EVALUATION OF SHEAR TIE CONNECTORS FOR USE IN INSULATED CONCRETE SANDWICH PANELS

Similar documents
AFRL-RX-TY-TP

PERFORMANCE OF STEEL STUD WALLS SUBJECTED TO BLAST LOADS

In-Plane and Out-of-Plane Performance of the MINI-MC Flange Connector

Presentation in support of

Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

FIBER REINFORCED POLYMER (FRP) PANELS FOR BLAST AND FRAGMENTATION MITIGATION

AFRL-RX-TY-TP

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Shear Testing of Precast Concrete Sandwich Wall Panel Composite Shear Connectors

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

CVEN 483. Structural System Overview

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Precast Concrete Bearing Wall Panel Design (Alternative Analysis Method) (Using ACI )

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

GFRP HOLLOW-CORE REBARS FOR CONCRETE BEAMS

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Assessment of Long-Time Behavior for Bridge Girders Retrofitted with Fiber Reinforced Polymer

EFFECT OF VENEER JOINT REINFORCEMENT ON BRICK TIE EMBEDMENT

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS SECTION: PRECAST STRUCTURAL CONCRETE SECTION: SITE CAST CONCRETE

Pile to Slab Bridge Connections

Moment curvature analysis of concrete flexural members confined with CFRP grids

PRECAST REINFORCED CONCRETE SANDWICH PANEL AS AN INDUSTRIALISED BUILDING SYSTEM

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

ANCHOR BOLTS IN CLAY MASONRY WALLS

DEPARTMENT OF THE AIR FORCE HEADQUARTERS AIR FORCE CIVIL ENGINEER SUPPORT AGENCY

Reinforced Concrete Tilt-Up Wall Panel Analysis and Design (ACI 551)

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Precast Wall Panel Design. By Edward Losch, PE, SE

Proposed Modifications to the LRFD Design of U-Beam Bearings

Retrofitting of Reinforced Concrete Beam with Externally Bonded CFRP

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

Static and dynamic testing of bridges and highways using long-gage fiber Bragg grating based strain sensors

Structural Design Guidelines for Concrete Bridge Decks Reinforced With Corrosion- Resistant Reinforcing Bars

Evaluation of the Orientation of 90 and 180 Reinforcing Bar Hooks in Wide Members

Drop weight testing on sandwich panels with a novel thermoplastic core material

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

Appendix D.2. Redundancy Analysis of Prestressed Box Girder Superstructures under Vertical Loads

In-plane testing of precast concrete wall panels with grouted sleeve

Prestressed Concrete Girder Continuity Connection

Investigating Composite Action at Ultimate for Commercial Sandwich Panel Composite Connectors

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

HIGH PERFORMANCE CONCRETE. by John J. Roller CTLGroup

1. INTRODUCTION. (a) Sand/ Fabric-coated (b) Sand-coated deformed. (c) Helical wrapped/ribbed Fig.1 FRP anchors with different outer surfaces

PRECAST CONCRETE CONNECTIONS - US PRACTICE

Yttria Nanoparticle Reinforced Commercially Pure (CP) Titanium

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

STRENGTHENING OF MASONRY WITH NEAR SURFACE MOUNTED FRP BARS. Abstract

research report Performance of Cold-Formed Steel-Framed Shear Walls: Alternative Configurations RESEARCH REPORT RP REVISION 2006

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

MOMENT REDISTRIBUTION IN CONTINUOUS BEAMS OF EARTHQUAKE RESISTANT MULTISTOREY REINFORCED CONCRETE FRAMES

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

ST7008 PRESTRESSED CONCRETE

3.5 Tier 1 Analysis Overview Seismic Shear Forces

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

June 1, 2017 PARTIES INTERESTED IN LOAD BEARING THERMAL BREAK ASSEMBLIES INSTALLED BETWEEN CONCRETE BALCONIES AND CONCRETE FLOORS

North Mountain IMS Medical Office Building

Modelling of RC moment resisting frames with precast-prestressed flooring system

CHAPTER III METHODS AND MATERIALS

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

Laboratory Investigation of Glass Fiber Reinforced Polymer Bridge Slab to Reinforced Concrete Parapet Connection Details

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Ensuring sufficient robustness to resist

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Because of their architectural versatility and energy

Lightweight Steel Framing. Composite DeltaStud Load Tables

Use of Residual Compression in Design to Improve Damage Tolerance in Ti-6Al-4V Aero Engine Blade Dovetails

SEISMIC RESPONSE OF MULTIPLE-ANCHOR CONNECTIONS TO CONCRETE

FRP REBAR: MDOT APPROVED

SECTION REINFORCING STEEL

SECTION MASONRY ACCESSORIES

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

The strength of a material depends on its ability to sustain a load without undue deformation or failure.

Effect of beam dimensions on structural performance of wide beam-column joints

Cyclic Tests of Long Shear Walls with Openings

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

CYCLIC BEHAVIOUR OF SANDWICH CONCRETE BEAM UNDER FLEXURAL LOADING

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

June 22, 2009 PARTIES INTERESTED IN EVALUATION REPORTS ON COMPOSITE COLD-FORMED LIGHT GAGE STEEL AND CONCRETE MASONRY LINTELS

SEISMIC PERFORMANCE AND RETROFIT OF BRIDGE FOOTINGS. David I. McLean 1

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Testing and analysis of masonry arches subjected to impact loads

PrestressedConcreteInvertedTeeBeamswithCFRPforBuildingStructures

RESILIENT INFRASTRUCTURE June 1 4, 2016

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

ME -215 ENGINEERING MATERIALS AND PROCESES

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

Three-Dimensional Material Properties of Composites with S2-Glass Fibers or Ductile Hybrid Fabric

Schöck Isokorb type CV

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

ACCEPTANCE CRITERIA FOR EXPANSION BOLTS IN STRUCTURAL STEEL CONNECTIONS (BLIND-BOLTS) PREFACE

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

Transcription:

AFRL-RX-TY-TR-2009-4600 EVALUATION OF SHEAR TIE CONNECTORS FOR USE IN INSULATED CONCRETE SANDWICH PANELS Clay J. Naito Department of Civil and Environmental Engineering Lehigh University, PA 18015 John M. Hoemann Applied Research Associates P.O. Box 40128 Tyndall Air Force Base, FL 32403 Bryan T. Bewick and Michael I. Hammons Air Force Research Laboratory DECEMBER 2009 Interim Report for 1 January 2009 30 November 2009 DISTRIBUTION STATEMENT A: Approved for public release; distribution unlimited. AIRBASE TECHNOLOGIES DIVISION MATERIALS AND MANUFACTURING DIRECTORATE AIR FORCE RESEARCH LABORATORY AIR FORCE MATERIEL COMMAND 139 BARNES DRIVE, SUITE 2 TYNDALL AIR FORCE BASE, FL 32403-5323

NOTICE AND SIGNATURE PAGE Using Government drawings, specifications, or other data included in this document for any purpose other than Government procurement does not in any way obligate the U.S. Government. The fact that the Government formulated or supplied the drawings, specifications, or other data does not license the holder or any other person or corporation; or convey any rights or permission to manufacture, use, or sell any patented invention that may relate to them. This report was cleared for public release by the Air Force Research Laboratory Airbase Technologies Division Public Affairs Office and is available to the general public, including foreign nationals. Copies may be obtained from the Defense Technical Information Center (DTIC) (http://www.dtic.mil). AFRL-RX-TY-TR-2009-4600 HAS BEEN REVIEWED AND IS APPROVED FOR PUBLICATION IN ACCORDANCE WITH ASSIGNED DISTRIBUTION STATEMENT. //signature// PAUL E. SHEPPARD Work Unit Manager //signature// JOHN S. MASCELLI, Captain, USAF Acting Chief, Force Protection Branch //signature// ALBERT N. RHODES, PhD Acting Chief, Airbase Technologies Division This report is published in the interest of scientific and technical information exchange, and its publication does not constitute the Government s approval or disapproval of its ideas or findings.

REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To) 01-DEC-2009 Interim Technical Report 01-JAN-2009 -- 30-NOV-2009 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Evaluation of Shear Tie Connectors for Use in Insulated Concrete Sandwich Panels 5b. GRANT NUMBER FA4918-07-D-0001 6. AUTHOR(S) +Naito, Clay J.; *Hoemann, John M.; **Bewick, Bryan T., **Michael I. Hammons 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER +Department of Civil and Environmental Engineering, Lehigh University, PA 18015 *Applied Research Associates, P.O. Box 40128, Tyndall AFB, FL 32403 62102F 4915 F2 Q210FA72 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR'S ACRONYM(S) **Air Force Research Laboratory Materials and Manufacturing Directorate Airbase Technologies Division 139 Barnes Drive, Suite 2 Tyndall Air Force Base, FL 32403-5323 12. DISTRIBUTION/AVAILABILITY STATEMENT Distribution Statement A: Approved for public release; distribution unlimited. 13. SUPPLEMENTARY NOTES Ref AFRL/RXQ Public Affairs Case #10-023. Document contains color images. 14. ABSTRACT AFRL/RXQF 11. SPONSOR/MONITOR'S REPORT NUMBER(S) AFRL-RX-TY-TR-2009-4600_ Protection against blast loads has become a high priority for many government agencies. Blast retrofitting and structural hardening, much like earthquake retrofits, can prove to be costly. For this reason, it is important to understand that any structural element has an inherent capacity to absorb energy and provide some level of protection. An evaluation of an existing structure may allow a designer to utilize the full absorption capacity of a structural element, precluding the need for a blast-specific retrofit. To illustrate this concept, the blast resistances of non-load bearing precast/prestressed or tilt-up concrete sandwich wall panels (WP) are examined. These components are used extensively in modern construction for cladding of framed building systems and often provide a significant level of protection from blast events. 15. SUBJECT TERMS sandwich wall panels, prestress wall panels, precast wall panels, tilt-up wall panels, concrete insulted wall systems 16. SECURITY CLASSIFICATION OF: a. REPORT b. ABSTRACT c. THIS PAGE 17. LIMITATION OF ABSTRACT U U U UU 18. NUMBER OF PAGES 37 19a. NAME OF RESPONSIBLE PERSON Paul Sheppard 19b. TELEPHONE NUMBER (Include area code) Reset Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18

Table of Contents Summary... 1 1 Introduction... 2 1.1 Background... 2 1.2 Research Objectives... 3 1.3 Scope... 4 2 Shear Tie Mechanics... 5 2.1 Shear Stress Demands... 5 2.2 Approximate Shear Response of Ties... 6 2.3 Shear Performance Modeling... 8 2.4 Shear Stiffness of Ties... 9 3 Experimental Program... 12 3.1 Shear Tie Descriptions... 12 3.2 Experiment Description... 15 3.3 Test Specimens... 16 3.4 Concrete Strength... 17 4 Experimental Results... 19 4.1 Summary of Results... 19 4.2 Discussion of Results... 20 4.3 Summary Performance... 22 5 Conclusions and Recommendations... 30 5.1 Conclusions... 30 5.2 Recommendations... 30 6 References... 31 i

List of Figures 1. Shear Tie Connections in Sandwich Wall Panel... 2 2. Shear Tie Installation in Foam in Sandwich Wall Panel... 3 3. Shear Flow Free Body Diagrams... 5 4. Backbone Development... 7 5. Multi-linear Approximations... 8 6. Shear Tie Deformation Demands... 9 7. Typical Shear Slip of Exterior and Interior Wythes under Flexural Demands... 10 8. Flexural Panel Response and Relative Shear Slip...11 9. Photographs of Shear Tie Connectors... 14 10. Tie Specimens (Drawn to Scale).... 14 11. Measured Shear Tie Dimensions... 15 12. Testing Configuration... 16 13. Shear Specimen Configuration... 17 14. Estimate Concrete Strength Gain for Group 1 Specimens... 18 15. Summary of Shearing Force - Deformation Performance... 21 16. Tie A - Dayton Delta Tie Measured Shear-Deformation Response... 22 17. Tie B - THERMOMASS Composite Tie Measured Shear-Deformation Response... 23 18. Tie C - THERMOMASS Non-Composite Tie Measured Shear-Deformation Response... 23 19. Tie D1 Altus Group C-Grid (EPS) Measured Shear-Deformation Response... 24 20. Tie D2 Altus Group C-Grid (XPS) Measured Shear-Deformation Response... 24 21. Tie E Universal Building Products Teplo Tie Measured Shear-Deformation Response... 25 22. Tie F Universal Building Products Rockbar Tie Measured Shear-Deformation Response 25 23. Tie G Galvanized Steel C-Clip Tie Measured Shear-Deformation Response... 26 24. Tie H1 Galvanized Steel C-Clip Tie Measured Shear-Deformation Response... 26 25. Tie H2 Stainless Steel C-Clip Tie Shear-Deformation Response... 27 26. Tie I M-Type Tie Shear-Deformation Response... 27 27. Tie J Meadow Burke Truss Girder Shear-Deformation Response... 28 28. Tie K Wire Truss Tie Shear-Deformation Response... 28 29. Tie L Ladur Truss Tie Shear-Deformation Response... 29 ii

List of Tables 1. Backbone Parameters... 7 2. Shear Tie Matrix... 13 3. Summary of Experimental Results... 19 iii

Summary Protection against blast loads has become a high priority for many government agencies. Blast retrofitting and structural hardening can prove to be costly. It is important to understand that any structural element has an inherent capacity to absorb energy and provide some level of protection. An evaluation of an existing structure may allow a designer to utilize the full energy absorption capacity of a structural element precluding the need for a blast-specific retrofit. To illustrate this concept, the blast resistances of non-load bearing precast/prestressed or tilt-up concrete sandwich wall panels were examined. These components are used extensively in modern construction for cladding of framed building systems and often provide a significant level of protection from blast events. To provide resistance against lateral loads, like those generated by wind or blast pressures, sandwich wall panels behave in a composite manner. Shear ties are utilized to achieve a level of composite action between the interior and exterior concrete layers. A variety of shear tie types are used in domestic construction. This study evaluated the performance of shear ties to understand the failure modes of sandwich wall panels conducted on the performance of shear ties. This report provides an in-depth examination of the shearing force - deformation characteristics of ties commonly used in the United States. This data can be used to develop predictive response models for sandwich panels under extreme events in future research. The experimental results indicate that shear ties used in sandwich wall panels have a considerable variation strength, stiffness, and deformability. The maximum shear strength of the connectors average approximately 2,400 lbs with a minimum of 595 lbs and maximum of 6,008 lbs. The connectors varied in their responses from pseudo-rigid-brittle, elastic-brittle, elastic-plastic and plastic-hardening. Tri-linear constitutive relationships were developed for each type of shear connector tested. The ranges of response were divided into three regions: elastic, plastic, and unloading. The elastic stiffness, K, was defined by the slope of the secant to 75% of the ultimate load, V max. The yield displacement, Δ y, was defined at the intercept of the ultimate load and the elastic curve. The ultimate displacement, Δ u, was taken at the point when the strength decreases by 50% of the ultimate. The constitutive relationships developed in this work are recommended for use to model the performance of shear tie-sandwich wall panel systems in a blast event. However, it is important to note that for traditional design, shear tie connectors are used to resist construction-related stresses during handling and placement as well as in-service live loads such as wind loads. Under these demands adequate overdesign is used to ensure that the ties remain in their elastic range. The data generated within this report are applicable in cases where sandwich wall systems are loaded above service conditions, i.e., in a blast event, and should be used accordingly. Consequently, the results generated herein are not recommended to predict sandwich wall system capability under conventional gravity and live load demands. 1

1 Introduction 1.1 Background The information presented in this report represents the second phase of work under a Collaborative Research and Development Agreement (CRADA) between the Portland Cement Association (PCA) and the Air Force Research Laboratory (AFRL), Airbase Technology Division, Tyndall Air Force Base, Force Protection Branch (CRADA 05-119- ML-01). Sample donations have been provided from the Precast/Prestressed Concrete Institute (PCI) and Tilt-up Concrete Association (TCA) with support of their associated member companies. The overall research objective was to assess the inherent blast resistance of conventional concrete products. Conventional concrete products can be further defined as systems that are commercially and readily produced or engineered without any blast considerations/details in their design. In the precast concrete wall industry, a large development thrust has been in green building technology and acquiring Leadership in Energy & Environmental Design (LEED) certification. With these requirements and guidelines the industry has turned to encased insulation to enhance the thermal performance of the building envelope. The insulation is sandwiched between an exterior and interior concrete layer to limit damage of the insulation and to ease construction. Shear ties are used to provide integrity between the interior and exterior concrete sections, referred to as wythes, as illustrated in Figure 1 and Figure 2. The shear ties allow the panels to be lifted and handled during building erection and allow the panels to behave as a composite against flexural demands. Varying the type and arrangement of the shear tie connectors allowed the panels to act as partially to fully composite. Figure 1. Shear Tie Connections in Sandwich Wall Panel 2

Figure 2. Shear Tie Installation in Foam in Sandwich Wall Panel Shear ties are available in a variety of materials and configurations. These include carbon steel, stainless steel, galvanized carbon steel, carbon fiber reinforced polymers (CFRP), glass fiber reinforced polymer (GFRP), and basalt fiber reinforced polymer (BFRP). The various materials are chosen for their cost, thermal, or corrosion resistance benefits. Steel ties are commonly used when thermal and corrosion resistance is not a concern. These connectors are available at the lowest cost. When corrosion resistance is needed stainless steel or galvanized steel can be used at an increased cost. Unfortunately, steel has a high thermal conductivity which results in lower insulation properties for the walls. When high thermal requirements are specified and corrosion is a risk, GFRP, CFRP, or BFRP can be used. Connectors are produced in a variety of configurations including trusses, pins, rods, and grids. From a force-based perspective, the shear capacity of the connectors can be determined either through first principles of engineering or through experimental validation. From a deformation-based perspective the variation in the shear connector configuration results in a range of deformation ability. For example, a FRP truss connector would likely produce a stiff, brittle response while a steel rod would likely result in a flexible response with large ductility. As a consequence the large displacement flexural response of a wall panel can vary significantly based on the type of connector used. To accurately predict the ultimate response of a sandwich panel subject to an increasing lateral pressure, the response of the shear tie connectors must be well defined. Due to the variety of connectors available, a consistent experimental approach was used to quantify and compare the effectiveness of shear ties in this research. 1.2 Research Objectives A series of experiments were conducted on commercially available shear ties for use in precast concrete sandwich wall panels. A validated methodology is needed to predict the 3

ultimate flexural strength of sandwich panels. To accomplish this, the characteristics of the ties used in the panel must be known. The objectives of the research were as follows: 1.3 Scope Quantify the shear strength of tie commercially-available domestic tie connectors for sandwich wall construction. Quantify the shearing force deformation response of each connector type. Develop a simplified backbone response for each connector to facilitate modeling of composite action. For traditional design, shear tie connectors are used to resist construction-related stresses during handling and placement as well as in-service live loads such as wind loads. Under these demands adequate overdesign is used to ensure that the ties remain in their elastic range. The data generated within this report are intended to be applicable in cases where sandwich wall systems are loaded above service conditions, i.e., in a blast event, and must be used accordingly. Consequently, the results generated herein are not recommended for use to predict sandwich wall system capability under conventional gravity and live load demands. 4

2 Shear Tie Mechanics 2.1 Shear Stress Demands The flexural demands placed on sandwich panels produce internal compression, tension, and shear stresses. To support these internal demands as a composite section, the sandwich panel must have adequate tie reinforcement between the interior and exterior concrete wythes. This is accomplished by the placement of shear ties or the use of solid concrete zones between wythes. This study did not considered the solid concrete zone shear transfer mechanism, because the industry is moving away from these designs to ensure greater thermal properties in the wall panel. As illustrated in Figure 3, the flexural demands produce a shear demand perpendicular to the direction of loading. The magnitude of the shear can be computed using three techniques summarized as follows: Method 1 Shear stress is computed from the maximum compression or tension force at the maximum moment region. This method is recommended by PCI [1997]. Method 2 Shear stress is computed from first principles. The derivation of this method is based on the elastic response of the member, thus the assumption is violated once cracking occurs. Method 3 Shear stress is computed from the vertical shear acting on the panel. This method is recommended by American Concrete Institute (ACI) Committee 318 [2005]. C τ1 = max(c,t) Moment b x dl T Shear a) Composite panel with applied load b) Method 1 dl τ2 = VQ Ib C C+ C V V+ V τ3 = C V d = x d b d V T T+ T Shear Stress c) Method 2 b x d) Method 3 Figure 3. Shear Flow Free Body Diagrams While Method 2 and 3 can be used; Method 1 is typically used for the the design of shear reinforcement for concrete sandwich wall panels following the practice of PCI [1997]. The maximum horizontal shear force is computed by taking the minimum of the compression and tension capacity of the section at midspan. The number of ties needed to resist the shear force must be placed on each half of the wall spanning from midspan to the support. To simplify the calculation the assumption is made that the entire exterior wythe is acting in compression. 5

The required shear capacity, V required, can be computed as follows: where V required = min (T, C), [kips] T= Ap sfps + As f C =0.85fc'bt A ps = Area of prestressing steel in tension wythe, [in 2 ] As = Area of non-prestressed steel in tension wythe, [in 2 ] f f ps y f c = Stress in prestressing steel at ultimate flexural strength, [ksi] = Yield stress in non-prestressed steel [ksi] = Concrete compressive strength, [ksi] b = Width of wall panel, [in.] t c = Thickness of compression wythe, [in.] To achieve a fully composite panel response the required number of shear ties, N then be computed using the following relationship: where V tie-capacity Nrequired > V required / V c y tie-capacity = Strength of tie in shear [kips] required, can The strength of the shear ties commercially available in the U.S. are determined in this study and are summarized in section 2.4. 2.2 Approximate Shear Response of Ties A simplified multi-linear curve was developed for each connector to model their response. The backbone curve was based on the average response computed for each connector type. The ranges of response are divided into three regions: elastic, plastic, and unloading. The elastic branch is defined by the secant to 75% of the ultimate load, V max. The yield displacement, Δ y, is defined at the intercept of the ultimate load and the elastic curve. The ultimate displacement, Δ u, is taken at the point when the strength decreases by 50% of the ultimate. The elastic stiffness, K, is tabulated along with the displacement at the ultimate load, Δ m. A schematic of the tri-linear curve development is illustrated in Figure 4. The measured properties from the experiments are summarized in Table 1 and Figure 5. These backbone curves can be used to model the shear response of connectors. 6

Vmax Force Backbone Measured 0.75Vmax 0.50Vmax K e y m u Displacement Figure 4. Backbone Development Table 1. Backbone Parameters Type K [lb/in.] Vmax* [lb] Δe [in.] Δy [in.] Δm [in.] A 95500 2164 0.017 0.023 0.076 B 22243 2675 0.090 0.120 0.326 C 1145 1104 0.723 0.964 1.034 D1 161806 3220 0.015 0.020 0.057 D2 1027099 2966 0.002 0.003 0.009 E 3058 769 0.189 0.251 0.646 F 2926 1737 0.445 0.594 0.529 G 1855 2064 0.834 0.676 0.984 H1 1794 803 0.336 0.448 0.637 H2 33719 1086 0.024 0.032 0.544 I 4304 3847 0.670 0.894 1.178 J 214584 4939 0.017 0.023 0.148 K 26830 2036 0.057 0.076 0.308 L 2320 1593 0.515 0.687 0.825 * Ultimate strength from average response curve ** Displacement at 50% of Vmax not measured 7

2.3 Shear Performance Modeling Figure 5. Multi-linear Approximations For a sandwich panel to behave as a true composite, the ties must have a rigid response under shear. Three of the connectors (D1, D2, and J) exhibited pseudo-rigid response up to an identifiable shear force. If the shear demand exceeds the limit of the rigid response, the ties deform, and the panels are expected to act independently beyond this point. This action is illustrated in Figure 6. As the tie becomes more flexible with progressive damage, the behavior of the panels approaches a non-composite response. The non-composite deformation response can be considered as a stacked plate where each plate is individually deforming with the same shape at the contact surface. Under this condition the shear ties would be subject to zero shear deformation at mid-span and with increasing shear deformation reaching a maximum at the supports. Knowing the relative slip at each connector, the shear demand in each shear tie can be determined from the constitutive relationship illustrated in Figure 5. Thus, the influence of tie stiffness and strength on ultimate panel capacity can be calculated. Further research on this topic is ongoing. 8

3" 12'-0" Outside Face 2" 8" Inside Face Deformed Shape Slip Relative Slip @ Tie x 2.4 Shear Stiffness of Ties Figure 6. Shear Tie Deformation Demands In many cases the stiffness and failure mode of the shear tie can influence the ultimate flexural capacity of a sandwich panel. In a related study [Naito et. al., 2010] a series of sandwich wall panels were subjected to a monotonically increasing uniform load until failure occurred. The flexural response of the panel and the relative shear slip of the interior and exterior wythes were measured as illustrated in Figure 7. A number of different shear ties and reinforcement strategies were examined. 9

Figure 7. Typical Shear Slip of Exterior and Interior Wythes under Flexural Demands The shear response of the ties influenced the shear failure modes of the panels. As an example the results of two experiments are presented in Figure 8. The results include the applied pressure and support rotations for three panels with the same flexural design. The tie type was varied between the panels. Panel PCS4 incorporated a flexible tie, panel PCS5 a moderately stiff tie, and PCS6 a stiff tie. The variation in tie types resulted in a change in the amount of relative slip measured between the wythes and a change in the ultimate capacity of the panels. As illustrated, the load-deformation behavior is sensitive to the tie type used. Between cracking and ultimate capacity, the use of a stiff tie increases the strength of the panel. To properly determine the load deformation response, or resistance function, of a sandwich panel subjected to uniform loads, the connector shear load-deformation characteristics must be known. 10

Pressure [psi] 6 5 4 3 2 1 4B 5A 6A 4B Slip 5A Slip 6A Slip 4 3.5 3 2.5 2 1.5 1 0.5 Slip [in.] 0 0 5 10 15 20 25 Midspan Displacement [in.] 0 1 1 2 " 2'-8" 8" 1'-4" 8" 1'-0" 1'-0" 3/8" Ø Strands @ 14.9 kips 4" (Metal C-Pins) 1 1 2 " 2'-8" 8" 1'-4" 8" 1'-8" 3/8" Ø Strands @ 14.9 kips 6" Thermomass Pin 1 1 2 " 2'-8" 8" 1'-4" 8" 1'-8" 3/8" Ø Strands @ 16.1 kips 6" C-Grid 9" 6" 11 2 " 3/8" Ø Strands @ 14.9 kips Metal C-Pins #3@18" 3" 3" 3" XEPS Insulation Extruded Expanded Polystyrene 9" 6" 11 2 " 3/8" Ø Strands @ 14.9 kips PCS4 PCS5 PCS6 Figure 8. Flexural Panel Response and Relative Shear Slip 3" 3" 3" #3@18" Thermomass CC-180 50-80-50 Pins XEPS Insulation Extruded Expanded Polystyrene 9" 6" 11 2 " 3/8" Ø Strands @ 16.1 kips 3" 3" 3" C-Grid 4.5in. 16 x 10 W2.1 x W3.0 XEPS Insulation (1#) Extruded Expanded Polystyrene 11

3 Experimental Program 3.1 Shear Tie Descriptions Direct shear experiments were conducted on commercially-available connectors from the United States. The research program included both thermally-efficient polymer-based connections and traditional steel connections. The polymer connections included the following: (A) Glass Fiber Reinforced Polymer (GFRP) Delta Tie produced by Dayton Superior; (B) THERMOMASS composite GFRP pins; (C) THERMOMASS non-composite GFRP pins; (D) Altus Group CFRP Grid; (E) Universal Building products GFRP Teplo Tie; and (F) Universal Building products Basalt FRP RockBar. The traditional steel connections included the following: (G) a galvanized steel C-clip by TSA, (H-1) galvanized C-clip produced by Dayton Superior, (H-2) stainless steel C-Clip produced by Dayton Superior, (I) galvanized steel M-Clip, (J) welded wire truss by Meadow Burke, (K) galvanized welded wire truss by Dayton, and (L) galvanized welded wire ladder by Dayton. The overall test matrix is summarized in Table 2. 12

Table 2. Shear Tie Matrix ID Company Tie Type Material A Dayton Delta Tie GFRP Grid B THERMOMASS Composite Tie GFRP Pin C THERMOMASS Non-Composite Tie GFRP Pin 1 D-1 Altus Group C-Grid w/ EPS CFRP Grid D-2 Altus Group C-Grid w/ XPS CFRP Grid E Universal Building TeploTie GFRP Tie Products F Universal Building RockBar Basalt FRP Bar Products G TSA Manufacturing C-Clip Carbon Steel 2 H-1 Dayton Superior C-Clip Galvanized Steel 3 H-2 Dayton Superior C-Clip Stainless Steel I Dayton Superior M-Clip Galvanized Steel J Meadow Burke Welded Wire Girder 1008 Steel K Dayton Superior Single Wythe Truss Hot Dipped Galvanized Steel L Dayton Superior Single Wythe Ladur Hot Dipped Galvanized Steel 1 Two tests conducted. 2 One test conducted. 3 Four tests conducted. The thirteen connectors are illustrated in Figure 9. The connectors as they were configured in each specimen are illustrated in Figure 10. The dimensions of each connector were measured and are reproduced in Figure 11. 13

Figure 9. Photographs of Shear Tie Connectors A B C D E F G H I J K L Figure 10. Tie Specimens (Drawn to Scale). 14

5 5 16 " 1 1 2 " 3 8 " 3 8 " 5 16 " 7" 2" 6" 1 4 " 5 1 4 " 7 1 2 " 6" 6" 6" A B C E F 5" 1 4 " 4" 1 4 " 1 1 2 " G 3" 7 15 16 " 2" H 1 1 2 " 4" 5mm top & bottom I 1" 3 15 16 " J 3 15 16 " 5mm top & bottom 6" 9 gage (3.7mm) 16in. o.c. 6" K Figure 11. Measured Shear Tie Dimensions L 3.2 Experiment Description An experimental fixture was developed to evaluate the shear response of connectors. The loading fixture is illustrated in Figure 12. The specimen contains two connectors to minimize eccentricity and secondary demands on the connection during evaluation. An alternate fixture is specified in ASTM E488 Strength of Anchors in Concrete and Masonry Elements [2003]. The method illustrated in ASTM consists of a connector with a shear load applied directly to the connector. This creates an unrealistic boundary condition and produces prying forces on the connector resulting in a non-conservative measurement of strength. The fixture illustrated in Figure 12 was chosen to more accurately replicate the stresses acting on sandwich wall connectors under large flexural demands. A minimum of three replicate tests were conducted for each connector type unless otherwise noted. Each tie was loaded to failure under a monotonically increasing displacement demand. This demand was used to replicate the conditions that would occur on ties located in a sandwich wall panel under a uniform blast-generated load. Blast pressure demands on walls are characterized by a high intensity dynamic load which exponentially decays over a short duration (typically, less than 100 msec). As a consequence the predominant flexural response of the panel occurs once during the initial positive pressure application. The shear ties are thus subject to the greatest demand once during the inbound cycle and subsequently are loaded to a lesser degree as the panel undergoes free vibration response. The cyclic response was not examined in this study. 15

Figure 12. Testing Configuration The experiments were conducted with a Material Testing System (MTS) closed-loop servocontrolled testing frame. The test frame was operated in displacement control of the MTS actuator. The specimens were examined at quasi-static loading rates. A displacement rate of 0.50 inch per minute was used for specimens A through F. Samples G through L were loaded at 0.25 inch per minute. The applied force was measured using a load cell in line with the MTS actuator. The shear strength tabulated in the report represents the force per connector (half of the load cell reading). The displacement was measured directly on the specimen using a linear variable displacement transducer (LVDT) as illustrated in Figure 12. 3.3 Test Specimens All connectors were tested in a standardized specimen configuration. The tie specimens utilized 2 inches of insulation, which is commonly used in sandwich wall construction. Each specimen was fabricated from concrete with a compressive strength of approximately 4,000 psi at 28 days. The insulation consists of extruded polystyrene (XPS, also known as blue or pink board) in all cases except D1. Because of the low thermal conductivity of the C-grid system Expanded Polystyrene (EPS), also known as bead board, is commonly used for this 16

connector. For completeness the C-grid connection was evaluated with both XPS and EPS insulation. A standard embedment was used on each connector. To fit the connectors within the concrete specimen, 3-inch-thick exterior layers and a 5-inch-thick interior layer was used. The specimen details are illustrated in Figure 13. 1'-6" 1 1 2 " 1'-6" 2" 5" 1'-6" 2" 3" 4 1 2 " 3" 1'-6" 3.4 Concrete Strength Figure 13. Shear Specimen Configuration The specimens were fabricated in four sets. The first consisted of A, B, C, E, F, and G. The second group consisted of H, I, K, and L. The third group consisted of D connectors and the fourth group consisted of J and an addition H detail (H2-4). For the first group the compressive strength of the concrete used in fabrication of the specimens was measured prior to the shear test series and repeated after the series was completed. A concrete strength gain curve was developed in accordance with ACI 209 procedures and was used to estimate the strength of each specimen at time of testing. The strength gain formulation for the first group of tie tests is presented in Figure 14. The compressive strength for these specimen were based on the age of the concrete at the age of testing. The second group of tests was conducted over a period of two days. A compressive strength of 4,056 psi was measured at the time of shear testing in accordance with ASTM C 39 procedures. Group 3 and 4 were tested over a few days. Concrete compression strength tests were conducted in accordance with ASTM C39 following the last shear test. The compressive strength of group 3 was 10,357 psi. The compressive strength of group 4 was 5,081 ± 26 psi. The concrete compressive strength of each test is summarized along with the shear capacities are presented in Section 4. 17

Compressive Strength [psi] 8000 7000 6000 5000 4000 3000 2000 1000 0 ACI 209 Estimate Measured Data 0 20 40 60 80 100 Age [days] Figure 14. Estimate Concrete Strength Gain for Group 1 Specimens 18

4 Experimental Results 4.1 Summary of Results A summary of the measured response of each experiment is presented in this section. The concrete compressive strength at the time of testing, f c, the peak shear strength, corresponding displacement, energy absorbed at the peak load, the average strength and the coefficient of variation on the strength are presented in Table 3. The shear strength measured represents the strength of one connector. The measured force was divided in half to account for the two tie experimental setup. The energy absorbed also represents the performance of one connector. Table 3. Summary of Experimental Results ID Tie Type f c [psi] Peak Shear Strength Corresponding Displacement [in.] Energy Absorbed at 0.2in. Energy Absorbed at peak Average Strength [lbs] [lbs] [lbs-in.] [lbs-in.] A1 GFRP Truss 6680 2632 0.070 340 107 2017 A2 GFRP Truss 6872 2424 0.115 399 220 A3 GFRP Truss 7039 2672 0.014 340 30 B1 GFRP 6680 2748 0.325 346 677 1905 Composite Pin B2 GFRP 6894 2634 0.340 417 774 Composite Pin B3 GFRP 7039 2770 0.387 341 819 Composite Pin C1 GFRP Non- 6680 1119 1.030 104 748 1703 Comp. Pin C2 GFRP Non- 6894 1088 1.034 58 669 Comp. Pin C3 GFRP Non- 7039 907 0.919 56 494 Comp. Pin D11 CFRP Truss 10357 3362 0.054 534 150 3255 (EPS) D21 CFRP Truss 10357 3149 0.066 428 165 (EPS) D12 CFRP Truss 10357 2871 0.007 443 18 2692 (XPS) D22 CFRP Truss 10357 3148 0.009 504 20 (XPS) D32 CFRP Truss 10357 2058 0.433 195 656 (XPS) E1 GFRP Pin 6706 595 0.608 44 258 1924 E2 GFRP Pin 6894 825 0.650 76 408 E3 GFRP Pin 7019 759 1.084 100 698 F1 BFRP Bar 6706 2233 0.556 198 803 2523 F2 BFRP Bar 6894 1435 0.415 172 406 F3 BFRP Bar 7039 1247 0.857 178 917 19

Table 3. Summary of Experimental Results (Concluded) ID Tie Type f c [psi] Peak Shear Strength [lbs] Corresponding Displacement [in.] Energy Absorbed at 0.2in. [lbs-in.] Energy Absorbed at peak [lbs-in.] Average Strength [lbs] G1 Galvanized C- 6706 3831 1.519 99 2775 3407 Clip G2 Galvanized C- 6894 2452 0.661 228 1067 Clip G3 Galvanized C- 7039 3938 1.408 156 3000 Clip H11 Galvanized C- 4056 808 1.014 164 373 NA Clip H21 Stainless C- 4056 944 0.942 114 434 1241 Clip H22 Stainless C- 4056 1085 0.665 135 441 Clip H23 Stainless C- 4056 1356 0.673 193 456 Clip H24 Stainless C- 5110 1579 0.629 164 616 NA Clip I1 M type 4056 4781 1.292 173 3503 4138 I2 M type 4056 3276 1.366 168 1320 I3 M type 4056 4358 1.763 192 4236 J1 Truss Girder 5110 4632 0.039 837 152 5278 J2 Truss Girder 5110 6008 0.066 918 213 J3 Truss Girder 5110 5196 0.020 923 91 K1 Wire Truss 4056 2047 0.472 300 587 2052 K2 Wire Truss 4056 2060 0.429 304 564 K3 Wire Truss 4056 2048 0.447 328 539 L1 Ladder Truss 4056 1580 1.155 60 937 1565 L2 Ladder Truss 4056 1808 0.868 131 940 L3 Ladder Truss 4056 1307 0.710 87 537 4.2 Discussion of Results As illustrated in Table 3 and Figure 15, shear ties used in sandwich wall panels have a considerable variation strength, stiffness, and deformability. The maximum shear strength of the connectors average approximately 2,400 lbs with a minimum of 595 lbs and maximum of 6,008 lbs. The connectors exhibited pseudo-rigid-brittle, elastic-brittle, elastic-plastic, plastic-hardening and a variety of other responses. The variation in shear force-deformation response was directly related to the variability in connector design. The FRP truss type connections (A and D) exhibited an elastic brittle response, because the shear behavior was dominated by FRP in tension. The steel wire truss 20

(K) exhibited an elastic plastic behavior, because the shear behavior was dominated by steel in tension. The steel M-clip (I) and the C-clip with adequate embedment (G) exhibited an elastic-plastic behavior at low shear deformations, because the leg of the connection is subjected to dowel action. As the deformation increased, the connector legs changed to a tension mode resulting in the observed increase in strength. A similar behavior was observed in the steel ladder connection (L); however, a smaller wire diameter caused the forces to be lower. Post-yield hardening did not occur in the standard C-clip details (H) because of the lack of embedment. Post-test inspection revealed that these connections failed due to pullout from the concrete. The FRP non-composite pins (C and E) exhibited an elastic-plastic response with minor hardening. These connections failed by combined flexure-tension demands at the concrete interface. The composite FRP pin (B) produced an elastic-plastic response with high deformation capacity. The failure mode of these connections was dominated by laminar fracture of the connector and a combined flexure-tension mode at the concrete interface. 5000 Shear Force [lbs] 4000 3000 2000 1000 D1 D2 J A A B C D1 D2 E F G H1 H2 I J K L I K B G L F E 0 H2 H1 C 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 15. Summary of Shearing Force - Deformation Performance It is important to note that for traditional design, shear tie connectors are used to resist construction-related stresses during handling and placement as well as in-service live loads such as wind loads. Under these demands adequate overdesign is used to ensure that the ties remain in their elastic range. The data generated within this report are applicable in cases where sandwich wall systems are loaded above service conditions, i.e., in a blast event, and should be used accordingly. Consequently, the results generated herein should not be used to predict sandwich wall system capability under conventional gravity and live load demands. 21

4.3 Summary Performance The measured force displacement response curves for each shear tie type are presented in this section. As noted previously displacements were measured using an external LVDT, and force was measured using the MTS load cell. The response of each test is presented in graphical form. For each connector three test replicates are presented. An average of the three responses is computed for each data set. The average curve is included in each figure. 3000 Shear Force [lbs] 2500 2000 1500 1000 A1 A2 A3 A - Average 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 16. Tie A - Dayton Delta Tie Measured Shear-Deformation Response 22

3000 2500 Shear Force [lbs] 2000 1500 1000 500 B1 B2 B3 B - Average 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 17. Tie B - THERMOMASS Composite Tie Measured Shear-Deformation Response Shear Force [lbs] 3000 2500 2000 1500 1000 C1 C2 C3 C - Average 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 18. Tie C - THERMOMASS Non-Composite Tie Measured Shear-Deformation Response 23

4000 Shear Force [lbs] 3500 3000 2500 2000 1500 C-Grid - EPS1 C-Grid - EPS2 C-Grid - EPS AVG 1000 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 19. Tie D1 Altus Group C-Grid (EPS) Measured Shear-Deformation Response Shear Force [lbs] 4000 3500 3000 2500 2000 1500 C-Grid - XPS1 C-Grid - XPS2 C-Grid - XPS3(damaged) C-Grid - XPS AVG 1000 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 20. Tie D2 Altus Group C-Grid (XPS) Measured Shear-Deformation Response 24

Shear Force [lbs] 3000 2500 2000 1500 1000 E1 E2 E3 E - Average 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 21. Tie E Universal Building Products Teplo Tie Measured Shear-Deformation Response 3000 Shear Force [lbs] 2500 2000 1500 1000 F1 F2 F3 F - Average 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 22. Tie F Universal Building Products Rockbar Tie Measured Shear- Deformation Response 25

Shear Force [lbs] 4000 * 3500 3000 2500 2000 1500 G2 G1 G3 G - Average 1000 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 23. Tie G Galvanized Steel C-Clip Tie Measured Shear-Deformation Response 3000 2500 H-1-1 Shear Force [lbs] 2000 1500 1000 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 24. Tie H1 Galvanized Steel C-Clip Tie Measured Shear-Deformation Response 26

Shear Force [lbs] 3000 2500 2000 1500 1000 H-2-1 H-2-2 H-2-3 H-2-4 H AVG (Stainless C-Clip) 500 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 25. Tie H2 Stainless Steel C-Clip Tie Shear-Deformation Response Shear Force [lbs] 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 I-1 I-2 I-3 I - Average 0 0.00 0.50 1.00 1.50 2.00 Shear Displacement [in.] Figure 26. Tie I M-Type Tie Shear-Deformation Response 27

Shear Force [lbs] 6000 5000 4000 3000 2000 Meadow Burke Truss 1 Meadow Burke Truss 2 Meadow Burke Truss 3 Meadow Burke Truss Average 1000 0 0 0.5 1 1.5 2 Shear Displacement [in.] Figure 27. Tie J Meadow Burke Truss Girder Shear-Deformation Response 3000 K-1 Shear Force [lbs] 2500 2000 1500 1000 K-2 K-3 K - Average 500 0 0.00 0.50 1.00 1.50 2.00 Shear Displacement [in.] Figure 28. Tie K Wire Truss Tie Shear-Deformation Response 28

3000 L-1 Shear Force [lbs] 2500 2000 1500 1000 L-2 L-3 L - Average 500 0 0.00 0.50 1.00 1.50 2.00 Shear Displacement [in.] Figure 29. Tie L Ladur Truss Tie Shear-Deformation Response 29

5 Conclusions and Recommendations 5.1 Conclusions The responses of shear ties used in precast concrete sandwich wall panels were investigated to assess their inherent resistance at loads beyond service loads, a demand typical of a blast event. Domestically available shear tie systems were procured and tested in a shear fixture. The strength, stiffness and deformation capability of these ties were measured. The following conclusions were drawn from this study. Shear ties used in sandwich wall panels vary considerably in strength, stiffness, and deformability. The maximum shear strength of the connectors tested in this study averaged approximately 2,400 lbs with a minimum of 595 lbs and max of 6,008 lbs. Connector responses include pseudo-rigid-brittle, elastic-brittle, elastic-plastic and plastichardening. Tri-linear constitutive relationships were developed for each type of shear connector tested. The ranges of response were divided into three regions: (1) elastic, (2) plastic, and (3) unloading. The elastic stiffness, K, was defined by the slope the secant to 75% of the ultimate load, V max. The yield displacement, Δ y, was defined at the intercept of the ultimate load and the elastic curve. The ultimate displacement, Δ u, was taken at the point when the strength decreases by 50% of the ultimate. These relationships can be used to. 5.2 Recommendations The constitutive relationships developed in this work are recommended for use to model the performance of shear tie-sandwich wall panel systems in a blast event. However, it is important to note that for traditional design, shear tie connectors are used to resist construction-related stresses during handling and placement as well as in-service live loads such as wind loads. Under these demands adequate overdesign is used to ensure that the ties remain in their elastic range. The data generated within this report are applicable in cases where sandwich wall systems are loaded above service conditions, i.e., in a blast event, and should be used accordingly. Consequently, the results generated herein are not recommended to predict sandwich wall system capability under conventional gravity and live load demands. Experimental validation of these relationships is recommended using full-scale blast experiments. 30

6 References ACI Committee 209, Prediction of Creep, Shrinkage, and Temperature Effects in Concrete Structures, ACI 209-92, American Concrete Institute, 1997. ACI Committee 318, Building Code Requirements for Structural Concrete, ACI 318-05, 2005. ASTM Standard C39, 2005, Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens, ASTM International, West Conshohocken, PA, 2005, DOI: 10.1520/C0039_C0039M-05E01, www.astm.org. ASTM Standard E488, 2003, "Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements," ASTM International, West Conshohocken, PA, 2003, DOI: 10.1520/E0488-96R03, www.astm.org. PCI Committee on Precast Sandwich Wall Panels, State-of-the-Art Report of Precast/Prestressed Sandwich Wall Panels, PCI Journal, Vol.42, No.2, March-April, 1997. Naito, C., Hoemann, J., Salim, H., Saucier, A., Shull, J., and Bewick, B., Precast/Prestressed Concrete Experiments Performance of Non-Load Bearing Sandwich Wall Panels, To be submitted to AFRL in Spring 2010. 31