Tuff Toilet TM. Please comply with any local government regulations that may be in force in your area when installing your new Tuff Toilet.

Similar documents
The Schools Ecological Sanitation Programme 2. Building an Arborloo. Peter Morgan and Annie Shangwa June 2008

first flush water diverters water quality first downspout, post/wall mounted and in-ground diverters

Appendix G: Sanitation Project. Objective:

How to make a simple pit toilet and grow trees or make humus for the garden. Written by Peter Morgan

Appendix 4. Bills of Quantities

SECTION A1 EXCAVATION AND BACKFILL GENERAL

40 The Double Pit Latrine

6. Urine-Diverting Toilets

Ventilated Improved Pit (VIP)

Garage Conversions. Technical Issues

SWIMMING POOL PERMIT AND INSPECTION REQUIREMENTS

MODULAR ACOUSTIC FENCING INSTALLATION GUIDE

GUIDELINES FOR SANITARY DESIGN AND CONSTRUCTION OF MILK PRODUCTS PLANTS (rev )

These installation instructions cover the installation and operation of Jetmaster Inset and Freestanding Barbecues

Installation instructions

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

DPI&F note. Grain Storage - Steel Mesh Silos for on-farm Grain Storage

Electric Service Standards

LeaPPS Uganda Learning for Practice and Policy on household and school sanitation and hygiene Arborloo and Fossa Alterna

Original Scandinavian rainwater system

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

University of New Mexico Environmental Services Design & Development Standard Requirements

ROOF MOUNT KIT OWNERS MANUAL

Daytona Beach Pier Building Renovation Jun 2010

TYPICAL INSTALLATION INSTRUCTIONS

CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS Square Line Rainwater System 3-5. Half-Round Rainwater System 6-8. Ogee Rainwater System 9-11

R10 RAINWATER DRAINAGE SYSTEMS

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

RIVER. 65 EBD Soil Pack Units 17 EBD River Pack Units. Raw Sewage Treatment Using Freytech EBD Technology Raw Sewage Tanks. Slaughter House Tanks

SECTION EXCAVATING, BACKFILLING, AND COMPACTION FOR UTILITIES

CONTENTS INTRODUCTION 2 FREEFLOW RAINWATER SYSTEMS Square Line Rainwater System 3-5. Half-Round Rainwater System 6-8. Ogee Rainwater System 9-11

11. Construction processes and materials Power House Maintenance Building Fuel Treatment Building...

INSTALLATION INSTRUCTIONS FOR WICANDERS HYDROCORK

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

SECTION FACILITY SANITARY SEWERS

Installation instructions

SI T T FST

Vertigo Cladding Board

The Otji-Toilet self builder manual The Clay House Project Otjiwarongo

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

CHAPTER 3 GENERAL REGULATIONS

TECHNICAL INFORMATION SHEET NUMBER 1a

Commercial Medical Marijuana Operation Design Guidelines

P U B L I C H E A L T H P R O T E C T I O N. Ministry of Health and Ministry Responsible for Seniors

Topic: Site Formation

SECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION

Easy Drain. Modulo. TAF Side outlet INSTALLATION MANUAL FOR WOODEN OR CONCRETE SUBFLOORS

6.1 Introduction to Wastewater Issues


LATRINE CONSTRUCTION SHELTER. Pour flush latrine 2. Pour flush micro septic tank 3. Initial investment, location, human resources 4.

SPECIAL CONDITIONS FOR PIPE JACKING (PJ) October, 2006

Freedom One-Piece Barrier Free Showers Installation Instructions

BUILD A SHOWER CUBICLE

ASEAN Guidelines on GMP for Traditional Medicines / Health Supplement

Extended Detention Basin Maintenance Plan for [[== Insert Project Name ==]]

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

RCC PRECAST TOILET UNITS

TEMPORARY FACILITIES

Minimum grade (%) Velocity at full flow (m s 1 )

SPECIFICATION : BORING AND JACKING

DICTATOR Lift Shaft System

BioPrism Solid Surface

Y o u r n a t u r a l s o l u t i o n f o r c r o p d r y i n g & s t o r a g e p r o d u c t s o n t h e f a r m

September 1, 2003 CONCRETE MANUAL SPECIAL TYPES OF CONCRETE

Diaphragm wall Construction

Why Do I Need a Permit? D ID Y OU K N OW? Protects property values. Makes Selling Property Easier. Site Plan Page 2. Plan Requirements Page 2

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

Austin Technical Manuals - Standard Specifications Preservation of Trees and Other Vegetation (610S) 03/27/2000

Solar Powered TS1000 Installation Pictures. (Trench and Fill Method) City of Vallejo, CA

K_`j `e]fidxk`fe `j Yifl^_k kf pfl Yp Fncj?Xcc <em`ifed\ekxc nfib`e^ `e gxike\ij_`g n`k_ BcXi^\jk\i gif[lzkj% '/+, *., (/'(

G4S ACADEMY ANTI-RAM AND TERRORISM PROTECTION

A/E Design Deliverable Checklist

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Modular Sediment Barriers (Instream)

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

BUILDING CONSTRUCTION

Annex A STATEMENT OF WORK Radon Mitigation

Natural Gas Service Installation and Meter Clearance Requirements

Attachment A-Flagpole(s) Specifications

Rediflow Concrete Gas Flue System

Foirgniochta. Marking Scheme Leaving Certificate Examination, Ordinary Level. Construction Studies


112mm. 117x75mm Polyflow. 130x70mm Ogee 68mm Round 65mm Square. 112mm Half Round 68mm Round. 65mm. Round. 112mm. 117x75mm Polyflow

olor Match POOL FITTINGS, INC. Blending Beauty & Function

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

By Jerry Turrentine, NRCS Biologist USDA Natural Resources Conservation Service

PROPER CARE OF UNUSED WELLS

Effective Date: 14-March Table of Contents

HYBRID. Pre-Laying Checks

Indoor Building Survey and Product Inventory

WASSCE / WAEC BUILDING CONSTRUCTION SYLLABUS

PROGRAM OVERVIEW WALKING/WORKING SURFACE INDUSTRIAL SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR

MAINTENANCE PLAN Wing Village Hall, Morcott Road, Wing, Oakham LE15 8SA

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

Section 1 OBC FADS /13 Access to Parking Areas

7. Completing the Well s Structure

FREE FROM THE SKY. 2a 4

RAINWATER HARVESTING SYSTEMS

SEMPEO SQA Unit Code FP3G 04 Forming and assembling electrical cable enclosure and support systems

Transcription:

Bellatrines TM Tuff Toilet TM Your new Tuff Toilet is a maintenance free clean toilet system based on the VIP (ventilated improved pit) latrine system in universal use all over the world. A sewer connection is not required, with a suitably sized pit potentially providing many years of service, and odor is removed via the optional vent pipe (the VIP system). The pit latrine is a natural, safe, and clean toilet system, with pit contents decomposing naturally into compost over time. When the pit becomes full the toilet can be moved to an adjacent new pit, and the old pit covered over. The VIP (ventilated improved pit) latrine system is an excellent toilet system, as the VIP vent pipe arrangement ventilates the pit to remove odors, and incorporates a device to trap and kill any flies that may occasionally enter the latrine pit. However, the VIP vent pipe is optional and the toilet functions perfectly normally without it. The Tuff Toilet is designed to be instantly usable by placing it directly on the ground over a suitable pit, but may also be installed over larger more permanent pits, and installed on plywood or concrete floors inside semi-permanent ablutions structures. Please comply with any local government regulations that may be in force in your area when installing your new Tuff Toilet. Bellatrines TM Tuff Toilet TM is manufactured and sold by: BLUEWATER EXTREME LTD 47A Koromiko Street, Tauranga, New Zealand TEL 07 571 5114 FAX 07 571 5142 email: sales@tufftoilet.co.nz website: www.tufftoilet.co.nz 1

Installation Instructions. Installation of your new Tuff Toilet consists of digging a suitable pit, placing the Tuff Toilet commode unit over the pit, and making some facility for privacy in the way of screening, or out-house construction of some type. Please read the following detailed installation instructions in full before starting to install your new Tuff Toilet. See www.tufftoilet.co.nz for information on: Bellatrines out-house tent. Bellatrines relocatable out-house. 1. Choose a Location. Choose a suitable location for your new Tuff Toilet which is clear of buildings, trees, etc that may interfere with the airflow across the top of the vent pipe. The Tuff Toilet should be located on flat ground, ideally slightly elevated to ensure that rainwater will not drain into the pit. Do not site the Tuff Toilet on low ground where run-off water will drain into the latrine pit potentially causing overflow. A raised earth step/foundation around the pit for the Tuff Toilet to sit upon will also help to prevent rainwater from entering the pit. Important: The effectiveness of the vent pipe in ventilating the latrine pit and removing odors is directly related to the exposure of the top of the vent pipe to wind moving over it and creating a suction. Choosing a location where the vent pipe is not sheltered by structures or trees is important. Important: Ensure that there are no utilities (pipes or cable) in the proposed area of your pit. 2

2. Digging your pit. The pit can be dug by hand or mechanically. The bigger the pit the better, and the deeper the better. The deeper the pit, the more sanitary the toilet will be. When using the Tuff Toilet commode unit, the pit should be a minimum size of 500mm x 500mm square (or 500mm diameter for a circular pit), and a maximum of 900mm x 900mm square (or 900mm diameter for a circular pit). The pit should be as deep as possible, ideally about 2 meters deep. As this is impractical when manually digging a pit for short term emergency use, any depth beyond 800mm deep will suffice. When the time comes to close the pit, it is recommended (public health recommendation) that there should be space for 500mm of covering soil in the hole, so the pit depth should make allowance for this. When determining the size and depth of your pit it is necessary to consider the number of people using the toilet and how long a service life is required. Allow a volume of at least 0.06 m 3 per person per year. Important: The recommended pit digging method is to use a bobcat* with a 600mm diameter auger to mechanically bore a hole 2.2 meters deep (standard auger depth). This method is quick and cost effective, produces a pit with the capacity to serve a family of five people for over a year, and is deep enough to result in a very clean and sanitary toilet installation. See www.tufftoilet.co.nz for a list of Bellatrines accredited bobcat* companies in your area. *A bobcat is a small and portable earthworks machine operated by landscape contractors. If you wish to choose a different pit than the recommended method above, then please refer to the more detailed information contained in Tables 1 & 2 in the section Pit Capacity (Volume) and Dimensions. It is recommended to support the top part of the pit against collapse. The top 500mm (or more) should be supported with a liner or pit-collar if possible. The pit-collar can be made from any material, e.g. timber (treated), plastic or steel sheet, plastic pipe, a metal drum, concrete, plaster, or even brick in the case of a large pit. In the case of loose soils or sand it may be necessary to line the pit in it s entirety. Important: All pits, particularly deep narrow pits, are extremely hazardous for people and animals. NEVER LEAVE A PIT UNCOVERED and always mark pits with an obvious sign or object 3

Digging your pit (continued). As stated, it is important to exclude rainwater run-off from draining into the pit. If there is a possibility that run-off water may enter the pit, or if the water table is very shallow, then it may be useful to make a raised beaten-earth (hard packed) or concrete step/foundation around the pit. This raised step/foundation must be level, flat, square and suitable for the Tuff Toilet commode unit to sit upon. Most soils can be stabilised and made more resistant to water by the addition of a small amount of cement (Sprinkle cement over damp dirt and mix through, repeat several times to a maximum of 10% cement, then hard pack the soil as required. Clay based soils are best). 3. Installing your Tuff Toilet commode unit. The Tuff Toilet commode unit is designed for use directly on the earth/ground over a latrine pit, and this surface must be suitably flat and level. Carefully install the Tuff Toilet commode unit over the latrine pit, with the commode seat centrally located over the center of the pit opening. If installing the VIP vent pipe (highly recommended) then ensure that the vent pipe socket of the Tuff Toilet commode unit is over the pit opening and clear of any obstructions which may hinder good ventilating airflow up the vent pipe. Ensure that there is a good fit of the commode unit to the ground, and that there are no gaps under the commode unit which may allow entry to vermin or affect the pit ventilation airflow. The front of the Tuff Toilet commode unit (i.e. where the door will be) should be orientated facing towards any prevailing breezes, or towards an open area of airflow. This orientation is to assist the ventilation of the toilet and latrine pit and reduce possible odor. Do not orientate the door towards an immediately adjacent obstructing structure like a fence. 4

4. Installing the Vent Pipe. The VIP (ventilated improved pit) latrine system depends upon the vent pipe to promote air circulation through the toilet, the pit, and out through the vent pipe for the purpose of reducing any odors that may otherwise accumulate in the toilet space. This airflow is induced by wind movement across the top of the vent pipe creating a venturi effect suction, and by convection due to sunlight heating the pipe. The vent pipe has an insect screen on the outlet to prevent the entrance of any flies, and any flies that may enter the pit through the toilet are attracted up the pipe to the bright sunlight and are trapped, eventually dying and fall back into the pit. If installing the VIP vent pipe (highly recommended), remove the seal plug from the vent pipe tapered socket at the rear of the Tuff Toilet commode unit. Position the vent pipe vertically and insert the vent pipe into the tapered socket. Fit the support bracket around the vent pipe and position it in alignment with the two mounting holes on the upper rear area of the Tuff Toilet commode unit. Hint: Check that the vent pipe ends are cut square and cleanly to ensure a good fit and seal in the tapered socket. Hint: Run a bead of white silicon sealant around the vent pipe in the tapered socket to fill the small gap. Clean off any excess silicon sealant immediately with a rag wet with mineral turpentine. Note 1: Vent Pipe: 100mm DWV (Drain Waste & Vent) pipe, 2.9 meters long. IPLEX / Marley 100mm DWV Pipe, AS/NZS 1260:2002 PVC-U pipes and fittings for drain, waste and vent application. Note2: 100mm DWV pipe is larger (outside diameter) than the 100mm nominal size, being approximately 110mm outside diameter. Note 3: Support Bracket for Vent Pipe: IPLEX STAND OFF KEY CLIP, IPLEX Order Code 143.100. See picture below. 5

Installing the Vent Pipe (continued). Fit the insect screen over the top end of the vent pipe and secure in place with the circular plastic clip supplied. See diagram below. Important: The vent pipe must also be supported at the top end of the pipe, for example, where the vent pipe passes through the roof of the out-house tent or construction. Important: The vent pipe should be a minimum of 500mm above the top of the outhouse structure to ensure unobstructed airflow. 6

5. Shelter Construction In situations where building materials are not immediately available, a fabric structure such a canvas privacy screen or a tent can be erected to provide immediate privacy and shelter requirements. For longer term use, a solid shelter should be constructed in accordance with the following guidelines and recommended practices. 1. For best performance of the VIP vent pipe system the entrance doorway should face the prevailing wind (or an open area of airflow) to maximise airflow into the shelter, through the toilet & pit, and up through the vent pipe. 2. To give best odor control, the shelter must provide a free through-flow of air at all times, so some type of ventilation gaps above and/or below the door is beneficial. 3. To ensure undisturbed airflow across the top of the vent pipe, the vent pipe should exceed the height of the shelter by a minimum of 500mm. 4. To promote the absence of flies, the inside of the shelter should be as dark as possible. Avoid windows or skylights and limit light entering through ventilation gaps. This darkness in the shelter is so that a fly in the pit sees the open top of the vent pipe as the brightest object and follows the light up the tube to be trapped, die, and fall back into the pit. Using a light when using the toilet is allowed. General use and maintenance. Tuff Toilet / VIP latrines requires a minimum level of day-to-day maintenance. The most important aspects are air circulation and cleanliness. 1. If fitted, the toilet seat seat cover should always be left in the UP position so that airflow into the pit is not restricted. 2. The external surface of the Tuff Toilet unit should cleaned and disinfected regularly in the same manner as regular household toilets. 3. To prevent the breeding of mosquitos, the pit should be kept as dry as possible. Do not spray water into the pit during cleaning. 4. Do not add disinfectant to the pit, as this will arrest natural decomposition/composting processes. 5. Do not deposit cans, glass, plastic or other foreign objects into the pit. 6. The fly screen must be checked regularly for damage and/or obstruction and replaced if necessary. (The openings in the fly screen should not be smaller than 1.2mm x 1.5mm so that airflow is not restricited.) 7. The pit is full when the contents reach a level of 500mm below the top of the pit. The pit must be filled in with soil and a new VIP latrine pit constructed. 7

Pit Capacity (Volume) and Dimensions. The following tables provide a range of pit dimensions versus pit capacity (volume). When calculating the volume required for your latrine pit, a volume of at least 0.06 cubic meters per person for each year of use is recommended. 500mm must be allowed for soil in-fill when the pit is ultimately closed (public health recommendation), and this has already been accounted for in the below figures. It is important to note that the deeper the pit, the more sanitary the latrine will be. The deeper in the ground that the pit contents are will result in a more pleasant toilet above. Particularly in the case of mechanically bored circular pits, ensure that the pit hole is bored as deep as the auger allows. Table 1: Latrine pit minimum depth for 1 years service. Number of people using the toilet per day. 5 people 10 people 20 people 50 people 500mm diameter circular pit 2000mm - - - 500mm x 500mm square pit 1700mm 2900mm - - 600mm diameter circular pit 1500mm 2500mm - - 600mm x 600mm square pit 1200mm 2100mm - - 700mm diameter circular pit 1300mm 2100mm - - 700mm x 700mm square pit 1100mm 1700mm 2900mm - 800mm diameter circular pit 1100mm 1700mm 2300mm - 800mm x 800mm square pit 1000mm 1400mm 1850mm 2400mm 900mm diameter circular pit 1000mm 1500mm 2000mm 2500mm 900mm x 900mm square pit 1000mm 1300mm 1700mm 2100mm Table 2: Latrine pit minimum depth for 2 years service. Number of people using the toilet per day. 5 people 10 people 20 people 50 people 500mm diameter circular pit - - - - 500mm x 500mm square pit 2900mm - - - 600mm diameter circular pit 2600mm - - - 600mm x 600mm square pit 2100mm - - - 700mm diameter circular pit 2000mm - - - 700mm x 700mm square pit 1700mm 2900mm - - 800mm diameter circular pit 1700mm 2900mm - - 800mm x 800mm square pit 1400mm 2300mm - - 900mm diameter circular pit 1500mm 2400mm - - 900mm x 900mm square pit 1250mm 2000mm 2750mm - Note: The pit contents are continually decomposing and reducing in volume. For pit toilets serving the public or high traffic locations that have large pits (e.g. 1.5m x 1.5 meters x 3.0 meters deep, or larger), the composting action renders such toilets as more or less permanent. 8