Installation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex

Similar documents
Ovalizing Flexible Liners

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro

DuraFlex AL. Installation Instructions

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval.

Z-Vent Model SVE Series III

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

INSTALLATION INSTRUCTIONS

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

Concentric Vent/Air System Supplement

Air flue duct for use with ecotec boilers

ROOF MOUNT KIT OWNERS MANUAL

Universal Tactical Light

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

7 PIECE TUBE FLARING KIT

Installation Instructions. Air-Cooled Chimney for Isokern Fireplaces

Flexible Chimney Liners

Owner s Manual & Safety Instructions

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

VISE MOUNTED. Model 97359

Troubleshooting Guide 9702 Series

Installation instructions

Installation and Maintenance Instructions For. Installation and Maintenance Instructions For

4 rotary milling table

Installation Guide April 2017

BlazeMaster Fire Protection Fittings Threaded

DRYWALL DOLLY 900 LB. CAPACITY

SUBMITTAL RECORD. Material Selection FLUE (INNER WALL) CASING (OUTER WALL) GALVALUME

Installation Instructions

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

Installation and Operation Manual

LOAD RAMP 1000 LB. CAPACITY

Drag Chain Conveyor Installation and Operation Manual

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

SI T T FST

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

Simpson Dura-Vent Engineered Excellence

92831 TEL: (714) FAX:

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

Owner s Manual Shelf Lip Accessory

Radon Vent Pipe System. Labeling Performance Indicators

Absco Premier Garden Shed Assembly Instructions Model: 30232G

Owner s Manual & Safety Instructions

INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000

METALLIC CHIMNEY LINER SYSTEM Single Wall Construction Rigid Chimney Liner. Installation Instructions. Models

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

SELF-REGULATING ROOF HEAT CABLE. Installation Guide WS-SRIM V2.0

Conergy SolarFamulus II

the heart of a warm home

RAPiD VEHICLE SAFE. Owner s Manual. Instructional videos for Hornady Security products are available at hornady.com. With patented RFID technology.

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

LAHAINA. Lahaina Showerspa Model #1030 Installation Instructions

Fire Barrier Duct Wrap 615+

MODEL IPIC SERIES 4G GREASE DUCT

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

Lionel #213 Lift Bridge Owner s Manual /02

Installation Manual. LIFETIME LIMITED WARRANTY Warranty applies to select Residential faucets only. Pressure Balance Valve TSPVR & TSPTR

HT210 HAY TEDDER PARTS MANUAL SECTION 16

Stainless steel rolling cabinet

Gun Safe 6720F / 6740F. Operation & Installation Guide. FIRE 30minutes /1100ºF RATED THEFT. Manual # M

Sorrento Stone Surrounds

O B R O U N D G R E A S E D U C T

Owner s Manual & Safety Instructions

Bottom Hinged Flood Barrier Operation & Maintenance Manual

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

BIN LINER INSTALLATION MANUAL IMPORTANT!

NVD-40 NEAR VERTICAL DRUM LIFTER INSTRUCTION MANUAL

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

FLEX SHOWER DOOR INSTALLATION INSTRUCTIONS. For more information on DreamLine TM Shower Doors please visit

FLUE KIT INSTALLATION MANUAL

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

SERIES G1A, G1B & G1C SLIDE GATES

MODULAR ACOUSTIC FENCING INSTALLATION GUIDE

TILE TILE

QUATRA SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Owner s Manual & Safety Instructions

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

RHE3 Dock Leveler Installation Manual

SHOWER & TUB/SHOWER INSTALLATION

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

FLEX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Installation. Basic Rack Power Distribution Units AP9560 AP9561

HIGH EFFICIENCY POSITIVE PRESSURE VENTING SYSTEMS FOR CONDENSING APPLIANCES, CATEGORIES II, III AND IV Single & Double Wall Construction

Rediflow Concrete Gas Flue System

Original Scandinavian rainwater system

PIPE

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

RACK HAT / STRIP DOOR

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Universal Trocar Stability Sleeve. Reprocessed Device for Single Use.

INSTALLATION MANUAL. Guardian Series. QSUS 18 x 40. Manual

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

Strong-Seal Sealant Specification, a permanent method of sealing the interior of the chimney and casting in manholes and catch basins.

Pedestrian Flood Door

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products

Transcription:

Installation Instructions PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances PolyPro Flex

A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT POLYPRO BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. important Throughout this manual you will see special attention boxes intended to supplement the instructions and make special notice of potential hazards. In the judgement of M&G DuraVent, these categories mean: Warning Indicates a condition or hazard which may cause severe personal injury, death or major property damage. Caution Indicates a condition or hazard which will or can cause minor personal injury or property damage. Warning Risk of carbon monoxide poisoning or fire due to joint separation or pipe breakage. Examine all components for possible shipping damage prior to installation; Read all instructions before beginning the installation and follow these instructions exactly as written. Proper joint assembly is essential for a safe installation. Check the integrity of ALL joints upon completion of assembly This venting system must be free to expand and contract under normal operation. Assure unrestricted vent movement where required through walls, ceilings and roof penetrations. This venting system must be supported in accordance with these instructions. Do not mix pipe, fittings, or joining methods from different vent system manufacturers. Do not use adhesives of any kind with this venting system. Keep these instructions for future reference. Dear Customer, Installer, or End User: We welcome any comments regarding matters pertaining to our DuraVent products. We welcome any ideas, input or complaints to help improve our product offering. Send your emails to: president@duravent.com If you are searching for tech support or product information, please phone us at 800-835-4429. Or email us at: techsupport@duravent.com PolyPro is one of M&G DuraVent's GreenVent line of products. 2

PolyPro Flex Gas Vent System For the most up-to-date installation instructions, see www.duravent.com CONTENTS Application....................................................... 4 minimum clearance to combustibles............................. 4 GENERAL INSTRUCTION NOTES......................................... 4 installation of flex gasket........................................ 5 masonry / sheet rock enclosure................................ 6 B Vent / Reline..................................................... 9 Warranty..........................................................2 PolyPro Flex 3

APPLICATION / LISTING For specific information on application, equivalent length of fittings, listings, etc., please reference M&G Duravent's installation instructions for rigid pipe (Document L273). M&G Duravent's PolyPro vent pipe should not be installed in areas where the temperature could exceed 230 F / 0 C. PERMITS Check with your local Building Official, Fire Official, or other authority having jurisdiction regarding permits, restrictions, and installation inspections in your area. Minimum clearance to combustibles Refer to Table A for minimum clearances to combustible materials. Use the values shown in this table unless the appliance manufacturer specifies otherwise. If there is a conflict between the two, the greater clearance shall apply. It is prohibited to place any type of insulation around the venting system within these clearances. 4 Caution Installation applications and terminations shown in these instructions must be approved by the manufacturer of the appliance to which it is applied. Use only listed M&G DuraVent terminations with PolyPro Venting. Vent Orientation Horizontal important Table A Minimum Clearance To Combustibles Table The vent system must terminate in accordance with local code requirements and appropriate National Codes: In the US: NFPA 54 / ANSI Z223. National Fuel Gas Code or the International Fuel Gas Code. In Canada: CAN/CGA-B49. Natural Gas Installation Code or CAN/CGA-49.2 Propane Installation Code. GENERAL INSTALLATION NOTES Reference the Installation Instructions provided with M&G Duravent's rigid pipe (L273) for general instructions. PP Flex must be enclosed, and used in conjunction with rigid PP pipe to connect to an appliance. When used to conduct flue gases, PP flex must not be installed at an angle greater than 45 degrees from vertical. This will ensure proper condensate flow back towards the appliance outlet. PP Flex may be used to bring combustion air into the appliance. In these instances, pipe can be unenclosed and oriented in a vertical or horizontal position. PP flex must be treated carefully to prevent damage when being installed during low temperatures (<4 F, < 5 C). In colder weather, pre-warm flex prior to installation. When relining, it may be easier to insert flex from the bottom up Clearance Single Wall: 0" for flue temperatures up to 94*F (90*C). /4" (6mm) for flue temperatures up to 230*F (0*C). Flex: N/A- NOT ALLOWED Vertical Single Wall: 0" Flex: 0" (Must be enclosed)

rather the top down. Always use soapy water to lubricate gaskets prior to joint assembly. Do not use Petroleum based lubricants! Plastic venting systems shall not pass through rated fire separations. additional instructions for termination M&G Duravent's PP Flex terminations are specifically designed for use with highefficiency appliances that are known to produce high volumes of fluid due to condensation of moisture within flue gases. DO NOT modify these terminations. IMPORTANT: Unless the appliance is designed to address flow of condensates from the vent system, a drain must be incorporated within the vent to allow condensates and rainwater to escape. This drain must include a trap to prevent combustion gases from entering living spaces. Be sure to check the appliance manufacturer's installation instructions closely in regards to condensate management. installation of flex gasket: PP Flex pipe must always have gaskets installed on both ends of any installation. Gaskets are installed on the flex pipe, with the gasket seating inside the flex pipe grooves (Fig.). Use soapy water to assist installation.. Cut PP flex pipe (knife, saw, etc) to desired length. Special care should be taken to ensure cut is square, and the edge is deburred. 2. Place Flex Gasket over Flex pipe and install in the first whole groove nearest the end. 3. Open the locking tabs (x2) of the appropriate flex fitting to accept the flex pipe (Fig.2) 4. Apply soapy water to the gasket, and push pipe/gasket into appropriate flex fitting, seating pipe down until it bottoms out (Fig.2). Figure, Mounting the Gasket gasket IN FIRST GROOVE PP flex pipe PP Flex Gasket (click!) FLEX ADAPTER flex to correct length, clean edge install gasket, use soapy water insert into adapter lock pipe to adapter Figure 2, Installing Gasket / Flex Adapter 5

5. Close locking tabs on flex adapter so tabs seat in the flex pipe. Slight adjustment of pipe may be needed to ensure proper engagement. that is lined with a clay or concrete liner, check to see if a short portion of the tile is sticking out of the top of the chimney. If so, this short top portion must be broken off to permit the termination's flashing to sit down flush on the chimney's crown. It is best to do this prior to beginning the installation.. Determine the required location of the opening within the enclosure. Ensure the flue access cut-out meets the minimum specified size to allow manual assembly of connections within the flue. With masonry chimneys, the breech opening may have to be enlarged Flex Chimney LIning Kit rope Figure 3, Flex Puller FLEX PULLER A flex puller is an optional component available to help ease installation of PP Flex through enclosures (Fig.3). The 2"(60mm) version is of different design than 3"-5"(80mm-30mm). 2" Dia: Unscrew ceramic holder from cone. Install ceramic holder around PP Flex pipe, and re-install into cone. 3"-5" Dia: Connected using bayonet style connection with a rotating movement of /4 turn to lock in.. Wall Plate 2. Support Elbow 3. Flex Chimney Support 4. Flex Male Adapter 5. Clamp (or Tie) 6. Flex Coupler 7. Gasket 8. Flex Liner 9. Spacer 0. Support Bracket. Flex Female Adapter 2. Flex Chimney Cap Flashing 3. Termination Pipe 6 3 2 0 7 9 8 7 Masonry / SHEET ROCK enclosure: Examine the chimney or enclosure carefully for obstructions prior to starting an installation. Any structural defects or potential safety problems must be repaired prior to relining, and the enclsoure should be clean. If working with a masonry chimney 2 3 5 4 6

to permit proper access. If this is the case, patch up the opening after the installation is completed using best practices. The slope of the rigid connecting flue pipe must have a minimum of 3 (equivalent 5cm/m) (5/8" per foot). 2. Fix the Flex Chimney Support (Fig.4) with 4 screws on the wall of the enclosure. 6. Install PP Flex liner into the enclosure. A second person is required to help feed the flexible liner into position (feeding either from the top or bottom of the enclosure). This will also help prevent damage from occurring. 7. After installing the required length of liner, remove the Flex Puller (if applicable) 8a. Position the Support Elbow on the Flex Chimney Support (see 2 and 3, Fig.5) 8b. Secure the Support Elbow with the clamp around the Flex Male Adapter and through the slot of the Flex Chimney Support (see, Fig.6). 2 3 Figure 4, Mounting Flex Chimney Support 3. The length of the flexible liner can be determined in two ways: use a rope with a weight to measure the shaft length, add 6" (40cm) extra length for each bend. The flexible liner can be shortened with a saw or scissors by cutting in a groove. The correct length can also be determined after installing the liner in the shaft and cutting it at the top of the chimney, see Fig.8, dimension B. 4. Mount the Gasket into the flex pipe, and attach to the appropriate coupler as detailed above. 5. Mount the Spacers with a maximum distance between them of 6 feet (2m). Figure 5, Installation Support Elbow Figure 6, Securing Support Elbow 9. Mount the Wall Plate on the wall of the shaft (Fig.7). Pay attention to the correct slope of 3. The pipe of the Support Elbow must be in the centre of the hole in the Wall Plate. 0. The Support Elbow can be shortened if required- For single wall, Dim A (Fig.7) must have a minimum length of.6" (40mm).. At the top of the shaft, shorten the flexible liner to the required length and make sure that dimension B in Fig.8 is between ½ - 2½" (between 38 and 64 mm). 7

= = 5. Install the Termination Pipe(see, Fig.0). Assemble the storm collar portion of the Flex Chimney Flashing (see 2, Fig.0). 6. Connect the appliance to the flexible vent system with M&G DuraVent rigid PolyPro vent system. = = 3 A 2 Figure 7, Mounting the Wall Plate 3. Fit the Support Bracket (see, Fig.8) over the liner and let it rest on the wall of the shaft. Mount the Gasket as detailed above (see Fig.). Push the Flex Female Adapter on the liner and close the latching tabs. Allow the assembly to rest on the Support Bracket. 4. Seal the edge of the chimney shaft with water-resistant sealant (see, Fig.9) and push the Flex Chimney Flashing (see 2, Fig.9) on the shaft and fix it with four masonry anchors (see 3, Fig.9). Figure 9, Installing Vent Cap 2 B Figure 8, Required Liner Length Figure 0, Installing Termination Pieces 8

B VENT RELINE: From within the room where the appliance is located, remove any existing horizontal or angled sections of B Vent. PP Flex cannot be installed at an angle greater than 45 degrees from vertical. The B Vent Adapter-Lower will fit over the bottom of the existing B Vent's vertical stack at or near the ceiling. Carefully inspect the B Vent to ensure integrity. Ensure any visible screws or obstructions are removed. PP Rigid pipe must be used to complete install to the appliance- Instructions- 2" (60mm) PP Flex in B Vent. Remove existing B Vent termination cap 2. Carefully feed flex down through B Vent so approx 2' of flex extends beyond the bottom of the B Vent (Flex puller or rope aid optional) 3. Cut to length the top of Flex pipe and insert flex through B Vent Adapter- Upper, and through the Termination Base. 4. Install the PP Flex Gasket and Flex Female Adapter onto Flex pipe using instructions in previous pages. 5. Lower the B Vent Adapter- Upper onto the top of the existing B Vent and secure using screws (x3) supplied with the hardware kit. 6. Attach the Termination Top to the Termination Cap (clicks when engaged), then insert the Flex Female Adapter into the Termination Cap. Push the assembly onto the Termination Base (clicks when engaged, see Fig.2). 7. Push the completed assembly down onto the B-Vent Adapter- Upper. When level, secure with three screws provided. 8. At the bottom end, cut the PP Flex to length 3" below the bottom of the vertical B Vent still portruding from the ceiling. 9. Install the Flex Gasket and Flex Male Adapter onto the Flex pipe 0. Install B Vent Adapter- Lower. (Flex Male Adapter should protrude beyond per Fig.3) (click!). Secure the B Vent Adapter- Lower to the B Vent using three screws from the supplied hardware. Figure 2 TERMINATION TOP TERMINATION CAP FLEX FEMALE ADAPTER 2" (60MM) FLEX GASKET 2" (60mm) FLEX TERMINATION BASE MOUNTING HARDWARE B VENT ADAPTER- UPPER B VENT PIPE 2" (60MM) FLEX GASKET FLEX MALE ADAPTER MOUNTING HARDWARE B VENT ADAPTER- LOWER Figure - (2" Flex / B Vent) 9

b vent adapterlower b vent pipe mounting hardware flex female adapter b vent adapterupper c support bracket flex male adapter b vent pipe Figure 3 Figure 4 Instructions- 3" (80mm) PP Flex in B Vent. Remove existing B Vent termination cap 2. Carefully feed flex down through B Vent so approx 2' of flex extends beyond the bottom of the B Vent (Flex puller or rope aid optional) 3. Cut to length the top of Flex pipe and insert flex through B Vent Adapter- Upper 4. Install PP Flex Gasket and Flex Female Adapter onto Flex pipe per instructions detailed above 5. Lower B Vent Adapter- Upper to the top of the B Vent and secure with screws (x3) supplied 6. Install C Support Bracket as shown in Fig.4 and lower Flex Female Adapter into B Vent Adapter- Upper 7. Attach Termination Top to Termination Cap (clicks when engaged), insert 3" Rigid Pipe into Termination Cap, and attach Termination Insert into Termination Cap (clicks). Then connect Termination Insert to Termination Transition (click). 8. Line up inner pipe connections and push termination assembly down onto B Vent Adapter- Upper and secure with screws (x3) provided 9. Cut Flex to length 3" below the bottom of the B Vent 0. Install Flex Gasket and Flex Male Adapter on Flex. Install B Vent Adapter- Lower. (Flex Male Adapter should protrude beyond per Fig.3) 2. Secure B Vent Adapter- Lower to B Vent with hardware provided TERMINATION top TERMINATION CAP 3" (80MM) RIGID PIPE TERMINATION INSERT TERMINATION TRANSITION C SUPPORT BRACKET B VENT ADAPTER- UPPER FLEX FEMALE ADAPTER 3" (80MM) FLEX GASKET 3" (80mm) FLEX B VENT PIPE 3" (80MM) FLEX GASKET FLEX MALE ADAPTER MOUNTING HARDWARE B VENT ADAPTER- LOWER Figure 5- (3" Flex / B Vent) 0

Polypro WARRANTY M&G DuraVent, Inc. ( DuraVent ) provides this warranty for PolyPro for ten years. Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained and used. DuraVent products are fully warranted if installed only by a professional installer. This Warranty is transferable from the original homeowner to the buyer of the home within the warranted ten years. This warranty does not cover normal wear and tear, smoke damage or damage caused by chimney fires, acts of God, or any product that was: () purchased other than from an authorized DuraVent dealer, retailer or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use not in accordance with the installation instructions included with the product as determined by DuraVent. Installation instructions are available online at www.duravent.com under Support/Literature and through our Customer Service Department 800-835-4429 or customerservice@duravent.com. DuraVent provides the following warranties for PolyPro: One Hundred Percent (00%) MSRP 0 years from the date of purchase. All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each product line. These remedies shall constitute DuraVent s sole obligation and sole remedy under this warranty. This warranty provides no cash surrender value. The terms and conditions of this warranty may not be modified, altered or waived by any action, inaction or representation, whether oral or in writing, except upon the express, written authority of an executive officer of DuraVent. This product is intended for venting only category IV appliances burning Natural Gas, Propane and Oil. All other fuels are not covered under this warranty. LIMITATIONS ON POLYPRO INTERNET SALES: Notwithstanding any other terms or conditions of this PolyPro Warranty, DuraVent provides no warranty for PolyPro if it is not installed by a qualified professional installer. DuraVent must be notified and given the opportunity to inspect defective product prior to replacement under the terms of this limited lifetime warranty. All warranty claims must be submitted with proof of purchase. Labor and installation costs are not covered under this warranty. To obtain warranty service contact: DuraVent Warranty Service, 877 Cotting Ct., Vacaville CA 95688, or call 800-835-4429. WHERE LAWFUL, DURAVENT DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL DURAVENT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR SPECIAL DAMAGES OR DIRECT OR INDIRECT LOSS OF ANY KIND, INCLUDING BUT NOT LIMITED TO PROPERTY DAMAGE AND PERSONAL INJURY. DURAVENT S ENTIRE LIABILITY IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT. SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. For the most up-to-date installation instructions, see www. duravent.com REV 3.22.202 Customer Service Support 800-835-4429 707-446-4740 FAX www.duravent.com PolyPro and GreenVent are registered trademarks of M&G DuraVent, Inc. All rights reserved, 202 M&G DuraVent is a member of M&G Group. 9/202 L272