L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

Similar documents
Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Ecologix Environmental Systems, LLC

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Precision Automatic Vacuum Control (PAVC+)

Installation and Operation Manual

Tuffy T3 Liquid Level Controls with Electric Switches

92831 TEL: (714) FAX:

Wash Down Duty Non-Contact Sensor

WHOLE HOUSE FILTER &

USER'S GUIDE TO OPERATION

No part of this manual may be reproduced in any form or by any means, without prior written permission of Darrera.

Aero Tec Models 700 & 750 (115 vac)

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

Installation, Operation & Maintenance Manual

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Installation, Operation & Maintenance Manual

Model # 158-P4. 12/12/2013 Page 1 of 11

Model # 358H-PR. 4/8/2011 Page 1 of 12

Model # 238HS-P8. 4/27/2011 Page 1 of 11

INSTALLATION PROCEDURE

Service/Warranty Information

HDI 2200 Choke Position Indicator

Pneumatic PalletPal Level Loader

HIGH SEAL ULF Live Loaded Packing System

Model # 922-S4. 12/18/2013 Page 1 of 8

Model # BARK-358-RDP

Bottom Hinged Flood Barrier Operation & Maintenance Manual

Drag Chain Conveyor Installation and Operation Manual

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

Owner s Manual & Safety Instructions

Sby SR Instruments, Inc.

Global Water Instrumentation, Inc.

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

Installation Manual. LIFETIME LIMITED WARRANTY Warranty applies to select Residential faucets only. Pressure Balance Valve TSPVR & TSPTR

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide

Model # 338S-OP. 9/30/2011 Page 1 of 13

INSTALLATION PROCEDURE

DRYWALL DOLLY 900 LB. CAPACITY

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

PC-1 Programmable Controller

OPERATOR S SAFETY MANUAL

4 rotary milling table

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

AM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide

Sho-Rate TM Models 1250 & 1255

Thermoelectric Cooler

Model: LoLander Series Truck Scale Model: LL FT Model: LL FT Installation, Set-Up and Operation Manual

Owner s Manual & Safety Instructions

FPF-P 2045 FLAT TOP CHAIN CONVEYOR

Model # 358-R48. 7/7/2011 Page 1 of 11

Loading Arm Installation, Maintenance & Safety Manual

Operating Instructions

Made in USA TRUNNION MOUNTED BALL VALVE INSTALLATION, MAINTENANCE, & REPAIR MANUAL

INSTALLATION PROCEDURE

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

Industrial flue gas probes. Instruction manual

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

Compu Dry Dehumidifying Dryer

Particulate Filters. Filter Function. Exclusive Dense Pack Element Design. Optional Components

Section 3 Fusible PVC Pipe Connections

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

OPERATION AND INSTALLATION MANUAL

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

INSTALLATION MANUAL Models 330, 331 and Model 335 Models 430, 431

MODEL SJ10. Installation Manual. SumpJet TM - Water Powered Backup System C IMPORTANT: MODEL SERIAL

Pedestrian Flood Door

Field Economy Unit Instruction Manual

Universal Tilting TV Mount 32" to 60" Installation Instructions

Monolithic Isolation Fittings

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

PEN SEAL. Pipe Penetration Seals

Media-Isolated Mag Plus Probe LPG-ISO Kit

Installation. Basic Rack Power Distribution Units AP9560 AP9561

VISE MOUNTED. Model 97359

RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

7 PIECE TUBE FLARING KIT

AM1730 Secondary Reference Platinum Resistance Thermometer User s Guide

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

SERIES G1A, G1B & G1C SLIDE GATES

POLICY AND PROCEDURE MANUAL

RJE INTERNATIONAL, INC.

NOTICE: To the prices and terms quoted, there will be added any manufacturers or sales tax payable on the transaction under any effective statute.

Owner s Manual & Safety Instructions

Zehnder Carboline Radiant Heating and Cooling Ceiling Panels. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air

AQUA UNO T UB DOOR AND T UB DOOR GLASS PANEL INSTALLATION INSTRUCTIONS

Model M120 Mini Temperature/Humidity Meter

Stainless steel rolling cabinet

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

self level laser Model Set up And Operating Instructions

INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000

SERIES G1G, G1H & G1I SLIDE GATES

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

AM1880 Standard Platinum Resistance Thermometer User s Guide

TEMPERATURE SWITCHES AND THERMOSTATS

Fisher ENVIRO-SEAL Packing System for Sliding-Stem Valves

Transcription:

L505 VISUAL LEVEL INDICATOR INSTALLATION AND OPERATIONS MANUAL Dip-Tape Visual Level Indicator

READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the L505 Dip-Tape Visual Level Indicator. It is important that all instructions are read carefully and followed sequentially. Detailed instructions are included in the Complete Installation section of this manual. Conventions Used in this Manual Certain conventions are used in this manual to convey specific types of information. General technical material, support data and safety information are presented in narrative form. The following styles are used for notes, cautions and warnings: Notes Notes contain information that augments or clarifies an operating step. Notes do not normally contain actions and often follow the procedural steps to which they refer. Cautions Cautions alert the technician to special conditions that could injure personnel, damage equipment, or reduce a component s mechanical integrity. Cautions are also used to alert the technician of unsafe practices, the need for special protective equipment, or specific materials. In this manual, a caution indicates a potentially hazardous situation which, if not avoided, may result in minor to moderate injury. Notice of Copyright and Limitations Copyright 2015 Solutions With Innovation, LLC; All rights reserved. Solutions With Innovation reserves the right to make changes to the product described in this manual at any time without notice. Solutions With Innovation makes no warranty with respect to the accuracy of the information in this manual. Warranty All Solutions With Innovation Mechanical Level and Flow Controls are warranted free of defects in materials and workmanship for one full year from the date of the original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Solutions With Innovation will repair or replace the product at no cost to the purchaser (or owner) other than transportation. Solutions With Innovation shall not be liable for misapplication, labor claims, direct or consequential damage, or expenses arising from the installation or use of the equipment. There are no other warranties expressed or implied, except special written warranties covering specific Solutions With Innovation products. Quality Assurance The Quality Assurance System in place at Solutions With Innovation guarantees the highest level of quality throughout the company. Solutions With Innovation is committed to providing full customer satisfaction; both in quality products and in quality service. Contacts Phone: 203-729-6434 Mon-Fri, 9 AM - 5 PM EST Fax: 203-729-0541 for General Inquiries Email: sales@innovativesensing.com 2 L505 DIP-TAPE VISUAL LEVEL INDICATOR

TABLE OF CONTENTS L505 VISUAL LEVEL INDICATOR Dip-Tape Indication Design 1.0 Installation 1.1 Unpacking...4 1.2 Before You Begin...4 1.2.1 Site Preparation...4 1.2.2 Equipment and Tools...4 1.3 Mounting...4 2.0 Preventative Maintenance 2.1 What To Do...5 2.1.1 Inspect Entire Unit Periodically...5 2.1.2 Keep Unit Clean...5 2.2 What To Avoid...5 3.0 Reference Information 3.1 Description...5 3.2 Theory of Operation...5 3.3 Troubleshooting...6 3.3.1 Unit Causes...6 3.4 Specifications...7 3.4.1 Physical Specifications...7 3.4.2 Functional Specifications...7 3.4.3 Dimensional Specifications...7 3.5 Model Configurator...8 3.6 Notes...9 L505 DIP-TAPE VISUAL LEVEL INDICATOR 3

1.0 COMPLETE INSTALLATION This section provides detailed procedures on properly installing the L505 Dip-Tape Visual Level Indicator. CAUTION! IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. 1.1 UNPACKING Unpack the instrument, carefully. Make sure that all components have been removed from the packing material. Inspect all components for damage. Report any concealed damage to the carrier within 24 hours of receiving. Compare the contents with the packing slip and report any discrepancies to the factory immediately. Record the sales order number and/or serial number for future reference when ordering parts. Before Proceeding to Installation, Complete the Following: Inspect all components for damage. Report any damage to the carrier within 24 hours of receiving. Record the model and serial numbers for future reference when ordering parts. Model Number Serial Number 1.2 BEFORE YOU BEGIN CAUTION! DURING THE INSTALLATION OF THE L505 DIP-TAPE VISUAL LEVEL INDICATOR, THE FLOAT AREA MUST BE KEPT FREE OF METALLIC PARTICLES THAT MIGHT BE ATTRACTED TO THE FLOAT S INTERNAL MAGNET. 1.2.1 Site Preparation Ensure that the length and mounting is sized correctly to accommodate the L505 Dip-Tape Visual Level Indicator. 1.2.2 Equipment and Tools No special equipment or tools are required to install the L505 Dip-Tape Visual Level Indicator. The Following Is Recommended: An Appropriately-Sized Wrench 1.3 MOUNTING The L505 Dip-Tape Visual Level Indicator is available in a variety of threaded mounting sizes. It is recommended that the unit is mounted vertically at the top of a tank or barrel. Installing the L505 Threaded Mount: 1 Apply either Teflon tape or an appropriate thread sealant to the mounting threads to prevent galling. 2 Engage the thread by hand to avoid unnecessary damage. 3 Using a wrench, rotate the unit clockwise until the threads are tight within the mounting. 4 Ensure that the float and stem are in a vertical orientation. 4 L505 DIP-TAPE VISUAL LEVEL INDICATOR

2.0 PREVENTATIVE MAINTENANCE Periodic inspections are necessary to maintain the proper functionality of the L505 Dip-Tape Visual Level Indicator. A systematic program of preventative maintenance should be implemented at the time of installation. If the following instructions are completed routinely, the indicator will provide continuous, reliable protection. 2.1 MAINTENANCE PROCEDURES 2.1.1 Inspect Unit Periodically Verify that there are no dents or bends in the float and stem. Should the unit become damaged, obtain a replacement immediately. 2.1.2 Keep Unit Clean Periodic cleanings of the float and stem will ensure the continual, uninterrupted movement of the mechanism. Always keep the areas around the unit clean and free of any potential interferences. Objects and debris may cause systematic interruptions and a loss in equipment functionality. 2.2 WHAT TO AVOID NEVER USE IN SYSTEMS CONTAINING IRON PARTICLES. The magnet within the float assembly can attract the particles and become jammed. 3.0 REFERENCE INFORMATION This section illustrates an overview of the L505 Dip-Tape Visual Level Indicator, as well as information on troubleshooting common problems, agency approval listings, and detailed physical, functional and performance specifications. 3.1 DESCRIPTION The L505 is a simple and economical liquid level indicator designed for quick, continuous readings in remote and mobile storage tanks. The unit requires no electricity to operate and provides an accurate visual level indication within 1 16. Available construction materials include a brass/buna-n combination and an all stainless steel option in a variety of threaded mounting sizes. Measuring lengths range from 6 to 6 (15.24 cm to 1.8 m) in either customary or metric steel tapes. 3.2 THEORY OF OPERATION The sliding steel tape magnetically interlocks with the level position of the float. Level measurement is obtained by sliding the tape from the stem tube and locating the calibration mark where the interlock is felt. The float and stem make contact with the liquid, but the tape remains separate and clean. When the indicator is not in use, it is safely sealed within the tube by a protective screw cap. L505 Brass/Buna L505 Stainless Steel L505 DIP-TAPE VISUAL LEVEL INDICATOR 5

3.3 TROUBLESHOOTING The L505 Dip-Tape Visual Level Indicator is designed and manufactured for trouble-free operation over a wide range of operating conditions. Common problems are discussed in terms of their symptoms and recommended corrective actions. 3.3.1 Unit Causes SYMPTOM PROBLEM SOLUTION THE OUTPUT IS INACCURATE. A COATING OR BUILD-UP IS PRESENT ON THE FLOAT AND/OR STEM. REMOVE THE INDICATOR FROM SERVICE. CHECK THE FLOAT AND STEM FOR A COATING OR BUILD-UP OF DEBRIS. IF A COATING OR BUILD-UP IS PRESENT, CLEAN THE STEM AND FLOAT TO REMOVE THE CONTAMINANTS. THE OUTPUT IS INACCURATE. LIQUID IS NOT ENTERING THE VESSEL. CHECK TO ENSURE THAT LIQUID IS ENTERING THE TANK OR VESSEL. A CLOSED VALVE OR CLOGGED PIPELINE MAY PREVENT MOVEMENT OF THE LIQUID IN THE VESSEL. THE OUTPUT IS INACCURATE. THE TANK LEVEL IS NOT HIGH ENOUGH TO HAVE THE FLOAT FUNCTION. CHECK THE FLOAT TO MAKE SURE IT IS BUOYANT IN THE LIQUID. THE TANK OR VESSEL MUST HAVE AN ADEQUATE LIQUID LEVEL. THE FLOAT IS NOT BUOYANT. THE FLOAT IS COLLAPSED AND/OR FILLED WITH LIQUID. CHECK THE FLOAT FOR RUPTURES, DEFORMATION, AND ANY LIQUID TRAPPED INSIDE THE ASSEMBLY. IF THE FLOAT IS FILLED WITH LIQUID OR HAS COLLAPSED, IT MUST BE REPLACED. DO NOT ATTEMPT TO REPAIR THE FLOAT. If you are still in doubt about the condition or performance of your indicator, consult the factory for further instructions. 6 L505 DIP-TAPE VISUAL LEVEL INDICATOR

3.4 SPECIFICATIONS 3.4.1 Physical Specifications FLOAT MATERIAL STEM MATERIAL TEMPERATURE PRESSURE FLOAT SG* SUGGESTED MIN. SG* Buna-N Brass -40 to +180 F (-40 to +82 C) 316 Stainless Steel 316 Stainless Steel -40 to +300 F (-40 to +149 C) 3.4.2 Functional Specifications 150 PSIG (10.3 bar) 750 PSIG (51.7 bar) 0.57 0.75 0.59 0.75 *SG refers to the liquid specific gravity. MEASUREMENT PRINCIPLE Magnetic Interlock MEASUREMENT VARIABLE Visual Level Indication with Graduated Steel Measuring Tape INDICATION LENGTH 6 to 6 (15.24 cm to 1.8 m) TAPE MEASURE OPTIONS Customary (Inches, Feet) Metric (Centimeters, Meter) 3.4.3 Dimensional Specifications STEEL TAPE PROTECTIVE SCREW CAP NPT MOUNT LO MAX. LENGTH 120 Ø ½ OUTER DIAMETER INDICATING LENGTH FLOAT RETAINING RING L505 DIP-TAPE VISUAL LEVEL INDICATOR 7

3.5 MODEL CONFIGURATOR TECHNOLOGY SERIES CONFIG. MOUNT STEM FLOAT TAPE STYLE L Liquid Level Sensor 505 Dip-Tape Visual Indicator - Standard 08 1 ½ NPT 01 Brass 08 316 S.S. 01 Customary C Custom 09 2 NPT 08 316 S.S. 20 Buna-N 02 Metric 10 3 NPT L 5 0 5-0 8 0 8-0 8 0 1 8 L505 DIP-TAPE VISUAL LEVEL INDICATOR

3.6 NOTES L505 DIP-TAPE VISUAL LEVEL INDICATOR 9

ASSURED QUALITY & SERVICE COST LESS Service Policy Owners of Solutions With Innovation products may request a return of the product, or any part of the product for complete rebuilding or replacement. Units will be rebuilt or replaced promptly. Products returned under the SWI Service Policy must be returned by prepaid transportation. Solutions With Innovation will repair or replace the product at no cost to the purchaser (or owner) other than transportation if: 1 Returned within the warranty period; and 2 Factory Inspection finds the cause of the claim to be covered under the warranty. If the problem is due to circumstances beyond Solutions With Innovation s liability, or is NOT covered by the warranty, there will be charges for labor in addition to the parts required to rebuild or replace the equipment. In rare cases, it may be expedient to ship replacement parts; or in extreme cases, an entire product before the damaged product is returned. If a quick replacement service is necessary, notify the manufacturer of the damaged product s model and serial number. In such cases, credit for the returned materials will be determined on the applicability of the warranty. Return Material Procedure In order to efficiently process any returned materials, it is essential that a Return Material Authorization (RMA) number be obtained from the manufacturer prior to an item s return. RMA s can be issued through local representatives, or by contacting the factory directly. Please supply the following information: 1 The Company s Name 2 Description of the Material 3 Product Serial Number 4 Reason for Return 5 Product s Application Used units must be properly cleaned in accordance with OSHA standards before it is returned to the manufacturer. A Material Safety Data Sheet (MSDS) must accompany units or materials that were used in any type of media. All return shipments to the factory must be by done via prepaid transportation. All product replacements will be shipped F.O.B. manufacturer. No claims for misapplication, labor, direct or consequential damage will be allowed. BULLETIN: IS-9199.2 EFFECTIVE: 1/15