METHCATHINONE Latest Revision: July 11, 2005

Similar documents
1-(2-fluorophenyl)-2-(methylamino)propan-1-one

2023 Reduction of D-(+)-camphor with lithium aluminium hydride to an isomeric mixture of (+)-borneol and ( )-isoborneol

Polyvidone Polyvinylpyrrolidone H 2 C H C N

Certified Reference Material - Certificate of Analysis

Substrate Selective Amide Coupling driven by Encapsulation of a Coupling Agent within a Self-Assembled Hexameric Capsule

Method of determination of phthalates by gas chromatography / mass spectrometry in wines

Formulas: See Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1. METHOD: 2555, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March 2003

CHROMATOGRAPHY/MASS SPECTROMETRY

HEPARIN CALCIUM. Heparinum calcicum

Gas Chromatography Assignment Chem 543/443

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Correlation between the Structure and Catalytic. Activity of [Cp*Rh(Substituted Bipyridine)] Complexes for NADH Regeneration

Determination of organochlorine pesticide residues in eggs by gel-permeation chromatography (GPC) cleanup and GC-ECD

Electronic Supplementary Information. Synthesis and crystal structure of a rare square-planar Co (II) complex of a hydroxyamidinate ligand.

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Effective immobilisation of a metathesis catalyst bearing an ammonium-tagged NHC ligand on various solid supports

Capillary GC Troubleshooting: a Practical Approach

Preparation and X-ray analysis of 2,3-dichlorophenylglucosinolate

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

HYDROCARBONS, BP C 1500

International Journal of Pharma Research & Review, Feb 2014; 3(2):11-16 ISSN:

» Talc is a native, hydrous magnesium silicate, sometimes containing a small proportion of aluminum silicate.

Fast Detailed Hydrocarbon Analysis by Modified ASTM Method D6730

Separation and Quantitation of a Mixture of Alcohols by Gas Chromatography

Colorimetric detection of influenza A (H1N1) virus based on peptide functionalized polydiacetylene (PEP-PDA) nanosensor

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Supporting Information for. Nitric Oxide Reactivity of Copper(II) Complexes of Bidentate Amine Ligands: Effect of. Substitution on Ligand Nitrosation

Supporting Information. Room Temperature Synthesis of Covalent Organic Framework Films by Vapor Assisted Conversion

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

Multi-step and multi-component organometallic synthesis in one pot using orthogonal mechanochemical reactions

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

TITANIUM DIOXIDE. SYNONYMS Titania; CI Pigment white 6; CI (1975) No ; INS No. 171 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Capillary Electrophoresis of Proteins

GC Method Development

Genotoxicity is the property of a compound

ISSN India; g,secunderabad. Abstractt. a flow rate. of 1ml/min. di hydrogen. which acts. and chronic. including minimize (5) Figure

EXPERIMENT 9 DEHYDRATION OF 2-METHYLCYCLOHEXANOL CH 3 H CH 3 OH H 3 PO 4 +

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2

Gunasekar Ramachandran a, Natesan Sundaramoorthy Karthikeyan a, b, Periyasamy Giridharan c, Kulathu Iyer Sathiyanarayanan a *

Optimizing the Purification of a Standard Chiral Compound Utilizing a Benchtop, Multi-Purpose, Semi-Preparative to Preparative HPLC System

MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

Chem-Lab High Purity Solvents

Low-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

Size Exclusion Chromatography

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

for production of 2-[ F]-fluoro-2-deoxy-D-glucose with the

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

Analytical Methods Development and Validation

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF GLATIRAMER ACETATE FOR INJECTION IN PHARMACEUTICAL DOSAGE FORMS

Validated Stability-indicating assay method for determination of Ilaprazole in bulk drug and tablets by high performance liquid chromatography

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Organocatalyzed Oxidative N-Annulation for Diverse and Polyfunctionalized Pyridines. Hari Datta Khanal and Yong Rok Lee* Supplementary Information

PA 800 plus Catalog. Systems/Software

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Solution-processed CdS thin films from a single-source precursor

Agilent Ultimate Plus Fused Silica Tubing

Supporting Information. Low temperature synthesis of silicon carbide nanomaterials using

Pharma Ingredients & Services. Kollidon SR. Technical Information

Supporting Information for

The Simultaneous Analysis of Benzene, Toluene, Ethylbenzene, o,m,p-xylenes and Total Petroleum Hydrocarbons in Soil by GC-FID after Ultra-Sonication

C196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph

Forced Degradation of Ibuprofen in Bulk Drug and Tablets

Fundamentals and Techniques of Preparative HPLC. Parto Zist Behboud Tel: 42108

SCION GC Series. The Gas Chromatographers Choice for Separations

PAL SPME Fibers Optimized for Automation

Provläsningsexemplar / Preview. First edition

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

Quick Manual to the Waters UPLC System

DRPK-005

EXPERIMENT 3: Identification of a Substance by Physical Properties

Research Paper Development of Stability Indicating Reverse Phase HPLC Method for Aripiprazole from Solid Dosage form

Transactions on Ecology and the Environment vol 14, 1997 WIT Press, ISSN

Separation of Recombinant Human Erythropoietin (rhepo) using the European Pharmacopoeia Method on the PA 800 plus Pharmaceutical Analysis System

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Preparative SFC QDa Applications in Natural Products Research Judith M. Rollinger Ulrike Grienke

Qualification of High-Performance Liquid Chromatography Systems

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Types of chromatography

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

Supporting Information. Solid-state mechanochemical ω-functionalization of poly(ethylene glycol)

Supporting information. [Cp*RhCl2]2: Mechanosynthesis and applications in C H bond functionalisations under ball- milling conditions

High Resolution Analysis of Heparin and Heparin-like Impurities on Glycomix TM an Anion Exchange Column

Extraction of POPs from Environmental Samples using Accelerated Solvent Extraction (ASE )

Comparison of Different Brands of Carrier Ampholytes for Monoclonal Antibody Charge Heterogeneity Analysis by Capillary Isoelectric Focusing

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

PROCEDURE FOR USE NICKEL NTA Magnetic Agarose Beads (5%)

STANDARD OPERATING PROCEDURES

NPTEL VIDEO COURSE PROTEOMICS PROF. SANJEEVA SRIVASTAVA

AnaTag HiLyte Fluor 647 Protein Labeling Kit

Solutions Unit Exam Name Date Period

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

2.4 Period 3. Na Mg Al Si P S Cl Ar

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Test Report no. 094/ April 2007 pages 10. Compatibility of Gylon with Perfluorpropane (C 3 F 8 )

Transcription:

METHCATHINONE Latest Revision: July 11, 2005 O CH 3 HN CH 3 1. SYNONYMS CFR: Methcathinone CAS #: Base: 5650-44-2 Hydrochloride: 49656-78-2 Other Names: N-methylcathinone Methylcathinone 2-Methylamino-1-phenyl-1-propanone -Methylaminopropiophenone -N-methylaminopropiophenone Monomethylpropion Ephedrone 2-(Methylamino)-1-phenylpropan-1-one 2. CHEMICAL AND PHYSICAL DATA 2.1. CHEMICAL DATA Form Chemical Formula Molecular Weight Melting Range ( C) Base C 10 H 13 NO 163.2 Liquid at room temperature Hydrochloride C 10 H 13 NO.HCl 199.6 176-177 2.2. SOLUBILITY Form A C E H M W Base SS FS SS I FS SS Hydrochloride VSS FS I I FS FS

A = acetone, C = chloroform, E = ether, H = hexane, M = methanol and W = water, VS = very soluble, FS = freely soluble, S = soluble, PS = sparingly soluble, SS = slightly soluble, VSS = very slightly soluble and I = insoluble 3. SCREENING TECHNIQUE 3.1. COLOR TESTS REAGENT Marquis Sodium Nitroprusside Chen s Janovsky COLOR PRODUCED No reaction Slight ppt. of blue flecks or blue ring formed Slow forming yellow-orange Brownish red 3.2. GAS CHROMATOGRAPHY Method MCAT-GCS1 Instrument: Gas chromatograph operated in split mode with FID Column: 5% phenyl/95% methyl silicone 10 m x 5 mm x 5 µm Carrier gas: Helium at 1.0 ml/min Temperatures: Injector: 275 C Detector: 280 C Oven program: 1) 100 C initial temperature 2) Ramp to 295 C at 35 C/min 3) Hold final temperature for 6.43 min Injection Parameters: Split Ratio = 100:1, 1 µl injected Samples are to be dissolved in appropriate solvent and filtered. COMPOUND RRT COMPOUND RRT pseudoephedrine 0.14 guaifenesin 1.11 tridecane 2 acetaminophen 1.18

methamphetamine 0.55 phenacetin 1.23 MDMA 0.69 dimethyl sulfone 1.33 amphetamine 0.74 caffeine 1.73 methcathinone 1.00 (3.07 min) dextromethorphan 2.67 3.3. CAPILLARY ELECTROPHORESIS Method MCAT-CES1 Buffer Preparation: Tris-phosphate buffer, ph 2.4 - Prepare by adding one drop H 3 PO 4 per 50 ml of 25 mm Tris(hydroxymethyl)aminomethane HCl buffer Injection Solvent: 9:1 H 2 0:Tris-phosphate buffer Standard Solution Preparation: Accurately weigh and prepare a standard solution of l-methcathinone, d-methcathinone, l-pseudoephedrine, d- ephedrine, l-ephedrine, d-pseudoephedrine, l-methamphetamine and d-methamphetamine using approximately 1.0 mg of racemic mixture or 0.5 mg of an individual enantiomer in 10 ml of injection solvent. Sample Preparation: Accurately weigh an amount of sample and dilute with injection solvent to an approximate concentration of 0.05 mg/ml. Mode: Column: Run Buffer: Detector: Voltage: Free zone 82 cm (60 cm effective length) x 50 µm fused silica capillary 1.2% MeOH, 98.8% 1mM -cyclodextrin-sulfobutylether (IV) [ -CD- SBE(IV)] in 25 mm Tris-phosphate buffer, ph 2.4 UV, 210 nm 30 kv Temperature: 30 C Injection: Run Time: Rinse Time: 0.5 s hydrodynamic 16 min 2 min

COMPOUND RMT COMPOUND RMT l-pseudoephedrine 0.16 d-methcathinone 1.00 (13 min) l-methcathinone 0.43 d-pseudoephedrine 1.27 d-ephedrine 0.70 l-methamphetamine 2.59 l-ephedrine 0.93 d-methamphetamine 3.27 4. EXTRACTION TECHNIQUES Because Methcathinone is sensitive to strong base, it is preferred that saturated sodium carbonate (ph 11) be used to basify aqueous mixtures prior to extraction. Chloroform and methylene chloride are suitable extraction solvents. Shaking the basified aqueous solution with one of these solvents will transfer the methcathinone as the free base into the organic solvent. The solvent should then be passed through a layer of anhydrous sodium sulfate to remove any residual basic aqueous phase. Addition of 2-propanol or ethanol:hydrochloric acid mixture (4:1) to the extracted base, and subsequent solvent evaporation with a steam bath, is suitable to provide the hydrochloride salt. 5. QUANTITATIVE PROCEDURE 5.1. GAS CHROMATOGRAPHY Method MCAT-GCQ Internal Standard Solution (ISS): 1.00 mg/ml Tetradecane in methylene chloride. Standard Solution Preparation: Prepare a standard solution of Methcathinone HCl between 0.4 and 4.56 mg/ml with ISS as solvent. Sample Preparation: Accurately weigh an amount of sample into an appropriately sized volumetric flask so the final concentration of Methcathinone HCl is approximately equivalent to that of the standard solution. Dilute to volume with ISS. Instrument: Column: Carrier gas: Gas chromatograph operated in split mode with FID HP-1 or equivalent, 30 m x 5 mm x 5 µm film thickness Hydrogen at 2.8 ml/min Temperatures: Injector: 265 C Detector: 275 C Oven: 130 C Isothermal for 5 min

Injection Parameters: Typical Retention Time: Linear Range: Split Ratio = 50:1, 1 µl injected 2.712 min 0.40-4.56 mg/ml Repeatability: %RSD less than 4% Correlation Coefficient: 0.9997 Accuracy: %Error less than 5% COMPOUND RRT methamphetamine 0.629 methcathinone 1.00 pseudoephedrine 1.158 tetradecane 1.421 The adulterants guaifenesin, diphenhydramine, dextromethorphan and chlorpheniramine had retention times greater than 5 min. 6. QUALITATIVE DATA 6.1. INFRARED SPECTROSCOPY (FT-IR) Both sample and standard should be subjected to the same procedures, using either KBr pellet or ATR accessory. 6.2. NUCLEAR MAGNETIC RESONANCE (NMR) A solution of approximately 10 to 20 mg sample to 1 ml deuterated solvent is an acceptable concentration for use on the NMR instrument. 6.3. FT-RAMAN SPECTROPHOTOMETRY (FT-RAMAN) No sample preparation is needed unless two or more active substances are in a sample. 6.4. GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) The same parameters from separation method MCAT-GCS1 can be utilized on a GC/MS system with the MS detector temperature at 280 C

See spectra on the following pages for FT-IR, NMR, FT-Raman, and MS. 7. REFERENCES Clarke, E.G.C. ed., Isolation and Identification of Drugs, 2nd Edition, The Pharmaceutical Press, 1986. Dal Cason, T., The Identification of Cathinone and Methcathinone, Microgram, December 1992, pp. 10-29 Drug Enforcement Administration Basic Training for Forensic Drug Chemists Lurie, I., et al., Chiral Resolution of Cationic Drugs of Forensic Interest by Capillary Electrophoresis with Mixtures of Neutral and Anionic Cyclodextrins, Analytical Chemistry, Vol. 66, No. 22, Nov. 15, 1994, pp. 4019-26. Moffat, A. C., Sr. ed., Clarke's Isolation and Identification of Drugs, The Pharmaceutical Press, Second Edition, 1996. O Neil, M. ed., The Merck Index, 13 th Edition, Merck and Co., Inc., 2001, p. 1067. 8. ADDITIONAL RESOURCES Wikipedia

15 51.08 76 3.29 14 01.27 70 3.68 10 67.74 13 71.61 16 82.97 14 46.89 10 23.81 %Transmittance 30 58.22 12 35.23 96 1.47 29 74.27 16 91.62 27 08.62 70 0.19 24 54.76 14 69.31 12 44.90 97 5.99 %Transmittance 15 97.20 13 60.72 FTIR: Methcathinone hydrochloride, KBr pellet 16 Scans, resolution 4.0, 4.0 mg/100 mg 50 45 40 35 30 25 20 15 10 3000 2000 1500 1000 500 Wavenumbers (cm-1) 105 FTIR: Methcathinone base, KBr pellet 16 Scans, resolution 4.0, 4.0 mg/100 mg 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 15 95.41 16 37.06 20 3000 2000 1500 1000 500 Wavenumbers (cm-1)

76 1.58 71 9.54 69 9.05 67 9 16 38.14 60 8.68 78 9.01 %Transmittance 15 96.88 13 67.52 10 00.95 53 8.85 12 33.94 11 22.50 16 81.80 15 58.61 14 46.13 96 0.17 12 01.74 10 66.00 29 72.18 30 59.10 69 8.58 54 1.79 53 2.42 %Transmittance 52 8.14 16 88.97 97 4.97 12 43.85 65 7.93 90 0.36 26 98.86 FTIR (ATR 1-bounce): Methcathinone hydrochloride 16 Scans, resolution 4.0 96 94 92 90 88 86 84 82 80 78 76 74 72 3000 2000 1500 1000 Wavenumbers (cm-1) 100 FTIR (ATR 1-bounce): Methcathinone base 16 Scans, resolution 4.0 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 3000 2000 1500 1000 Wavenumbers (cm-1)

Normalized Intensity Normalized... Normalized Int... Normalized Intensity Normalized Inten... Normalized Int... Nuclear Magnetic Resonance (proton): Methcathinone HCl 10 mg/ml in CD 3 OD 400 MHz 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.15 0.10 0.05 8.00 7.75 0.15 0.10 0.05 5.1 5.0 4.9 4.8 No. (ppm) 1 1.57 2 1.59 3 2.78 4 3.30 5 3.30 6 3.31 7 4.87 8 5.11 9 5.13 10 7.58 11 7.60 12 7.62 13 7.72 14 7.74 15 8.05 16 8.05 17 8.07 18 8.07 0.1 8.5 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 Nuclear Magnetic Resonance (carbon): Methcathinone HCl 15 mg/ml in CD 3 OD 100 MHz 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.1 129.5 128.5 1.00 0.75 0.50 5 49 48 47 46 No. (ppm) 1 14.98 2 30.51 3 47.17 4 47.38 5 47.59 6 47.81 7 48.02 8 48.23 9 48.45 10 59.46 11 128.79 12 129.18 13 133.02 14 134.85 15 195.89 0.3 0.1 0 220 200 180 160 140 120 100 80 60 40 20 0

Normalized Intensity Normalized Inte... Normalized Intensity Normalized Intensity Nuclear Magnetic Resonance (proton): Methcathinone HCl 14 mg/ml in CDCl 3 400 MHz 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.50 5 8.00 7.75 7.50 7.25 No. (ppm) 1 1.76 2 1.77 3 2.85 4 2.86 5 2.88 6 5.05 7 5.05 8 5.07 9 7.26 10 7.47 11 7.48 12 7.50 13 7.60 14 7.62 15 7.64 16 7.92 17 7.93 18 7.93 19 7.95 0.1 8.5 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 Nuclear Magnetic Resonance (carbon): Methcathinone HCl 15 mg/ml in CDCl 3 100 MHz 1.0 0.9 0.8 0.7 0.6 1.00 0.75 0.50 5 No. (ppm) 1 16.32 2 31.82 3 59.66 4 76.93 5 77.24 6 77.56 7 129.12 8 129.38 9 133.18 10 134.89 11 195.22 0.5 0.4 135.0 132.5 130.0 0.3 0.1 0 220 200 180 160 140 120 100 80 60 40 20 0-20

Normalized Intensity Normalized Intensity Normalized Intensity Nuclear Magnetic Resonance (proton): Methcathinone base 10 mg/ml in CD 3 OD 400 MHz 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.1 0.10 0.05 0 8.00 7.75 7.50 7.25 No. (ppm) 1 1.28 2 1.30 3 2.23 4 2.35 5 2.67 6 3.30 7 3.30 8 3.30 9 3.31 10 3.31 11 3.58 12 3.75 13 4.88 14 7.53 15 8.00 16 8.00 17 8.02 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.45 0.40 0.35 0.30 5 0 0.15 0.10 0.05 Nuclear Magnetic Resonance (proton): Methcathinone base 20 mg/ml in CDCl 3 400 MHz No. (ppm) 1 2.07 2 2.11 3 2.22 4 2.24 5 2.39 6 2.79 7 2.97 8 3.02 9 3.57 10 3.67 11 3.78 12 3.89 13 7.26 14 7.32 15 7.33 16 7.34 17 7.35 18 7.44 19 7.46 20 7.51 21 7.52 22 7.52 23 7.52 24 7.53 25 7.53 26 7.55 27 8.05 28 8.06 29 8.07 0 8.0 7.5 7.0 6.5 6.0 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5

15 41.14 13 69.18 11 75.73 61 6.91 29 29.71 14 48.50 Raman intensity 30 62.89 15 97.75 16 48 10 28.67 10 00.75 Raman intensity 29 62.67 16 89.09 30 65.19 15 96.36 10 00.36 11 FT RAMAN: Methcathinone HCl 64 Scans, resolution 8.0 10 9 8 7 6 5 4 3 2 1 0 3000 2000 1500 1000 500 Raman shift (cm-1) FT-RAMAN: Methcathinone Base 64 Scans, resolution 8.0 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.0 3000 2000 1500 1000 500 Raman shift (cm-1)

MS: Methcathinone HCl in Chloroform