SCC Inc. QAx Series. Technical Instructions. Document No. SEN-1000 March 15, Temperature Sensors. Description. Features.

Similar documents
TNF CAPILLARY THERMOMETERS

SURFACE TEMPERATURE SENSORS

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Resistance Temperature Detectors (RTD)

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

INDUSTRIAL TEMPERATURE SENSORS

TNF CAPILLARY THERMOMETERS

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

SECTION 2: PROBES. Page 2-1

Thermal-Tab and Thermal-Ribbon Sensors

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

TRR. Gas or Vapour Remote Reading Thermometer

Flow Rate Measurement In Emissions Monitoring

Micro Motion Technical Overview and Specification Summary

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

NRF CAPACITANCE LEVEL TRANSMITTER

VERIS Accelabar. Superior Flow Measurement Accuracy

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Temperature Measurement Solutions. Dial Indicating Electronic Industrial RTDs Thermowells Accessories

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Thermocouple Heads. MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model No.) B-9 76 (3) Model Price Material Type Number Each 48 (1 7 8)

4 RESISTANCE THERMOMETRY

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Thermocouple for Flue Gas Temperature Measurements,

MGO INSULATED THERMOCOUPLES INDEX

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Omnigrad T TST310. Technical Information. RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring

Thermistor vs RTD Temperature Accuracy

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

ISO 9001:2008 certified

General Information, Industrial Thermocouple Section

Vortex EX DELTA lowmeter Technical Specifications

FLOWRATE MEASURE PROBE DEBIX

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

Manufacturing Range. Production and Know-how Center RÜEGER SA, Crissier (Switzerland)

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Temperature Sensors. The Watlow Educational Series Book Four

Flow Through Toroidal Conductivity Sensor

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice

7700 TEST KIT OPERATIONS MANUAL

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

Thermocouples and Accessories Product Catalog

Industrial Thermocouples

ATI-ES Code Compliance Research Report

Target Inline Flowmeter

RoverBot Assembly. The following pages show assembly plans for the RoverBot using the Consumer MindStorms or School Team Challenge Lego kit.

Signet Differential DryLoc ph/orp Electrodes

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Metal Transitions HIGH TEMPERATURE

an ISO9001 company TECHNICAL INFORMATION FOR TGS2600 Technical Information for Air Quality Control Sensors

INDUSTRIAL THERMOMETERS

EC91346S Conductivity Cell Instruction Manual

ATI Evaluation Service A Division of Architectural Testing Certification Services

Accessories. Accessories. Parker Autoclave Engineers offers a complete selection of accessories to complete your system requirements.

Resource Guide. Section 4: Ni-Resist

Model PM-616 Two-Color Pyrometer Operator s Manual Revision 1.2

Selection Guide for Conductivity Cells and Compensators 4973 Should be quoted whenever possible for constants 0.01 to 10 cm -1.

All-Welded System(AWS) Type M93X.D1

Model Instruction Manual

Humidity/temperature measuring instrument

Rosemount 405 Compact Orifice Primary Element

Omnigrad M TR47, TR48

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Code Compliance Research Report CCRR-0185

Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter

Accessories. Accessories. Autoclave Engineers offers a complete selection of accessories to complete your system requirements.

Temperature Calibration

Small-Scale Resistance Welding for Medical and Industrial Applications

Measurement Methods and Calculations to Determine Internal Deposit Stress. Frank H. Leaman Specialty Testing & Development, Inc.

Gilflo flowmeters. for steam, liquids and gases

Diaphragm seal with flange connection With internal diaphragm Model

diaphragm valves DV1 Series 2-Way Diaphragm Valves Typical Applications Analytical Instrumentation Petrochemical Pharmaceutical Chemical

Bonded Neo Magnetization Guide

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

D1 Series Multi-hole Cage Guided Control Valves

For Safe and Delicious Water

TEMPERATURE SWITCHES AND THERMOSTATS

THERMOCOUPLE AND EXTENSION GRADE BARE WIRE

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS

Platinum Temperature Sensors

Cash Valve. Type C-776. ASME Section VIII Air/Gas and Cryogenic, UV National Board Certified Safety Valve. Flow Control

Optica. GE Sensing. The Next Generation Humidity Reference Standard. Optica Measures

Online data sheet SMC209 C CEMS SOLUTIONS

For highest levels of purity

Optimizing Strain Gage Excitation Levels

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

ATI Evaluation Service A Division of Architectural Testing Certification Services

Temperature Measurement and Control

Transcription:

SCC Inc. QAx Series QAC QAE QAM 544 Temperature Sensors Technical Instructions March 15, 2018 Description Features Application QAx and 544 temperature sensors are resistance temperature detectors (RTDs). RTDs work on the principal that the resistance of the sensing element changes as a direct function of the temperature. Accurate and reliable indication of temperature Easy installation requiring no special tools Suitable for media -58 F to 900 F depending on model QAx and 544 sensors are used to measure water, steam, air, exhaust, or FGR temperature. A variety of sensors are available in order to meet the needs of different applications. QAx and 544 temperature sensors are capable of reliably measuring temperatures as low as -58 F or as high as 900 F. SCC Inc.

Technical Instructions QAx Series Specifications QAE2012.001 Sensing element Platinum, 1000 Ohm, 2-wire Operating temperature -4 to 374 F [-20 to 190 C] Thermowell 2.5 insertion, stainless steel Primary use Water / ambient air temperature sensor for LMV5x / RWF40 / RWF50 / RWF55 QAE2020.001 Sensing element Platinum, 100 Ohm, 3-wire Operating temperature -4 to 374 F [-20 to 190 C] Thermowell 2.5 insertion, stainless steel Primary use Water temperature sensor for LMV5x / RWF10 / RWF40 / RWF50 / RWF55 QAE2020.005 Sensing element Nickel, 1000 Ohm, 2-wire Characteristic LG (see Appendix A, page 11) Operating temperature -13 to 266 F [-25 to 130 C] Thermowell 2.5 insertion, stainless steel Primary use Water / ambient air temperature sensor for LMV5x / RWF40 / RWF55 Page 2 SCC Inc.

QAx Series Technical Instructions Specifications (continued) QAE2020.010 Sensing element Nickel, 1000 Ohm, 2-wire Characteristic LG (see Appendix A, page 11) Operating temperature -13 to 266 F [-25 to 130 C] Thermowell 4 insertion, stainless steel Primary use Water / ambient air temperature sensor for LMV5x / RWF40 / RWF55 QAE2020.015 Sensing element Nickel, 1000 Ohm, 2-wire Characteristic LG (see Appendix A, page 11) Operating temperature -13 to 266 F [-25 to 130 C] Thermowell 6 insertion, stainless steel Primary use Water / ambient air temperature sensor for LMV5x / RWF40 / RWF55 544-577-25 Sensing element Platinum, 1000 Ohm, 2-wire Operating temperature -40 to 240 F [-40 to 116 C] Thermowell 2.5 insertion, stainless steel Primary use Water / ambient air temperature sensor for LMV5x / RWF40 / RWF55 SCC Inc. Page 3

Technical Instructions QAx Series Specifications (continued) 544-577-40 Sensing element Platinum, 1000 Ohm, 2-wire Operating temperature -40 to 240 F [-40 to 116 C] Thermowell 4 insertion, stainless steel Primary use Water / ambient air temperature sensor for LMV5x / RWF40 / RWF55 544-577-60 Sensing element Platinum, 1000 Ohm, 2-wire Operating temperature -40 to 240 F [-40 to 116 C] Thermowell 6 insertion, stainless steel Primary use Water / ambient air temperature sensor for LMV5x / RWF40 / RWF55 QAE2012.903 Sensing element Platinum, 100 Ohm, 3-wire Operating temperature -50 to 900 F [-46 to 482 C] Thermowell 4 insertion, stainless steel Weather head Aluminum, 3/4 NPT Primary use Water / steam temperature sensor for LMV5x / RWF10 / RWF40 / RWF50 / RWF55 Accessories QAE-AC-903P: 0-900 to 4-20 ma transmitter Page 4 SCC Inc.

QAx Series Technical Instructions Specifications (continued) QAE2012.9002 Sensing element Platinum, 1000 Ohm, 2-wire Operating temperature -50 to 900 F [-46 to 482 C] Thermowell 4 insertion, stainless steel Weather head Aluminum, 3/4 NPT Primary use Water / steam temperature sensor for LMV5x / RWF10 / RWF40 / RWF50 / RWF55 QAC22 Sensing element Nickel, 1000 Ohm, 2-wire Characteristic LG (see Appendix A, page 11) Operating temperature -58 to 158 F [-50 to 70 C] Process connection None Thermowell None Weather head Integral, hole for M16 connection Primary use Ambient air temperature sensor for LMV52 / RWF40 / RWF55 QAM-P206 Sensing element Platinum, 1000 Ohm, 2-wire Operating temperature -50 to 900 F [-46 to 482 C] Probe 1/4 diameter, 6 long, stainless steel Process connection 1/2 NPT Thermowell None Weather head Aluminum, 3/4 NPT Primary use Stack or FGR temperature sensor for LMV52 SCC Inc. Page 5

Technical Instructions QAx Series Specifications (continued) QAM-P210 Sensing element Platinum, 1000 Ohm, 2-wire Operating temperature -50 to 900 F [-46 to 482 C] Probe 1/4 diameter, 10 long, stainless steel Process connection 1/2 NPT Thermowell None Weather head Aluminum, 3/4 NPT Primary use Stack temperature sensor for LMV52 Page 6 SCC Inc.

QAx Series Technical Instructions Wiring QAE2012.001, QAE2020.005, QAE2020.010, QAE2020.015, 544-577-25, 544-577-40, 544-577-60 QAE2020.001 white yellow yellow black or gray black or gray QAE2012.903 QAE2012.9002, QAM-P206, QAM-P210 white red red white QAC22 red G1+ M1 I1 RWF40 water / steam 3 4 5 RWF10 water / steam 11 12 14 RWF55 water / steam 11 12 13 RWF50 water / steam X60.1 X60.2 X60.4 LMV5x water / steam G1+ M1 RWF40 water / steam B9 M9 RWF40 ambient air 11 14 RWF55 water / steam 31 32 RWF55 ambient air 11 13 RWF50 water / steam X60.3 X60.4 LMV5x water / steam X86.1 X86.2 LMV52 exhaust X87.1 X87.2 LMV52 ambient air Note: There is no polarity when wiring a 2-wire RTD. SCC Inc. Page 7

Technical Instructions QAx Series Dimensions Dimensions in inches; millimeters in brackets QAE2012.001, QAE2020.001, QAE2020.005, 544-577-25 QAE2020.010, 544-577-40 Page 8 SCC Inc.

QAx Series Technical Instructions Dimensions (continued) Dimensions in inches; millimeters in brackets QAE2020.015, 544-577-60 QAE2012.903, QAE2012.9002 SCC Inc. Page 9

Technical Instructions QAx Series Dimensions (continued) Dimensions in inches; millimeters in brackets QAC22 QAM-P206 Page 10 SCC Inc.

QAx Series Technical Instructions Dimensions (continued) QAM-P210 SCC Inc. Page 11

Technical Instructions Appendix A QAx Series Resistance vs. Temperature Charts Pt100, 385 characteristic (QAE2012.903, QAE2020.001) Pt1000, 385 characteristic (QAE2012.001, 544-577-25, 544-577-40, 544-577-60, QAE2012.9002, QAM-P206, QAM-P210) Page 12 SCC Inc.

QAx Series Appendix A (continued) Technical Instructions Resistance vs. Temperature Charts Ni1000, LG characteristic (QAE2020.005, QAE2020.010, QAE2020.015, QAC22) SCC Inc. Page 13

Technical Instructions Appendix A (continued) QAx Series Accuracy Pt100 and Pt1000 Sensors (QAE2012.001, QAE2020.001, 544-577-25, 544-577-40, 544-577-60, QAE2012.903, QAE2012.9002, QAM-P206, QAM-P210) Accuracy = ± [0.54 + (0.005 x T - 32 )] T = Temperature in degrees Fahrenheit Ni1000 Sensors (QAE2020.005, QAE2020.010, QAE2020.015, QAC22) For T < 32: Accuracy = ± [0.72 + (0.028 x T - 32 )] For T > 32: Accuracy = ± [0.72 + (0.007 x T - 32 )] T = Temperature in degrees Fahrenheit Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2018 SCC Inc. SCC Inc. Your feedback is important to us. If you have 1250 Lunt Avenue comments about this document, please send them Country of Origin: US Elk Grove Village, IL 60007 to techsupport@scccombustion.com Page 14 U.S.A.