FIRESTOPPING Products for Life Safety and Code Compliance

Similar documents
Firestop Products for Construction Joints Applications

Fire Protection Product Applications by Contractor Trades Through Penetrations & Joints

FIRESTOP SUBMITTAL PACKAGE

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

DECEMBER Phone: Fax:

Protecting Penetrations in Fire Rated Construction

FIRESTOP SUBMITTAL PACKAGE

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

Innovative products and solutions for life safety and code compliance.

Cavity ShAftwall System

FIRE-HALT SEALANT/SETTING COMPOUND

3M CS-195+ Composite Sheet Product Description

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

Pre & Post Occupancy Fire Barrier Management

Design & Construction Standards, Revised January

Common Firestop Code Violations

FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

Fire Barrier Duct Wrap 615+

3M Fire Protection Products. Confidence. Even Under Fire. Principal Products Ltd I Ph: I

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)

Complete Mechanical Solution: NO sealant or putty required. Can be extended for thicker walls, and ganged for increased capacity.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

SECTION HVAC INSULATION

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

PASSIVE FIRE PROTECTION PRODUCTS

An Overview of Firestopping and Fireblocking: What s the Difference?

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

FireMaster FastWrap XL

Building Systems and Design Elements included in SliDeRulE

Joint Systems. System No. FF-D-0044

11/2 HOUR UL CLASSIFIED CURTAIN TYPE (D)IBD2, (D)IBD2SS AND IBDT FIRE DAMPERS

Pyroscat Duct Wrap XL

Unique Fire Stop Online Certification Test

Fire Protection Products

I-STUD Shaftwall System

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

FC /2 Hour Curtain Fire Dampers

FireMaster FastWrap XL

Firestopping Submittal Package

A Pocket Guide For Inspectors Firestopping Inspection Manual Penetr Perimeter Fire Barrier Systems and Fire Rated Duct stems.

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

FIRESTOP SYSTEMS NOTES: Tony Crimi, P.Eng. A.C. Consulting Solutions Inc. Canadian Code Requirements

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

HILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems

HILTI CP 643N Firestop collar

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual

SECTION SOUND ISOLATION

SECTION GYPSUM BOARD

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

HILTI CP 606 Flexible Firestop Sealant

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

WIRING METHODS CHAPTER 38

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

A. Source Limitations: Obtain each type of building insulation through one source.

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

Thermasheath-XP. Insulation for Exposed Use

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

Product Guide Specification

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

138 H-STUD AREA SEPARATION WALL SYSTEM

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

UL Catalogue I en. Innovative Fire Protection Systems

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HILTI CP 657 Firestop Brick

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

University of Delaware

This page was. intentionally. left blank

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

SECTION GYPSUM BOARD ASSEMBLIES

Transcription:

07 84 00/SPE BuyLine 9360 FIRESTOPPING Products for Life Safety and Code Compliance

PRODUCT SELECTOR SPECIFIED TECHNOLOGIES INC. Specified Technologies, Inc. (STI) is an industry leader solely committed to the development of innovative, reliable firestopping solutions that help stop the spread of fire, smoke and toxic fumes. For over 25 years, our management team has worked hand in hand with the construction industry to create innovative firestop solutions for all types of new construction and retrofit applications. We offer the broadest range of UL Classified Systems more than any other manufacturer. We keep material requirements to a minimum and we design systems with the installer in mind. The result is less labor and significantly lower installed costs. 2007 Specified Technologies, Inc. FIRESTOP SEALANTS Triple S Intumescent Sealant Premium grade intumescent firestop sealant featuring STI s patented two-stage intumescent technology. Triple S can be used in most common through-penetrations as well as a variety of membrane penetrations and construction joints. A LCI Intumescent Sealant Standard grade intumescent firestop sealant engineered to economically address many common through-penetration applications in light commercial construction. LC Endothermic Sealant High quality, non-halogenated firestopping sealant designed for non-combustible penetrants in through-penetrations and construction joints. PENSIL Silicone Products Premium silicone-based firestop sealant for use with construction joints as well as a variety of through-penetration firestop applications. PEN300 is a highly elastomeric product in construction joint applications that allows ± 50% movement. RESIDENTIAL CAULK WF300 Firestop Caulk Intumescent firestop caulk designed for sealing through-penetrations and gaps in fire resistance-rated wood frame construction. SmokeBlock E-136 Caulk Meets the requirement of ASTM E136 for use in non-rated applications for fireblocking and draftstopping. FIRESTOP MORTAR SSM Firestop Mortar Lightweight, cementitious, compound suitable for openings of all sizes in fire-rated construction. B 1.800.992.1180

07 84 00/SPE BuyLine 9360 WRAP STRIPS & RESTRAINING COLLARS SSW Wrap Strips Intumescent, flexible wrap strips for through-penetrations. WSC Restraining Collars Preformed metal restraining collars for use with SSW Wrap Strips in plastic pipe applications. FIRESTOP COLLARS Firestop Collars Ready-to-use firestop devices designed to collapse plastic pipe penetrations when exposed to fire conditions. C Range-Taking Collars Factory-manufactured device designed to seal plastic pipes penetrating fire resistance rated walls and floors. SpecSeal RTC Collars are designed to allow a single collar to fit 3 and 4 trade size pipes (89 and 114 mm) and corresponding 3 and 4 couplings (102 and 127 mm). FIRESTOP ANGLE PATHWAYS F FyreFlange Duct Angle Duct support and firestopping in one product. EZ-Path Fire Rated Pathways Easy installation and cable changes without the need to firestop. Used in a variety of cabling applications where re-entry is frequently needed and allows easy retrofits for existing cables. FIRESTOP PILLOWS SSB Intumescent Firestop Pillows Intumescent firestop pillows expand in all directions for a tough, tight seal and easy retrofit for hard-to-fill, multiple penetrants, and large G openings. FIRESTOP SPRAYS & JOINT SEALANT AS Elastomeric Spray Water-based, spray applied coating for joints and certain through-penetrations in fire-rated walls or floors. D COMPOSITE SHEET Composite Sheet Lightweight, firestop panels effectively seal medium to large openings with a variety of penetrants in fire-rated floors and walls. Fast Tack Firestop Spray Quick dry firestop spray for use in curtainwall/ edge of slab, and general construction joints that are subject to movement. Cable Spray Latex-based cable spray for electrical, data or communication cables (racked or in cable trays). FIRESTOP PUTTY SSP Putty Two-stage intumescent, non-hardening putty for cable and pipe penetrations. Ideal in small to medium sized applications that will require re-entry. E ES Elastomeric Sealant Non-halogenated latex-based sealant designed to provide passive smoke and fire protection in construction joint applications. PUTTY PADS H SSP Putty Pads Two-stage intumescent, non-hardening putty pads are sized to provide protection for electrical outlet boxes. SMOKE & ACOUSTICAL SPRAY & SEALANT Smoke N Sound Acoustical Spray Spray grade product for sealing openings in nonrated smoke barriers and partitions. FIRESTOP SLEEVES Ready Sleeve Everything needed to install a firestopped sleeve in new openings including sleeve, mounting hardware and all firestopping materials. Smoke N Sound Acoustical Sealant High quality acrylic latex sealant designed for sealing through-penetrations and membrane penetrations in non-rated construction. Ready Split Sleeve Everything needed to install a firestopped sleeve around existing cables. The ONLY UL Classified firestop sleeve for use in oversize openings. JOINT PROFILE SpeedFlex Joint Profile A quick, economical alternative to using strips of mineral wool forming material in the joint area between the fire-rated wall assembly and the bottom of a steel deck or concrete floor. ELECTRICAL BOX INSERTS Powershield Electrical Box Inserts Intumescent firestop electrical box insert pads install inside electrical boxes for applications where external pads cannot be used.

Building Codes STI products meet the requirements of the following building code bodies: International Building Code Southern Building Code Congress International Chapter 7 International Code Council Building Officials and Code Administrators, International Chapter 7 International Conference of Building Officials (ICBO) Chapter 7 Council of American Building Officials; Coordinating Agency between ICBO, SBCCI, and BOCA National Codes NEC National Electric Code; Section 300-21 NFPA 101 The National Fire Protection Association Life Safety Code; Chapter 6, Appendix A-6 NFPA 70 The National Fire Protection Association, National Electric Code Chapters 3, 7, and 8. Test Requirements ASTM E814 Test method for fire tests of through-penetration firestops UL1479 Fire tests of through-penetration firestops ASTM E119 Test methods of building construction and materials UL263 Standard fire test of building construction and materials ASTM E84 Test method for surface burning characteristics of building materials ASTM E2307 Test method for perimeter joints UL723 UL standard for surface burning characteristics of building materials ASTM E1966 Test method for fire resistive joint systems UL2079 Tests for fire resistance of building joint systems ASTM E90 Standard test method for laboratory measurement of airborne sound transmission loss of building partitions Common Firestop Systems SYSTEM NUMBER DESCRIPTION ASSEMBLY PRODUCT Bare Metallic Pipes & Tubing CAJ1080 Max 30 steel or Iron pipe, max 6 copper pipe or tube Concrete floor/wall SSS Sealant CAJ1240 Max 6 steel conduit or max 4" EMT. 2-1/2" concrete Concrete floor/wall SSS Sealant Optional sleeve. 1/4" thickness sealant. CAJ1354 Multiple max 2 steel, iron, or copper pipe/tube, steel Concrete floor/wall LCI Sealant conduit, EMT, or flexible steel conduit. Caulk & backing. CBJ1058 Max 12 steel or iron pipe, max 4 copper pipe, max Concrete floor/wall PEN300 6 conduit, max 4 EMT. W Rating (class 1). FC1053 Max 4 steel, iron or copper pipe, copper tube, max 4 Floor/Ceiling WF300 steel conduit, EMT. Optional chase wall. Caulk only. WL1049 Max 24 steel or iron pipe, max 6 copper pipe Gypsum board wall SSS Sealant or tubing. Caulk only. WL1062 Max 12 steel or iron pipe, 6 copper pipe/tube, 6 Gypsum board wall PEN300 conduit, 4 EMT, or 1 flexible conduit. Caulk only. WL1222 Max 6 steel conduit, max 4" EMT or flexible Gypsum board wall LCI Sealant steel conduit. Caulk only. Insulated Metallic Pipes & Tubing CAJ5010 Max 2 steel, iron or copper pipe or copper Concrete floor/wall PEN300 tube with 1 thick fiberglass or mineral fiber. W Rating (class 1) when PVC jacket is used. CAJ5079 Max 4 steel, iron or copper pipe or tubing with Concrete floor/wall SSS Sealant 3/4" AB/PVC. CAJ5087 Max. 24 steel or iron pipe, max 6 copper pipe Concrete floor/wall SSS Sealant or tubing with 2 fiberglass. Optional sleeve. FC5043 Max 4 steel, iron or copper pipe tubing with Wood floor/ceiling LCI Sealant 1-1/2" fiberglass or 1" AB/PVC. Optional chase wall. Steel plate to to connect discontinuous lumber plates. Caulk only. WJ5005 Max 12 steel or iron pipe, max 4 copper pipe Concrete/Masonry wall SSS Sealant or tubing with 2 thick fiberglass. Caulk only. WJ5012 Max. 4" steel, iron or copper pipe or tubing with Concrete/Masonry wall SSS Sealant 3/4" to 1" AB/PVC. Caulk only. Bottom install. WL5014 Max 12 steel or iron pipe, max 4" copper pipe Gypsum board wall SSS Sealant or tubing with 2" fiberglass. Caulk only. WJ5054 Max 6 steel or iron pipe, 4 copper pipe/tube with Concrete floor/wall LCI Sealant max 2 thick fiberglass or mineral fiber. Caulk only. WJ5055 Max 4 steel or iron pipe, 2 copper pipe/tube with Concrete floor/wall LCI Sealant max 3/4 AB/PVC. Caulk only. WL5054 Max 4 steel, iron, or copper pipe or copper tube Gypsum wall SSS Sealant with 3/4 or 1 thick AB/PVC. Caulk only. WL5121 Max 6 steel or iron pipe, 4 copper pipe/tube with Gypsum wall LCI Sealant max 2 thick fiberglass or mineral fiber. Caulk only. WL5122 Max 4 steel or iron pippe, 2 copper pipe/tube with Gypsum wall LCI Sealant max 3/4 AB/PVC. Caulk only. Non-metallic Pipes & Tubing CAJ2282 Max 4 PVC, CPVC or ABS. Optional sleeve. Concrete floor/wall BLU Wrap Strip Tuck-in method. CAJ2290 Max 2 PVC, CPVC (DWV or closed), RNC, ENT, or Concrete floor/wall LCI Sealant OFR. Caulk only. Optional steel sleeve. CAJ2297 Max 6 PVC CPVC or ABS. Concrete floor/wall RED Wrap Strip, BLU Wrap Strip,BLU2 Wrap Strip CAJ2574 Max 4 PVC, CPVC pipe (DWV or closed), RNC, or Concrete floor/wall SSW Precut Strips` ENT. Wrap Strip tuck-in with precut strips. FA2048 Max 4 PVC, CPVC, ABS or FRPP. Steel plate. Concrete floor BLU Wrap Strip FA2077 Max 4 PVC, CPVC, ABS, RNC, Max 3 FRPP. Optional Concrete floor BLU Wrap Strip sleeve. Tuck-in method. FC2014 Chase wall. Max 2 PVC or CPVC pipe (DWV or Floor/Ceiling WF300 Caulk closed). Caulk only. FC2032 Max. 2 PVC, CPVC, 1-1/2 ABS, 1 PB, PEX or Wood floor/ceiling SSS Sealant, LCI Sealant PEX-AL-PEX. Optional chase wall. Caulk only. FC2044 Chase wall optional. Max 2 PVC, CPVC or ABS Floor/Ceiling RED Wrap Strip (DWV closed) or RNC. Wrap strip tuck-in. FC2158 Max 4 PVC, CPVC or ABS. Optional branch Wood floor/ceiling RED Wrap Strip BLU piping. Optional chase wall. Wrap Strip, SSC Collar, LCC Collar WL2100 Max 1 PB, PEX, max 1-1/2 ABS, max 2 PVC Gypsum board wall SSS Sealant or CPVC. Caulk only. WL2241 Max 2 PVC or CPVC, max 1-1/2" ABS, max Gypsum board wall LCI Sealant 1 PEX. Caulk only. WL2243 Super System. Max 6 PVC CPVC or ABS pipe (DWV Gypsum wall BLU Wrap Strip or closed) or RNC. Wrap strip collar or factory collar Visit us online for over 800 UL Classified Solutions RED Wrap Strip SSC Collar

Common Firestop Systems (continued) SYSTEM NUMBER DESCRIPTION ASSEMBLY PRODUCT Multiple or Mixed Mechanical/Electrical CAJ8022 Multiple 4 steel, iron or copper pipes with or Concrete floor/wall PEN300 without pipe insulation or steel conduits/emt. W Rating (class 1). CAJ8083 Multiple max 4 steel, iron or copper with optional Concrete floor/wall LCI Sealant max 2 fiberglass or 3/4 or 1 AB/PVC or 4 steel conduit/emt. Optional thermostat wires. CAJ8093 Max 12 steel or iron Pipe, max 6 copper pipe or tube, Concrete floor/ Wall Pillows 2" fiberglass, 1" AB/PVC, 3" cellular glass or calcium silicate, max 2 PVC or CPVC, max 18 diameter duct CAJ8179 Multiple AC Line Sets with 3/4 pipes, 1/2 AB/PVC, Concrete floor/wall LCI Sealant thermostat wire and optional 1-1/4 PVC line. Optional SSS Sealant sleeve. Caulk & backing. CAJ8181 Multiple metal pipes or conduits, cables, cable tray, Concrete floor/wall Composite Sheet busway, and EZ-Path. 24 sq. foot opening. FC8021 Multiple A/C Line Sets. Optional chase wall. Caulk only. Wood floor/ceiling LCI Sealant assemblies FC8036 Optional chase wall. AC line set with 3/4 metal pipe, Concrete floor/wall WF300 1/2 AB/PVC line, and thermostat wire. Caulk only. WJ8040 Multiple metal pipes or conduits(bare or insulated), Concrete floor/wall Composite sheet plastic pipe, cables, cable tray, busway, and EZ-Path. 24 sq. foot opening. WL8011 AC Line set with 1 metal pipe, 3/4 AB/PVC & Gypsum wall SSS Sealant thermostat wire. Caulk only. WL8025 AC Line set with 1 metal pipe, 3/4 AB/PVC & Gypsum wall LCI Sealant thermostat wire. Caulk only. Air Duct CAJ7023 Max 6 steel duct. Concrete floor SSS Sealant CAJ7027 Max 24 by 12 steel duct. Concrete floor SSS Sealant CAJ7040 Max 12 diam steel duct. Optional metallic sleeve. Concrete floor/wall LCI Sealant CAJ7041 Max 24 x 12 steel duct. Concrete floor/wall LCI Sealant FC7014 Max 10 steel duct. Caulk only. Wood floor/ceiling LCI Sealant assemblies FC7034 Chase wall. Max 4 round steel duct. Caulk only. Floor/Ceiling WF300 WJ7005 Max 24 steel duct. Caulk only. Concrete/Masonry wall SSS Sealant WJ7007 Max 100 by 100 steel duct. Caulk only. Concrete/Masonry wall SSS Sealant WJ7092 Max 92 x 96 steel duct. Optional max 2 fiberglass Floor/Ceiling FyreFlange TM insulation. FyreFlange. WL7025 Max 100 by 100 steel duct. Caulk only. Gypsum board wall SSS Sealant WL7026 Max 24" steel duct. Caulk only. Gypsum board wall SSS Sealant WL7060 Max 24 x 30 steel duct. Caulk only. Steel retaining Gypsum board wall LCI Sealant angles. WL7061 Max 8 round steel duct. Caulk only. Gypsum board wall LCI Sealant WL7164 Max 92 x 96 steel duct. Optional max 2 fiberglass Gypsum board wall FyreFlange TM insulation. FyreFlange. Blank Openings CAJ0094 Max 4 opening. Metallic or nonmetallic sleeve. Concrete floor/wall SSS Sealant, LCI Sealant CAJ0113 Max 900 sq. in. opening. Concrete floor/wall Composite Sheet Cables CAJ3023 Electrical, telephone or data cables (40% Fill). W Concrete floor/wall PEN300 Rating (class1). Culk & backing material. 2, 3 Hr. CAJ3154 Electrical, telephone, or data cables. Armored Concrete floor/wall SSS Sealant, Putty/Putty cables or metal clad cables. 45% Fill. 2-1/2" Pads concrete. Metallic or nonmetallic sleeve. CAJ3177 Electrical, telephone or data cables (34% Fill). Concrete floor/wall LCI Sealant Optional steel sleeve. 2-1/2 concrete. Caulk & backing material. FA3015 EZ-PATH 33 One to Seven Device Modules. Concrete floor EZ-PATH 33 Electrical, telecom or data cables.(max 100% visual fill). FA3021 Telephone or data cables (max 100% visual fill). Concrete floor/wall EZ-PATH 33 EZ-Path Kick-In Plate. FA3037 EZ-Path 44 sixteen device modules. Floor grid system. Concrete floor EZ-PATH 44 Electrical, telecom or data cable.(max 100% visual fill). FC3010 Electrical, telephone, or data cables, armormed Floor/Ceiling WF300 cables or metal clad cables (45% fill). Optional chase wall. Caulk only. FC3057 Electrical, telepone or data cables. Armored cables or Wood floor/ceiling LCI Sealant metal clad cables. 54% Fill. Optional chase wall. assemblies Caulk only. WJ3158 EZ-Path 44 One to five device modules. Electrical, Concrete/Masonry wall EZ-PATH 44 telecom or data cable. (max 100% visual fill). WL3076 Electrical, telephone or data cables, armored cables Gypsum wall SSS Sealant or metal calad cables (4-1/2 bundle). Caulk only. 07 84 00/SPE BuyLine 9360 Regional Approvals New York City MEA (Consult individual product data sheets which are available online at or by contacting customer service - 800.992.1180) State of California Fire Marshal #4485-1332:100 City of Los Angeles #RR25125 Birmingham, AL - 11/3/1993 Palm Beach County, FL - 01/25/1993 State of Wisconsin #920078-G In areas where local codes dictate, contact your STI representative for assistance. Industry Associations AFSCC - Alliance for Fire and Smoke Containment and Control ASHE - American Society for Healthcare Engineering BICSI - Building Industry Service International CSI - Construction Specifications Institute IFC - International Firestop Council NAED - National Association of Electrical Distributors NEMRA - National Electrical Manufacturer s Representatives Association NIAC - National Insulation and Abatement Contractors STAFDA - Specialty Tool and Fastener Distributor Association NIA - National Insulation Association Visit us online for over 800 UL Classified Solutions

Common Firestop Systems (continued) SYSTEM NUMBER DESCRIPTION ASSEMBLY PRODUCT Cables (continued) WL3169 Electrical, telephone or data cables, armored cables Gypsum wall LCI Sealant or metal calad cables (4-1/2 bundle). Caulk only. WL3210 Electrical, telephone or data cables. Armored cable or Gypsum board wall SSS Sealant, LCI metal clad cables. 48% Fill. Extended steel sleeve. Sealant, Putty/Putty Pads WL3218 EZ-PATH 33 One to Seven Device Module. Electrical, Gypsum board wall EZ-PATH 33 telecom or data cable. (max 100% visual fill). Cable Tray CAJ4029 Multiple 18" by 5" steel or aluminum cable trays. Concrete floor/wall Pillows Electrical, telephone or data cables. CAJ4079 Max 24 wide cable tray with electrical, telephone or Concrete floor/wall Composite Sheet data cables. WL4008 Max 18 by 5 steel or aluminum cable tray Gypsum board wall Pillows WL4063 Open ladder aluminum or steel cable tray with Gypsum wall Composite sheet electrical, telephone or data cables. Bus Ducts CAJ6003 Max 23 by 4-1/2 busway. Concrete floor/wall PEN300 WL6005 Max 19 by 5 busway. Gypsum wall Pillows Bottom-of-Wall BW-S-0003 Max. 3/4 joint. Caulk only. Gypsum board/concrete floor ES, LCI Floor-to-Floor FF-D-0001 Max. 1 joint. Caulk over backer rod (both sides). Concrete flooor PEN300 or PEN300SL (top) FF-D-1010 Max. 4 joint. Concrete to concrete floor. 1 and 2 Hr. Concrete floor PEN300 or PEN300SL FF-D-1025 Max 4 joint 3 Hr. Concrete floor AS Spray Floor-to-Wall FW-D-1010 Max. 4 joint. Caulk and backing. 1/4 of sealant. Concrete/Floor/Masonry wall PEN300 or PEN300SL FW-D-1035 Max. 4 joint. Spray and backing. Concrete/Floor/Masonry wall AS200 Head-of-Wall HW-D-0041 Max. 1 joint. Caulk over backer rod. Concrete/Masonry wall ES Concrete slab HW-D-0043 Max. 1 to 2 joint. Optional metal or plastic conduit. Gypsum board/steel deck AS200 Perpendicular wall. HW-D-0079 Max. 3/4 joint. Caulk only. Gypsum board/concrete slab ES HW-D-0086 Max. 1 to 2 joint. Optional metal or plastic conduit. Concrete/Masonry wall AS200 Perpendicular wall. Steel deck HW-D-0103 Max. 3/4" joint. Castle cut gypsum board. Caulk only. Gypsum board/steel deck ES Optional Cafco or Monokote fireproofing HW-D-0194 Max. 3/4" joint. Shaft wall system. Caulk only. Gypsum board shaft wall ES Concrete slab Wall-to-Wall WW-D-0001 Max. 1 joint. Caulk over backer rod. Concrete/Masonry wall PEN300 WW-D-0004 Max. 1 joint. Caulk over backer rod. Concrete/Masonry wall ES Perimeter Fire Barrier Systems CWD2042 Aluminum framed curtain wall with glass/aluminum/ AS Spray stone spandrels. Reduced spandrel panel height and vision panel sill height. CWS1019 Gypsum sheathed/steel stud wall. Glass fiber batts in AS Spray stud cavity. Various finishes: brick/metal/stucco/eifs. Low sill height. CWS1020 Steel backpan. Aluminum framed curtain wall with AS Spray glass/aluminum/stone spandrel panels. Thermafiber products. CWS2061 Aluminum framed curtain wall with glass/aluminum/ AS Spray stone spandrels. Reduced spandrel panel height and vision panel sill height. CWS2062 Aluminum framed curtain wall with glass/aluminum/ AS Spray stone spandrels. 90 degree insulation hangers. Min 2 8 pcf CW insulation. Thermafiber. 3 Hr. Additional CAD details, technical documents, product data sheets and MSDS sheets are available online through our Technical Library! 200 Evans Way Somerville, NJ 08876 Toll Free: 800-992-1180 Fax: 908-526-9623 e-mail: specseal@stifirestop.com SpecSeal, EZ-Path and Triple S are registered trademarks of Specified Technologies, Inc. High-Traffic is a trademark of Specified Technologies, Inc. UL is a registered trademark of Underwriters Laboratories, Inc. Copyright 2007. All rights reserved.