Chicago Roofing Contractors Association

Similar documents
November 10, 2015 Baltimore, MD. presented by

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

ILLINOIS SPECIFIC AMENDMENTS TO THE IECC 2015 EDITION

ORDINANCE NO. An ordinance amending Chapter 59, Dallas Energy Conservation Code, of the Dallas City

KEEPING UP WITH I-CODES

Michigan Energy Code Training and Implementation Program

Alternate Means and Materials for Code Compliance

Michigan Energy Code Training and Implementation Program

Building Enclosure Performance for Existing and New Buildings

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Energy Trigger (A Existing Building Upgrade Mechanism Model)

IECC Commercial Significant Changes Summary Tier I

2012 IECC Residential with State Adopted Changes

IRC 2012 Key Changes

2015 IECC Whole Building Air Leakage Compliance

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

The look and layout of the 2012 IECC changes. chapters 1-4 Commercial (CE) and. chapters 1-4 Residential (RE) 2011 Colorado Code Consulting, LLC 2

2012 International Energy Conservation Code for Simple Commercial Buildings

Boulder City NV Prepared by (Print Name) Signature Date

Hardin County Planning and Development Commission

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Moisture Considerations for Insulated Building Assemblies

Slab edge insulation is one of

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Chicago & IL Energy Code, Green, Garden Roofs, Energy and Drainage / Water Retention

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

Ontario s Building Code

BC BUILDING CODE ERRATA

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

SL175 Panel Technical Data Guide

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

ADMINISTRATION CHAPTER 1

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

RESIDENTIAL ENERGY EFFICIENCY

CRC / Chicago Center for Green Technology June 7, Chicago & IL Energy Code, Green, Garden Roofs, Energy and Drainage / Water Retention

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

2013 COMMERCIAL PRODUCTS

BUILDING ENERGY CODES UNIVERSITY

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

Integrated Air & Water Barrier Systems

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

SECTION PREPARATION FOR RE-ROOFING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

REPORT HOLDER: JOHNS MANVILLE TH STREET DENVER, COLORADO EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Beginning of the Course

Inspection of New One- and Two- Family Dwellings

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

Margaret Batts Tobin Laboratory

Continuous Insulation Systems for Exterior Walls

Single Family Residence Building Permits

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

CHAPTER 26 PLASTIC SECTION 2601 SECTION 2603 GENERAL FOAM PLASTIC INSULATION

Florida HERO Program Residential Eligible Product List All Products

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges

CHANGES TO THE US ENERGY CODES COMMERCIAL & RESIDENTIAL

Rhode Island Commercial Codes FAQs

Thermasheath-XP. Insulation for Exposed Use

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

Thermal Bridging in Residential Construction

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SES FOAM

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

Questar ThermWise Duct Technical Specifications

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Chapter 2: Foundation

DuPont RainVent Batten Installation Guidelines

HPW Protocol Reference Manual

Recommended Amendments to the 2012 International Residential Code (IRC)

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Transcription:

Chicago Roofing Contractors Association CSI Chicago Specifiers Roundtable CRCA Report Illinois 1/1/2013 Adoption ICC s 2012 International Energy Conservation Code Bill McHugh, CRCA Executive Director & Jason Wilen, NRCA Director, Technical Services

CRCA Members are Involved... Education Energy, Insurance, Safety, Codes Relationships - Luncheons Celebrate Students Scholarship Contractors, Manufacturers, Distributors, Consultants, Others

CRCA Members are Involved... IL Licensed Contractors, By-Law Committees Safety OSHA Alliance Steep & Shingle Industry Affairs @ ICC, City of Chicago, State of IL IL Department of Professional & Financial Regulation Website Listing @ CRCA.org.

Licensing Professional Roofing Contractors CRCA at RCI CAC Membership means Value Website Listing @ CRCA.org Seminars OSHA, City of Chicago Directory Listing Membership Meetings

Professional Roofing Contractor s Life The Life of the Roofing Contractor Technical Issues Comply with. Wind, Weight, Ventilation, Underlayment, Insulation, Drainage Workforce Education & Safety Culture Insurance Required WC, GL FOR ROOFING WORK Warranty Licensing Limited / Unlimited Specification Sections Division 07 International Building Code Chapter 15, 11, International Residential Code Chapter 9 International Energy Conservation Code 2009 STATE LAW International Green Construction Code - 2012 International Fire Code Installed Cost Competitive Market CRCA Members - Experience, Safety Culture, Value

6

CRCA Members One Call, Single Source Responsibility

CRCA Meetings in Springfield w/cdb, DCOE. CRCA Representatives Industry Affairs & President, Vice President, Executive Director, Legislative Consultant State of IL Lisa Mattingly Chair, CDB Bruce Selway Dept. of Commerce & Economic Opportunity Darren Myers, International Energy Code Consultants, consulting to CDB 8

2012 IL ACTIONS by CRCA Feb. - CRCA Participated in IL Energy Advisory Council Teleconference Feb. - CRCA Petition sent to IL Energy Advisory Council..referred to Joint Committee on Administrative Rules (JCAR), CDB as facilitator June - CRCA Comments to JCAR Oct. - CRCA Meets with CDB representatives Nov. - CRCA Supports Clarifications as submitted by CDB Jan. 2013 Final Clarifications 9

Commercial & Residential Buildings - IECC Insulation Increased 15% improvement over 2009 IECC 30% Improvement over 2006 IECC NEW Air Barrier Requirement Skylights for large spaces, 15 Ceilings ASHRAE 90.1-2010 references Much more 10

Commercial & Residential Buildings - Insulation IECC Insulation Commercial, Low Slope, +30% 2006 R-15 2009 R-20 2012 R-25 IECC Insulation Residential, +39% or +22% 2006 - R-38, (but R-30 Deemed to Comply?) 2009 - R-38 2012 R-49 11

Commercial Buildings General Air Barrier Required in New Construction & Existing Buildings Required in Residential Construction more later. Insulation Increases IECC 2009 from R-20 to IECC 2012 R-25 Reflectivity Chicago. Suburbs & Downstate? 12

What s an Air Barrier?? AIR BARRIER. Material(s) assembled and joined together to provide a barrier to air leakage through the building envelope. An air barrier may be a single material or a combination of materials. 13

C402.4.1.1 Air barrier construction. The continuous air barrier shall be constructed to comply with the following: 1. The air barrier shall be continuous for all assemblies that are the thermal envelope of the building and across the joints and assemblies. 2. Air barrier joints and seams shall be sealed, including sealing transitions in places and changes in materials. Air barrier penetrations shall be sealed in accordance with Section C402.4.2. The joints and seals shall be securely installed in or on the joint for its entire length so as not to dislodge, loosen or otherwise impair its ability to resist positive and negative pressure from wind, stack effect and mechanical ventilation. 3. Recessed lighting fixtures shall comply with Section C404.2.8. Where similar objects are installed which penetrate the air barrier, provisions shall be made to maintain the integrity of the air barrier. Exception: Buildings that comply with Section C402.4.1.2.3 are not required to comply with Items1 and 3. 14

C402.4.1.2 Air barrier compliance options. A continuous air barrier for the opaque building envelope shall comply with Section C402.4.1.2.1, C402.4.1.2.2, or C402.4.1.2.3. C402.4.1.2.1 Materials. Materials with an air permeability no greater than 0.004 cfm/ft2 (0.02 L/s m2) under a pressure differential of 0.3 inches water gauge (w.g.) (75 Pa) when tested in accordance with ASTM E 2178 shall comply with this section. Materials in Items 1 through 15 shall be deemed to comply with this section provided joints are sealed and materials are installed as air barriers in accordance with the manufacturer s instructions. 15

C402.4.1.2 Air barrier compliance options. A continuous air barrier for the opaque building envelope shall comply with Section C402.4.1.2.1, C402.4.1.2.2, or C402.4.1.2.3. Materials - Deemed to Comply Testing of Assembly Testing of Whole Building 16

shall be deemed to comply: 1. Plywood no < 3/8 inch (10 mm) 2. OSB board no < 3/8 inch (10 mm). 3. Extruded polystyrene insulation board no< 1/2 inch. 4. Foil-back polyisocyanurate insulation board no < 1/2 inch 5. Closed cell spray foam min. density 1.5 pcf no < 1-1/2 6. Open cell spray foam w/density between 0.4 and 1.5 pcf. and having a thickness of not less than 4.5. 7. Exterior or interior gypsum board no < ½. 8. Cement board having no < ½. 17

shall be deemed to comply: 9. Built up roofing membrane. 10. Modified bituminous roof membrane. 11. Fully adhered single-ply roof membrane. 12. A Portland cement/sand parge, or gypsum plaster no < 5/8 inch (16 mm). 13. Cast-in-place and precast concrete. 14. Fully grouted concrete block masonry. 15. Sheet steel or aluminum. 18

C402.4.1.2.2 Assemblies. Assemblies of materials and components comply... - Average air leakage - Not to exceed 0.04 cfm/ft2 (0.2 L/s m2) under a pressure differential of 0.3 inches of water gauge (w.g.)(75 Pa) when tested in accordance with ASTM E 2357, ASTM E 1677 or ASTM E 283 shall comply with this section. - Assemblies listed in Items 1 and 2 shall be deemed to comply provided joints are sealed and requirements of Section C402.4.1.1 are met. 1. Concrete masonry walls coated with one application either of block filler and two applications of a paint or sealer coating; 2. A Portland cement/sand parge, stucco or plaster minimum 1/2 Inch (12 mm) in thickness. 19

C402.4.1.2.3 Building test. The completed building shall be tested to comply. - Air leakage rate of the building envelope - shall not exceed 0.40 cfm/ft2 0.3 inches water gauge (2.0 L/s m2 at 75 Pa) pressure, ASTM E 779 - or an equivalent method approved by the code official 20

- R - Residential Requirements. 21

Residential Air Barrier Requirements. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.4. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer s instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. 22

Residential Air Barrier Requirements Compliance R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. 23

During blower testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. 24

Back to Commercial Buildings Reflectivity, Thermal Emittance Insulation Air Barrier 25

Jason P. Wilen, AIA CDT RRO Director, Technical Services National Roofing Contractors Association 10255 West Higgins Road, Suite 600 Rosemont, IL 60018-5607 (847) 299-9070 x7572 1-800-323-9545 FAX: (847) 299-1183 E-mail: jwilen@nrca.net Web site: www.nrca.net

IECC 2012 vs. ASHRAE 90.1-2010 Alternate Compliance Path (Commercial) IECC 2012 Section C401.2 Application, Item One: ANSI/ASHRAE/IESNA 90.1 Early printings of IECC 2012 incorrectly listed ASHRAE 90.1-2007 Correct Edition: ASHRAE 90.1-2010 (August 11, 2011 Errata)

IECC 2012 vs. ASHRAE 90.1-2010 Minimum Required R-values- Zone 5 Insulation Entirely Above Deck IECC 90.1 All Occupancies Semiheated R-25ci N/A R-20ci R-7.6

IECC 2012 vs. ASHRAE 90.1-2010 Minimum Required R-values- Zone 5 Metal Buildings IECC 90.1 All Occupancies Semiheated R-19+R11LS N/A R-13+R-13 R-13

IECC 2012 vs. ASHRAE 90.1-2010 Minimum Required R-values- Zone 5 Attic and Other IECC 90.1 All Other Group R Semiheated R-38 R-49 N/A R-38 R-38 R-19

IECC 2012 vs. ASHRAE 90.1-2010 Other Notable Roofing-related Differences 90.1 allows 5% of roof area (vs. 3%) to be skylights in some situations Both documents require skylights for daylighting in some situations. 90.1 requires them in more situations.

IECC 2012 vs. ASHRAE 90.1-2010 Other Notable Roofing-related Differences 90.1 does not list open-cell spray foam insulation as a deemed to comply air barrier. IECC does (4 ½ min. thickness at a density between 0.4 and 1.5 pcf) 90.1 does not contain a provision for whole building testing of the air barrier (ASTM E779). IECC does

IECC 2012 vs. ASHRAE 90.1-2010 Other Notable Roofing-related Differences Must follow one for the whole building (no pick-and-choose ) Especially important for projects with a scope that includes parts of the building in addition to the roof

NRCA Publication Guidelines for Complying with Energy Code Requirements for Roof Assemblies IECC 2009 and ASHRAE 90.1 2007 IECC 2012 and ASHRAE 90.1 2010 Co-published with ICC

Jason P. Wilen, AIA CDT RRO Director, Technical Services National Roofing Contractors Association 10255 West Higgins Road, Suite 600 Rosemont, IL 60018-5607 (847) 299-9070 x7572 1-800-323-9545 FAX: (847) 299-1183 E-mail: jwilen@nrca.net Web site: www.nrca.net

C402.2.1.1 Roof solar reflectance and thermal emittance. Low-sloped roofs, with a slope less than 2 units vertical in 12 horizontal, directly above cooled conditioned spaces in Climate Zones 1, 2, and 3 shall comply with one or more of the options in Table C402.2.1.1. 36

Reflectivity---not suburbs, but. Chicago Urban Heat Island Ordinance Initial Solar Reflectance -.72 Three Year Aged Reflectance -.5 Cool Roof Rating Council Energy Star Exceptions Ballasted Roofs - 15lbs. Garden Roofs Photovoltaic Panels 37

IECC 2012 State of IL Clarifications Existing Buildings Reroofing Roof Recover Roof Replacement Roof Repair 38

IBC Ch. 2 Definitions ROOF ASSEMBLY (For application to Chapter 15 only). A system designed to provide weather protection and resistance to design loads. The system consists of a roof covering and roof deck or a single component serving as both the roof covering and the roof deck. A roof assembly includes the roof deck, vapor retarder, substrate or thermal barrier, insulation, vapor retarder and roof covering. ROOF COVERING. The covering applied to the roof deck for weather resistance, fire classification or appearance. ROOF COVERING SYSTEM. See Roof assembly. 39

IBC Ch. 2 Definitions REROOFING. The process of recovering or replacing an existing roof covering. See Roof recover and Roof replacement. ROOF RECOVER. The process of installing an additional roof covering over a prepared existing roof covering without removing the existing roof covering. ROOF REPAIR. Reconstruction or renewal of any part of an existing roof for the purposes of its maintenance. ROOF REPLACEMENT. The process of removing the existing roof covering, repairing any damaged substrate and installing a new roof covering. 40

Most Questions IBC / IECC - What if we Tear off only the roof covering? Tear off a few squares? Peel off & install new roof covering? Other modification Do we need to upgrade insulation? Specifier Answer? 41

C101.4.3 Additions, alterations, renovations or repairs. Additions, alterations, renovations or repairs to an existing building, building system or portion thereof shall conform to the provisions of this code as they relate to new construction without requiring the unaltered portion(s) of the existing building or building system to comply with this code. Additions, alterations, renovations or repairs shall not create an unsafe or hazardous condition or overload existing building systems. An addition shall be deemed to comply with this code if the addition alone complies or if the existing building and addition comply with this code as a single building. 42

Exception: The following need not comply provided the energy use of the building is not increased: 1. Storm windows installed over existing fenestration. 2. Glass only replacements in an existing sash and frame. 3. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation. 4. Construction where the existing roof, wall or floor cavity is not exposed. 5. Reroofing for roofs where neither the sheathing nor the insulation is exposed. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. 43

Exception: The following need not comply provided the energy use of the building is not increased: 6. Replacement of existing doors that separate conditioned space from the exterior shall not require the installation of a vestibule or revolving door, provided, however, that an existing vestibule that separates a conditioned space from the exterior shall not be removed, 7. Alterations that replace less than 50 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. 8. Alterations that replace only the bulb and ballast within the existing luminaires in a space provided that the alteration does not increase the installed interior lighting power. 44

Commercial Buildings State of IL, Air Barrier Clarification issues pertaining to reroofing, roof recover, roof replacement defined by the IBC, the Illinois Energy Conservation Code, and the 2012 IECC, only items altered or affected by alterations, renovations or repairs to an existing building are required to conform to the provisions of the code as they relate to new construction. 45

Commercial Buildings Air Barrier Clarification Note there are several Exceptions (1-8) itemized in Section C101.4.3 which permit a degree of compliance subject to approval of the code official. With respect to reroofing (Exception 5), the 2012 IECC considers work affecting roofing insulation an alteration to the building. 46

Commercial Buildings Air Barrier Clarification A roofing membrane, however, is considered a roof covering, and as such, is subject to only to the construction requirements of the Building Code of the jurisdiction, likely Chapter 15 of the IBC. 47

Commercial Buildings Air Barrier Clarification Therefore, work considered reroofing or roof recovering is not subject to the provisions of Section C402.4.1, provided the existing insulation level is unaltered (i.e., unmodified). 48

Commercial Buildings Air Barrier Clarification.The provisions of both the 2012 IECC with respect to alterations and repairs affecting the building thermal envelope, and the IBC specific to alterations and repairs affecting building roof coverings are coordinated in this regard. 49

Commercial Buildings Air Barrier Clarification Put simply, no continuous Air Barrier is required when the extent of work is limited solely to reroofing, roof recover, roof replacement as defined by the IBC, and the Exceptions (1-8) itemized in Section C101.4.3, which permit a degree of compliance subject to approval of the code official. State of IL Website http://www.ildceo.net/dceo/bureaus/energy_recyc ling/faq-2.htm 50

Commercial Buildings Existing Buildings Insulation Clarification The use of ASHRAE Standard 90.1-2010 as an alternative compliance path for commercial buildings is permitted. 51

Commercial Buildings Existing Buildings Insulation Clarification Table 5.5-5 of Standard 90.1 allows commercial roofs in Illinois, with insulation entirely above deck, to be insulated to R-20 in lieu or the 2012 IECC requirement for R-25. Therefore, both paths to compliance (IECC or ASHRAE Standard 90.1) are recognized compliance options. 52

Commercial Buildings - Insulation Table 5.5-5 of Standard 90.1 allows commercial roofs in Illinois, with insulation entirely above deck, to be insulated to R-20 in lieu or the 2012 IECC requirement for R-25. Does this mean if we only peel the membrane off we have to upgrade from R-15 to R-20?? 53

State of IL Website - Clarifications JAN. 18 General - http://www.ildceo.net/dceo/bureaus/energy_ Recycling/FAQ-index.htm Roofing Related http://www.ildceo.net/dceo/bureaus/energy_ Recycling/FAQ-2.htm 54

55

Chicago Roofing Contractors Association CRCA Report Illinois 1/1/2013 Adoption ICC s 2012 International Energy Conservation Code Bill McHugh, CRCA www.crca.org ~ bill@crca.org

Chicago Roofing Contractors Association CRCA Trade Show & Seminars Jan. 23-24, 2014 Drury Lane Conference Center Oakbrook Terrace, IL www.crca.org