Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Similar documents
Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Scope of Accreditation For Retlif Testing Laboratories

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

China Nuclear Power EQ Testing

STS Directory Accreditation number: STS 0050

SPEAKER SC-COBRA

Transport of IGCT. The transportation of IGCT is classified according to IEC set IE22. Power and productivity for a better world

High Current Thermal Fuse

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Feb12 Rev D

Anecto Ltd. Ballybrit Business Park, Galway. Testing Laboratory Registration number: 175T

EUROPEAN ETS TELECOMMUNICATION May 1994 STANDARD

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

QA Test Report VITA-350. (Product Reliability Test) Charles Chang Manager of QA Department. Knight Hu Test Engineer. Jeff Yang Approval

AC/DC Converter SLH40 Series

U7242A USB3.0 Test Fixture

A Study of Environmental Test Sequences for Electrical Units Jung Ho Yang, Yong Soo Kim

DC-DC Converters MI-J00

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CONTECH RESEARCH INC. 750 Narragansett Park Drive Rumford, RI Thomas Lamoureux

Military Attenuator Module

PROFESSIONAL LED GROW LIGHTS PRODUCT BROCHURE

SMPM Female Cabled Connectors

NCE Energy saving circulating pumps

Product Specification JUL 14 Rev. A1

LSA 47.2 Low Voltage Alternators - 4 pole

Equipment Requirements SBC Local Exchange Carriers May 2001 NETWORK EQUIPMENT POWER, GROUNDING, ENVIRONMENTAL, AND PHYSICAL DESIGN REQUIREMENTS

Mar11 Rev B

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

LSA 42.3 Low Voltage Alternators - 4 pole

MAR 17 Rev B1

3820 en / c

HotSwap MBP Maintenance Bypass

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

European Machinery Directive 2006/42/EC & Related Directives

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

EUROPEAN ETS TELECOMMUNICATION February 1992 STANDARD

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

LSA Rating Table Low Voltage Alternators - 4 pole

Mark R. Chrusciel. Director of Sales. For a copy of the slides

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

General Requirements. Technical Specifications for Insulators of Transmission Lines

Power Resistor for Mounting onto a Heatsink Thick Film Technology

General Purpose Chip Resistors MCMR Series

Protection classification IP 23

UNS 5kA Arrester. Certified Test Report IEC

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

B. Provide liquid-filled secondary substation transformers as indicated on drawings.

New Designs. Not Recommended for. KDZ6.8B Zener Diode Data sheet Outline P D 1000 mw PMDU SOD-123 SC-109B

High Ohmic / High Voltage Metal Glaze Leaded Resistors

Seismic Qualification Test Protocols, Standards and Methodology

EUROPEAN ETS TELECOMMUNICATION February 1992 STANDARD

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Model BF 720 Incubators Avantgarde.Line with forced convection

Mar11 Rev B

Super Fast Recovery Diode RF601BM2D

Technical System Catalogue Modular PDU (PSM)

Schottky Barrier Diode RBR5L30B

SST2222A V CEO I C. 40V 600mA. Datasheet. NPN Medium Power Transistor (Switching) lfeatures 1)BV CEO >40V(I C =10mA) 2)Complements the SST2907A

Extended-Frequency SMA Connectors

Pump down time for 5 l receiver

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

SM-220-MP SHOCK TEST MACHINE. Halfsine. Sawtooth. Squarewave

SOMFY SPECIFICATION March 2012 SECTION... ROLLER WINDOW SHADES SOMFY LS 40 MOTOR RANGE. Disclaimer for advice given to architects and engineers

2.6± ±0.1. Taping specifications (Unit : mm) 4.0± ±0.05 φ1.55± ± ±0.1 φ1.0± Duty 0.5

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

2SD1980 V CEO 100V I C 2A R 1 R kΩ 300Ω. Datasheet. Power Transistor (100V, 2A)

Liquid level switch BW 17

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Mar11 Rev D

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

EMD59. Datasheet. Complex Digital Transistors (Bias Resistor Built-in Transistors)

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES

Emissions level: EPA NSPS Stationary Emergency Tier 2

Applications R46 K I P0 M

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Water Level Meter User Manual

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Schottky Barrier Diode RBQ10BM65A

Agilent 8490G Coaxial Attenuators

High Pulse, Fusible, Non-Inductive, Flameproof, Metal Film Resistor

RF Transformer (Stabilized Matching Device) SMST18 series

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

New Designs. Not Recommended for 2SCR293P V CEO 30V I C. Datasheet. Middle Power Transistors (30V / 1A) lfeatures. linner circuit

ARC STUD WELDING SYSTEMS

SERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES A

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

230V 50HZ/60HZ 3PHASE 4 WIRE POWER PANEL AND 1PHASE 4 WIRE DISTRIBUTION BOX FOR DOMESTIC/PORTABLE EQUIPMENT POWER SUPPLY

Model FDL 115 Safety drying chambers for limited quantities of solvent

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Applications R49 A N B1 M

RESD1CANFH Transient Voltage Suppressor (AEC-Q101 qualified) Data sheet

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PCIEC/PCIE PCIEC EC-EC-AP/PCIE F-D-RA

Mar11 Rev C

RB060LAM-40 Schottky Barrier Diode

Transcription:

Product Development and Qualification Airport Works Rochester Kent ME1 2XX Contact: Mr P J Davison Tel: +44 (0)1634 204457 Fax: +44 (0)1634 203647 E-Mail: paul.j.davison@baesystems.com Website: www.baesystems.com/faradaytestcentre Testing performed at the above address only DETAIL OF ACCREDITATION Aerospace Equipment 1 EMC TESTING Aerospace Materials Aerospace Structures 1.1 MILITARY EMC TESTS Cells and Batteries Circuit Breakers and Switches 1.1 Conducted Emissions BS3G100:Part 4:Section 2, 1980 Computers and Peripherals 20 Hz to 1 GHz Electrical Cables including exported spikes and DEF STAN 59-41:1995 Electrical/Electronic Components Transients (Time Domain) Part 3:Issue 5 Electrical/Electronic Connectors DCE01, DCE02, DCE03 Electrical/Electronic Products Electro-mechanical Devices DEF STAN 59-41:2003 Enclosures for Electrical Equipment Part 3, Section 3, Issue 1, Engine Components DCE01.3, DCE02.3, DCE03.1 Fans Fire Prevention and Detection DEF STAN 59-411:2007 Equipment Part 3, Issue 1 Gas Detectors: Electronic & Amendment 1:31 January 2008 Generators: Electrical DCE02.A Generators: Power DCE01.B, DCE02.B, DCE03.B Instruments for Measuring Vehicle Instruments - Indicating, Recording Panavia SP-P-90003, Issue 3 Luminaires CE01, CE02, CE03, CE04, CE1 Magnetic Materials Marine Equipment Panavia: SP-P-90-010, Issue 1 Measuring Equipment CE-TOR-1, CE-TOR-2, CE-TOR-3 Medical/Dental Equipment Microelectronic Circuits and EFA: SPE-J-000-E-1000, Issue 1, Components CE-EFA-1, CE-EFA-2, CE-EFA-3 Mining Equipment Components Missile Components EFA: SPE-J-000-E-1006, Issue 2 Missiles: Guided CE-EFA-1, CE-EFA-2, CE-EFA-3 Missiles: Unguided Motors and Generators, Electrical Boeing D6-16050, Rev A to D, 1986 Office Equipment, Electrical Assessment Manager: CA Page 1 of 26

Continued from Page 1 1 EMC TESTING Plugs and Sockets 1.1 MILITARY EMC TESTS Security Devices and Alarms Sonar Equipment 1.1.1 Conducted Emissions RTCA DO-160 A: Section 21 Switchboards: Electrical 20 Hz to 1 GHz : Section 21 Telecommunications Equipment including exported spikes and : Section 21 Toys Transients (Time Domain) : Section 21 (cont'd) : Section 21 : Section 21 : Section 21 EUROCAE ED-14E: Section 21 EUROCAE ED-14F: Section 21 EUROCAE ED-14G: Section 21 MIL-STD-461A, Notices 1 to 6 CE01, CE02, CE03, CE04 MIL-STD-461B MIL-STD-461C, Notices 1 and 2 CE01, CE03, CE07 MIL-STD-461D MIL-STD-461E MIL-STD-461F CE101, CE102 1.1.2 Radiated Emissions BS3G100:Part 4:Section 2, 1980 20 Hz to 40 GHz DEF STAN 59-41:1995 Part 3:Issue 5, DRE01, DRE02 DEF STAN 59-41: 2003 Part 3, Section 3, Issue 1 DRE01.3, DRE02.3 DEF STAN 59-411:2007 Part 3, Issue: 1, & Amendment 1: 31 January 2008 DRE01.A DRE02.A DRE01.B, DRE02.B Assessment Manager: CA Page 2 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.1 MILITARY EMC TESTS 1.1.2 Radiated Emissions Panavia SP-P-90003, Issue 3 20 Hz to 40 GHz (cont'd) RE01, RE02 Panavia: SP-P-90-010, Issue 1 RE-TOR-1 EFA: SPE-J-000-E-1000, Issue 1, RE-EFA-1, RE-EFA-2 EFA: SPE-J-000-E-1006, Issue 2 RE-EFA-AGE-1, Boeing D6-16050-4, Rev A to D, 1986 RTCA DO-160 A: Section 21 : Section 21 : Section 21 : Section 21 : Section 21 : Section 21 : Section 21 EUROCAE ED-14E: Section 21 EUROCAE ED-14F: Section 21 EUROCAE ED-14G: Section 21 MIL-STD-461A, Notices 1 to 6 MIL-STD-461B MIL-STD-461C, Notices 1 and 2 RE01, RE02 MIL-STD-461D MIL-STD-461E MIL-STD-461F RE101, RE102 1.1.3 Compass Safe Distance BS 3G100, Part 2, Section 2: 1972 : Section 15 : Section 15 : Section 15 : Section 15 Assessment Manager: CA Page 3 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.1 MILITARY EMC TESTS 1.1.3 Compass Safe Distance EUROCAE ED-14E: Section 15 EUROCAE ED-14F: Section 15 EUROCAE ED-14G: Section 15 SP-P-90-010 Issue 1 RE-TOR-CSD 1.1.4 Conducted Susceptibility BS3G100:Part 4:Section 2, 1980 DC to 400 MHz DEF STAN 59-41: 1995 Part 3, Issue 5 DCS01, DCS02, DCS03 DEF STAN 59-41: 2003 Part 3, Section 3, Issue 1 DCS01.3, DCS02.3, DCS03.3 DEF STAN 59-411:2007 Part 3, Issue: 1, & Amendment 1: 31 January 2008 DCS02.A DCS01.B, DCS02.B, DCS03.B Panavia SP-P-90003, Issue 3, CS01, CS02 Panavia: SP-P-90-010, Issue 1 CS-TOR-1, CS-TOR-2 EFA: SPE-J-000-E-1000, Issue 1, CS-EFA-1, CS-EFA-2 EFA: SPE-J-000-E-1006, Issue 2 CS-EFA-1, CS-EFA-AGE-2 Boeing D6-16050-4, Rev A to D, 1986 RTCA DO-160 A Assessment Manager: CA Page 4 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.1 MILITARY EMC TESTS 1.1.4 Conducted Susceptibility DC to 400 MHz Sections 18 19 & 20 EUROCAE ED-14E EUROCAE ED-14F EUROCAE ED-14G Sections 18 19 & 20 MIL-STD-461A & Notices 1 to 6 CS01, CS02 MIL-STD-461B & Notices 1 and 2 MIL-STD-461C CS01, CS02, CS09 MIL-STD-461D MIL-STD-461E MIL-STD-461F CS101, CS109, CS114 MIL-STD-461A & Notices 1 to 6 1.1.5 Conducted Susceptibility DEF STAN 59-41: 1995 imported spikes, surges Part 3, Issue 5 and transients DCS04, DCS05, DCS06 (Damped Sinusoids limited to 40A DEF STAN 59-41: 2003 And 4kV, 7kHz to 100MHz) Part 3, Section 3, Issue 1 DCS04.3, DCS05.3, DCS06.3 (No Phase Control on Type 2 Transient for DEF STAN) DEF STAN 59-411: 2007 Part 3, Issue 1 & Amendment 1: 31 January 2008 DCS04.B, DCS05.B, DCS06.B Panavia SP-P-90003, Issue 3, CS1 Panavia: SP-P-90-010, Issue 1 CS-TOR-4 EFA: SPE-J-000-E-1000, Issue 1, EFA: SPE-J-000-E-1006, Issue 2 CS-EFA-4 Assessment Manager: CA Page 5 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.1 MILITARY EMC TESTS 1.1.5 Conducted Susceptibility RTCA DO-160 A: Section 17 imported spikes, surges : Section 17 and transients : Section 17 : Section 17 : Section 17 : Section 17 : Section 17 EUROCAE ED-14E: Section 17 EUROCAE ED-14F: Section 17 EUROCAE ED-14G: Section 17 MIL-STD-461A & Notices 1 to 6 MIL-STD-461B MIL-STD-461C & Notices 1 and 2 CS06 MIL-STD-461D MIL-STD-461E MIL-STD-461F CS115 1.1.6 Power Supply BS 3G100, Part 3: 1979 DC, 15Hz to 2.5kHz Panavia SP-P-90001, Issue 5 & 6 AC specification 18kVA or 6kVA/phase maximum EFJ-SP-EFA-240-2036, Issue 3, 144A/single, 48A/3 phase r.m.s March 1988, Appendix A DC specification RTCA DO-160 A: Section 16 9kW or 3kW 3 phase DC : Section 16 424V/36A or 212V/72A : Section 16 : Section 16 : Section 16 : Section 16 : Section 16 EUROCAE ED-14E: Section 16 EUROCAE ED-14F: Section 16 EUROCAE ED-14G: Section 16 Assessment Manager: CA Page 6 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.1 MILITARY EMC TESTS 1.1.6 Power Supply DC, 15Hz to 2.5kHz Electrical Characteristics of A350 AC and DC equipment MIL-STD-704A MIL-STD-704B MIL-STD-704C MIL-STD-704D MIL-STD-704E MIL-STD-704F ABD0100.1.8.1 issue C Excludes test 104 for all supply types 1.1.7 Radiated Susceptibility DEF STAN 59-41: 1995 DC to 40 GHz Part 3, Issue 5 DRS01, DRS02, DMFS01 Field strength dependent on EUT Size and frequency range DEF STAN 59-41: 2003 Part 3, Section 3, Issue 1 10kHz to 200MHz up to 400 V/m DRS01.3, DRS02.3, DRS03.3 200MHz to 1GHz up to 700 V/m DEF STAN 59-411: 2007 Part 3, Issue 1 1GHz to 18GHz up to 4000 V/m & Amendment 1: 31 January 2008 DRS01.A, DRS02.A 18GHz to 26.5GHz up to 400 V/m DRS01.B, DRS02.B, DRS03.B 26.5GHz to 40GHz up to 600 V/m Panavia SP-P-90003, Issue 3, RS1, RS03 (Magnetic and Electric field) Panavia: SP-P-90-010, Issue 1 RS-TOR-1, RS-TOR-3 EFA: SPE-J-000-E-1000, Issue 1, RS-EFA-1, RS-EFA-2, RS-EFA-3 EFA: SPE-J-000-E-1006, Issue 2 RS-EFA-AGE-3 Boeing D6-16050-4 Revision A to D Assessment Manager: CA Page 7 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.1 MILITARY EMC TESTS 1.1.7 Radiated Susceptibility RTCA DO-160 A: Section 20 DC to 40 GHz : Section 20 : Section 20 : Section 20 : Section 20 : Section 20 : Section 20 EUROCAE ED-14E: Section 20 EUROCAE ED-14F: Section 20 EUROCAE ED-14G: Section 20 MIL-STD-461A & Notices 1 to 6 MIL-STD-461B MIL-STD-461C & Notices 1 and 2 RS01, RS02, RS03 MIL-STD-461D MIL-STD-461E MIL-STD-461F RS101. RS103 1.1.8 ESD DEF STAN 59-41: 1995 Part 3, Issue 5 (Limited to 32kV maximum) DCS10 DEF STAN 59-41: 2003 Part 3, Section 3, Issue 1 DCS10 DEF STAN 59-411: 2007 Part 3, Issue 1 & Amendment 1: 31 January 2008 DCS10 EFA: SPE-J-000-E-1000, Issue 1, EFA: SPE-J-000-E-1006, Issue 2 ESD-EFA-1 : Section 25 : Section 25 : Section 25 : Section 25 Assessment Manager: CA Page 8 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.1 MILITARY EMC TESTS 1.1.8 ESD EUROCAE ED-14E: Section 25 EUROCAE ED-14F: Section 25 EUROCAE ED-14G: Section 25 1.1.9 EMP DEF STAN 59-41: 1995 7 khz to 100 MHz Part 3, Issue 5 DCS08 (Damped Sinusoids limited to 40A And 4kV, 7kHz to 100MHz) DEF STAN 59-41: 2003 Part 3, Section 3, Issue 1 DCS08.3 DEF STAN 59-411: 2007 Part 3, Issue 1 & Amendment 1: 31 January 2008 DCS08.B EFA: SPE-J-000-E-1000, Issue 1, NEMP-EFA-1 MIL-STD-461C & Notices 1 and 2 CS11 MIL-STD-461D MIL-STD-461E MIL-STD-461F CS116 Assessment Manager: CA Page 9 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.2 CIVIL EMC TESTS 1.2.1 Conducted Emissions EN 55011:2009+A1:2010 150 khz to 30 MHz 1.2.2 Harmonic Current emissions EN 61000-3-2:2006 Measurements up to 40 th EN 61000-3-2:2014 Harmonic, 13A max 1.2.3 Voltage Fluctuations and EN 61000-3-3:2008 Flicker EN 61000-3-3:2013 230V, 13A Pst, Plt, dt, dmax, dc 1.2.4 Electrostatic discharge EN 61000-4-2:2009 Up to 30 kv air Up to 30 kv contact 1.2.5 Electrical Fast transietns EN 61000-4-4:2012 Up to 4.8 kv 1.2.6 Surges EN 61000-4-5:2006 1.2/50 μs up to4.4 kv 1.2.7 Conducted disturbance EN 61000-4-6:2009 Immunity EN 61000-4-6:2014 150 khz to 80 MHz Up to 10 Vrms 1.2.8 Power Frequency immunity EN 61000-4-8:2010 Up to 100 A/m 1.2.9 Voltage Dips and Interruptions EN 61000-4-11:2004 AC 230V up to 16A, 230 A inrush current Assessment Manager: CA Page 10 of 26

As listed on Pages 1 and 2 1 EMC TESTING 1.2 CIVIL EMC TESTS 1.2.10 Radiated Susceptibilty EN 61000-4-3:2006+A1:2008+ 80 MHz to 2.7 GHz A2:2010 Up to 10V/m FACILITIES FOR EMC TESTING Nine electromagnetically screened rooms. ETF 10: Fully lined (ferrite & Absorber) Screened Enclosure Length 8.58m, Width 7.36m and Height 4.2m. Door size: ETF 11: Screened Enclosure: 3.75m x 3.09m x 3.0m. ETF 12: Screened Enclosure: 4.97m x 3.09m x 3.0m ETF 13: Screened Enclosure: 3.73m x 3.09m x 3.0m ETF 20: Fully lined (ferrite & Absorber) Screened Enclosure Length 8.58m, Width 7.36m and Height 4.2m. Door size: ETF 21: Screened Enclosure: 3.75m x 3.09m x 3.0m. ETF 22: Screened Enclosure: 4.97m x 3.09m x 3.0m ETF 30: Semi-lined (ferrite & Absorber) Screened Enclosure Length 7.34m, Width 5.54m and Height 4.5m. ETF 31: Screened Enclosure: 3.75m x 3.10m x 3.0m Two external ground planes Power supplies include: 20 kva, 3 phase, 400 Hz (200V phase to phase) 30 kva, 3 phase, 50 Hz (415V phase to phase) 3 kva, single phase, variable frequency 1 kva, 3 phase, variable frequency 240V, 13A, single phase 50 Hz 28V, 100A DC Other DC voltages available Compressed air supply up to 100psi Water supply at mains pressure Exhaust venting in one screened room only All rooms air conditioned Note: Tests may be carried out to other specifications which are derived from, or are amalgamations of, those specifications on the Schedule. Assessment Manager: CA Page 11 of 26

Aerospace Equipment Aerospace Structures Cells and Batteries 2.1 Drop and Topple/Free Fall BS 2011:Ec:1977 Coatings: Metallic Max mass: 100 kg (IEC 68-2-31:1993) Computers and Peripherals Max size: 90 cm x 90 cm Domestic Appliances: Electrical TR 2130:Issue B:1993 Domestic Appliances: Non-Electrical DEF-STAN 07-55:1975 Electrical/Electronic Components Test A9 Electrical/Electronic Connectors Electrical/Electronic Products DEF-STAN 00-35: Issue 3 and 4 Electrical Cables Test M4 Electro-mechanical Devices Engine Components Fasteners 2.2 Bump BS 2011:Eb:1987 Fire Fighting and Detection Max mass: 750 kg (IEC 68-2-29:1993) Equipment Max size: 1.5 x 1.5 x 1.5 m Generators: Electrical TR 2130:Issue B:1993 Instruments for Measuring Vehicle Instruments - Indicating, Recording DEF-STAN 07-55:1975 Marine Equipment Test A5 Metallic Coatings/Treatment Measuring Equipment DEF-STAN 00-35: Issue 3 and 4 Mechanical Products Test M12 Medical/Dental Equipment Metallic Coatings/Treatment Microelectronic Circuits and 2.3 (a) Shock on Vibrator BS 2011:Ea:1988 Components Max mass: 750 kg (IEC 68-2-27:1993) Mining Plant and Equipment Max size: 1.5 x 1.5 x 1.5 m Missile Components Peak thrust: 57 kn RIA 20, Issue 2:1994 Missiles: Guided Max level: 100g Missiles: Unguided Max displacement: 35 mm TR 2130:Issue B:1993 Motor Vehicle Accessories and Slip table size: 0.9 x 0.9 m Components DEF-STAN 07-55:1975 Motors, Electrical Test A3 Office Equipment, Electrical Office Equipment, Mechanical RTCA DO-160 A Packages and Packaging Material Pipes and Pipeline Products Plugs and Sockets: Electrical Power Supplies: Electrical Printed Circuit Boards Radar Equipment Radio and TV Equipment Section 7 Satellites and Sub-assemblies And EURCAE ED-14 equivalent Security Devices and Alarms Sonar Equipment Assessment Manager: CA Page 12 of 26

Continued from Page 10 Structural Components and Fixings Switchboards: Electrical 2.3 (a) Shock on Vibrator DEF-STAN 00-35: Issue 3 and 4 Telecommunication Equipment Tests M3 and M6 Transformers: Electrical Valves: Engineering Weapons and Sub-assemblies MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 516 2.3 (b) Shock on Shock machine BS 2011:Ea:1988 Half Sine Only (IEC 68-2-27:1993) Max mass: 454 kg Specimen mounting area: RIA 20:Issue 2:1994 0.95 x 0.95 m Max acceleration: 600g TR 2130:Issue B:1993 Max pulse duration: 80 ms Max velocity change: DEF-STAN 07-55:1975 7.62 m/sec Test A3 RTCA DO-160 A Section 7 And EURCAE ED-14 equivalent MIL-STD-810 B Method 516 DEF-STAN 00-35:Issue 3 and 4 Test M3 Assessment Manager: CA Page 13 of 26

As listed on Pages 10 and 11 2.4 Vibration: Sinusoidal at BS 2011:Fc:1983 ambient temperature only (IEC 68-2-6:1996) Frequency range: 2 Hz to 5 khz BS3G100:Part 2:Section 3: Peak thrust: 57 kn Sub-section 3.1:1969(1983) Max mass: 750 kg Max size: 1.5 x 1.5 x 1.5 m TR 2130:Issue B:1993 Slip table size: 0.9 x 0.9 m DEF-STAN 07-55:1975 Test A1 NES 1004:Issue 1:1987 Data Sheet 25 RTCA DO-160 A Section 8 And EURCAE ED-14 equivalent MIL-STD-781C:1977 MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 514 DEF-STAN 00-35: Issue 3 and 4 Test M1 Assessment Manager: CA Page 14 of 26

As listed on Pages 10 and 11 2.5 Vibration: Random at ambient IEC 60068-2-64 temperature only Frequency range: BS 2011:Fd:1973 (1984) 2 Hz to 5 khz (IEC 68-2-34:1973) RMS thrust: 40 kn Max mass: 750 kg BS3G100:Part 2:Section 3: Max size: 1.5 x 1.5 x 1.5 m Sub-section 3.1:1969(1983) Slip table size: 0.9 x 0.9 m RIA 20:Issue 2:1994 TR 2130:Issue B:1993 DEF-STAN 07-55:1975 Test A2 DEF-STAN 00-35: Issue 3 and 4 Test M1 RTCA DO-160 A Section 8 EURCAE ED-14 equivalent MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 514 2.6 Acceleration - Steady State BS 2011:Ga:1984 Max accel: 30 g at 1 m (IEC 68-2-7:1983) Max radius: 1.1 m Max mass: 68 kg BS3G100:Part 2:Section 3: Max size: Sub-section 3.6 0.45 x 0.45 x 0.45 m DEF-STAN 07-55:1975 Test A6 Assessment Manager: CA Page 15 of 26

As listed on Pages 10 and 11 2.6 Acceleration - Steady State RTCA DO-160 A Section 7, Procedure 2 EURCAE ED-14 equivalent MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 513 DEF-STAN 00-35:Issue 3 and 4 Test M13 2.7 Gunfire Vibration - at ambient MIL-STD-810 D temperature only Frequency range: 2 Hz to 5 khz MIL-STD-810 G RMS thrust: 40 kn Method 519 Max size: 1.5 x 1.5 x 1.5 m Slip table size: 0.9 x 0.9 m 2.8 High Temperature - at Low BS 2011:Bb:1977 Humidity (IEC 68-2-2:1974) Controlled Humidity: BS 2011:Bd:1977 10% min from +20 C to +75 C (IEC 68-2-2:1974) Tolerance on RH = ±5% TR 2130:Issue B:1993 Uncontrolled Humidity: + 75 C to 100 C DEF-STAN 07-55:1975 Test B1, B2 Max chamber size: 1.5 x 1.75 x 2.2 m NES 1004:Issue 1:1987 Data Sheets 7 and 9 Assessment Manager: CA Page 16 of 26

As listed on Pages 10 and 11 2.8 High Temperature - at Low MIL-STD-810 B Humidity MIL-STD-810 D MIL-STD-810 G Method 501 DEF-STAN 00-35: Issue 3 and 4 Test CL1 2.9 High Temperature - at High BS 2011:Ca: 1977 Humidity (IEC 68-2-3:1969) Max temp: 75 C Max RH: = 95% BS 2011:Cb:1990 Tolerance on RH: = 5% (IEC 68-2-56:1988) Chamber size: 1.5 x 1.75 x 2.2 m BS 2011:Da:1977 (IEC 68-2-4:1960) BS 2011:Db:1981 (IEC 68-2-30:1980) BS3G100:Part 2:Section 3: Sub-section 3.7 TR 2130:Issue B:1993 DEF-STAN 07-55:1975 Tests B6, B7 and B8 NES 1004:Issue 1:1987 Data Sheet 7 RTCA DO-160 A Section 6 And EURCAE ED-14 equivalent Assessment Manager: CA Page 17 of 26

As listed on Pages 10 and 11 2.9 High Temperature - at High MIL-STD-810 B Humidity MIL-STD-810 D MIL-STD-810 G Method 507 DEF-STAN 00-35: Issue 3 and 4 Test CL6 and CL7 2.10 Combined Temperature/ MIL-STD-810 B Altitude/Humidity Max Temp: 120 C Method 518 Min Temp: -60 C Max Altitude: MIL-STD-810 D 30 mb (95000 ft) Max RH: 95% Chamber size: 1 x 1 x 1.5 m MIL-STD-810 G Chamber size: 1 x 1 x 1.5 m Method 520 (without vibration) Chamber size: 1 x 1 x 1 m 2.11 High and Ambient BS 2011:Z/BM:1977 Temperature -at Low Pressure (IEC 68-2-41:1976) Max temp: 120 C Max altitude: 15 mb (95000 ft) BS3G100:Part 2:Section 3: Chamber size: 1 x 1 x 1.5 m Sub-section 3.2:1970(1983) Chamber size: 1 x 1 x 1.5 m Chamber size: 1 x 1 x 1 m DEF-STAN 07-55:1975 Test sample can be supplied Test B11 with cooling air whilst Part 2:Section 2/1:Test B21 maintaining altitude conditions (max: 2 lbs/min at -45 C to NES 1004:Issue 1:1987 +70 C) Data Sheet 14 MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 500 Assessment Manager: CA Page 18 of 26

As listed on Pages 10 and 11 2.11 High and Ambient DEF-STAN 00-35: Issue 3 and 4 Temperature -at Low Pressure Test CL11 and CL21 DEF-STAN 00-35:1999 Test CL11 and CL21 RTCA DO-160 A Paragraph 4.6.1 And EURCAE ED-14 equivalent 2.12 Low Temperature BS 2011:Ab:1980 (IEC 68-2-1:1990) Min temp: Chamber size: -60 C 1.5 x 1.75 x 2.2 m TR 2130:Issue B:1993-60 C 1 x 1 x 1.5 m -60 C 0.53 x 0.53 x 1.11 m DEF-STAN 07-55:1975 Tests B4, B5 NES 1004:Issue 1:1987 Data Sheet 8 MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 502 DEF-STAN 00-35: Issue 3 and 4 Test CL4 and CL5 Assessment Manager: CA Page 19 of 26

As listed on Pages 10 and 11 2.13 Low Temperature - at Low BS 2011:Z/AM:1977 Pressure (IEC 68-2-40:1976) Min temp: -60 C Max altitude: 95000 ft BS3G100:Part 2:Section 3: Chamber size: 1 x 1 x 1.5 m Sub-section 3.2:1970(1983) Test sample can be supplied with cooling air whilst DEF-STAN 07-55:1975 maintaining altitude conditions (max: 2 lbs/min at -45 C to +70 C) Test B12 MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Methods 500 and 504 MIL-STD-810 B DEF-STAN 00-35: Issue 3 and 4 Test CL12 2.14 Temperature Cycling BS3G100:Part 2:Section 3: including Thermal Shock Sub-section 3.15:1978 Max temp: 120 C Min temp: -60 C DEF-STAN 07-55:1975 Manual Transfer Only Above 10ºC/Minute is by manual transfer only Test B14 MIL-STD-810 B MIL-STD-810 G Method 503 RTCA DO-160 A Section 5 And EURCAE ED-14 equivalent Assessment Manager: CA Page 20 of 26

As listed on Pages 10 and 11 2.15 Corrosion - Salt BS 2011:Ka:1982 (High humidity) (IEC 68-2-11:1981) Max temp: 80 C Chamber size: BS 2011:Kb:1987 0.9 x 1.2 x 0.85 m (IEC 68-2-52:1996) TR 2130:Issue B:1993 ASTM B117-90:1990 DEF-STAN 07-55:1975 Test C2, C5 NES 1004:Issue 1:1987 Data Sheet 21 RTCA DO-160 A Section 14 And EURCAE ED-14 equivalent 2.16 Fine Mist DEF-STAN 07-55, Part 2, Section 4/1, Test D2 2.17 Rapid and Explosive BS3G100:Part 2:Section 3: Decompression Sub-section 3.4:1972 Chamber size: 0.25 x 0.4 x 0.75 m RTCA DO-160 A Section 4.6.2 And EURCAE ED-14 equivalent Assessment Manager: CA Page 21 of 26

As listed on Pages 10 and 11 2.17 Rapid and Explosive MIL-STD-810 D Decompression Chamber size: 0.25 x 0.4 x 0.75 m MIL-STD-810 G Method 500 SP-P-90033:Issue 7:para 6.19 DEF-STAN 00-35: Issue 3 and 4 Test CL9 2.18 Rain (driving) BS 2011:Rb:1990 Wind speed: 18 m/sec (IEC 68-2-18:1989) Max rainfall: 12 inch/hour Exposure area BS 4999:Part 105:1988 (exit of wind tunnel) Table IV, Test No 6 0.5 x 0.5 m BS 5490:1977 paras 8.5 and 8.6 TR 2130:Issue B:1993 EN 60529:1991 paras 14.2.5 and 14.2.6 DEF-STAN 07-55:1975 Test D3 NES 1004:Issue 1:1987 Data Sheet 18 RTCA DO-160 A Section 10.3.2 And EURCAE ED-14 equivalent Assessment Manager: CA Page 22 of 26

As listed on Pages 10 and 11 2.18 Rain (driving) MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 506:Proc 1 DEF-STAN 00-35: Issue 3 and 4 Test CL27 2.19 Immersion BS 2011:Rc1, Rc 2:1990 Tank size: 0.9 m x 0.9 m dia (IEC 68-2-18:1989) Max depth: 10 m (pressurised equivalent) TR 2130:Issue B:1993 DEF-STAN 07-55:1975 Test D5 Excluding severity G DEF 133:1963:para 15.3 Excluding severity G MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 512 DEF-STAN 00-35: Issue 3 and 4 Test CL29 excluding severity G 2.20 Over-Pressure Test DEF-STAN 07-55:1975 Max size: 0.9 m x 0.9 m dia Part 2:Section 2:Test B15 Max pressure: 4.1 bar Excluding severity F NES 1004:1987 Issue 1:Data Sheet 14 Excluding severity F Assessment Manager: CA Page 23 of 26

As listed on Pages 10 and 11 2.20 Over-Pressure Test RTCA DO-160 A Paragraph 4.6.3 And EURCAE ED-14 equivalent DEF-STAN 00-35:1999 Test CL15 excluding severity F 2.21 Water-Proofness (Drip) BS 2011:Ra:1990 Chamber max size: (IEC 68-2-18:1989) 1 m x 1.2 m BS3G100:Part 2:Section 3: Sub-section 3.11:1973 DEF-STAN 07-55:1975 Test D4 DEF-STAN 66.31:para 8.17 RTCA DO-160 A Paragraphs 10.3.1 and 10.3.2 And EURCAE ED-14 equivalent DEF-STAN 00-35: Issue 3 and 4 Test CL28 MIL-STD-810 B MIL-STD-810 D MIL-STD-810 G Method 506 Assessment Manager: CA Page 24 of 26

As listed on Pages 10 and 11 2.22 Fluid Contamination BS3G100:Part 2:Section 3: Max temp: 70 C Sub-section 3.12:1991 Chamber max size: 0.75 m x 0.75 m x 0.5 m DEF-133:Feb 1963:para 14.3 Fluid limited to non-toxic or Non-Hazardous materials RTCA DO-160 A Section 11 And EURCAE ED-14 equivalent DEF-STAN 00-35:1999 Test CN4 MIL-STD-810F:Method 504 2.23 Icing Test Section 24, Categories A, B, C And EURCAE ED-14 equivalent DEF-STAN 00-35: Part 3 Issue 4 Test CL10, Procedure A Assessment Manager: CA Page 25 of 26

Environmental Testing: Power supplies include: 20 kva, 3 phase, 400 Hz (200V phase to phase rotary generator) 30 kva, 3 phase, 50 Hz (415V phase to phase) 18 kva, single phase, variable frequency 6 kva, 3 phase, variable frequency 240V, 13A, single phase 50 Hz 28V, 100A DC Other DC voltages available Compressed air supply up to 100psi Note: Tests may be carried out to other specifications which are derived from, or are amalgamations of, those specifications on this Schedule. END Assessment Manager: CA Page 26 of 26