Summer 2017 Capacity Assessment

Similar documents
Wes Yeomans Vice President Operations Management Committee May 31, 2017 COPYRIGHT NYISO ALL RIGHTS RESERVED

Appendices. New York Control Area Installed Capacity Requirement. December 2, For the Period May 2017 To April 2018

Gas-Electric Coordination A NYISO Perspective

Capacity Resource Performance in NYISO Markets

Operations Performance Metrics Monthly Report

Capacity Performance Training. March 16, 2015

Comparison of Installed Capacity (ICAP) & Unforced Capacity (UCAP) Capacity Value Calculation Methods. Eligibility WG Meeting #3 July 4, 2017

Sustaining & Enhancing Reliability in NY

Requirements for Real and Reactive Power Testing

Demand Response. Mathangi Srinivasan. New York Market Orientation Course (NYMOC) Senior Market Trainer, NYISO. March 20-23, 2018 Rensselaer, NY 12144

Summary details for SPC TSR # and MH TSR # are shown in Tables ES.1 and ES.2: Service Requested

Summary details for SPC TSR # and MH TSR # are shown in Tables ES.1 and ES.2: IFHS MH MW, firm :00:00 CS

Load Forecasting Manual

Installed Capacity Manual. August 2017

Capacity Performance Training. June 24, 2015

Generator Deactivation Assessment Indian Point Energy Center. A Report by the New York Independent System Operator

LOLE Fundamentals Loss of Load Expectation (LOLE) Fundamentals

ERCOT in 2018: Challenges & Opportunities

PJM Manual 21: Rules and Procedures for Determination of Generating Capability Revision: 12 Effective Date: January 1, 2017

ConOp. Internal NYISO Controllable Lines. Concept of Operation. Scott Harvey, LECG. Document Locator:

2006 Long-Term Reliability Assessment. The Reliability of the Bulk Power Systems In North America

APRIL 23, Capacity Value of Wind Assumptions and Planning Reserve Margin

Electricity Supply. Monthly Energy Grid Output by Fuel Type (MWh)

Energy Storage in the U.S.

LOLE is expressed as hours per year with the usual target criteria being (0.1 days/year) or 1- day in 10-years MISO Tariff: Module E-1 - The

Quarterly Report on the New York ISO Electricity Markets First Quarter of 2017

Locational Based Marginal Pricing

Internal NYISO HVDC Controllable Line Scheduling. Concept of Operation. LECG Staff

Gas-Electric Coordination in PJM: Trends, Issues, Interactions, and Looking Ahead

Outage Types and Entering Tickets PJM State & Member Training Dept.

Con Edison. Evolution of Con Edison efforts in Energy Efficiency and Demand Management:

California Independent System Operator Corporation Fifth Replacement Tariff

2016 State of the Market Report: Energy & Ancillary Services Market Highlights

Standard BAL-502-RFC-02

DEMAND PEAK FORECAST SUPPLY RENEWABLES IMPORTS OPERATING RESERVE SUMMER LOADS AND RESOURCES ASSESSMENT. March 15, 2012

Draft Results Capital Cost and Performance of New Entrant Peaking Unit

Oregon. May 28, Via Electronic Filing OREGON PUBLIC UTILITY COMMISSION ATTENTION: FILING CENTER PO BOX 1088 SALEM OR

Hourly values for at least the next 48 hours. Daily values for at least the next 31 calendar days.

SPP at a Glance. Located in Little Rock. Approximately 600 employees

Quarterly Report on the New York ISO Electricity Markets Second Quarter of 2017

Congestion Assessment and Resource Integration Studies. A Report by the New York Independent System Operator

AGENDA. Meeting No. 18 NPCC Governmental/Regulatory Affairs Advisory Group

MOD-001-1a Available Transfer Capability Implementation Document

Summary of 2016 MISO State of the Market Report

ELECTRICITY GENERATION

Beacon Power, LLC Response to the New York Energy Highway Request for Information (RFI) May 30, 2012

RPM 301 Performance in Reliability Pricing Model

Introduction to the PJM Markets

2017 Summer Reliability Assessment

RE: Initiating Near Term Transmission Components of the Central Toronto Integrated Regional Resource Plan

California ISO Preparing California for a Greener and Smarter Grid

TRC Solutions. Cost and Feasibility Analysis of a Third Converter Station for the Champlain Hudson Power Express Project

2015 Summer Reliability Assessment

The Polar Vortex and Future Power System Trends National Coal Council Annual Spring Meeting May 14, 2014

2016 Long-Term Reliability Assessment

Transmission and Dispatching Operations Manual. October 2017

Standard TPL Transmission System Planning Performance Requirements

1.818J/2.65J/3.564J/10.391J/11.371J/22.811J/ESD166J SUSTAINABLE ENERGY. Prof. Michael W. Golay Nuclear Engineering Dept.

2018/2019 RPM Base Residual Auction Planning Period Parameters

California Grid Operations: Current Conditions and Future Needs

BC Hydro Revenue Requirements Application Information Request #1

the Real-Time Market will be based on the system marginal costs produced by the Real-Time

New England States Committee on Electricity

Operating Procedure PURPOSE... 1

2750 Monroe Blvd Audubon, PA

ISO New England Available Transfer Capability. Implementation Document. Version 1.0

Methodology for Calculating Operating Limits for Generators

Standard Development Timeline

Certification and Training Requirements

Update: Assessment of the Clean Power Plan Proposal

Solar Impact on Grid Operations - An Initial Assessment

PJM Capacity Repricing Market Design Initiatives

Integrated Grid Planning Symposium

May 4, 2017 PLANNING COMMITTEE. Dear Committee Members:

NCSL Transmission Policy Institute Denver, CO

SPP Emergency Operations: 2016 Summer Preparedness Workshop

Integrating variable renewables: Implications for energy resilience

2014 Summer. Assessment. Demand Generation Generation Outages Renewables Generation Imports

Understanding Hourly Electricity Pricing. NYSERDA Programs

2011 Congestion Assessment and Resource Integration Study

1st International Conference on Large-Scale Grid Integration of Renewable Energy in India Durgesh Manjure, MISO Energy September 6, 2017

LOAD SERVING ENTITIES PJM REGION

Business Practice Manual RESOURCE ADEQUACY Planning Years 2013 and beyond

Functional Entity Roles and Responsibilities

The Optimisation of the supply-demand balance, the role of interconnections, and the impact of nuclear shutdown in Germany for EDF

LIPA Generation Planning Review

PJM Manual 22: Generator Resource Performance Indices Revision: 17 Effective Date: April 1, Prepared by Resource Adequacy Planning

Rules and Procedures for Determination of Generating Capability

PJM Manual 18: PJM Capacity Market Revision: 38 Effective Date: July 27, Prepared by Capacity Market Operations

Maintenance and Planned Outages Capacity Accreditation Under Seasonal Construct Workshop Agenda Item 03c, 3d, 3e.

Importance of Intra-day Forecasts in Renewable Energy Sector to Reduce Imbalance & Congestion Costs in UK Power Grid

Northwest Power Pool Processes

RISK OF A CAPACITY SHORTAGE IN THE POLISH ELECTRICITY SYSTEM UP TO 2020

Power Technology Issue 124

ANNUAL REPORT ON MARKET ISSUES & PERFORMANCE

Renewable Integration at ERCOT

PJM Proposal for Incremental Auction Redesign

Connecting New Generation in New Zealand. Len Gould Customer Services Manager Transpower New Zealand Ltd

A. Introduction Balancing Authority Reliability Coordinator Transmission Operator. 5. Effective Date:

Transcription:

Summer 2017 Capacity Assessment Wes Yeomans Vice President - Operations NYISO Management Committee May 31, 2017

Highlights This summer capacity assessment utilizes a deterministic approach for approximating capacity margins and operating reserves for baseline and extreme weather conditions. NERC Standard TOP-002-2.1b Normal Operations Planning, Requirement 7: Each Balancing Authority shall plan and secure sufficient day ahead capacity to secure for the single largest contingency The assessment utilizes a set of projected derates based on five-year EForD averages At baseline peak weather conditions: +386 MW of capacity margin surplus, a decline of 746 MW over the baseline 2016 forecast. This is the projected capacity margin above the baseline peak load plus 2,620 MW of operating reserves. At extreme weather conditions: (90 th percentile forecast): -1,924 MW of capacity margin shortfall, a decline of 733 MW compared to the 2016 extreme weather forecast. This is the projected shortfall for the 90 th percentile load plus 2,620 MW of operating reserves.

2016 & 2017 Summer Capacity Assessment & Comparison 2016 2017 Line Item 2016 Baseline 2016 90th Percentile 2017 Baseline 2017 90th Percentile 1a Summer Generation Capacity 1 38,534 38,534 37,609 37,609 1b SCR - ICAP Values 1,248 1,248 1,191 1,191 1c Net Purchases & Sales 2,092 2,092 2,213 2,213 1 Total Capacity Resources 41,874 41,874 41,013 41,013 2 Assumed Unavailable Capacity (Gen + SCR) 2-4,762-4,762-4,829-4,829 3 = 1 + 2 Net Capacity Resources 37,112 37,112 36,184 36,184 4 Peak Load 33,360 35,683 33,178 35,488 5 Operating Reserve Requirement 2,620 2,620 2,620 2,620 6 = 4+5 Total Capacity Requirement 35,980 38,303 35,798 38,108 7 = 3-6 Capacity Margin 3 1,132-1,191 386-1,924 1. Reflects the 2017 Gold Book existing capacity less projected deactivations during the summer of 2017 and known forced outages 2. Derates: 1,418 MW for wind, 561 MW for Hydro, 2,444 MW for thermal units, 56 MW for other renewables and 350 MW for SCRs 3. While the assessment shows a deficiency of 1,924 MW for the 90 th percentile load forecast, no involuntary load curtailment is forecast to occur because it is expected that there may be up to 3,083 MW available under Emergency Operating Procedures.

Southeastern New York 1 : Summer Transmission Security - Base Case Line Item 1 - Southeast Region includes Zones G to J 2 - All generation capability less known forced outages 2017 Baseline 2017 90th Percentile 1a Available Generation Capacity Resources 2 13,236 13,236 1b Net ICAP External Imports 315 315 1c Transmission Capability from UPNY to SENY (N-1-1) 3,180 3,180 1d Transmission Capability, Long Island to SENY 50 50 1 Total Capability 16,781 16,781 2 Projected Capacity Outages 0 0 3 = (1-2) Total Capability 16,781 16,781 4 Load in Zones G to J 16,055 16,991 5 = (3-4) Capacity Margin w/o SCR 726-210 6 SCR GHIJ 458 458 7 = (5+6) Capacity Margin w/ SCR 1,184 248

Zone J, NYC: Summer Transmission Security - Base Case Line Item 1 - All generation capability less known forced outages 2017 Baseline 2017 90th Percentile 1a Available Generation Capacity Resources 1 8,140 8,140 1b Net ICAP External Imports 315 315 1c Transmission Capability from Sprainbrook to Dunwoodie (N-1-1) 2,800 2,800 1d Transmission Capability, Long Island to NYC 300 300 1e Transmission Capability, A/B/C 400 400 1 Total Capability 11,955 11,955 2 Projected Capacity Outages 0 0 3 = (1-2) Total Capability 11,955 11,955 4 Load in Zone J 11,575 12,064 5 = (3-4) Capacity Margin w/o SCR 380-109 6 SCR J 372 372 7 = (5+6) Capacity Margin w/ SCR 752 263

2017 Emergency Operating Procedures Procedure Effect 2017 MW Value Emergency Demand Response Programs Voltage Reductions Voluntary Industrial Curtailment General Public Appeals Load Impact Load Impact Load Impact Load Impact 13 547 125 88 Emergency Purchases Additional Resources 1,000 Allow Operating Reserve to Decrease to Thirty Minute Reserves to Zero Largest Single Contingency 1,310 Total Emergency Operating Procedures 3,083

NYISO Summer Preparedness Review summer operating conditions with NY Transmission Owners Transmission maintenance is scheduled and coordinated during this spring time period NYISO has worked with the NY utilities to understand the terms, conditions, and projected responses of the utility demand response programs. Review summer operating conditions with the adjacent operating areas Adjacent operating areas are projecting ability to serve load throughout summer and heat wave conditions assuming expected performance of generation and transmission infrastructure NYISO Market Mitigation & Analysis Department has completed many generation site visits to review preventative maintenance work, fuel capability, and summer operating preparedness. 26 Stations including 77 units & 13,000 MWs

MW New York Control Area Seasonal Peaks: 2000-2016 40,000 38,000 36,000 34,000 2013 Record Summer Peak: 33,956 MW 32,000 30,000 28,000 26,000 2014-15 Record Winter Peak: 25,738 MW 24,000 22,000 20,000 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Actual Summer Peak Actual Winter Peak Weather-Adjusted Summer Peak NOTE: Winter dates reflect the first year of the winter season (i.e., 2013-2014).

MW 38,000 New York Control Area Summer Peaks: 2000-2015 Including Impacts of Demand Response 36,000 34,000 32,000 30,000 28,000 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 Actual Summer Peak DR Impacts Weather-Adjusted

The Mission of the New York Independent System Operator is to: Serve the public interest and Provide benefit to stakeholders by Maintaining and enhancing regional reliability Operating open, fair and competitive wholesale electricity markets Planning the power system for the future Providing factual information to policy makers, stakeholders and investors in the power system www.nyiso.com 10