PRY-MOULD. High Voltage Accessories for Extruded Cables

Similar documents
The future of cabling for today s utilities. Enhanced performance. Superior service. Environmental sustainability.

CCC Services for oil-filled- and XLPE-Cable Systems

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Energy Division Insulators

The complete guide to transformers and packaged substations

TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

NEC 2014 Code Changes

3.0) TRANSMISSION LINES MINIMUM REQUIRED STANDARDS LINES

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

INTERNATIONAL STANDARD

Standard of Practice - Campus Electrical Distribution System

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NPS/003/015 Technical Specification for 33kV, 66kV and 132kV Post Insulators

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

UNDERGROUND SERVICES SECONDARY

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Details of technical leaflets/write-up on various pieces of equipment.

PILC Replacement: Getting the Lead Out

INTERNATIONAL STANDARD

Polymer Suspension Insulators 69kV to 765kV

CONTENTS INSTRUCTIONS. UK POWER NETWORKS LV JOINTING MANUAL I Version Section Index I Page 1

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

*** Supercedes: BECO E and COM , , & ***

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

Electrical Insulating Tapes

Integrated Solutions. The food & beverage. for. Global specialist in electrical and digital building infrastructures

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

SECTION GROUNDING AND BONDING

HIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators

B. Provide liquid-filled secondary substation transformers as indicated on drawings.

Product Information. Stress Control Element Insulation. 3M QS 2000E 24kV I DN A

WIRING METHODS CHAPTER 38

Compact Substation Design. Kobus Coetzer TGOOD Africa

SECTION WIRES AND CABLES

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Surge arrester 3EB4. with polymeric composite housing for operating aboard traction units

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS

THE ADVANTAGES HDPE MANHOLES

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

Friday, May 29, Update on Testing Medium Voltage Cable and Switchgear Systems

U.V resistance UL Sunlight Resistance. Flame retardant IEC

Instruction guide Medium Voltage equipment on sites exposed to high humidity and/or heavy pollution. Recommendations for installation and use

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

Resin impregnated paper bushings. Product information

DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv

UNITED NATIONS DEVELOPMENT PROGRAMME ITB

High voltage gas-insulated switchgear and hybrid switchgear, PASS

SECTION MEDIUM VOLTAGE TRANSFORMERS

Design & Construction Standards, Revised January

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

TURKISH ELECTRICITY DISTRIBUTION CO. TECHNICAL SPECIFICATION FOR POST (SUPPORT) INSULATORS FOR MEDIUM VOLTAGE SYSTEMS

SECTION HVAC INSULATION

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

APEC 2016 Component Level Safety Certification in Systems- IEC /UL1577. MARK CANTRELL Senior Applications Engineer

Installation of CSST Gas Piping Systems

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

CONTENTS. IEC Ed. 2 /CDV IEC 2 36B/ /CDV 36B-MT10/Nuremberg3/60

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

SPECIFICATION SHEET JUNCTION BOXES

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

ELECTRICAL BULLETIN

GENERAL PROVISIONS: Furnish and install one steel deck platform motor truck scale and associated electronic controls.

Energy & Data Transmission Systems for Underground Applications

General Requirements. Technical Specifications for Insulators of Transmission Lines

Polymer Post Insulators for 46 to 500kV Applications

15 kv EPR Insulated, Jacketed, URD Cable

Electrical Fasteners. Everything concerning cables

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

Facility Sanitary Sewers

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

DESIGN. DEVELOP. DELIVER. CAPABILITY STATEMENT

Accelerated Aging Tests for MV Cables

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

SECTION INSULATED WIRE AND CABLE

RN Optical Termination Panel (RN OTP)

ABSTRACT EXPERIMENTAL KEYWORDS. INTRODUCTION 1. Introduction Crosslinked polyethylene (XLPE) has been extensively used. samples.

Telecommunication Spaces

«CABLE T 92» WORKSHOP BALI, INDONESIA JUNE, 1992 POWER CABLES IN TROPICAL ENVIRONMENTS : SYNTHESIS. By L. DESCHAMPS SEE / EDF (France)

Valmont Newmark is your single source for steel, concrete or hybrid structures for power delivery

PREINSULATED PIPE SYSTEMS FOR HOT WATER NETWORKS

The Flygt 2600 dewatering pump series. The new force in dewatering

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

40'-0" PIPE SUPPORT (TYP.) (SEE DWG. NO. SK-2 OR DWG. NO. SK-4)

SECTION PACKAGE BOOSTER PUMP STATIONS

Performance Analysis of 33 kv Polymer and Porcelain Insulators under Various Pollution Conditions at Costal Regions

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

Unit Substation Transformer Construction Checklist (under 500 kva)

Transcription:

PRY-MOULD High Voltage Accessories for Extruded Cables

Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of communities. With this in mind, we provide major global organisations in many industries with best-inclass cable solutions, based on state-of-the-art technology. Through two renowned commercial brands - Prysmian and Draka - based in almost 100 countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable growth. In our energy business, we design, produce, distribute and install cables and systems for the transmission and distribution of power at low, medium, high and extra-high voltage. In telecoms, the Group is a leading manufacturer of all types of copper and fibre cables, systems and accessories - covering voice, video and data transmission. Drawing on over 130 years experience and continuously investing in R&D, we apply excellence, understanding and integrity to everything we do, meeting and exceeding the precise needs of our customers across all continents, at the same time shaping the evolution of our industry. What links power grids to sustainability? From Asia-Pacific to the Americas, and from Europe to the Middle East to Africa, Prysmian cable solutions sit at the heart of the development of power grids worldwide, helping major utilities in transmitting and distributing power to their customers. Unmatched in our manufacturing capabilities and with unwavering commitment to R&D, we design, produce and install low, medium, high and extrahigh voltage underground and submarine cables and systems, along with network components and value-added engineering services. Always aware of the need to minimize our impact on the planet, we re constantly driving innovation in our industry, aiming to optimize supply chain processes, reduce total cost of ownership for our customers and help them achieve sustainable, profitable growth.

PRY-MOULD accessories for extruded cables Introduction and concept High Voltage accessories based on prefabricated mouldings represent a highly reliable solution that is considered a key component in the safe operation of an HV cable system. The PRY-MOULD concept dates back to 1978 when the Group, strong of its very long and successful experience in Fluid Filled cable systems, developed their first generation of accessories, designed to connect High and Extra High Voltage extruded cables. Pre-moulded sleeves and stress cones are currently available for HV extruded cables from 72.5 kv up to 525 kv and adopt the same design at all voltage classes. Thanks to outstanding electrical and mechanical properties, Ethylene-Propylene Rubber (EPR) has been favoured for the rubber mouldings manufacture. The integrated semi-conductive silicone rubber stress control cones and shielding electrode ensure a smoothly distributed electrical field control. The mechanical properties of Prysmian special compounds ensure a constant pressure at the cable/moulding interface during the entire lifetime of the accessories. Prysmian one-piece pre-moulded sleeves and stress cones are completely in-house manufactured.

General Characteristics All PRY-MOULD accessories share some key features: Available for voltage classes U m from 72.5 kv up to and including 525 kv Prefabricated, mechanically and electrically factory tested components Easy to handle, light-weighted tools Short delivery time Worldwide experience in the most severe environmental conditions (-60 C to 50 C, all pollution classes) In-house manufacturing Modular and flexible design, allowing tailor made solutions Products Available for cable systems with maximum system voltage U m (kv) Description Code 72.5 123 145 170 245 300 420 525 Premoulded Sectionalised Joint GMS Premoulded Unsectionalised Joint Sixty Speed /Oneten Speed (pre-expanded) Sectionalised Joint Sixty Speed /Oneten Speed (pre-expanded) Unsectionalised Joint Porcelain Outdoor Termination (Wet type) GMC GSS GSC TPE Composite Outdoor Termination (Wet type) TES SF6 Immersed Termination (Dry type) EGS SF6 Immersed Termination (Wet type) EVG Oil Immersed Termination (Dry type) EOS Oil Immersed Termination (Wet type) EVO

PRE-MOULDED JOINTS The PRY-MOULD joint is a one-piece pre-fabricated and factory pre-tested joint, designed to connect two High Voltage extruded insulation cables. The cable ends are connected to each other by means of compression, MIG-welding or shear-off bolts. To protect the joint different types of covering (which ensure mechanical protection, protection against moisture ingress and external damages) are available: The compact joint covering is based on a copper casing with heat shrinkable tubes. It guarantees a good sealing against water penetration and it is generally chosen for installations in concrete manholes or tunnels The universal joint covering features, in addition, an XLPE protective casing with cold pouring resin. It offers an excellent sealing against water penetration and is normally used in directly buried or fully submersed installations Main features: Straight joints as well as joints with integrated screen interruption for cross bonding purposes. In the case of screen interruption, the metal joint casing is provided with an epoxy-insulating ring. Installation procedures and tools for various site conditions (e.g. manhole, open trench, etc.)

Speed LINE JOINTS Prysmian has taken the major advantages of each type of design available on the market and has developed a new generation of one piece pre-moulded joints that are delivered to final customers with a rubber moulding already expanded (factory expanded) over carrier spiral tubes. The Prysmian Speed product range consists of 2 main joint families: Sixty Speed joints for U m 72.5 kv Oneten Speed joints for U m 123 kv Outer protection is available in the form of heat shrinkable tubes (for Cu wires screens) or copper casing plus heat shrinkable tubes (for metallic sheaths). Totally cold shrinkable solutions are available instead of the heat shrinkable ones for joints up to 72.5 kv. Considerable reduction of installation time and efforts No specific tools needed for the installation Straight joints as well as joints with integrated screen interruption for cross bonding purposes Within the same voltage class, a single joint size applies to a wide range of cable diameters

OUTDOOR TERMINATIONS Prysmian outdoor termination solutions, based on EPR pre-moulded stress cones, include a wide range of products for the connection of underground circuits and overhead lines. The pre-moulded stress cones, available for a wide range of cable sizes, are designed to fit with controlled interference over the cable insulation and to follow the cable s diameter variations. The terminations are filled with an insulating compound up to a level where the electric field is substantially reduced. A recent developments consists in a new patented medium that becomes partially solid within a short time after the filling of the termination, thus avoiding any possibility of leakage 1) PORCELAIN Self-supporting porcelain insulator with sheds Several different creepage distances available Filling with silicon fluid or new patented medium 2) COMPOSITE (POLYMERIC) Light, easy to install and resistant to vandalism Self-supporting insulator of glass fibre reinforced epoxy resin tube, covered with silicone rubber sheds Excellent environmental properties by water repelling silicone outer layer and sheds Several different creepage distances available Filling with silicon fluid (unpressurized, thus no oil or gas pressure monitoring system is required) or new patented medium Prysmian terminations can include optical fibers management and partial discharge sensors upon request Reduction of overall installation time and cost by simple installation procedure and low weight composite insulators.

OIL IMMERSED TRANSFORMER TERMINATIONS Prysmian HV Accessories product portfolio features a complete range of terminations for direct connection to oil insulated transformers based on EPR pre-moulded stress cones. The cable ends are encased in a specially designed and in-house manufactured epoxy resin (Voltalit ) insulator that is to be positioned directly inside the transformer s cable enclosure. Prysmian has developed a special epoxy resin insulator version in which the outer part of the top connector is directly embedded. Both dry and wet solutions available Solutions for non-standard transformer cable enclosure available Plug-in solution for easy removal SF6 IMMERSED GIS TERMINATIONS Prysmian HV Accessories product portfolio features a complete range of terminations for direct connection to Gas Insulated Switchgears based on EPR pre-moulded stress cones. The cable ends are encased in a specially designed and in-house manufactured epoxy resin (Voltalit ) insulator that is to be positioned directly inside the GIS enclosure. Prysmian has developed a special epoxy resin insulator version in which the outer part of the top connector is directly embedded. Both dry and wet solutions available Solutions for non-standard GIS enclosure available Plug-in solution for easy removal Possible to install the epoxy insulator inside the GIS in the factory and/or to fill the GIS with gas on site and then complete the installation before the cable head is fitted

OTHER PRODUCTS Additional equipment, such as link boxes, grounding sets and installation tools can be supplied. Link Boxes Single phase and three phase cross bonding and single point bonding earthing design with and without surge voltage limiters single core and concentric bonding cable connections boxes and cabinets, including stainless steel box for wall or floor mounting, suitable for indoor, outdoor and underground installation RELATED SERVICES Accessories for power cables with integrated Optical Fiber All accessories can be provided, with connections for optical fibers integrated in the power cable. Partial discharge sensors All accessories can be provided with integrated partial discharge sensors. Tailor made solutions for specific needs (such as optimised installation, modified accessories to meet special demands) Engineering Special tools Training and certification of jointers Supervision Installation Diagnostics and testing of installed components Partial Discharges monitoring performed with Prysmian s unique PryCam system

TEST AND QUALIFICATION PROGRAMMES Prysmian High Voltage Accessories quality system complies with both ISO 9001 and ISO 14001 standards. Integrity of all Prysmian Products is thoroughly proven by comprehensive programmes. These validation programmes include items such as: Electrical routine test on each individual accessory body Type tests according to international standards (IEC-60840, IEC 62067, IEEE 404, IEEE 48, NEN 3629) witnessed by independent institutes - Reports available on request. Long term development and prequalification tests up to 550 kv Statistical evaluation of impulse breakdown tests Short circuit tests Compatibility of materials Electrical field calculations Thermo-mechanical stability

Linking power grids to sustainability Prysmian Group Viale Sarca 222, 20126 Milan, Italy Email: marketing.energy@prysmiangroup.com www.prysmiangroup.com