Equipment Needs and Maintenance, What is Required in the Wet Chemistry Laboratory for Manual Method Testing

Similar documents
Required Documentation for PA State (Chapter 252) Accreditation

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018

Northern Michigan Operators Spring Seminar. Lab Issues

Index for Labs under Chemical Engineering

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Chapter 8. Gravimetric Analysis

Total Dissolved Solids Dried at 180ºC. Total Volatile Dissolved Solids at 550 C

INTERNATIONAL OIML R 69 RECOMMENDATION. Glass capillary viscometers for the measurement of kinematic viscosity - Verification method

Salinity in Seawater

Gravimetric Analysis: Determination of % Sulfur in Fertilizer

Oxygen Demand, Chemical

Standard Methods for the Examination of Water and Wastewater

Rev Experiment 10

EQUIPMENTS & MATERIALS COMMONLY USED IN A LABORATORY

OKLAHOMA DEPARTMENT OF TRANSPORTATION LABORATORY QUALIFICATION POLICY

VISCOSITY, INHERENT (One Point)

Experiment 1 Determination of ph

5 - Chlorophyll Analysis Lab.

Hach Method Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater

Methods for determination of mercury in LP gas

GRAVIMETRIC DETERMINATION OF SULFATE IN AN UNKNOWN SOLUTION

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Ti-Pure TITANIUM DIOXIDE. CONCENTRATED ACID SOLUBILITY OF TiO 2 METHOD: T WP

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

5-4 Chemical changes Trilogy

POLYBUTADIENE, LINEAR, CARBOXYL TERMINATED

TREATMENT OF DAIRY WASTE WATER BY MORINGA OLEIFERA AS NATURAL COAGULANT

Estimation of total, permanent and temporary hardness of water (EDTA method)

METHOD 9013A CYANIDE EXTRACTION PROCEDURE FOR SOLIDS AND OILS

TITANIUM DIOXIDE. SYNONYMS Titania; CI Pigment white 6; CI (1975) No ; INS No. 171 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Method 5.2 Syrup and remelt: Brix, NIR pol and purity

Standard Operation Procedure (SOP) Analytical methods in anaerobic digestion batch reactions

TESTING THE WATERS HOW GOOD IS THAT BOTTLED WATER AND HOW EFFECTIVE IS YOUR WATER FILTER

Part A (Level 1) A Matching (4 marks, 1 mark each) B Multiple-choice questions (20 marks, 2 marks each) Name: ( ) Time and Marks Class: Date:

Engineered Systems & Designs TURBIDITY METER

Oxygen Demand, Chemical

2540 SOLIDS* 2540 A. Introduction

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

CH 149: Chemical Principles. Fall KP1019 Module TA Manual

Audit Findings Myths and Legends Panel Discussion

Chem 2115 Experiment #9. Consumer Chemistry: Determining the Iron Content in Supplements

QUALITY CONTROL DEPARTMENT EQUIPMENT LIST

SINTERED GLASSWARE Porosity Grades and their General Use

Catalysts, adsorbents, electrodes. The thick liquid is yellow or gray in color

EDICT ± OF GOVERNMENT

Analysis of Calcium Carbonate Tablets

Biochemical Oxygen Demand Do s and Don ts

Standard Test Methods for Iron in Water 1

Polyvidone Polyvinylpyrrolidone H 2 C H C N

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

SILICA, CRYSTALLINE in coal mine dust, by IR 7603

INTRODUCTION. James N. Craddock, Associate Prof., Department of Civil Engineering, SIUC,

Method 4.2 Filter cake, filter feed and filtrate: Brix, NIR pol and purity

Automated Wizard SV 96 Genomic DNA Purification System for Tissue Samples

Before You Begin. Calibration Protocols

Formazin 4000FTU / 1000EBC / 8200ppm

CLEANING VALIDATION FOOD & BEVERAGE WASTEWATER LABORATORY PHARMACEUTICAL & MEDICAL DEVICE

Method Development and Validation for Online UV-Dissolution Methods Using Fiber-Optic Technology

TECHNICAL GRADE MOLYBDENUM OXIDE

ZENITH bioreactor Model BIOFERM-01-03

á1058ñ ANALYTICAL INSTRUMENT QUALIFICATION

METHOD #: Approved for NPDES (Issued 1971) Oxygen, Dissolved (Modified Winkler, Full-Bottle Technique) ANALYTE: CAS # O Oxygen

First Let s Define some Terms the most important terms used with these concepts are:

MD60002 MD MD62002

Comparison of Water Quality Parameters

TOTAL SULPHITE (SO 2 )

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

For simultaneous purification of genomic DNA and total RNA from the same animal cells or tissues

SASTA Method 3.2: Brix, NIR pol and purity

DRAFT EAST AFRICAN STANDARD

DRPK-005

CHEM 1215 LAB NOTES EXPT #2: PHYSICAL AND CHEMICAL CHANGES 1

TIANamp Soil DNA Kit. For isolation of genomic DNA from soil.

(Applicable to identification of Salmonella in all foods.)

DURNI-COAT DNC

CORESTA RECOMMENDED METHOD N 61

SECTION 347 PORTLAND CEMENT CONCRETE CLASS 1 (NON-STRUCTURAL)

Technical Process Bulletin

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

Analysis of soda and sulfate white and green liquors

Entry Level Assessment Blueprint Biotechnology

Potentiometric analysis of brass and bronze plating baths

Human IgG ELISA Kit. Strip well format. Reagents for up to 96 tests

MOLYBDENITE CONCENTRATES

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Top Tips for Conducting DMR-QA Analyses Waters Corporation 1

Skills in Science. Lab equipment. (Always draw 2D) Drawings below are NOT to scale. Beaker - A general purpose container with a pouring lip.

Bacterial Counts - Quantitative Analysis of Microbes

HiPer Gel Extraction Teaching Kit (Column Based)

DRS 261 RWANDA STANDARD. Herbal petroleum jelly Specification. First edition 2017-mm-dd. Reference number DRS 261: 2017

DAIRY WATERS. (Coliform Group and Escherichia coli) [E. coli verification required only on source water] IMS #24

NOTE Comments are solicited especially on clauses ; ; 6.1.5; and highlighted in document.

ISO 7218 INTERNATIONAL STANDARD. Microbiology of food and animal feeding stuffs General requirements and guidance for microbiological examinations

Method 6.1 Boiling house products: Brix, pol and purity

Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

Facility and Equipment Maintenance

3. Add 0.4 ml of. 7. Use a TenSette

Transcription:

Equipment Needs and Maintenance, What is Required in the Wet Chemistry Laboratory for Manual Method Testing Debra Waller NJDEP-Office of Quality Assurance debra.waller@dep.nj.gov

Evaluation of Suppliers and Vendors Subject to the same review as performed for standards, reagents and reference materials Must be inspected or otherwise verified prior to use Records of the reviews and checks must be maintained Purchasing documentation must include data describing the services and supplies ordered

Equipment The lab shall ensure that all equipment used including equipment outside of its permanent control meets the requirements of the Standard Must be capable of meeting the accuracy required and the method or test being performed Must be operated by qualified (authorized) personnel Up to date instructions for the operation of the equipment must be available to personnel When practical, shall be uniquely identified

Equipment The following records must be maintained/retained at the laboratory: Identity of equipment and its software if used and applicable Manufacturer s name, type identification, serial number or other form of unique identification Records of all checks performed Current location in the laboratory, where appropriate Manufacturer s instructions for use Dates, results and copies of reports and certifications of all calibrations, adjustments, acceptance criteria, and the due date of the next calibration

Equipment Maintenance Procedures must be in place to protect the integrity of the equipment in use whether the equipment is under permanent control by the laboratory or not. Equipment that is not functioning properly must be take out of service, tagged accordingly and reevaluated before continued use Any potential problems with the use of defect detection shall be evaluated accordingly (nonconforming) Records of repairs and maintenance shall be kept including records of service calls.

Equipment Maintenance Whenever practical, all equipment requiring calibration shall be labeled with its current calibration status, due date of the next calibration and all applicable Correction Factors (CFs). All applicable CFs are applied and documentation exists to support the CFs. A defined procedure for intermediate checks when needed. Safeguarded from adjustments that would invalidate the test results.

Equipment Must be calibrated or verified at least annually bracketing the range of use Equipment shall be checked and documented each day of use or more often if required by method or program. Volumetric dispensing devices shall be checked for accuracy on a quarterly basis, where applicable.

Examples of Manual Equipment Titration, iodometric, argentometric, amperometric testing Gravimetric determinations Spectrophotometric/Colorimetric testing Demand Testing: Optical vs. Membrane Nephelometric/Turbidimetric Testing Ion Selective Electrode Testing Manual Sample Preparation Equipment: Distillations, Digestions and Separatory Funnel Extractions Conductance Equipment for Odor testing

Titration Equipment Amperometers Burettes (including micro where required) or Pipettors Pipets and other sample volume measurement devices Stirring Mechanisms ph meters (temperature compensated) or electrometric titrators if used as part of the analysis Magnetic stirrers Titration vessels (i.e. beakers, dishes, flasks) cleaned and treated where applicable, to prevent contamination

Gravimetric Equipment Balances Ovens Furnaces Evaporation dishes/vessels Steam or Water Bath Desiccators Stirring mechanisms Filters and filtration apparatus including vacuum pumps For volumetric testing for settleable solids, Imhoff cones

Spectrophotometric/Colorimetric Spectrophotometers used at the proper wavelength and path length Filter photometers with appropriate filters Cuvettes or absorption cells Nessler tubes or matched test tubes when needed Acid washed labware where required Reduction columns Filtration devices where needed

Dissolved Oxygen Testing: Optical vs. Membrane BOD/CBOD/DO testing requires the use of a membrane electrode or an approved optical probe (i.e. LDO, RDO) unless the DO is determined by the Winkler titration. Incubators Cleaned labware for dilution water prep, sample analysis (i.e. BOD bottles) and QC testing Thermometers/Temperature Measuring devices Supplies to check for chlorine residual Stirring mechanism

Nephelometric/Turbidimetric Testing Nephelometer or Turbidimeter Cleaned labware Stirring mechanism Cuvettes or sample cells

Ion Selective Electrode Testing Selective Ion Electrodes Stirring mechanism

Manual Sample Preparation Equipment: Distillations, Digestions and Separatory Funnel Extractions Hot blocks or hot plates, including turbo vaps Thermometers Distillation apparatus Digestion and distillation vessels Sep funnels, SPE devices

Specific Conductance/Conductivity Conductivity meter and probes Clean testing vessels Thermometer when needed

Equipment for Odor testing Odor free water generator Odor free glassware Constant temperature bath Thermometer