Q. sample preparation for FTIR & How to sample introduce in the system?

Similar documents
IR Sample Preparation: A Practical Guide

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique

Installation and User Guide. HATR Horizontal ATR Accessory

Instrument Configuration for Powder Diffraction

MIRacle TM Single Reflection Horizontal ATR Accessory

Tissue & Cell Genomic DNA Purification Kit. Cat. #:DP021/ DP Size:50/150 reactions Store at RT For research use only

Abcite 585 EF. Technical Data and Application Guide. Product description. Typical applications. Product range. Product certifications.

Qswitched lasers are gaining more interest because of their ability for various applications in remote sensing, environmental monitoring, micro

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

Kit Components Product # (50 samples) Wash Solution A Elution Buffer B

E.Z.N.A. Tissue RNA Kit. R preps R preps

Installation and User Guide. HATR Flow Cell, Jacketed Flow Cell, Heated Flow Cell for Horizontal ATR Accessories

Spectrophotometry of DNA and RNA

EZ-10 SPIN COLUMN GENOMIC DNA MINIPREPS KIT HANDBOOK

Supporting Information. Low temperature synthesis of silicon carbide nanomaterials using

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Spectroscopy Fiber Optic Probes for In-line Analytical Analysis

Short Notes. phys. stat. sol. (b)-

2. Crystallization. A. Background

Measuring Manganese Concentration Using Spectrophotometry

Cells and Tissue DNA Isolation Kit (Magnetic Bead System) 50 Preps Product # 59100

PowerSoil DNA Isolation Kit

MAKING SOLID SOLUTIONS WITH ALKALI HALIDES (AND BREAKING THEM) John B. Brady

Supplementary Material (ESI) for Chemical Communications. Solid-state single-crystal-to-single-crystal transformation from a 2D

Note: for laboratory research use only. RNA High-purity Total RNA Rapid Extraction Kit (Spin-column) Signalway Biotechnology

E.Z.N.A. Plant RNA Kit. R preps R preps R preps

Standard Optics Information

Physical structure of matter. Monochromatization of molybdenum X-rays X-ray Physics. What you need:

Polyvidone Polyvinylpyrrolidone H 2 C H C N

MI USA. 1, Eggenstein-Leopoldshafen, Germany. Engineering, University of Michigan, Ann Arbor, MI USA

Electron Microscopy (EM) Grid

SECTION DECORATIVE METAL AND GLASS RAILING

QIAGEN Supplementary Protocol: Isolation of genomic DNA from tissue using the QIAGEN-tip Storage of tissue samples.

Transmission Electron Microscopy (TEM) Prof.Dr.Figen KAYA

ADVANCED AP PLACEMENT CHEMISTRY. Activity Series. Introduction. Objective. Chemicals and Equipment

Guide to Measuring Water in Oil

Recrystallization with a Single Solvent

foodproof Sample Preparation Kit III

Growth and Characterization of NLO Single Crystal: BIS L- Alanine Potassium Chloride (BIS-LAKCL)

Application Guide AC- 130 Metal Alloy Surface Preparation For Bonding

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar

Scotch-Weld Metal Bonder Acrylic Adhesive DP8407NS Gray

ESTIMATION OF IMPURITIES IN LIQUID CHLORINE By INFRARED ABSORPTION SPECTROPHOTONIETRYl

Chapter 4: Recrystallization & Melting Point

16.2 Scanning Infrared Spectrometers

Characterization of Silica from Sodium Hydroxide Treated Rice Husk

E.Z.N.A. Total RNA Kit II. R preps R preps R preps

LIBRARY SCREENING. For background reading, read Maniatis or Current Protocols.

Supplemental Information: Polyethylene bio-degradation by caterpillars of the wax moth Galleria mellonella

Thermo Scientific Nicolet is10 FT-IR Spectrometer. Complete infrared spectroscopy system. for routine analytical needs

Standard Specification for Chemical Admixtures for Concrete 1

Industrial flue gas probes. Instruction manual

Product Catalogue 2014

Experiment 3: The Chromatography of Organic Compounds

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

GenElute Plant Genomic DNA Miniprep Kit

(Spin Column) For purification of DNA and RNA from formalin-fixed, paraffin-embedded tissue sections. Instruction for Use

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry 2009

VIBRATIONAL STUDIES OF Na 2 SO 4, K 2 SO 4, NaHSO 4 AND KHSO 4 CRYSTALS

Standard Test Method for Adhesion Between Steel Tire Cords and Rubber 1

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

Gas Chromatography Assignment Chem 543/443

Label Tape FAQs and Technical Information Pertaining to Brother Label Printers PT-9700PC and PT-9800PCN

THE EFFECT OF SOL-GEL TECHNIQUE ON THE ALUMINIUM SiCp COMPOSITE

Multi-step and multi-component organometallic synthesis in one pot using orthogonal mechanochemical reactions

3 Scotch-Weld TM Flexible Epoxy Adhesive LSB90

EZ-DNA. Instructions for Use. Genomic DNA Isolation Reagent. Product Description. Kit Reagent. Reagent Required But Not Supplied.

Fast Preparative Column Liquid Chromatography (PCLC)

2. Name the key ideas of the Particle Model of Matter

EXPERIMENT GENOMIC DNA ANALYSIS

Fabrication of Magnesium Oxide Ceramics with Density Close to Theoretical Using Nanopowders

32 Sq ft Kit Technical Data Sheet

Generation Response. (Supporting Information: 14 pages)

Product # 24700, 24750

OPERATING INSTRUCTIONS

Capillary GC Troubleshooting: a Practical Approach

LIFluor EnhanCE. for use with dsdna 1000 and dsdna 20,000 Kits

for New Energy Materials and Devices; Beijing National Laboratory for Condense Matter Physics,

1. Elemental mercury is a shiny, silver-colored, dense liquid that flows easily. Are these characteristics of mercury physical or chemical properties?

Endex Foam Extrusion General Information Guide

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

SPECIMEN PREPARATION FOR ELECTRON MICROSCOPY

Experiment 2: The Chromatography of Organic Compounds

HOW TO BUILD A PIZZA BOX SOLAR OVEN

Matrix-free synthesis of spin crossover micro-rods showing large hysteresis loop. centered at room temperature

Light and the Aquatic Ecosystem

Skills in Science. Lab equipment. (Always draw 2D) Drawings below are NOT to scale. Beaker - A general purpose container with a pouring lip.

Module 8: Composite Testing Lecture 36: Quality Assessment and Physical Properties. Introduction. The Lecture Contains

EASY BREATHE PORCERAX II INTRODUCING WITH PORCERAX II PLASTIC INJECTION MOLDING OTHERS... Pre-Hardened (35/38 HRC) Sintered, Porous Metal.

INSTRUCTION FOR BONDING TECHNOLOGY Fibermarine / Fibermarine HighLine

Laboratory protocol for manual purification of DNA from whole sample

2023 Reduction of D-(+)-camphor with lithium aluminium hydride to an isomeric mixture of (+)-borneol and ( )-isoborneol

Experiment 4 MELTING POINTS OF ORGANIC COMPOUNDS 1

Preparative, Pilot & Process Columns

Electricity and Chemistry

CRESTONE STRAIGHT FIRE PIT SKU:

A SOLVENT-FREE COMPOSITE SOLID ELECTROLYTES OF Li 2 CO 3 Al 2 O 3 SYSTEM PREPARED VIA WATER BASED SOL GEL METHOD

Post-Removal Examination of GTF Cathode #3 Robert Kirby and Frane Marcelja Physical Electronics Group SLAC

Condensed Matter II: Particle Size Broadening

Travaux Pratiques de Matériaux de Construction. Etude de Matériaux Cimentaires par Diffraction des Rayons X sur Poudre

Transcription:

Q. sample preparation for FTIR & How to sample introduce in the system? FTIR SAMPLE PREPARATION FTIR sample cell designed according to nature of a sample. Sample may be liquid/solid/gaseous. Sample preparation for Solid sample. Sample is mixed with KBr powder, Blend is compressed under 10 ton pressure to a small tablet/disc (diameter=1 cm, thickness=1-3 mm). Disc is placed in a disc holder & measured. Best method for solid sample b coz (over Nujol Mull process) KBr is 100% transparent to IR radiation & shows no peak. So, peak will be obtained only because of sample. Method is used for qualitative analysis. It can t be used for quantitative analysis, because solid dispersion are not 100% transparent. Solution preparation for liquid analysis... Sample is dissolved & diluted in a non-aqueous solvent to get a clear solution is placed in cell & measured CCl₄ & CS₂ as solvent because not absorbing radiation range. Nujol-Mull process Sample is triturated with liquid paraffin to get paste, which is placed between kbr discs & measured process,( liquid paraffin(mulling agent) which should be free from traces of H₂O). Bonds of liquid paraffin have their own absorption, by which more complex spectrum achieved. For liquid Sample.. Concentration should be in range mg/ml KBr cells.(gap thickness 0.01 to 1 mm) Solution is prepared in non-aqueous solvent like CS₂ & CCl₄ etc Liquids are measured as such or after suitable dilution. But, solvent also shows absorbance peaks which is difficult to separate. Thus solvent should be so selected that it shows in overlapping spectrum for measurement of liquid, Sample cell made of NaCl should be used.

Gaseous Sample Measured directly after purification Gaseous Sample is made free from CO₂ & H₂O. That s why, For CO₂--KOH is used & for H₂O--- CaCl₂ used. Gaseous cell which pressured & certain volume (5-50 mm thickness) FT-IR sample preparation 1. LIQUIDS: Place a small drop of the compound on one of the KBr plates. Place the second plate on top and make a quarter turn to obtain a nice even film. Place the plates into the sample holder and run a spectrum. If the sample is too concentrated, separate the plates and wipe one side clean before putting them back together. The KBr plates must be thoroughly cleaned after this procedure to prevent contamination of future samples. Wipe the windows with a tissue, then wash several times with methylene chloride (or another solvent that will take off you sample), then ethanol. Use the polishing kit in the lab to polish the window surface. Wear gloves to prevent fogging. The cleaned surface should be clear and free from scratches. 2. SOLIDS (in solution): Prepare a concentrated solution of your compound in a suitable solvent (e.g. CH2Cl2). Attention: Remember that all solvents containing water will either dissolve the KBr plates or make them fog up. The broad water band might also mask important bands of your compound. There are several ways to do this depending how much material you have at hand: either you place a small amount (2-5 mg) of your compound directly on the plates and add one drop of solvent, or you dissolve it in a small test tube first and transfer this solution with a pipet onto the IR plates. Reminder: Obtain a spectrum of solvent as well, or run the pure solvent as a baseline to automatically subtract it. The KBr plates must be thoroughly cleaned after this procedure to prevent contamination of future samples. Wipe the windows with a tissue, then wash several times with your solvent, then ethanol. Use the polishing kit in the lab to polish the window surface. Wear gloves to prevent fogging. The cleaned surface should be clear and free from scratches.

3. SOLIDS (as Nujol mulls) Alternative methods to obtain IR spectra of solids are Nujol (mineral oil) mulls between KBr plates. Remember that Nujol by itself shows a characteristic spectrum! Good results are obtained by this method only if the average particle size of the solid is somewhat less than the wavelength of light the particles are to transmit. Samples should therefore be ground in a mortar to reduce the average particle size to 1 to 2 microns. About 5 to 10 mg of finely ground sample are then placed onto the face of a KBr plate, a small drop of mineral oil is added and the second window is placed on top. With a gentle circular and back-and-forth rubbing motion of the two windows, evenly distribute the mixture between the plates. The mixture should appear slightly translucent, with no bubbles, when properly prepared. Place the sandwiched plates in the spectrometer and obtain a spectrum. Ideally, the strongest band should have a transmission ob 0 to 10% and should not be totally absorbing for more than 20 cm -1. Attention: If the bands are distorted (show fronting or tailing) the particle size is too great and some radiation incident on the mull has been scattered out of the sample beam (Christiansen scattering). If a better spectrum is required reduce the particle size further. The KBr plates must be thoroughly cleaned after this procedure to prevent contamination of future samples. Wipe the windows with a tissue, then wash several times with methylene chloride, then ethanol. Use the polishing kit in the lab to polish the window surface. Wear gloves to prevent fogging. The cleaned surface should be clear and free from scratches. 4. KBr pellets/disks (for solid samples) In order to prepare a KBr pellet, follow the procedure given below: Sample/KBr ratio The concentration of the sample in KBr should be in the range of 0.2% to 1%. The pellet is much thicker than a liquid film, hence a lower concentration in the sample is required (Beer's Law). Too high a concentration usually causes difficulties obtaining clear pellets.

The IR beam is absorbed completely, or scattered from the sample which results in very noisy spectra. Sample preparation Although a homogeneous mixture will give the best results, excessive grinding of the potassium bromide is not required. The finely powdered potassium bromide will absorb more humidity (it is hygroscopic) from the air and therefore lead to an increased background in certain ranges. Make sure to work fast. Transfer some KBr out of the oven (ATTENTION: the oven is at 100 o C - you can easily burn yourself!) into a mortar. Add about 1 to 2 % of your sample, mix and grind to a fine powder. For very hard samples, add the sample first, grind, add KBr and then grind again. The sample must be very finely ground as in the Nujol mulling technique to reduce scattering losses and absorption band distortions. Take two stainless steel disks out of the desiccator. Place a piece of the precut cardboard (in the tin can next to the oven) on top of one disk and fill the cutout hole with the finely ground mixture. Put the second stainless steel disk on top and transfer the sandwich onto the pistil in the hydraulic press. With a pumping movement, move the hydraulic pump handle downward. The pistil will start to move upward until it reaches the top of the pump chamber. Then, move the pump handle upwards and pump until the pressure reaches 20,000 prf. Leave for a few seconds and with the small lever on the left side, release the pressure (hold until the sample and pistil are all the way down). Remove the disks and pull apart. Remove the film, which should be homogenous and transparent in appearance. Insert into the IR sample holder and attach with scotch tape. Run the spectrum. After use, the mortar and pistil should be cleaned with acetone and double distilled water, and be put back on top of the oven for drying. Reasons for Cloudy Disks 1. KBr mixture not ground enough 2. Sample was not dry 3. Sample: KBr ratio high 4. Pellet too thick 5. Bolts not tightened sufficiently. 6. Sample has low m.p.

In order to obtain any meaningful information from your IR spectrum, you need to have a decent spectrum with sharp peaks, i.e., with 'good' intensity and good resolution. Ideally, the largest peak, which is caused by your compound, should have an intensity of 2-5%T. Most detectors only respond linearly over a certain range (typically one magnitude). Keep in mind that a transmission of 5% is equivalent to an absorption A=1.3, which is the upper limit for most detectors. If you observe a higher intensity, all your impurities will seem to be more significant than they really are. The peaks with the high intensity will be cut off. Therefore, it is very important to prepare the sample properly. Q. KBr process KBr Pellet procedure for solid samples Take about 1/8 of the solid sample on a microspatula and about 0.25-0.50 teaspoons of KBr. Mix thoroughly in a mortar while grinding with the pestle. If the sample is in large crystals, grind the Sample separately before adding KBr. Place just enough spl. to cover bottom in pellet die. Place in press and press at 5000-10000 psi. Check pellet press brochure for details. Carefully remove the pressed sample from die and place in the FTIR sample holder. The pressed disc should be nearly clear if properly made. If it is translucent, Regrind and repress. Q. Analysis of Rubber (FTIR Rubber) Qualitative Analysis of Rubber (FTIR ) One method of qualifying rubber is measuring the attenuated total reflectance (ATR) using a fast and simple infrared spectrophotometer (FTIR). Using the ATR method allows obtaining an infrared spectrum easily by pressing the rubber tightly against a prism surface, which allows qualitative analysis of the rubber. In addition, Energy Dispersive X-ray (EDX) fluorescence spectrometers can be used to easily, quickly, and nondestructively analyze the constituent elements. In this example, FTIR and EDX systems are used to qualify a rubber diaphragm sample. Analysis Using the FTIR ATR Method The sample was measured using the Ge prism on the PIKE MIRacle single-reflection ATR accessory. Baseline correction and a spectrum search were performed for the spectrum obtained from measurements. The

spectra below are for nitrile rubber containing PVC (polyvinyl chloride), where the lower spectrum is from measurement results and the upper spectrum is from the database search. (The presence of nitrile rubber can be confirmed from the peaks for the nitrile group near 2200 cm-1 and the out-of-plane bending vibration from the =C-H bonds near 966 cm-1, whereas PVC can be confirmed from the peak near 600 cm-1, due to C-Cl stretching vibrations. However, since the spectrum from measurement results does not show measurements below 700 cm-1, due to absorption by the Ge prism itself, it does not allow confirming the C-Cl peak.) FTIR Data Measurement Peaks (After Correction) and Library Search Spectrum