DECLARATION OF PERFORMANCE

Similar documents
RMANCE ROCKPANEL. EL Durable 8 mm. System 1. inorganic finish. Konstruktieweg. Tel. Fax. Notified. Body: 1. Unique. 4. System as set.

European Technical Assessment ETA-07/0141 of 15/12/2014

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

European Technical Assessment ETA-09/0156 of 18/12/2015

European Technical Assessment ETA-10/0422 of 08/01/2016

European Technical Assessment ETA-11/0518 of 19/08/2015

European Technical Assessment ETA-17/0741 of 29/08/2017

European Technical Assessment ETA-10/0124 of 29/04/2016

European Technical Assessment ETA-12/0578 of 2014/04/01

European Technical Assessment ETA-13/1077 of

European Technical Assessment ETA-14/0392 of 04/12/2014

European Technical Assessment ETA-17/0346 of 07/06/2017

European Technical Assessment ETA-10/0415 of 25/02/2016

Declaration of Performance No. SUI/PP/13/CE2+ Product Type 9mm 12mm 15mm 18mm 21mm 24mm 27mm 30mm

European Technical Assessment ETA-16/0952 of 06/01/2017

European Technical Assessment. ETA-11/0372 of Member of. General part

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Declaration of Performance

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

European Technical Assessment. ETA-11/0135 of Member of. General part

European Technical ETA 06/0238 Assessment of 31/08/2017

Tehnical Data Sheet Astro HS FM Compound. UIC of product-type: HSFMC CPR-JA5013 ETA-14/0047. ETAG 026-Part 1 ETAG 026-Part 2

European Technical Assessment ETA-16/0865 of 08/11/2016

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

European Technical Approval ETA 09/0250

HP Partial Fill. Robust, long-lasting protection

European Technical Assessment ETA-15/0288 of 17/06/2015

ETA-07/0291 of 30/06/2014. European Technical Assessment. Draft. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

Benefits of hard foam PVC. What are Durasid sidings?

DECLARATION OF PERFORMANCE

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

Heat insulated fabrication GRC panel

Data Sheet 3611 Englisch

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

European Technical Assessment ETA-14/0453 of 11/12/2014

FIBRANgeo R-050. Stonewool Insulation Roll. Product Description. Advantages TECHNICAL DATA SHEET

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

European Technical Approval ETA-13/0689

Gold Bond BRAND Gypsum Sheathing

Phenolic foam thermal insulation products for buildings and building services end use applications

Sandwich panel SPA Product description

RUUKKI FORMA DESIGN INSTRUCTION

ETAG 034. GUIDELINE FOR EUROPEAN TECHNICAL APPROVAL of KITS FOR EXTERNAL WALL CLADDINGS

EN DK NA:2007

This European technical approval

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

European Technical Approval ETA 13/0874

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

European Technical Assessment ETA-15/0362

Technical Data Sheet StoLevell Duo plus

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

think eco WOOD BOARD Bahan Binaan KELASʻOʼ

European Technical Approval No. ETA-12/0056

Certificate of Assessment

Magnesium Oxide Wallboard

Assessment Number BTC 14254FA

ETAG 018 FIRE PROTECTIVE PRODUCTS PART 2: REACTIVE COATINGS FOR FIRE PROTECTION OF STEEL ELEMENTS

European Technical Assessment ETA 14/0075 of 14/04/2014

European Technical Assessment. ETA-16/0320 of Member of. General part

HOLLOW CORE FLOORS SPEED AND STRENGTH

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

FIBRANgeo BP 50. Rigid Stonewool insulation board with knit fibres. Product Description. Advantages TECHNICAL DATA SHEET

European Technical Assessment ETA-14/0454 of 11/12/2014

CERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED

European Technical Approval No. ETA-08/0285

SUITABILITY: SMARTPLY OSB3 - ZERO ADDED FORMALDEHYDE

EUROPEAN TECHNICAL APPROVAL

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

ALPOLIC /fr LT. Technical Manual. Section 2 Characteristics. Contents

REPORT STATUS: DATE: Report n :

Insulating systems used in agricultural and industrial buildings

Fixations dans les maçonneries

Renovation of Buildings using Steel Technologies (ROBUST)

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD REFLECTIVE

BRE Global Assessment Report

European Technical Assessment. ETA 17/0154 of 27/03/2017. ALSAN Flashing quadro. Liquid applied roof waterproofing kit on the basis of plyurethane

European Technical Approval

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

European Technical Approval ETA-11/0083

FACADE PROFILES FOR VERSATILE APPLICATIONS 01/16

Ask for FSC certified products. Ask for PEFC certified products.

Technical Data Sheet Sto-RFP

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

BDA Agrément BAR /01/C

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

European Technical Approval No. ETA-06/0251 (Replaces the version valid from

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

EasylationWall. External Wall Insulation System. bringing european innovation

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

June Residential New Build Render and cladding walls

BDA Agrément BAW /01/C

Product Data Sheet. QuadCore Karrier. Applications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

Transcription:

ROCKWOOL B.V. / ROCKPANEL Group Konstruktieweg 2 NL-6045 JD Roermond www.rockpanel.com DECLARATION OF PERFORMANCE No. 0764-CPR-0249 UK vs01 1. Unique identification code of the product-type: ROCKPANEL PLY 6 mm, 8 mm and 10 mm supplied with a primer coating 2. Intended use / es: External cladding for walls, fascias, soffits and ceilings 3. Manufacturer: ROCKWOOL B.V. / ROCKPANEL Group Konstruktieweg 2 NL-6045 JD Roermond Tel. +31 475 353 000 Fax +31 475 353 550 4. System or systems of AVCP (assessment and verification of constancy of performance of the construction product) as set out in Annex V (amended by : OJ L 157, 27.5.2014, p. 76 79) System 1 5. European Assessment Document: EAD 090001-00-0404 for Prefabricated compressed mineral wool boards with organic or inorganic finish and with specified fastening system, edition May 2015. European Technical Assessment: ETA-13/0019 of 2015-11-03 Technical Assessment Body: ETA-Danmark A/S Göteburg Plads 1, DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Notified Body: Materialprüfanstalt für das Bauwesen Nienburger Strasse 3, D-30167 Hannover Notified Body 0764 Tel. +49 511 762 3104 Fax +49 511 762 4001 Internet www.mpa-bau.de/ and issued: Certificate of Constancy of performance No. 0764 - CPR 0249 Page 1 of 12

6. Characteristics of the product The ROCKPANEL PLY panels are surface treated with a four-layer water-borne polymer emulsion primer on one side, in a grey colour. The physical properties of ROCKPANEL PLY 6 mm, 8 mm and 10 mm are indicated below: - thickness 6 ± 0.3 mm, 8 ± 0.5 mm, 10 ± 0.5 mm - length, max 3050 mm - width, max 1250 mm - density nominal 1000-100 / +150 kg/m³ - bending strength length and width f 05 15 N/mm² - Modulus of Elasticity m(e) = 3065 N/mm² - Thermal conductivity 0.35 W/(m.K) Clause 7 contains the performances of ROCKPANEL PLY 6 mm, 8 mm and 10 mm. Page 2 of 12

7. Declared performance s Basic Requirements for construction works BR2 - Safety in case of fire Performance 1 - Euroclass classification of different constructions with ROCKPANEL PLY boards Fixing method mechanically fixed Ventilated or non-ventilated Non-ventilated. Cavity filled with mineral wool Ventilated with EPDM gasket on the battens [a] Ventilated with 6 mm ROCKPANEL PLY strips on the battens [b] [a] width of the gasket 15 mm at both sides wider than the batten [b] width of the strip 15 mm at both sides wider than the batten vertical wooden subframe PLY in the thicknesses 6 mm 8 mm 10 mm B-s2,d0 B-s2,d0 open 6 mm horizontal joint closed 6 mm horizontal joint B-s2,d0 open 6 mm horizontal joint ETA-13/0019 EN 13501-1:2007+A1:2009 Field of application The following field of application applies. Euroclass classification The classification mentioned in 1 is valid for the following end use conditions: Mounting Mechanically fixed to a wooden subframe The panels are backed with min. 50 mm mineral wool insulation with density 30-70 kg/m³ according to EN 13162 with a cavity between the panels and the insulation (mechanically fixed) The boards are backed with min. 40 mm mineral wool insulation with density 30-70 kg/m³ according to EN 13162 without a cavity between the back of the board and the insulation behind the subframe (mechanically fixed non ventilated) Substrates: Concrete walls, masonry walls Page 3 of 12

Insulation: Ventilated constructions: The battens are backed with min. 50 mm mineral wool insulation with density 30-70 kg/m³ according to EN 13162 with a cavity of min. 28 mm between the panels and the insulation Non-ventilated constructions: The panels are backed with min. 40 mm mineral wool with density 30-70 kg/m³ according to EN 13162 between the battens and min. 50 mm with density 30-70 kg/m³ behind the battens without a cavity Results are also valid for all greater thickness of mineral wool insulation layer with the same density and the same or better reaction to fire classification The test result of a test with mineral wool insulation shall be valid, without test, for the same type of panel used without insulation, if the substrate chosen according to EN 13238 is made of panel with Euro-class A1 or A2 (e.g. fibres-cement panel). Subframe: Vertical softwood battens without fire retardant treatment, thickness minimum 28 mm Test results are also valid for the same type of panel with aluminum or steel frame Test results are also valid for the same type of panel with vertical LVL battens, without fire retardant treatment, thickness minimum 27 mm Fixings: Results are also valid with higher density of the fixing devices Test results are also valid for the same type of panel fixed by rivets made of the same material of screws and vice versa Cavity: Unfilled or filled with insulation of stone wool with a nominal nominal density of 30-70 kg/m 3 The depth of the cavity is minimum 28 mm Test results are also valid for other higher thickness of air space between the back of the board and the insulation of the subframe Joints: Vertical joints are with an EPDM foam gasket backing (Celdex EPDM Soft EP-4530) or ROCKPANEL strip backing as described in 1 and horizontal joints can be open (ventilated constructions) or with an aluminum profile (ventilated and non-ventilated constructions) Test results are also valid for higher thicknesses of ROCKPANEL strips Test results are also valid in the case of using ROCKPANEL strips instead of EPDM foam gaskets The result from a test with an open horizontal joint is also valid for the same type of panel used in applications with horizontal joints closed by steel or aluminum profiles The classification is also valid for the following product parameters: Thickness: Nominal 6 mm, individual tolerances ± 0.3 mm Nominal 8 mm, individual tolerances ± 0.5 mm Nominal 19 mm, individual tolerances ± 0.5 mm Density: Nominal 1000 kg/m 3, individual tolerances -100 / +150 kg/m 3 Page 4 of 12

s BR3 Hygiene, health and environment 2 - Performance - Water vapour permeability and water permeability Property Declared values PLY 6, 8 and 10 mm: s d = 1.2 m at 23 C and 85 %RH ETA-13/0019 Water vapour permeability The designer shall consider the relevant needs for ventilation, heating and EN ISO 12572 test condition B insulation to minimise condensation in service. Water tightness of joints NPD No performance determined ETA-13/0019 s BR 3 Hygiene, health and environment 3 - Performance - Release of dangerous substances Property Product Use category: Outdoor S/W2 The kit does not contain/release dangerous substances specified in TR 034, dated April 2013*), except Content, emission and/or release Formaldehyde concentration 0,0105 mg/m 3 Formaldehyde class E1 of dangerous substances The used fibres are not potential carcinogenic No biocides are used in the ROCKPANEL boards No flame retardant is used in the boards Page 5 of 12 ETA-13/0019 No cadmium is used in the boards. *) In addition to the specific clauses relating to dangerous substances contained in this European technical Assessment, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the Construction Products Regulation, these requirements need also to be complied with, when and where they apply. 4a - Performance - Design value of the axial load for mechanical fixing 6 mm PLY boards For service class 2 (see Note ) and load-duration class Instantaneous [c] Property 6 mm boards Span in mm [b] X d = X k / M in N a fixing b board Middle / Edge / Corner 400 400 C18 / C24 [d]: 204 / 104 / 58 A1 [c] Design value of BR 4 Safety the axial load 400 400 C18 / C24 [d] : 204 / 104 / 58 A2 [c] with the use of 6 mm ROCKPANEL strips X d = X k / M nail fixing (32 mm) [e] 300 400 C18 / C24 [d] : 100 / 67 / 64 B1 [c] nail fixing (40 mm) [e] with the use of 300 400 C18 / C24 [d] : 100 / 67 / 64 B2 [c] ROCKPANEL strips 6 mm [c] k mod = 1,10 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 2 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses where member is protected from direct wetting ] and load-duration class Instantaneous [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] ETA-13/0019 EN 14592:2008+A1:2012 (E) Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 2 is characterised by a moisture content in the materials corresponding to a temperature of 20 C and the relative humidity of the surrounding air only exceeding 85 % for a few weeks per year. In service class 2 the average moisture content in most softwoods will not exceed 20 %.

4b - Performance - Design value of the axial load for mechanical fixing 6 mm PLY boards For service class 3 (see Note ) and load-duration class Instantaneous [c] Property 6 mm boards Span in mm [b] X d = X k / M in N a fixing b board Middle / Edge / Corner 400 400 C18 / C24 [d] : 204 / 104 / 58 A1 [c] Design value of BR 4 Safety the axial load 400 400 C18 / C24 [d] : 204 / 104 / 58 A2 [c] with the use of 6 mm ROCKPANEL strips X d = X k / M nail fixing (32 mm) [e] 300 400 C18 / C24 [d] : 100 / 67 / 64 B1 [c] nail fixing (40 mm) [e] with the use of 300 400 C18 / C24 [d] : 100 / 67 / 64 B2 [c] ROCKPANEL strips 6 mm [c] k mod = 0,90 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 3 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses fully exposed ] and load-duration class Instantaneous [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] ETA-13/0019 EN 14592:2008+A1:2012 (E) Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 3 is characterised by climatic conditions leading to higher moisture contents than in service class 2 (compare Note in 4a). 4c - Performance - Design value of the axial load for mechanical fixing 6 mm PLY boards For service class 2 (see Note ) and load-duration class Permanent [c] Property 6 mm boards Span in mm [b] X d = X k / M in N a fixing b board Middle / Edge / Corner Design value of BR 4 Safety the axial load with the use of 6 mm ROCKPANEL strips X d = X k / M nail fixing (32 mm) [e] nail fixing (40 mm) [e] with the use of ROCKPANEL strips 6 mm [c] k mod = 0,60 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 2 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses where member is protected from direct wetting ] and load-duration class Permanent [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] 400 400 C18 / C24 [d ] : 204 / 104 / 58 A1 [c] 400 400 C18 / C24 [d ] : 204 / 104 / 58 A2 [c] 300 400 C18 / C24 [d ] : 100 / 67 / 64 B1 [c] 300 400 C18 / C24 [d ] : 100 / 67 / 64 B2 [c] ETA-13/0019 EN 14592:2008+A1:2012 (E) Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 2 is characterised by a moisture content in the materials corresponding to a temperature of 20 C and the relative humidity of the surrounding air only exceeding 85 % for a few weeks per year. In service class 2 the average moisture content in most softwoods will not exceed 20 %. Page 6 of 12

BR 4 Safety 4d - Performance - Design value of the axial load for mechanical fixing 8 mm PLY boards For service class 2 (see Note ) and load-duration class Instantaneous [c] Property 8 mm boards Span in mm [b] X d = X k / M in N Design value of the axial load X d = X k / M nail fixing (32 mm) [e] a fixing b board Middle / Edge / Corner [c] k mod = 1,10 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 2 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses where member is protected from direct wetting ] and load-duration class Instantaneous [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] BR 4 Safety 4e - Performance - Design value of the axial load for mechanical fixing 8 mm PLY boards For service class 3 (see Note ) and load-duration class Instantaneous [c] Property 8 mm boards Span in mm [b] X d = X k / M in N Design value of the axial load X d = X k / M nail fixing (32 mm) [e] 500 500 C18/C24[d]: 321 / 215 / 111 A3 [c] ETA-13/0019 400 500 C18/C24[d]: 88 / 106 / 97 B3 [c] EN 14592:2008+A1:2012 (E) a fixing Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 2 is characterised by a moisture content in the materials corresponding to a temperature of 20 C and the relative humidity of the surrounding air only exceeding 85 % for a few weeks per year. In service class 2 the average moisture content in most softwoods will not exceed 20 %. b board Middle / Edge / Corner 500 500 C18/C24 [d] : 321 / 215 / 111 A3 [c] ETA-13/0019 400 500 C18/C24 [d] : 88 / 106 / 97 B3 [c] EN 14592:2008+A1:2012 (E) [c] k mod = 0,90 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 3 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses fully exposed ] and load-duration class Instantaneous [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 3 is characterised by climatic conditions leading to higher moisture contents than in service class 2 (compare Note in 4d). Page 7 of 12

BR 4 Safety 4f - Performance - Design value of the axial load for mechanical fixing 8 mm PLY boards For service class 2 (see Note ) and load-duration class Permanent [c] Property 8 mm boards Span in mm [b] X d = X k / M in N Design value of the axial load X d = X k / M nail fixing (32 mm) [e] a fixing b board Middle / Edge / Corner 500 500 C18/C24 [d ] : 321 / 215 / 111 A3 [c] ETA-13/0019 400 500 C18 [d ] : 77 / 77 / 77 C24 [d] : 88 / 93 / 93 [c] k mod = 0,60 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 2 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses where member is protected from direct wetting ] and load-duration class Permanent [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] BR 4 Safety 4g - Performance - Design value of the axial load for mechanical fixing 10 mm PLY boards For service class 2 (see Note ) and load-duration class Instantaneous [c] Property 10 mm boards Span in mm [b] X d = X k / M in N Design value of the axial load X d = X k / M nail fixing (40 mm) [e] a fixing B3 [c] EN 14592:2008+A1:2012 (E) Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 2 is characterised by a moisture content in the materials corresponding to a temperature of 20 C and the relative humidity of the surrounding air only exceeding 85 % for a few weeks per year. In service class 2 the average moisture content in most softwoods will not exceed 20 %. b board Middle / Edge / Corner [c] k mod = 1,10 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 2 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses where member is protected from direct wetting ] and load-duration class Instantaneous [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] 600 600 C18/C24 [d]: 249 / 223 / 119 A4 [c] ETA-13/0019 500 600 C18/C24 [d] : 78 / 66 / 64 B4 [c] EN 14592:2008+A1:2012 (E) Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 2 is characterised by a moisture content in the materials corresponding to a temperature of 20 C and the relative humidity of the surrounding air only exceeding 85 % for a few weeks per year. In service class 2 the average moisture content in most softwoods will not exceed 20 %. Page 8 of 12

BR 4 Safety 4h - Performance - Design value of the axial load for mechanical fixing 10 mm PLY boards For service class 3 (see Note ) and load-duration class Instantaneous [c] Property 10 mm boards Span in mm [b] X d = X k / M in N Design value of the axial load X d = X k / M nail fixing (40 mm) [e] a fixing b board Middle / Edge / Corner 600 600 C18/C24 [d] : 249 / 223 / 119 A4 [c] ETA-13/0019 500 600 C18/C24 [d] : 78 / 66 / 64 B4 [c] EN 14592:2008+A1:2012 (E) [c] k mod = 0,90 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 3 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses fully exposed ] and load-duration class Instantaneous [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] BR 4 Safety 4i - Performance - Design value of the axial load for mechanical fixing 10 mm PLY boards For service class 2 (see Note ) and load-duration class Permanent [c] Property 10 mm boards Span in mm [b] X d = X k / M in N Design value of the axial load X d = X k / M nail fixing (40 mm) [e] a fixing Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 3 is characterised by climatic conditions leading to higher moisture contents than in service class 2 (compare Note in 4g). b board Middle / Edge / Corner [c] k mod = 0,60 in accordance with 3.1 Values of k mod BS EN 1995-1-1:2004+A1:2008; For service class 2 [NA to BS EN 1995-1-1:2004+A1:2008 NA.2 External uses where member is protected from direct wetting ] and load-duration class Permanent [ NA.1 NA to BS EN 1995-1-1:2004+A1:2008] 600 600 C18/C24 [d ] : 249 / 223 / 119 A4 [c] ETA-13/0019 500 600 C18/C24 [d] : 78 / 66 / 64 B4 [c] EN 14592:2008+A1:2012 (E) Note (according to BS EN 1995-1-1:2004+A1:2008 2.3.1.3 (3)P ): Service class 2 is characterised by a moisture content in the materials corresponding to a temperature of 20 C and the relative humidity of the surrounding air only exceeding 85 % for a few weeks per year. In service class 2 the average moisture content in most softwoods will not exceed 20 %. Page 9 of 12

5 Performance mechanical fixings : hole diameters for Durable boards Board dimension Fixing type [a] Fixed hole Moving hole Slotted hole considered Screw 3.2 5.5 4.4 * 5.5 1200 * 3050 ETA-13/0019 issued BR4 Safety Nail 2.5 4.0 2.8 * 4.0 1200 * 2300 [b] 2015-11-03, 10 [a] for s fixings see table 8 [b] a larger panel length requires a larger hole and head diameter 6 Performance fixings according to table 4 and 5 with the required edge distances, maximum distances and fixing method a 1 b b a 1 Harmonised technical C E a 2 a E M BR4 Safety l mv : 'moving length' 1510 mm l m : length max 3050 mm fixed hole FP and slotted holes SP in the middle of the vertical part of the board. All other positions: moving points Fixing type Fixing positions concerning loads M: fixing in intermediate position E: edge fixing C: corner fixing b max a max a 1 a 2 6 8 10 6 8 10 6 / 8 10 6/8/10 Screw 400 500 600 400 500 600 15 20 50 Nail 400 500 600 300 400 500 15 20 50 ETA-13/0019, 9, 10 and 11 Page 10 of 12

BR4 Safety 7 Performance shear strength mechanical fixings Characteristic shear strength mechanical fixings - Average values Fixing Failure load 6 mm 8 mm 10 mm Screw 1160 N 1162 N 1406 N ETA-13/0019 Nail 900 N 863 N 935 N 8 - Specifications mechanical fixings Ring-shank nail 2.7/2.9 x 32 and 2.7/2.9 x 40 mm Stainless steel in accordance with EN 10088 Material number 1.4401 or 1.4578 Torx screws 4,5 x 35 mm Stainless steel in accordance with EN 10088 Material number 1.4401 or 1.4578 Geharmoniseerde technische specificatie d d d h d 2 d h d 1 BR4 Safety d h t l for nail 32 = 31 32,5 l for nail 40 = 39 40,5 l 2 for nail 32 = 24 26 l 2 for nail 40 = 32 34 l l g d = 2.6 2.8 d 2 = 2.8 3.0 l p 4.8 l g = l 2 - l p d h = 5.8 6.3 h t = 0.8 1.0 l 2 l p l = 35-1.25 l g = 26.25 28.5 l l g d = 3.3 3.4 d 1 = 4.3 4.6 d h = 9.6-0.4 ETA-13/0019 issued 2015-11-03, 3 and 4 9 Performance Impact resistance Impactor Energy Category BR4 Safety Hard body Steel ball 0.5 kg 1 J IV ETA-13/0019 issued 3 J III, II and I 2015-11-03, 5 BR4 Safety 10 Performance dimensional stability Length Width Cumulative dimensional change [a] 0.068% 0.065% Dry heat 23 C / 50% to 23 C / 0% (mm/m) -0,284-0,239 Coefficient of thermal expansion (10-6 K -1 ) 9.4 10.1 Coefficient of moisture expansion 42% RH (mm/m) 50% to 92% RH after 4 days 0.237 0.244 [a] As a consequence the minimum joint width shall be 3 mm, preferably 5 mm. ETA-13/0019 issued 2015-11-03 Page 11 of 12

Aspects of durability and serviceability 11 Resistance to hygro-thermal cycles and Xenon Arc exposure Resistance to Hygro-thermal cycles Resistance to Xenon Arc exposure EOTA TR010 climate class S (Technical Report 010) 5000 hours artificial weathering Finish primer coating Performance Pass Not relevant (NPD) ETA-13/0019 8. The performance of the product identified above is in conformity with the set of declared performance/s. This declaration of performance is issued, in accordance with Regulation (EU) No 305/2011, under the sole responsibility of the manufacturer identified above. Signed for and on behalf of the manufacturer by: ROCKWOOL B.V. W.J.E. Dumoulin Technical Director Operations DE-NL At Roermond, The Netherlands on 28 th January 2016 DOP in accordance with Commission Delegated Regulation (EU) No 574/2014 of 21 February 2014 amending Annex III to Regulation (EU) No 305/2011 of the European Parliament and of the Council on the model to be used for drawing up a declaration of performance on construction products, http://eur-lex.europa.eu/legal-content/en/txt/?uri=celex%3a32014r0574, OJ L 159, 28.5.2014, p. 41 46 Page 12 of 12