) Make precise measurements with 0.6% basic accuracy Verify DUT performance at the exact voltage rating Reliable and safety measurements with Agilent 16339A component test fixture 4339B solutions for high voltage material testing Resistivity mathematics built-in: surface and volume Agilent 16008B resistivity cell for solid samples Easy measurements with test sequence program function (controls charge-measuredischarge sequence) Customize your fixture cabling with the Agilent 16117C test leads System features you need to be successful Maximize accuracy with error correction Test capacitor contact failure with contact check function Automate testing with GPIB interface Reduce ground-loops with isolated handler interface Pass/Fail testing with comparator function (high/in/low) Capacitor evaluation with the 4349B Optimize capacitor Vdc rating tests Increase throughput four times with 4-channels Improve reliability with contact check Get low noise results with Agilent 16117E test lead 3

Resistance RM (Ω) Current IM (A) Resistance measurement Accuracy Current measurement Accuracy Test voltage setting Vs (V) V o = 0.1 V @ V s 200 V = 0.5 V @ V s > 200 Figure1. Conversion diagram Table 1. Agilent 4339B measurement accuracy (±% of reading) Specifications Measurement Accuracy Agilent 4339B test conditions*: 1. Warm up time: 30 minutes 2. Ambient temperature: 23 C ± 5 C 3. Test cable length: 1.5 meters 4. Open error correction performed 5. Long measurement time setting 6. Contact check: off Accuracy parameters: Rm: Measured resistance value in W Im: Measured current value in amperes Vs: Source voltage in volts Vo: 0.1 V@Vs 200 V, 0.5 V@Vs > 200 V Accuracy example: To determine the accuracy of a measurement use Figure 1, Conversion diagram. For example: determine the accuracy of a 5 MΩ (= 5 x 10 6 Ω) measurement at 50 Vdc. Rm = 5 x 10 6 Ω Vs = 50 V The intersection of Rm running parallel to the 10 6 Ω diagonal line intersects the vertical Vs line at the second row from the bottom of the diagram. Moving horizontally across to Table 1, the following equation is found: 100 Vo + (2.5 x 10-7 x Rm) 0.5 + Vs Entering the values for Rm, Vo, and Vs yields an accuracy of ±0.725%. 4

Resistance RM (Ω) Current IM (A) Resistance measurement accuracy Current measurement accuracy Test voltage setting Vs (V) Figure 2. Conversion diagram Table 2. Agilent 4349B measurement accuracy (±% of reading) Agilent 4349B test conditions 1 : 1. Warm up time: 30 minutes 2. Ambient temperature: 23 C ± 5 C 3. Test cable length: 1.5 meters 4. Open error correction performed 5. 30 ms measurement time setting Accuracy parameters: Rm: Measured resistance value in ohms Im: Measured current value in amperes External power supply parameters: Vs: Source voltage in volts Vo: Source offset voltage in Volts Av: Voltage accuracy 1. Other test condition data available in the operation manual. 5

Other Specifications Measurement parameters/ranges Parameter Agilent 4339B Range R (dc resistance) 10 3 Ω to 1.6 x 10 16 Ω I (dc current) 60 fa to 100 µa ps (surface Refer to operation resistivity) manual pv (volume Refer to operation resistivity) manual Agilent 4349B R (dc resistance) 10 3 Ω to 10 15 Ω I (dc current) 1 pa to 100 µa Measurement conditions and functions DC test voltage (4339B): 0 V to 1000 V, 0.1 V steps @ V 200V, 1.0 V steps @ V > 200 V DC test voltage (Agilent 4349B): None supplied, use external power supplies and voltage data entry for resistance measurements. Maximum of 5000 V input and 5 digit numerical entry. Max current (Agilent 4339B): 10 ma @ 100 V, 5 ma @ 250 V, 2 ma @ 500 V, 1 ma @ 1 kv Number of test channels: 4339B: 1 channel, 4349B: Option 4349B-700:4 ch Option 4349B-001:2 ch Ranging: Auto and hold Trigger: Internal, manual, and external Delay time (trigger): 0 ms to 9999 ms in 1 ms steps Test cable lengths: 2 meters maximum Measurement time (typical): 4339B: 10 ms / 30 ms / 390 ms 4349B: 9.5 ms / 28 ms / 98 ms / 397 ms Other instrument functions Error correction: Open (removes errors due to parasitics). Comparator: High, in, and low for each of the test parameters. Save/Recall: 10 instrument states from non-volatile memory. Contact check: Detects contact failure for capacitive devices (2 ms). GPIB: Agilent s implementation of IEEE 488 for control and data. Handler interface: Negative logic and isolated. Signals are high/in/low, no contact, EOM, index, alarm, keylock, ext. trigger. Physical characteristics Power: 90 132 Vac or 198 264 Vac. 47 Hz 66 Hz. 45 VA (typical) Operating temperature/humidity: 0 45 C/ 95% RH @ 40 C. Dimensions: 320(W) x 100(H) x 450(D) mm. Weight: 6.5 kg (typical). 6

Test Fixtures/Accessories Agilent 16339A component test fixture For manual high voltage testing of descrete components. For 4339B only. Option 16117B-003 Agilent 16117C low noise test leads Interlock, voltage source, and current sensing cables. Terminations are threaded triaxial, standard BNC, and bare interlock pair. Female BNC and triaxial connectors are included. For 4339B only. Agilent 16008B resistivity cell For resistivity measurements of dry sheet samples. Upper electrode is spring loaded to apply pressure. Surface and volume measurements. Installed with 50 mm diameter electrode. Option 16008B-001 adds 26 mm/76 mm diameter electrodes. Option 16008B-002 adds 26 mm diameter electrode. For 4339B only. Maximum applied voltage: 1000 Vdc. Sheet thickness range: 10 µm to 100 mm. Option 16117B-001 Option 16117B-002 Agilent 16117B low noise test leads Wide jaw clip leads for 4339B. 1 meter cable. Applicable measurement range: 1 x 10 11 Ω (typical). For 4339B only. Option 16117B-001 adds a pair of pin-type probes. Option 16117B-002 adds a pair of socket adapters for connecting to a custom made fixture. Option 16117B-003 adds a pair of alligator clips. Agilent 16118A tweezer test fixture Tweezer test fixture for easy testing for chip components. Maximum applied voltage: 100 Vdc. Applicable measurement range: 1 x 10 11 Ω (typical). For 4339B only. Agilent 16117E low noise test lead Male-triaxial to male-triaxial connectors. One meter cable. One femaletriaxial connector included. For 4349B only. Agilent 16064B LED Display/Trigger box Displays comparator status. Cable length 1.5 meters. Manual external trigger. For 4339B only. 7

b Ordering Information = Choose ONE and ONLY one q = Choose any combination Agilent 4339B High Resistance Meter 1 Furnished accessories: shunt connector Documentation options 2 q Option 4339B-ABA q Option 4339B-ABD q Option 4339B-ABJ q Option 4339B-ABE q Option 4339B-0BW Add specified quantities of English manual Add specified quantities of German manual Add specified quantities of Japanese manual Add specified quantities of Spanish manual Add service documentation, assembly level Agilent 4339B test fixtures and accessories Agilent 16008B Resistivity cell (50 mm diameter electrode) q Option 16008B-001 Add 26 mm and 76 mm diameter electrodes q Option 16008B-002 Add 26 mm diameter electrode Agilent 16117B Low noise test leads q Option 16117B-001 Add pin probes q Option 16117B-002 Add soldering sockets q Option 16117B-003 Add alligator clips 3 Agilent 16117C Agilent 16118A Agilent 16064B Agilent 16339A Low noise test leads Tweezer test fixture LED display/trigger box Component test fixture Agilent 4349B High Resistance Meter 4 Test channel options 5 Option 4349B-700 4-channels Option 4349B-001 2-channels Ripple 1 mvrms (50/60 Hz) Wide band noise 5 µvrms/ Hz (50 Hz) Switching noise 50 mvrms (100 khz) Agilent 4349B high resistance meter 6 Documentation options q Option 4349B-ABA Add specified quantities of English manual q Option 4349B-ABJ Add specified quantities of Japanese manual q Option 4349B-0BW Add service documentation, assembly level Cabinet options 7 q Option 4349B-1CM Rack mount kit q Option 4349B-1CN Front handle kit Certification option q Option 4349B-A6J ANSI Z540 compliant calibration Agilent 4349B Test Fixtures and Accessories Agilent 16117E Low noise test lead Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. By internet, phone, or fax, get assistance with all your test & measurement needs Online Assistance: Agilent Email Updates www.agilent.com/find/assist www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc., 1996, 2000, 2002, 2003, 2004 Printed in USA, February 4, 2004 5964-6182E 1. Test fixture is not furnished with the 4339B. 2. Manual is not furnished with the 4339B. 3. The alligator clips are not furnished as standard. 4. External power source required for resistance measurements. Recommendation for external power source for measurement of 1 GΩ sample @ 100Vdc with accuracy = ±10%. 5. 2-channels to 4-channels upgrade not available. 6. Manual is not furnished as standard. 7. Rack flange and handle kit are not compatible.