Mixing conditions of polymer and ceramic powder determined by ultrasound

Similar documents
SCREW DESIGN BASICS The Processor Point Of View. Andrew W. Christie Optex Process Solutions, LLC

ADHESIVE CURE MONITORING WITH ACOUSTIC METHOD

Examination of the Performance of a High Speed Single Screw Extruder for Several Different Extrusion Applications

MiniLab-Compounder and Reactor

Study of Surface Acoustic Wave Streaming Phenomenon Based on Temperature Measurement and Observation of Streaming in Liquids

Practical challenges during high temperature ultrasonic scanning

Options. The following is a list of our most popular options. If you don t find what you need, please call us. HARDWARE

INVESTIGATIONS ON RELATIONSHIP BETWEEN POROSITY AND ULTRASONIC ATTENUATION COEFFICIENT IN CFRP LAMINATES BASED ON RMVM

Module 8: Composite Testing Lecture 36: Quality Assessment and Physical Properties. Introduction. The Lecture Contains

Contents. 1. Making a Blue Tank 2. Material Production Options 3. Methods for Adding Color 4. Grinding the Pellets 5. Benefits of Using Micros

Closely Intermeshing Counter-Rotating Twin Screw Extrusion of Polymers

EFFECT OF SCREW SPEED ON POLYETHYLENE-CALCIUM CARBONATE COMPOSITES PRODUCED USING TWIN AND QUAD SCREW EXTRUDERS

Twin Screw Extrusion Systems to Process PLA More Efficiently

Contact Laser Ultrasonic Evaluation (CLUE) of Aerospace Materials and Parts

MECHANICS OF PASTE FLOW IN RADIAL SCREEN EXTRUDERS

ELONGATIONAL FLOW IN MULTIPLE SCREW EXTRUDERS

LCM CC & TCC. A member of the Possehl Group

AN EXPERIMENTAL STUDY OF THE FLOWS IN AN ENERGY TRANSFER SCREW

DEVELOPMENT OF IN-SITU MONITORING SYSTEM FOR SINTERING OF CERAMICS USING LASER AE TECHNIQUE

PROCESSING MICA BASED PIGMENT MASTERBATCH

Monitoring Of Adhesive Cure Process and Following Evaluation of Adhesive Joint Structure by Acoustic Techniques

1. 3 Extrusion molding

Trench Structure Improvement of Thermo-Optic Waveguides

A MECHANISM FOR SOLID BED BREAKUP IN SINGLE-SCREW EXTRUDERS

DETECTION OF INCLINED CRACKS INSIDE CONCRETE STRUCTURES BY ULTRASONIC SAFT

CHARACTARISTICS OF DAMAGE AND FRACTURE PROCESS OF SOLID OXIDE FUEL CELLS UNDER SIMULATED OPERATING CONDITIONS BY USING AE METHOD

ANALYSIS OF TEMPERATURE INFLUENCE ON INJECTION MOLDING PROCESS

SIMULATION OF CO-ROTATING FULLY INTERMESHING TWIN-SCREW COMPOUNDING EXTRUDERS: ALTERNATIVES FOR PROCESS DESIGN

The Potential of Silane Coated Calcium Carbonate on Mechanical Properties of Rigid PVC Composites for Pipe Manufacturing

Endex Foam Extrusion General Information Guide

Evaluation of Ultrasonic Attenuation and Estimation of Ultrasonic Grain Noise in Copper

Notes. Plastic Behavior In The Compounding Twin Screw Extruder. Lesson 4. I. Screw Terminology. A. Length to Diameter Ratio (L/D ratio)

THERMAL CONDUCTIVITY TESTS OF LIQUIDS USING FOX50 HEAT FLOW METER INSTRUMENT (Amendment the FOX50 Instrument Manual)

Advances in Twin Screw Compounding Technology

RANDCASTLE EXTRUSION SYSTEMS INC.

ANALYSIS OF AE DURING RESISTANCE SPOT WELDING. Tomaž KEK, Janez GRUM, Ivan POLAJNAR

Recent Advances in NDE Technologies for Turbines and Generators

Vibration Analysis Machinery Inspection & Evaluation Level II

Ultrasonic testing of adhesive bonds of thick composites with applications to wind turbine blades

Mathematical Modeling of Impulsive Forming Processes Using Various Energy Sources and Transmitting Medium

IMPACT DAMAGE DETECTION ON SCARF-REPAIRED COMPOSITES USING LAMB WAVE SENSING

Correlation Study between the Rheological Property and the Free Volume for Ethylene Vinyl Acetate Copolymer under Melt Extrusion

Optimizing Extruder Controls, Part Two

Extrusion. Key Issues to Address. Lecture 2. Process. Process Variants. Process Analysis. Problem Solving

Acoustic Emission Crack Detection at Injection Molding Process

EFFECTS OF GRAPHITE SELECTION ON THERMALLY CONDUCTIVE COMPOUNDS FOR LED LAMP HEAT SINKS

Thermal Stability of an Alumina-Based Refractory

Vibration Analysis of Propeller Shaft Using FEM.

Mixing ratios obtained using screw disc and screw extruders, and selected properties of mixture of reglanulate and original material

Stanyl ForTii F11. Recommendations for injection molding MATERIAL HANDLING

SAMPLE SPECIFICATION for CROSSHOLE SONIC LOGGING (CSL) September 2015

Stress analysis of reciprocating pump pipeline system in oil station

NRC Publications Archive Archives des publications du CNRC

Ultrasonic Imaging of Electrofusion Welded Polyethylene Pipes Employed in Utilities Industry

Thermal and Rheological Evaluation of Pharmaceutical Excipients for Hot Melt Extrusion

APN029. The SER2 Universal platform for material testing. A.Franck TA Instruments Germany

Die design and process optimization of plastic gear extrusion

INTRODUCTION. Table 1. Typical applications for LDPE and Ateva EVA copolymers. Category Typical Applications Advantages

REPLICATION OF MIXING ACHIEVED IN LARGE CO- ROTATING SCREW EXTRUDER USING A NOVEL LABORATORY G MINIMIXER

GROOVED FEED SINGLE SCREW EXTRUDERS - IMPROVING PRODUCTIVITY AND REDUCING VISCOUS HEATING EFFECTS

Woodpulp fibres as reinforcements for high-melting engineering thermoplastics for under-the-hood automotive applications

Improved Processing and Batch Time Reduction Through Powder Liquid Dispersions

UT WITH SH-WAVES AND ELECTROMAGNETIC ULTRASONIC (EMUS) -TRANSDUCERS

REVIEW. E N H A N C I N G MELTING AND MIXING in a Twin-Screw Extruder. Capabilities. Page 1 of 5

alpha single screw extruders

Design and Testing of a Rotating Detonation Engine for Open-Loop Gas Turbine Integration

Embedded Mold Temperature Sensor

Modal Analysis as a Tool to Resolve Pump Vibration Issues

ON- AND OFF-LINE ULTRASONIC INSPECTIONS TO CHARACTERIZE COMPONENTS BUILD BY SLM ADDITIVE MANUFACTURING

Non Destructive Testing Monitoring Thermal Power Stations

FEED ENHANCEMENT TECHNOLOGY FOR LOW BULK DENSITY MATERIAL INTO CO-ROTATING TWIN-SCREW COMPOUNDING EXTRUDERS

Using Thermal Integrity Profiling to Confirm the Structural Integrity of foundation applications

Calcium Carbonate in Blown HDPE Film

ULTRASONIC TESTING OF GLASS FIBER REINFORCED COMPOSITE WITH PROCESSING DEFECTS

INJECTION MOLDING OF PULSE ENGINEERING RESINS (unfilled & filled grades)

Pressure Pulsations and Vibration Measurements in Francis Turbines with and without Freely Rotating Runner Cone Extension

Monitoring Sand Transport Characteristics in Multiphase Flow in Horizontal Pipelines Using Acoustic Emission Technology

High Modulus Carbon Fibres in Super-Structural Compounds

A Novel Extrusion Microns Embossing Method of Polymer Film

Continuous Rheocasting for Aluminum-Copper Alloys

Available online at ScienceDirect. Procedia Engineering 81 (2014 )

The Influence of Grain Size of Dissimilar Welding between Carbon Steel and Stainless Steel on Ultrasonic Testing

Effect of Processing Parameters on Polypropylene Film Properties

Discharge Characteristics of DC Arc Water Plasma for Environmental Applications

A NOVEL ELECTRICAL POTENTIAL DROP METHOD FOR THE DETECTION OF NAPHTHENIC ACID CORROSION IN OIL REFINING PROCESSING

Michael T. Anderson, Stephen E. Cumblidge, Steven R. Doctor Pacific Northwest National Laboratory, Richland, WA, USA

NONDESTRUCTIVE EVALUATION (NDE) METHODS FOR QUALITY ASSURANCE OF EPOXY INJECTION CRACK REPAIRS

Recent Servomotor Technology

Non Destructive Evaluation of Rolls of Hot Strip Mill of Tata Steel

Application of linear frequency modulated excitation on ultrasonic testing for austenitic stainless steel welds

Chemical Foaming Alternatives to Azodicarbonamide

Bonded Neo Magnetization Guide

Microstructural Evolution of Ti-Mo-Ni-C Powder by Mechanical Alloying

FULL-DENSIFICATION OF SLS PARTS BY RE-MELTING. Abstract

PLASTIC WELDING PROCESS SIGNATURE

IMPROVE MIXING BY GENERATING ELONGATIONAL FLOW

Structural Integrity Monitoring of Smelting Furnaces Based on Acoustic Emission Data Acquisition and Analysis

PREPARED BY: DR. RAHIMAH OTHMAN FOOD ENGINEERING (ERT 426) SEMESTER 1 ACADEMIC SESSION 2016/17

Acoustic Emission Monitoring of Reinforcing Bars Pull-out from Concrete Matrix

University of Michigan

Transcription:

International Journal of Applied Science and Engineering 2009. 6, 3: 239-244 Mixing conditions of polymer and ceramic powder determined by ultrasound C. C. Cheng * Dept. of Electrical Engineering, Hsiuping Institute of Technology, Da-Li, Taichung Abstract: Mixing process in the internal mixer has been monitored by ultrasonic technology real-time, non-intrusively and non-destructively. Visual observation, mechanical torque measurement, and ultrasonic signatures, such as amplitude of transmission and reflection echoes, were used for the diagnosis of the melting process of low density polyethylene (LDPE) and the mixing process of the melted LDPE with a calcium carbonate (CaCO 3 ) powder. Phenomena during the melting and mixing processes, including phase change from solid to melt, and distributing progress of CaCO 3 powder were successfully monitored by ultrasound. The ultrasonic signature was able to determine when the polymer had melted thoroughly and mixed with CaCO 3 powder completely. The presented ultrasonic technique can be utilized to optimize the melting and mixing processes. Keywords: Mixing condition; internal mixer; ultrasound. 1. Introduction Mixing, including both solids and liquids, is a fundamental and important process for many fields: combustion, the chemical, food and pharmaceutical industries, biotechnology, polymer processing, environmental engineering, and so on. (1-2). The internal mixer is one of the essential static mixing instruments widely used in most laboratories working on polymer or powder material process. It is usually used as a preliminary testing step for verifying the melting and mixing behaviors of polymers, chemical reactions in polymers, cross-linking and degradation of polymer before the actual processing in extruder. Ultrasonic technique is one of the candidates for monitoring the different melting and mixing stages during such process, because its basic signatures are associated with properties of materials, process dynamics, and product qualities (3-5). The objective of this research is to investigate ultrasonic signatures during melting and mixing processes in the internal mixer for optimization. 2. Experiments An ultrasonic delay line probe, as shown in Figure 1 (a), is installed into the mixing chamber of internal mixer. The central frequency of the employed ultrasonic transducer (UT) is 10MHz. The ultrasonic delay line probe can operate up to 600 C, and the UT end of the probe can be cooled down to a temperature lower than 40 C. A rotating blade with roller shape, as shown in Figure 1 (b), was installed into the internal mixer for grinding and mixing material. The dimensions of the head of the rotating blade are 36.7mm in diameter and 47mm in length. * Corresponding author; e-mail: newmanch@mail.hit.edu.tw Accepted for Publication: February 19, 2009 2009 Chaoyang University of Technology, ISSN 1727-2394 Int. J. Appl. Sci. Eng., 2009. 6, 3 239

C. C. Cheng (a) Ultrasonic Delay Line Probe (b) Rotating Blade 36.7 mm 47 mm Ultrasonic Transducer Figure 1. Photographs of ultrasonic delay line probe with ultrasonic transducer and rotating blade. The internal mixer, as shown in Figure 2, is equipped with a mixing chamber, an ultrasonic delay line probe, a thermocouple and a torque meter connecting to the driving motor. The mixing chamber has two cylindrical housings for melting and mixing processes. These two housings have the capacity of 60ml. The internal mixer can operate up to 300 C and rotate up to 108 rotation per minute (RPM). Cooling Tube Ultrasonic Delay Line Probe Thermal Couple Feeder Mixing Chamber Connecting Cable Figure 2. Photograph of mixing chamber with thermocouple and ultrasonic delay line probe. A schematic drawing of a cross-section of the mixing chamber is given in Figure 3. It illustrates the paths of ultrasound propagating in the probe and the polymer melt. The first round trip ultrasonic longitudinal-wave echo, indicated by L 1, is reflected at the probe end/polymer interface. The 1 st round trip echo from the flight of the rotating blade half through the polymer melt and reach back to UT is. The torque meter was attached to the rotator of the driving motor, and a K-type thermal couple was located at 0.2mm-depth from the inside surface of mixing chamber bottom, as shown in Figure 3. The torque and temperature profiles are used for comparison with ultrasonic data. The material employed is LDPE and CaCO 3. The procedures of melting and mixing processes were as follows: First, the empty mixing chamber was heated up to the setting temperature of 200 C and the blades were rotating at the desired speed of 14 RPM. Then the LDPE polymer pellets, 45g, were fed into the housings for melt. After the LDPE pellets being melted completely, the additional 4g CaCO 3 powder were fed into the mixing chamber for mixing with the melted LDPE. Flight (#1) Root Ultrasonic Delay Line Probe UT L 1 3 1 Solid Pellets 2 Polymer Melt Rotating Blades Thermal Couple Figure 3. Schematic drawing of cross-section of mixing chamber, including ultrasonic delay line probe, rotating blade and thermocouple, presents ultrasonic paths in probe and polymer. 3. Results and discussions Figure 4 shows the ultrasonic signal acquired by the ultrasonic transducer at the process time from 83.90 to 84.05s when LDPE had melted. The ultrasonic signal L 1 was observed in the entire process. When the flight of rotating blade arrived below the probe location, the echo appeared at time 240 Int. J. Appl. Sci. Eng., 2009. 6, 3

Mixing conditions of polymer and ceramic powder determined by ultrasound delay of 50.4µs from process time 83.94 to 84.03s. Echoes reflected from the other two flights had the similar waveforms. Figure 5. Amplitude of echo from rotating blade (see Figure 3) in process time after polymer is melted. Time (s) 84.05 0.30 84.00 0.25 83.95 0.20 L 1 83.90 0.15 46 47 48 49 50 51 52 Time Delay (μs) Figure 4. Sample traces of ultrasonic waveforms showing L 1 and echoes. In order to investigate the correlation between ultrasonic signals observed and the processing cycle, the amplitude values of the echoes with respect to the process time were obtained. Figure 5 presents the amplitude of the echo from one of the three flights with respect to the process time, when polymer was melted. At process time around 77.71s, peak amplitude of the echo was observed. The duration of pulse was around 0.1s. Amplitude (V) 0.15 0.10 0.05 Peak Point 0.00 77.5 77.6 77.7 77.8 77.9 78.0 Time (s) Figure 6 (a) ~ (d) present the amplitudes variation of torque, temperature, ultrasonic L 1 echo, and peak value of ultrasonic echo, respectively. They were recorded during the melting and mixing processes under the temperature setting of 200 C and rotation speed of 14 RPM. It is noted that the presented peak values of echo were from the same flight of the blade. Figure 7 (a) ~ (f) are photographs of the melting and mixing processes in Figure 6 at the process times of 37, 64, 85, 154, 172, and 180s, respectively. In the following, the torque and temperature profiles will be compared with the visible observation to explain the melting and mixing processes. Then the ultrasonic signals will be added for further investigation. Torq (Nm) Temp ( o C) Amplitude Amplitude (V) Amplitude (V) (V) LDPE (45g) In (30s) 12 9 64s 6 3 0 190 180 170 160 150 4.60 4.55 68s Torque Peak Temperature Bottom Melting Completion (84.6s) 4.50 L 1 0.16 60s 84.6s (d) 179.7s 0.08 Air Bubble Effect 0.00 0 50 100 150 200 250 Time (s) CaCO 3 (4g) In (150s) 172s 158s (a) (b) Mixing (c) Completion (179.7s) Figure 6. Variation of (a) torque, (b) temperature, (c) amplitude of L 1 and (d) peak value of echo during melting and mixing processes. 45g LDPE introduced at 30s; 4g CaCO 3 at 150s. Int. J. Appl. Sci. Eng., 2009. 6, 3 241

C. C. Cheng (a) 37 s (b) 64 s (c) 85 s (d) 154 s (e) 172 s (f) 180 s Figure 7. Photographs from feed window of melting and mixing processes in Figure 6 at process time of 37, 64, 85, 154, 172, and 180s. In Figure 6 (a) and (b), before the process time of 30s, the mixing chamber was heated up to 188 C and the blade rotated at the speed of 14RPM. One can notice that even under the temperature setting of 200 C, the actual chamber temperature was 188 C, due to the heating loss from the feed window. At the process time of 30s, 45g of LDPE were fed into the mixing chamber. From process time of 30 to 64s, the torque value increased due to the friction, and temperature decreased due to the heat transfer between polymer pellets, rotating blades and mixing chamber. At process time of 64 and 68s, the torque and temperature reached their peak and bottom values of 10.9Nm and 152.1 C, respectively. After that, the torque decreased due to the reduction of viscosity of the polymer melt, and temperature increased due to the heat coming from the heating coils, friction and shear forces exceeding that absorbed by the polymer. At process time of 150s, additional 4g CaCO 3 powder were fed into the mixing chamber for the mixing process. At the process time of 158s, the torque and temperature values decreased to the bottom value of 4.8Nm and 177.9 C, respectively. The introduced CaCO 3 powder caused that viscosity reduced and heat transferred. After this point, the temperature increased due to the reason mentioned above. At process time of 172s, torque reached to peak value of 5.3Nm. After that, the torque decreased due to the reduction of viscosity. At process time of 250s, the mixing process stopped since the torque reached a steady state and the temperature almost recovered its original value. The above results will be compared with photographs in Figure 7. In Figure 7 (a), at the process time of 37s, some of the pellets were still in the feed window and did not enter into the mixing chamber yet. In Figure 7 (b), at process time of 64s, which was the time that torque reached its peak value, most of the pellets were in the elastic solid form and bound with rotating blade. In Figure 7 (c), at process time of 85s, most of the solid pellets had been melted and dispersed in the mixing chamber. After the process time of 85s, even though the torque and temperature still varied, there were no solid or partially melted pellets left and the polymer melt didn t appear to change significantly. This may indicate that, after the process time of 85s, most pellets were already melted. At process time of 150s, additional 4g CaCO 3 powder were fed into the mixing chamber. In Figure 7 (d), at the process time of 154s, some of the CaCO 3 powder were still in the feed window and not entered into the mixing chamber yet. In Figure 7 (e), at process time of 172s, most of the CaCO 3 powder was during the distributing process with the melted LDPE. But some of CaCO 3 powder still didn t mix with the melted LDPE, as indicated by the dashed circles. In Figure 7 (f), at process time of 180s, most of the CaCO 3 powder had been distributed into the melted LDPE. After the process time of 180s, even though the torque and temperature still varied, there were no undistributed CaCO 3 powder left and the mixed polymer melt didn t appear 242 Int. J. Appl. Sci. Eng., 2009. 6, 3

Mixing conditions of polymer and ceramic powder determined by ultrasound to change significantly. This may indicate that, after the process time of 180s, most of the CaCO 3 powder was already mixed with melted LDPE. The ultrasonic signals will be compared with the above results. In Figure 6 (a), at the process time of 32s, the torque value rose up quickly. In Figure 6 (b) and (c), at the process times of 32.4 and 34s, the amplitude of L 1 echo and temperature started to decrease, respectively. The drop in the value of L 1 echo was due to the fact that part of the ultrasonic energy was transmitted into the polymer melt through the probe end/polymer melt interface. The fluctuation of L 1 echo indicated the random contact of soft pellets and molten polymer to the probing end surface. When the torque and temperature value reached to their peak and bottom values, the amplitude of L 1 echo also reached its lower level, but kept fluctuating. According to Figure 7 (b), most of the pellets were still solid with partially melting during this period. The fluctuations of the amplitude of L 1 stopped at the process time of 60s. At the process time of 55s, the ultrasonic echo, reflecting from the polymer melt/flight of the blade interface, started to appear. In the process time from 55 to 84.6s, the peak value of echo fluctuated, indicating the non-uniformity of the melting condition. After the process time of 84.6s, the peak value of echo reached its upper level, indicating that there were no solid or partially melted pellets, and all the LDPE pellets were melted. Figure 7 (c) also supported those diagnosed by ultrasonic technique. Therefore, when the peak value of echo reached its upper stable level, all polymer pellets had completely melted and further heating or rotating may not be necessary. The information of melting completion may be useful to optimize the process. After the feeding of additional 4g CaCO 3 powder, the amplitude of L 1 echo kept at its lower level, but the peak value of echo disappeared due to the undistributed CaCO 3 powder. According to Figure 7 (d), around this period, most of the CaCO 3 powder was still undistributed. At the process time of 171.4s, the ultrasonic echo started to appear again. In the process time from 171.4 to 179.7s, the peak of echo increased monotonically, indicating the progress of mixing condition. After the process time of 179.7s, the peak value of echo reached its upper level again, indicating that there was no undistributed powder and all the CaCO 3 powder was mixed with melted LDPE. Figure 7 (f) also supported those diagnosed by ultrasonic technique. Therefore, when the peak value of echo reached its upper stable level, all CaCO 3 powder had well mixed with the melted LDPE and further heating or rotating may not be necessary. The information of mixing completion may be useful to optimize the process. 4. Conclusions Diagnosis of melting and mixing process in the internal mixer has been performed on-line, non-intrusively and non-destructively. The ultrasonic delay line probe with commercial UT, thermocouple, and torque meter were installed into the mixing chamber of internal mixer. The melting process of 45g LDPE from solid pellets to polymer melt, and the mixing process of the melted LDPE with additional 4g CaCO 3 powder were diagnosed by visual observation, torque, temperature, and ultrasonic signatures. The phase change from solid to melt during melting process, and the distribution of CaCO 3 powder during mixing process can be detected by ultrasonic signatures. The timings of melting and mixing completion can be clearly determined by peak value of ultrasonic echo. Therefore, the presented ultrasonic technique might be an excellent approach to diagnose melting and mixing processes of polymer with powder in the internal mixer nondestructively and noninvasive. Int. J. Appl. Sci. Eng., 2009. 6, 3 243

C. C. Cheng 5. References [ 1] Wang, G.. R. 2003. A rapid mixing process in continuous operation under periodic forcing. Chemical Engineering Science, 58: 4953-4964. [ 2] Tadmor, Z., and Gogos, C. G., 1979. Principles of polymer processing, John Wiley & Sons Inc. [ 3] Tatibouet, J., and Piche, L., 1991. Ultrasonic investigation of semicrystalline polymers: study of poly (ethylene terephthalate). Polymer, Vol. 32, 3147-3153. [ 4] Wang, H., Cao, B., Jen, C. K., Nguyen, K. T., and Viens, M. 1997. On-line ultrasonic monitoring of the injection molding process. Polymer Engineering and Science: 363-376. [ 5] Cheng, C.C., Ono, Y., and Jen, C. K., 2007. Real time diagnosis of co-injection molding using ultrasound. Polymer Engineering and Science: 1491-1499. 244 Int. J. Appl. Sci. Eng., 2009. 6, 3