LARGE QUANTITY GENERATOR (LQG) OF HAZARDOUS WASTE

Similar documents
Small Quantity Generator (SQG) of Hazardous Waste

Hazardous Waste Small Quantity Generator Checklist

COMPLIANCE ASSISTANCE VISIT REPORT

Hazardous Waste Generator Improvements Rule

TENNESSEE DEPARTMENT OF TRANSPORTATION DISPOSAL CORE PLAN FOR THE MANAGEMENT OF HAZARDOUS WASTES, UNIVERSAL WASTES, AND USED OIL

Hazardous Waste Management at Remote (SQG) Sites

Hazardous Waste Generator Improvements Final Rule. US EPA Office of Resource Conservation and Recovery

Chapter VII HAZARDOUS WASTE REGULATION. Hazardous wastes are governed by the regulatory program established by the federal

PART 273 STANDARDS FOR UNIVERSAL WASTE MANAGEMENT. Subpart A General. Subpart G Petitions to Include Other Wastes Under 40 CFR Part 273

2018 Hazardous Waste Compliance Calendar

SUSTAINABLE PRINTING WORKBOOK IOWA. By Graphic Arts Training & Consulting Group (GATC) Iowa Waste Reduction Center (IWRC)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Yale University Environmental Health and Safety

HAZARDOUS AND SOLID WASTE ENVIRONMENTAL REQUIREMENTS CHECKLIST FOR CONSTRUCTION PROJECTS

PART 262 STANDARDS APPLICA- BLE TO GENERATORS OF HAZ- ARDOUS WASTE. Subpart A General. Subpart A General. Subpart B The Manifest

TAMPA BAY WATER Supplying Water To The Region

APPENDIX A STATEMENT OF WORK SCRAP RUBBER/TIRE REMOVAL AND RECYCLING SERVICES

SITE SPECIFIC SPILL PLAN For use of this form, see the Installation Spill Contingency Plan; the proponent is DPW-ENRD

Hazardous Material Release Response Plan (HMRRP) and Hazardous Waste Generator Compliance Guidance

Hazard Communication Program. Program originated: 07/2002 Last Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

SECTION 10. WASTE TIRE FACILITIES and WASTE TIRE HAULERS Standards for Tire Retailers, Wholesalers and Fleet Service Facilities

Environmental Management Procedure (EMP)

NEBRASKA DEPARTMENT OF ENVIRONMENTAL QUALITY

Photographic Processing Facility Sector Control Policy

Abu Dhabi Occupational Safety and Health System Framework (OSHAD-SF) Code of Practice

Managing Hazardous Chemical Waste

Hazardous Waste Removal and Disposal

Perchlorate BMP Regulations R TITLE 22 EMERGENCY REGULATIONS Perchlorate Best Management Practices DEPARTMENT REFERENCE NUMBER: R

EMPLOYEE R-T-K, EMPLOYEE TRAINING, AND TRAINING RECORDS

CHAPTER 29 - HAZARDOUS WASTE MANAGEMENT

Manifest Information. Types of Manifests. Universal Hazardous Waste Manifest

Common Compliance Issues and Associated Fines by Meghan Sunyar, Technical Services Representative

ENVIRONMENTAL COMPLIANCE AUDIT CHECKLIST

HAZARDOUS WASTE MANAGEMENT: WHAT S NEW?

(a) LLW for processing and expect its return (i.e., for storage under their license) prior to disposal at a licensed land disposal facility;

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATION

CHAPTER 7: HAZARDOUS AND RECYCLED WASTE

York College. Regulated Wastes Awareness Training

INJURY AND ILLNESS PREVENTION PROGRAM. Adopted June 25, 1991 by Board Resolution 91-95

Supply Chain Management for Composite Wood Products

UNIVERSAL WASTE CHECKLIST

Dangerous Goods (Storage and Handling) Regulations 2000 and Code of Practice

Avanco International, Inc. TRANSPORTATION PLAN FOR THE TRANSFER OF CLASSIFIED MATERIAL

Safety Training *Print or save this presentation if you want, by clicking here to load a.pdf of this handout.

(1) Adequately wet asbestos-containing waste material as follows by doing all of the following:

TECHNICAL SPECIFICATIONS FOR LIQUID AMMONIUM SULFATE

EASTERN MICHIGAN U N I V E R S I T Y SECURITY OF HAZARDOUS MATERIALS IN TRANSPORT

CONTINUITY OF OPERATIONS (COOP) WORKSHEETS

Louisiana Department of Environmental Quality 2014 HAZARDOUS WASTE REPORT INSTRUCTIONS AND FORMS

RCRA SUBTITLE C SITE IDENTIFICATION FORM

Pesticides and the RCRA Resource Conservation and Recovery Act

Security Procedure - Participation / Certification in Foreign Customs Administrations Supply Chain Security Programs

Why is a Hazardous Materials Spill/Industrial Accident a Threat to the City of Nacogdoches?...8-2

Chapter 7 Transportation of Radioactive Material

Hazardous Waste Annual Report

UNIVERSITY OF TOLEDO

Environmental Standard Operating Procedure Originating Office: Natural Resources and Environmental Affairs Office

CORPORATE PROCUREMENT UNIT SITE & SECURITY PROCEDURES BOSTON SPA VERSION 7 APR09

COUNTY OF SANTA BARBARA OFFICE OF THE AGRICULTURAL COMMISSIONER SANTA BARBARA SANTA MARIA LOMPOC SOLVANG CARPINTERIA

Whiting Metals, LLC 2230 Indianapolis Boulevard Hammond, Indiana 46394

INDUSTRIALIZED HOUSING AND BUILDINGS Administrative Rules of the Texas Department of Licensing and Regulation 16 Texas Administrative Code, Chapter 70

Pipeline & Hazardous Materials Safety Administration (PHMSA)

NORTH AMERICAN STANDARD HAZARDOUS MATERIALS / TRANSPORTATION OF DANGEROUS GOODS INSPECTION PROCEDURE

HAZARDOUS MATERIALS BUSINESS PLAN (HMBP)

BURLINGTON BOARD OF HEALTH

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT CEMENT CERTIFICATION. April 18, 2008

The Resource Conservation & Recovery Act (RCRA) Compliance & Enforcement

Developing an Environmental Compliance Plan

Check the box below if you are operating mobile tire processing equipment [APC&EC Reg ]: Mobile Tire Processing Equipment

RCRA SUBTITLE C SITE IDENTIFICATION FORM

New Jersey Department of Environmental Protection. Transportation Oversight Unit

BOWDOIN COLLEGE BIOMEDICAL WASTE MANAGEMENT PLAN

University Health Services Health and Safety REGULATIONS FOR AUTOCLAVE USE, MAINTENANCE AND RECORDKEEPING

Sustainable Materials Management and The Definition of Solid Waste Final Rule

Current Practice of Recycling and Treatment of Hazardous Wastes in the Philippines

Division of Solid Waste Management Nashville, Tennessee HAZARDOUS WASTE MANAGEMENT PERMIT

INTERNATIONAL CYANIDE MANAGEMENT INSTITUTE Cyanide Transportation Verification Protocol

The boxes of compliance

Dangerous Goods Safety Management Regulation 2001

Case 1:17-cr DN Document 1 Filed 07/12/17 Page 1 of At all times relevant to this Indictment, Defendant Stone Castle, L.L.C.

Occupational Safety & Health Act (OSH Act) New Hire & Annual Staff Training

TEXAS COMMISSION ON ENVIRONMENTAL QUALITY

CITY OF NEW LONDON HAZARD COMMUNICATION PROGRAM

TIMBERLAKE IMPROVEMENT DISTRICT Jones Rd, Suite 120, Houston, Texas Phone Number (281)

Hazard Communication Program. University of San Diego

Environmental Requirement Review Checklist and Certification

National Road Traffic Act 93 of 96 and its amendments

LOUISIANA URBAN STORMWATER COALITION. EXECUTING A SWPPP DURING CONSTRUCTION Presented by: Diane T. Baum

CLASS I AND II ABATEMENT PROJECT SUBMITTALS

Waste Prevention and Management Environmental Laboratory Waste Management Manual

BRIGHAM YOUNG UNIVERSITY IDAHO ENVIRONMENTAL, HEALTH & SAFETY SAFETY DEPARTMENT ACCIDENTAL SPILL PREVENTION PLAN EH-009-R03

Environmental Management Chapter ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT LAND DIVISION - SOLID WASTE PROGRAM ADMINISTRATIVE CODE

Spotlight on Animal Health Business Operations: A Legal Update Husch Blackwell LLP. March 5, 2015

Community Right-to-Know Program (CRTK)

CHAPTER 1: ENVIRONMENTAL AND EMERGENCY RESPONSE PLANNING

DRI Procedure for Moving/Transporting Chemicals 1

UNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES

Solvent Contaminated Wipes Questions

Environmental Conditions Laboratories (for commercial use) Group

Michigan Environmental Compliance Conference

Transcription:

LARGE QUANTITY GENERATOR (LQG) OF HAZARDOUS WASTE Iowa Waste Reduction Center / University of Northern Iowa 319-273-8905 or 1-800-422-3109 40 CFR 262 August 2015 Do these regulations apply to my operation? If your facility generates more than 2,200 pounds of hazardous waste in any calendar month or stores more than 13,200 pounds of hazardous waste on-site at any time. Facilities generating and storing less than these limits are subject to either the Small Quantity Generator (SQG) or Conditionally Exempt Small Quantity Generator (CESQG) regulations. General Requirements All waste generators must, at a minimum: Accurately characterize each facility waste as hazardous or non-hazardous. Maintain an inventory documenting the facility s monthly hazardous waste generation rate and the amount of hazardous waste stored on-site. Manage hazardous wastes in compliance with applicable on- and off-site federal regulations. What are the benefits of proper management of hazardous waste? Hazardous waste regulations were established to minimize human and environmental exposure to hazardous substances. The Environmental Protection Agency (EPA) has written a comprehensive set of regulations that govern the management of hazardous waste from the point of generation to disposal. They also incorporate a record keeping/reporting/tracking system to verify and document that the waste is, in fact, managed appropriately. Finally, compliance with hazardous waste regulations is an enforceable law. Noncompliance can result in fines of up to $37,500 per day for each violation. LQG Regulatory Requirements In addition to the general requirements listed previously, LQGs must also comply with the following: EPA Identification Number LQGs must obtain an EPA Hazardous Waste Generator Identification Number. This number is used to identify the facility and the hazardous waste activities occurring there. It is also required on all waste shipping papers. An ID number is obtained by completing the form enclosed in EPA s "Notification of Hazardous Waste Activity" booklet (EPA Form 8700-12).

Waste Generation, Accumulation, and Storage Hazardous waste storage containers must remain sealed except during the addition or removal of waste. Hazardous waste storage containers must be clearly labeled Hazardous Waste. Up to 55 gallons of hazardous waste may be accumulated at the point of generation and under the supervision of the individual generating the waste for an indefinite period of time. The container must be labeled Satellite Accumulation. When 55 gallons has accumulated, the satellite accumulation container must be moved to a permanent hazardous waste storage area within 3 days and relabeled Hazardous Waste. Hazardous waste containers must be marked with the date they first received waste or the date when moved from the satellite accumulation area to the permanent hazardous waste storage area. The permanent hazardous waste storage area must be inspected weekly for leaking containers and proper container labeling and dating. This is done to assure the containers are sealed and to maintain adequate access to all containers. Weekly inspections should be documented in a logbook that is maintained on-site. Hazardous waste may not be stored on-site for more than 90 days. Preparation for Off-Site Transportation Hazardous waste storage containers must be packaged, labeled, and marked according to the Department of Transportation s (DOT) hazardous materials transport regulations. This includes the following information on each container: HAZARDOUS WASTE - Federal Law Prohibits Improper Disposal. If found, contact the nearest police or public safety authority or the U.S. Environmental Protection Agency. Generator's Name and Address Manifest Document Number Commercially available labels can be used. The generator must assure the hazardous waste transport vehicle is affixed with the appropriate DOT placards. Shipping Papers All shipments of hazardous waste must be accompanied by a Uniform Hazardous Waste Manifest. The manifest is a multiple copy form that must be signed by the generator, transporter, and disposal facility personnel. Each entity should keep its respective copy of the form. The original copy of the manifest must be returned to the generator by the disposal facility within 45 days. Both the generator and original copy of the manifest must be filed on-site and be readily available for inspection for at least three years. For waste subject to Land Ban restrictions, a Land Disposal Restriction Notification (LDR) form must accompany the hazardous waste manifest. The transporter/disposal facility will assist in determining if a LDR is required. If so, a copy must remain on-site and be readily available for inspection for at least three years.

Preparedness and Prevention Hazardous waste storage areas must be maintained and operated to minimize the possibility of fire, explosion, or release of hazardous waste. Hazardous waste storage areas must be equipped with or provide immediate access to the following: o Internal communications or alarm system; o A telephone to summon emergency assistance from local authorities; o Fire extinguisher and control equipment; o Spill control equipment; and o Water to supply hoses or sprinkler systems. All equipment must be tested and maintained to assure proper operation. When hazardous waste is handled, all personnel involved must have immediate access to an internal alarm or emergency communication device. If just one employee is present, he or she must have immediate access to a device capable of summoning external assistance. Aisle space must be maintained to allow for fire protection and spill control in an emergency. The generator must familiarize local police, fire departments, and emergency response teams with the layout of the facility, properties of hazardous waste handled at the facility and associated hazards, places where facility personnel would normally be working, entrances to roads inside the facility, and possible evacuation routes. An example letter to assist in preparing this notification is attached. Where authorities decline to enter into arrangements, documentation of the attempt to make arrangements (e.g., certified letter requesting arrangements) must be kept on file. Contingency Requirements A written Contingency Plan, containing the following items, must be kept on file at the facility: o Emergency procedures used in response to fires, explosions, or release of hazardous waste. o Description of arrangements made with local police, fire department, hospital, and emergency response teams for coordinating emergency service. o Names, addresses, and phone numbers (office and home) of all designated emergency coordinators. o A list of all emergency equipment at the facility, including the location and physical description of the item, and a brief outline of its capabilities. An evacuation plan for facility personnel, describing evacuation signals, routes, and alternative routes. Copies of the Contingency Plan must be submitted to local police, fire departments, hospitals, and emergency response teams that may provide emergency services. The Contingency Plan must be reviewed and amended immediately when significant features, such as regulations, facility characteristics, or emergency equipment, change. At all times, there must be at least one employee available, or on call, with the responsibility for coordinating all emergency response measures (emergency coordinator). The following information must be posted at the telephone closest to the hazardous waste

storage area: o Name and telephone number of emergency coordinator(s); o Location of fire extinguishers, spill control material, and fire alarm; and o Telephone number of the fire department. All employees involved in waste handling and management must be thoroughly familiar with proper waste handling and emergency procedures (Records of training should be kept on file). The emergency coordinator must respond appropriately to emergencies as follows: o Activate internal facility alarms or communication systems. o Notify appropriate state or local agencies. o Identify the character, source, amount, and extent of any hazardous releases. o Notify local authorities if evacuation of local areas is advisable. o Notify the National Response Center (800/424-8802) and the Iowa Department of Natural Resources (515/281-8694) if the release threatens human health or the environment, or is above the reportable quantity (RQ) for the chemical/waste released. o Take measures to ensure that fires, explosions, and releases do not recur or spread. o Provide proper storage and disposal of recovered waste and contaminated materials. Clean and ready emergency equipment prior to resumption of facility operations. The EPA Regional office, state DNR, and local authorities must be notified that all emergency procedures have been completed before operations in the affected area can resume. Within 15 days after an incident, a written report must be submitted to EPA Region VII providing the following information: o Name, address, and telephone number of the owner or operator; o Name, address, and telephone number of the facility; o Date, time, and type of incident; o Name and quantity of materials involved; o Extent of injures; o An assessment of how hazardous it is to human health or the environment; and o Estimated quantity and disposition of recovered material. Training Facility personnel must complete training (classroom or on-the-job) that includes: o Procedures for using, inspecting, repairing, and replacing facility emergency equipment; o Communication or alarm systems; o Response to fires or explosions; o Response to groundwater contamination; and Shutdown of operations. Training must be completed within six months after employment. An annual review of training must be conducted. Training records must be maintained including the following information: o Job title and name of each employee whose position involves management or reasonable contact with hazardous waste;

Record Keeping o Written job description; o Written description of type and amount of introductory and continuing training; and o Records documenting the training has been given. Generator and original copies of hazardous waste disposal manifests must be maintained for at lease three years. Land Disposal Restriction Notification forms must be maintained for five years. Laboratory data documenting hazardous/non-hazardous waste determinations must be kept for three years from the date that the waste was last sent to treatment, storage, or disposal. Documentation of hazardous waste storage area inspections, employee training, emergency agency notification, etc., must be maintained on-site and be readily available for inspection. A Biennial Report must be submitted to the EPA every even-numbered year.

Notification of Large Quantity Waste Generation Activity - Example Letter Date: To: (Specific Individual (i.e., Fire Chief, Police Captain, and Hospital Administrator by name)). From: (Company and contact name) Re: Notification of Large Quantity Waste Generation Activity. Company name generates large quantities (greater than 1,000 kg/month) of hazardous waste, which is accumulated up to 90 days before being collected by an authorized transporter. Wastes generated and stored include type of waste(s). This waste is collected and stored in our location of storage area, which is located at address (see drawing). The maximum amount stored at any one time is less than number gallons. Material Safety Data Sheets for the original materials are enclosed. Fire and health risks from the used material are expected to be similar to that of the original material. This letter is sent in order to fulfill 40 CFR Part 262.34 (a)(1) of the Federal Hazardous Waste Regulations. Sincerely, Authorized Personnel Enclosure Note: Send letter by certified mail so a return receipt can document that the letter was received. The facility drawing should show storage areas, entrances and roads inside the facility and places where personnel are normally working.