AmpFlSTR Identifiler PCR Amplification Kit

Similar documents
Data Quality Worth Sharing

AmpF STR NGM PCR Amplification Kit - Overview

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

User Bulletin. Veriti 96-Well Thermal Cycler AmpFlSTR Kit Validation. Overview

The Evolution of Short Tandem Repeat (STR) Multiplex Systems

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

PowerPlex. Y System Validation

Development and Validation of the 3500 Series Genetic Analyzer for Human Identification

Short Tandem Repeat (STR) Analysis

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

Uniparental disomy (UPD) analysis of chromosome 15

User Bulletin. ABI PRISM 7000 Sequence Detection System DRAFT. SUBJECT: Software Upgrade from Version 1.0 to 1.1. Version 1.

Expression Array System

Procedure for GeneMapper ID-X for Casework

AmpFlSTR NGM SElect PCR Amplification Kit. User Guide

TaqPath ProAmp Master Mixes

AmpFlSTR COfiler PCR Amplification Kit

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

STR Profiling Matching Criteria: Establishment and Importance of a Cell Line Database

Latest Tools for Human Identification

Generating Forensic DNA Profiles

Notice of Amendment of the FBI s STR Population Data Published in 1999 and 2001

Evaluation of the Autogen FlexSTAR automated DNA extractor, for suitability in routine diagnostic use

TECHNICAL MANUAL. GenePrint 24 System. Instructions for Use of Product B1870 6/16 TM465

Applied Biosystems Informatics Solutions for the Life Sciences. Jason McGlashan Oracle Life Science User Group Meeting

Development of a Global STR Multiplex for Human Identification Analysis

Procedure for Casework DNA Interpretation

Internal Validation of the Promega PowerPlex Fusion System with the Applied Biosystems 3130xl Genetic Analyzer

Maximizing the Performance of Capillary Electrophoresis Systems The Maximizing Data Quality Series Part 4

PowerPlex ESX 17 Fast System for Use on the Applied Biosystems Genetic Analyzers

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Internal DNA extraction control

PowerPlex 5-Dye Matrix Standards, 310

Investigator Quantiplex HYres Kit

STR Interpretation Guidelines

Sanger Sequencing & Fragment Analysis Services à la carte

Capillary Electrophoresis and 5-Channel LIF Detection of a 26plex Autosomal STR Assay for Human Identification

Mutations during meiosis and germ line division lead to genetic variation between individuals

Laboratory Exercise 4. Multiplex PCR of Short Tandem Repeats and Vertical Polyacrylamide Gel Electrophoresis.

A*01:02, 68:02 B*15:10, 58:02 DRB1*03:01, 12:01

Validation of a Multiplexed System for Quantification of Human DNA and Human Male DNA and Detection of PCR Inhibitors in Biological Samples

FORENSIC GENETICS. DNA in the cell FORENSIC GENETICS PERSONAL IDENTIFICATION KINSHIP ANALYSIS FORENSIC GENETICS. Sources of biological evidence

PowerPlex 5C Matrix Standards, 310

Introducing: 3Zomy Aneuploidity Test

GenPlex HID Training Class I

USB HotStart-IT. for increased specificity and consistent results. PCR, qpcr and qrt-pcr

Development of a Global STR Multiplex for Human Identification Analysis

SYBR Green Realtime PCR Master Mix

NRAS Codon 61 Mutation Analysis Reagents

Constructing STR Multiplex Assays

EGFR T790M mutation mutation detection by quantitative allele specific amplification (quasa) EGFR (T790M)

Real-Time PCR Workshop Gene Expression. Applications Absolute and Relative Quantitation

TWGDAM Validation of AmpF STR PCR Amplification Kits for Forensic DNA Casework

M. tuberculosis_mpb64/is611. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

NRAS Mutation Analysis Reagents (Codons 12 and 13)

Troubleshooting: Strategies and Solutions

PowerPlex 4C Matrix Standard

Real-Time PCR Validations

CE and CEC. 1 Introduction. Electrophoresis 2004, 25,

Genomic DNA quantification assay. Quantification of genomic DNA by real-time PCR

Authenticating human cell lines using the Identifiler kits and capillary electrophoresis platforms

Comparison of the Promega Power Y and AB AmpFlSTR YFiler kits and the Subsequent Validation of YFiler.

Quantitative analysis of PCR fragments with the Agilent 2100 Bioanalyzer. Application Note. Odilo Mueller. Abstract

Sus scrofa Pig genesig Speciation Kit

Primerdesign Ltd. High risk Human Papillomavirus. Multiplex screening kit. genesig kit. 100 tests. For general laboratory and research use only

Antibiotic resistance OXA -48 Carbapenem-hydrolyzing β- lactamase (blaoxa-48) gene. genesig Advanced Kit. 150 tests.

PowerPlex 5-Dye Matrix Standards, 3100/3130

GlobalFiler Kit Casework Test Site Results and Other Development Updates

Setting Up a Multiplex (two probe) Real Time 5 Nuclease Reaction on the ABI PRISM 7700 Sequence Detection System

PERFORMANCE MADE EASY REAL-TIME PCR


Human Y chromosome detection assay. Detection of the human Y chromosome by real-time PCR

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

John M. Butler and Peter M. Vallone National Institute of Standards and Technology

ON-CHIP AMPLIFICATION OF GENOMIC DNA WITH SHORT TANDEM REPEAT AND SINGLE NUCLEOTIDE POLYMORPHISM ANALYSIS

SeCore SBT Sequence Based Typing

Characterization of 26 MiniSTR Loci for Improved Analysis of Degraded DNA Samples

SUBJECT: System Software Patch Provides Support for Fast SYBR Green Master Mix and RNA-to-C T

Sus scrofa Pig genesig Advanced Speciation Kit

JAK2 V617F mutation mutation detection by quantitative allele specific amplification (quasa) JAK2(V617F)

The Polymerase Chain Reaction. Chapter 6: Background

The Polymerase Chain Reaction. Chapter 6: Background

User Manual. Chromofy dsdna binding dye Version 1.0 April 2009 For use in quantitative real-time PCR

DNA Genotyping from Human FFPE Samples Reliable and Reproducible

Devyser Extend ART.No. 8-A015

STR Analysis Following Latent Blood Detection by Luminol, Fluorescein, and BlueStar

Premix Ex Taq (Probe qpcr)

Lecture Four. Molecular Approaches I: Nucleic Acids

AUTOMATION OF DNA ISOLATION, QUANTITATION, AND PCR SETUP

The right answer, every time

MSI Analysis System, Version 1.2

Laboratory Validation. Chapter 16

LightScanner Hi-Res Melting Comparison of Six Master Mixes for Scanning and Small Amplicon and LunaProbes Genotyping

STUDY OF VNTR HUMAN POLYMORPHISMS BY PCR

BRAF V600E mutation mutation detection by quantitative allele specific amplification (quasa) BRAF (V600E)

Human bocavirus. Viral protein (VP) gene. 150 tests. Quantification of Human bocavirus genomes. Advanced kit handbook HB

LabChip 90 System with DataViewer Software

User Manual. VisiBlue qpcr mix colorant. Version 1.3 September 2012 For use in quantitative real-time PCR

Acinetobacter baumannii

Apium graveolens Celery/Celeriac. genesig Allergen detection Kit. 100 tests. Primerdesign Ltd. For general laboratory and research use only

Transcription:

Product Bulletin Human Identification AmpFlSTR Identifiler PCR Amplification Kit Fifteen STR (short tandem repeat) loci and Amelogenin co-amplified in a single tube Incorporation of the same proven, reliable primer sequences previously used in all AmpFlSTR Kits 1 Loci consistent with all major worldwide STR databasing standards Five-dye fluorescent DNA technology enables high-throughput analysis and maintains desirable small amplicons Complete system including reagents, ABI PRISM genetic analysis instrumentation, software, technical support, and specific limited license rights for forensic, paternity, and research use Significant reduction in artifacts now observed in both PET and VIC dye results High-Throughput Databasing Multiplex Drawing from the technology supporting the reliable, trusted AmpFlSTR PCR Amplification Kits, Applied Biosystems delivers its single most discriminating fluorescent STR-based assay for human identification applications. The AmpFlSTR Identifiler PCR Amplification Kit simultaneously amplifies 15 STR loci plus the Amelogenin gender-determining marker in a single, robust PCR. The widely accepted tetranucleotide loci co-amplified in the Identifiler Kit include the thirteen core STR loci as required for sample entry into CODIS (Combined DNA Index System): CSF1PO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, and vwa. The data generated from these loci also satisfy the recommendations of the European Network of Forensic Science Institutes (ENFSI) and Interpol organizations. D8S1179 D21S11 D7S820 CSF1PO D3S1358 TH01 D13S317 D16S539 D2S1338 D19S433 vwa TPOX D18S51 Amelogenin D5S818 FGA GeneScan -500 LIZ Size Standard Figure 1. GeneScan software electropherogram showing the AmpFlSTR Identifiler PCR Amplification Kit results for fifteen STR loci and the Amelogenin locus analyzed on the ABI PRISM 3100 Genetic Analyzer. DNA fragments are labeled in 6-FAM dye (blue), VIC dye (green), NED dye (yellow, depicted in black), and PET dye (red). The GeneScan-500 size standard is labeled with LIZ dye (orange).

Two additional tetranucleotide loci, D2S1338 and D19S433, provide concordance with the AmpFlSTR SGM Plus PCR Amplification Kit, which was developed in collaboration with the Forensic Science Service (FSS). The combination of loci included in the Identifiler Kit renders it the most powerful AmpFlSTR Kit currently available. Speed and Throughput Previously, submission of samples to CODIS required genetic information generated from two separate PCR amplifications, such as the AmpFlSTR Profiler Plus and AmpFlSTR COfiler PCR Amplification Kits. To simplify this process and increase databasing throughput, the Identifiler Kit features a robust, 16-locus multiplex PCR, which cuts the preparation and labor of amplification and analysis in half. Now with the Identifiler Kit, a single multiplex PCR, followed by one capillary electrophoresis injection or gel lane analysis, is all that is necessary to provide complete databasing information for an individual sample. While enhancing throughput with a single amplification is a key feature of the Identifiler Kit, other factors are important to the human identification laboratory, including robustness and reliability of the PCR amplification. The AmpFlSTR Identifiler Kit was designed as a single amplification with these important design goals in mind: Identical primer sequences among all AmpFlSTR Kits 1 Amplicon allele size ranges between 100 to 360 base pairs for robust PCR amplification of all loci A complete system approach designed for flexibility choose the ABI PRISM system appropriate for your laboratory s analysis needs Locus Chromosome Alleles included in Identifiler Dye Label Designation Location Allelic Ladder D8S1179 8 8-19 D21S11 21q11.2-q21 24, 24.2, 25-28, 28.2, 29, 29.2, 30, 30.2, 31, 31.2, 32, 32.2, 33, 33.2, 34, 34.2, 35, 35.2, 36-38 6-FAM D7S820 7q11.21-22 6-15 CSF1P0 5q33.3-34 6-15 D3S1358 3p 12-19 TH01 11p15.5 4-9, 9.3, 10, 11, 13.3 D13S317 13q22-31 8-15 VIC D16S539 16q24-qter 5, 8-15 D2S1338 2q35-37.1 15-28 D19S433 19q12-13.1 9-12, 12.2, 13, 13.2, 14, 14.2, 15, 15.2, 16, 16.2, 17, 17.2 vwa 12p12-pter 11-24 NED TPOX 2p23-2per 6-13 D18S51 18q21.3 7, 9, 10, 10.2, 11-13, 13.2, 14, 14.2, 15-27 Amelogenin X: p22.1-22.3 Y: p11.2 X, Y D5S818 5q21-31 7-16 PET FGA 4q28 17-26, 26.2, 27-30, 30.2, 31.2, 32.2, 33.2, 42.2, 43.2, 44.2, 45.2, 46.2, 47.2, 48.2, 50.2, 51.2 Table 1. The AmpFlSTR Identifiler Kit Loci. All STR loci included in the AmpFlSTR Identifiler PCR Amplification Kit are co-amplified in a single PCR and analyzed simultaneously in a single gel-lane or capillary electrophoresis injection with ABI PRISM systems. Population Average Probability Power of Average Probability of Identity Discrimination of Paternity Exclusion African American 1.31 x 10-18 1 in 7.64 x 10 17 0.9999996 n = 357 US Caucasian 5.01 x 10-18 1 in 2.00 x 10 17 0.9999992 n = 349 US Hispanic 7.65 x 10-18 1 in 1.31 x 10 17 0.9999990 n = 290 Native American 3.62 x 10-17 1 in 2.76 x 10 16 0.9999527 n = 191 Table 2. Population Genetics of the AmpFlSTR Identifiler Kit Loci. These features make the Identifiler Kit suitable for database, forensic, and paternity laboratories. Each laboratory using the Identifiler Kit should perform appropriate validation studies.

Five-Dye Technology Although the use of four fluorescent dyes (5-FAM, JOE, NED, and ROX dyes) to label DNA fragments for automated STR analysis provides a significant increase in throughput over more traditional methods (such as those based on silver staining, radioactivity, or chemiluminescence), an increasing demand for genotypic information requires even higher-throughput solutions. Applied Biosystems introduced a five-dye system for automated DNA fragment analysis, enabled by the development of two proprietary fluorescent dyes. By adding additional dyes to the AmpFlSTR Identifiler Primer Set, more loci are multiplexed in a single gel lane or capillary injection. The new PET and LIZ dyes (depicted as red and orange, respectively, by GeneScan Software version 3.1 or higher) are specifically designed to expand the spectral detection range on ABI PRISM genetic analysis instrumentation. Together with 6-FAM, VIC, and NED dyes, the spectral emission for this five-dye set extends to 660 nm. By comparison, the four-dye set consisting of 5-FAM, JOE, NED, and ROX dyes (dye set F ) yields a spectral range extending to 610 nm. The expanded spectral range of the five-dye set allows color separation comparable to the four-dye set, minimizing spectral overlap. In this five-dye set, 6-FAM, VIC, NED, and PET dyes are used to label PCR fragments, while LIZ dye is used to label the GeneScan-500 size standard. Emission Spectra Emission of Four-dye Spectra Setof 4-Dye Set Normalized Emission 100 80 60 40 20 0 500 550 600 650 700 Wavelength (nm) 5-FAM dye JOE dye NED dye ROX dye Figure 2a. Shown above are the emission spectra of 5-FAM, JOE, NED, and ROX dyes used with the AmpFlSTR Profiler Plus, COfiler, and SGM Plus kits. Emission Spectra Emission of Five-dye Spectra Setof 5-Dye Set Normalized Emission 100 80 60 40 20 0 500 550 600 650 700 6-FAM dye PET dye Wavelength (nm) VIC dye LIZ dye NED dye Figure 2b. Shown above are the emission spectra of 6-FAM, VIC, NED, PET, and LIZ dyes used with the AmpFlSTR Identifiler Kit. This dye set was specifically designed to expand the spectral detection range on ABI PRISM genetic analysis instrumentation. ABI PRISM Samples Number of Days in Samples System per Run Runs per Day Operation per Year 310 48 1 335 16,080 377 (34-lanes) 34 3 240 24,480 377 (96-lanes) 96 3 240 69,120 3100 16 24 240 92,160 Table 3. Examples of sample throughput for ABI PRISM systems based upon a 9-hour workday.

D8S1179 D21S11 D7S820 CSF1PO D3S1358 TH01 D13S317 D16S539 D2S1338 D19S433 vwa TPOX D18S51 Amelogenin D5S818 FGA Figure 3. GeneScan software plot of the AmpFlSTR Identifiler Allelic Ladder analyzed on the 310 genetic analyzer. The new PET dye (red) used to label PCR products increases in-lane multiplexing throughput capabilities when used along with 6-FAM, VIC, and NED dyes. The AmpFlSTR Identifiler Allelic Ladder includes additional alleles for D18S51, D21S11, FGA, TH01, and vwa loci as compared to the AmpFlSTR Profiler Plus and Cofiler Allelic Ladders. Trusted AmpFlSTR Kit Primer Sequences Remain Unchanged By combining the five-dye system with carefully selected, non-nucleotide linkers placed between the primer and the fluorescent dye during oligonucleotide synthesis of the Identifiler Kit primers, the same robust primer sequences developed for previous AmpFlSTR Kits are used without modification. The non-nucleotide linkers enable reproducible positioning of the alleles to facilitate inter-locus spacing. Maintaining primer sequences means that current users of the AmpFlSTR Profiler Plus, COfiler, and SGM Plus kits may quickly adopt the Identifiler Kit with complete confidence. 1 In addition, small amplicons less than 360 base pairs are maintained, ensuring robust PCR amplification. Reduction of Artifacts In Applied Biosystems continual efforts to improve the quality of our products, we have made some modifications to the manufacturing process of the Identifiler Kit. For samples amplified with the Identifiler Kit, these modifications reduce the artifacts that are observed in both PET dye and VIC dye results. A VIC dye labeled artifact was observed at approximately 120 bp. In order to address this artifact, an additional step has been introduced in the purification process of the VIC dye labeled PCR primers in the Identifiler Kit. PET dye labeled artifacts have also been observed between the Amelogenin and the D5S818 loci. A modification to the manufacturing process of the PET dye labeled primers has been introduced, while maintaining the primer sequences, resulting in a reduction in the artifacts visualized. As noted in the Identifiler Kit User s Manual (PN 4323291), non-nucleotide linkers are

VIC dye labeled artifact at ~120 bp PET dye labeled artifacts observed between the Amelogenin and the D5S818 loci Previously released Identifiler Kit, lot number 0301011 (representitive of lots 0103001 to 0308017) Identifiler Kit, lot number 0310018 Figure 4. Comparison of the observed VIC dye labeled and PET dye labeled artifacts for negative control amplifications with a previously released Identifiler Kit, lot number 0301011, and lot number 0310018. DNA was generated using the ABI PRISM 310 Genetic Analyzer with the Windows NT OS using the G5 module. The artifacts have been highlighted for illustrative purposes. Both the VIC dye labeled and PET dye labeled artifacts are greatly reduced in the bottom panels. used in primer synthesis between the primer oligonucleotides and the dye. The non-nucleotide linkers enable reproducible positioning of the alleles to facilitate inter-locus spacing. The PET dye artifacts were observed to be correlated with the use of a particular non-nucleotide linker. By using a different non-nucleotide linker during synthesis of the PET dye labeled primers in the Identifiler Kit primer set for this kit, the PET dye artifacts are now observed to be significantly diminished. The modifications made in the production of the PET and VIC dye labeled primers are reflected in both the Identifiler primer sets and the Identifiler Allelic Ladder. Complete System Approach Applied Biosystems offers fully integrated reagents, instruments, and software for processing data generated in human identification laboratories. DNA samples amplified with the Identifiler Kit may be analyzed with the ABI PRISM genetic analysis instrument that accommodates an individual laboratory s throughput needs. (Each ABI PRISM genetic analysis instrument must be equipped with a version of data collection software capable of five-dye analysis, and the instrument calibrated with the appropriate matrix standards.) For postcollection software packages, choose from Applied Biosystems analysis software products. Sample tracking and data management requirements for databasing laboratories can be met with Applied Biosystems SQL*GT Laboratory Information Management System (LIMS). Experienced technical application specialists are available to answer questions you may have, including field specialists who provide on-site assistance in the use of our entire product line. We also offer forensic training courses to implement STR technology in your laboratory to help you develop complete competence and confidence in its use. Product Specifications Each AmpFlSTR Identifiler Kit contains pre-formulated AmpFlSTR PCR Reaction Mix, blended AmpFlSTR Identifiler Primer Set, and AmpliTaq Gold DNA Polymerase sufficient for 200 tests. Each kit also contains AmpFlSTR Control DNA 9947A of a known genotype and AmpFlSTR Identifiler Allelic Ladder. The AmpFlSTR Identifiler Allelic Ladder includes additional alleles for D18S51, D21S11, FGA, TH01, and vwa loci, as compared with the AmpFlSTR Profiler Plus and COfiler Allelic Ladders. The PCR reaction components, primer sequences, and amplification protocols have all been developed to provide specific, robust amplification. Validation experiments have been performed according to Quality Assurance Standards for Forensic DNA Testing Laboratories (DNA Advisory Board).

The Identifiler Kits are subjected to rigorous quality control testing to ensure reliable performance. Applied Biosystems develops and manufactures its products in accordance with ISO 9001 quality system requirements. Additionally, a Certificate of Analysis is available upon request that confirms that the specific combination of components within a lot meets qualityassurance testing specifications. The AmpFlSTR Identifiler Kit conveys certain PCR rights to perform paternity testing services. When used in conjunction with an Authorized Thermal Cycler, the Identifiler Kit also conveys certain PCR license rights for forensic and research use. References 1 In order to address a mutation observed in a population of Chamorros and Filipinos from Guam, a degenerate unlabeled primer for the D8S1179 locus has been added to the AmpFlSTR Identifiler Primer Set. The addition of the degenerate primer allows the amplification of those alleles in samples containing this mutation without altering the overall performance of the AmpFlSTR Identifiler PCR Amplification Kit. iscience. To achieve accurate, reproducible results, life scientists are taking advantage of advanced analysis systems that unite technology, informatics, and traditional laboratory research. In partnership with our customers, Applied Biosystems provides the innovative products, services, and knowledge resources that make this new, Integrated Science possible. Worldwide Sales Offices Applied Biosystems vast distribution and service network, composed of highly trained support and applications personnel, reaches 150 countries on six continents. For international office locations, please call the division headquarters or refer to our Web site at Ordering Information Description Quantity P/N AmpFlSTR Identifiler PCR Amplification Kit 200 tests, 25 µl/test 4322288 AmpFlSTR Identifiler PCR Amplification Kit User s Manual 1 manual 4323291 GeneScan -500 LIZ Size Standard 800 reactions 4322682 Matrix Standard Set DS-33 (6-FAM, VIC, NED, PET, LIZ dyes) for use with 310 and 377 systems 1 tube with 5 dyes 4318159 Matrix Standard Set DS-33 (6-FAM, VIC, NED, PET, LIZ dyes) for use with 3100 and 3100-Avant systems 1 tube with 5 dyes 4323016 Applera is committed to providing the world s leading technology and information for life scientists. Applera Corporation consists of the Applied Biosystems and Celera Genomics businesses. Headquarters 850 Lincoln Centre Drive Foster City, CA 94404 USA Phone: 650.638.5800 Toll Free: 800.345.5224 Fax: 650.638.5884 For Research, Forensic, or Paternity Use Only. Not for use in diagnostic procedures. The PCR process is covered by patents owned by Roche Molecular Systems, Inc. and F. Hoffman-La Roche Ltd. AB (Design), FAM, iscience, iscience (Design), JOE, NED, ROX, and SQL*GT are trademarks, and ABI PRISM and its design, AmpFlSTR, Applied Biosystems, Applera, COfiler, Identifiler, GeneScan, LIZ, Profiler Plus, SGM Plus, PET, and VIC are registered trademarks of Applera Corporation or its subsidiaries in the US and/or certain other countries. 2004. All Rights Reserved. Printed in the USA, 06/04, P+s, Publication 112PB01-06