PERFORMANCE BASED EVALUATION OF FIRE SCENARIOS USING FLUENT

Similar documents
Numerical Modelling of Air Distribution in the Natatorium Supported by the Experiment

The Suitability of Fire-Field Modelling for Enclosure Fires involving Complex Solid Fuel Loads. STIFF Meeting Sept 2006 Stuart Winter

P. Rohdin 1, M. Johansson 2, J. Löfberg 3, M. Ottosson 4. Abstract

Computer Models For Fire and Smoke

Heat Transfer Augmentation of Air Cooled Internal Combustion Engine Using Fins through Numerical Techniques

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Effect of Rotation Speed of a Rotary Thermal Wheel on Ventilation Supply Rates of Wind Tower System

Validation of Numerical Modeling of Air Infiltration through Building Entrance Doors

Experimental Evaluation of LPG Release and Dispersion in the Enclosed Car Parks

A STUDY OF CROSS CONTAMINATION OF IN-SUITE VENTILATION SYSTEMS USED IN MULTI-UNIT RESIDENTIAL BUILDINGS

IDENTIFICATION OF VENTILATION PROBLEMS IN AN UNDERGROUND BUS TERMINAL IN KOREA

DISPLACEMENT VENTILATION

Postprint.

Fire Engineering, the BCA (NCC) & Bushfire Calculator. Keith Nicholls - Manager Product Testing and Assessments (Australia) Exova Group Limited

Passive Heat Removal System Testing Supporting the Modular HTGR Safety Basis

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

2010 STAR European Conference: 22 & 23 March, London, UK

Modelling Approaches for Displacement Ventilation in Offices

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

Quenching steels with gas jet arrays

These systems are offered an alternative to overhead, mixing ventilation (MV), systems. Due to their potential advantages which are [1]:

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

FSI ANALYSIS OF TRAILING EDGE REGION COOLING IN HP STAGE TURBINE BLADE

PLUME ANALYSIS AND CFD MODELING FOR EFFECTIVE EAF MELTSHOP ENVIRONMENT CONTROL

Task 1 For Task 1, the outlet was set as a zero-gauge pressure outlet, which is the same outlet condition as the five smaller pipes.

Numerical Investigation of the Flow Dynamics of a Supersonic Fluid Ejector

Corridor Pressurization System Performance in Multi-Unit Residential Buildings

ESTIMATION OF THE GAS EXHAUST RATE REQUIRED ON AN ALUMINIUM REDUCTION CELL DURING START-UP USING TASCflow3D

NOTE: Some guidance on a performance approach to natural ventilation systems design is provided in the Supplement to this Standard.

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

A BASIC IMMERSION FIRETUBE FLOWNEX MODEL

MSC Guidelines for Review of Ventilation System Plans

2012 IRC Sections R303 R310 Building Planning II

MODELLING THE URBAN MICROCLIMATE AND ITS INFLUENCE ON BUILDING ENERGY DEMANDS OF AN URBAN NEIGHBOURHOOD

AN APPLICATION OF BUILDING SIMULATION TECHNIQUES TO THE ASSESSMENT OF NATURAL VENTILATION IN OFFICE WITH DOUBLE SKIN FACADE

COOLING EFFECT ENHANCEMENT IN MAGNETRON SPUTTERING SYSTEM

Design of Ventilation for a Highway Tunnel in a Very Crowded Urban Area

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

F111 Methanol Fuel Cell J103 Junior DMFC

CFD modelling of fire development in metro carriages under different ventilation conditions

Environmental Testing of an Advanced Flare Tip for a Low-Profile Flare Burning Ethylene

MEP's Letter of Assurance

AIRFLOW WINDOW: NUMERICAL STUDY AND SENSIBILITY ANALYSIS OF THERMAL PERFORMANCES. *Corresponding author:

MEP Engineer's Letter of Assurance

Thermal Analysis of Automotive Head Lamp Using CFD Analysis

TEMPERATURE RESPONSE OF A RAIL-CASK-SIZE PIPE CALORIMETER IN LARGE-SCALE POOL FIRES

Evaluation of efficiency and collector time constant of a solar flat plate collector

Selection of Glass and its effect on Heat Load Estimation

ANNUAL OF NAVIGATION 13/2008

MODELLING OF HYDROGEN JET FIRES USING CFD

Numerical Investigation of the Integration of Heat Transfer Devices into Wind Towers

PERFORMANCE ANALYSIS OF NATURAL DRAFT WET COOLING TOWER AT OPTIMIZED INJECTION HEIGHT

Building & Ductwork Airtightness Standards

Latest Simulation Technologies for Improving Reliability of Electric Power Systems

THE STUDY OF THE BAKING OVENS BY COMPUTER SIMULATION

Performance and Optimization of Annular Fins by Using Finite Element Analysis

Theory Comparison between Propane and Methane Combustion inside the Furnace

Jet Tunnel Fans.

Abstract. Nomenclature. A Porosity function for momentum equations L Latent heat of melting (J/Kg) c Specific heat (J/kg-K) s Liquid fraction

Feasibility study of a roof top Solar room heater

Use of CFD in the Performance-Based Design for Fire Safety in the Oil and Gas Sector

Optimization of embedded Heat Exchanger in a flat plate Integrated Collector Storage Solar Water Heater (ICSSWH), with indirect heat withdrawal.

Dangerous Goods (Storage and Handling) Regulations 2000 and Code of Practice

Strategies and Intervention tactics - FC stationary installations

Simulating Thermal Balance of Electronics an AcuSolve approach

Heat transfer modelling of slot jet impinging on an inclined plate

Analysis of Side Sluice in Trapezoidal Channel

VEHICULAR TUNNEL VENTILATION DESIGN AND APPLICATION OF CFD

ARCHIVES OF CIVIL ENGINEERING, LX, 1, 2014 NUMERICAL INVESTIGATIONS OF EFFECT OF INDOOR AIR QUALITY ON THERMAL COMFORT IN RESIDENTIAL BUILDINGS

Performance Analysis for Natural Draught Cooling Tower & Chimney through Numerical Simulation

Thermal Management of Densely-packed EV Battery Set

Assignment I Design of a Marine Outfall

Advanced Ventilation for Residential applications FBC Res 2010.

ENERGY SAVING IN BUILDING USING PCM IN WINDOWS

Heat Transfer in Laser Tumor Excision

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

Information Delivery Manual (IDM)

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Numerical simulation of upward flame spread over vertical combustible surface

125BEPM - Building energy performance modeling. Lecture handouts

A NEW APPARATUS FOR FLAME SPREAD EXPERIMENTS

Live Transportation Research and Improvement Initiatives

Numerical Modelling of Coal Combustion Processes in the Vortex Furnace with Dual-Port Loading

GENERAL SITING REQUIREMENTS FOR SINGLE DWELLINGS/OUTBUILDINGS

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

The Potential for Electromagnetic Metal Forming for Plane (Car Body) Components

THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS

Application of CFD for Analyzing Quenching and Quench System Design. Andrew L. Banka

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

EVALUATION OF THE THERMAL PERFORMANCE OF FIVE REFRIGERATED VANS

Pembina Nisku Oil Project. Three Well Exploration Program

Neil Eccles June SBED TSC Technology

PS Modeling airflow in outdoor grain pile aeration systems. Introduction

BACK TO BASICS: DUCT DESIGN. Matthew Low, M.AIRAH, CPEng 15 MAY 2013

ASTATT1 Prepare to carry out air tightness testing

Designing Low Impact Wastewater Discharge from Solar Distillation Site to Sea

Modeling of Residual Stresses in a Butt-welded Joint with Experimental Validation

Great Ocean Rd Ice Creamery

Transcription:

PERFORMANCE BASED EVALUATION OF FIRE SCENARIOS USING FLUENT Shyam Dayanandan, Dan Chong Computational Engineering Solutions LLP E-mail: shyam@ce-sol.com Website: www.ce-sol.com ABSTRACT The Fire and Engineering Codes prescribe many requirements to ensure the safety of occupants and facilitate fire fighting. Often times cost and structural limitations cause civil and M&E designs to deviate from these prescriptions. This paper presents a brief account of 2 case studies where CFD (Fluent) is used to assure Fire Safety and Shelters Department that although there is deviation from the prescription in these specific instances, the alternative solutions adequately meets safety requirements. Keywords: Performance Based Evaluation, Smoke Spread, Visibility, Radiation Heat Flux

1. INTRODUCTION In Singapore, the code of practice provides general guidance in facility and mechanical ventilation system designs. Often times cost and structural or space limitations cause civil and M&E designs to deviate from these prescriptions. This paper presents 2 instances where the desire for efficiency and space limitations bring about a deviation from the guidelines prescribed in the codes of practice. In these instances, the designs are submitted to authorities as a Performance Based Design. In these instances, the design has to be accompanied by rigorous Computational Fluid Dynamics (CFD), to substantiate that the level of safety and function that the prescriptive designs hopes to achieve, are also met by the performance based designs. The 2 instances are as follows: Ductless Jet Fan Mechanical Ventilation System The main purpose of mechanical ventilation systems for an enclosure in a fire situation is to achieve acceptable level of fire safety requirements within the enclosure. Most importantly, the high temperatures and lack of visibility (due to smoke spread) within the enclosure does not hinder the fire fighting operations by the fire brigade. Before the introduction of Ductless Jet Fan mechanical ventilation system, the conventional mechanical ventilation system for carparks consist of the main exhaust fans and/or main supply fans with its dedicated network of exhaust air duct work and supply air duct work. The high static losses in the duct work require high power consumption by the main exhaust fans and/or main supply fans. Furthermore, the duct work takes up a lot of valuable space and makes the task of coordinating the building services (e.g. fire protection system, air-conditioning and mechanical ventilation system, electrical system, sanitary & plumbing system, etc) more difficult. The use of Ductless Jet Fan mechanical ventilation system as an alternative solution to the conventional mechanical ventilation system for carparks has grown in popularity as it has addressed the system constraints posed by the conventional mechanical ventilation systems. The Ductless Jet Fan mechanical system for carparks consist of main exhaust fans and/or main supply fans with a series of jet fans strategically located to transport air from one location to another, with the strategy of moving the air from the main supply air fans or supply air permanent openings to the main exhaust air fans. The use of Ductless Jet Fan MV system must be accompanied by rigorous CFD to substantiate that the level of safety and function provided by prescriptive designs are met. The criteria to ensure acceptability is as follows; after 20mins of the onset of the fire, the region in the carpark where the visibility is below 5m must be kept to an area within 1000m 2 and the temperature in the carpark (except at the immediate vicinity of the fire) must be kept below 250 o C. Petrol Station Boundary Line The boundary line / fence of the petrol station must be a prescribed distance away from the nearest petrol dispenser. This offset distance is calculated based on the natural opening area of the petrol station. For a typical petrol station the offset distance is about 15m. However, for a large majority of petrol stations in Singapore, the lack of space forces the placement of petrol dispensers at a distance much less than 15m from the boundary fence. This is of great concern because in the event of a fire in the petrol station the extreme radiation flux from the fire might ignite items in the adjacent property and

cause the fire to spread. So the shorter the offset distance the greater the concern for authorities. From research done by V Babrauskas [1], the Radiation flux required to ignite an item is about 20kW/m 2. Therefore, rigorous CFD studies must be preformed to ensure that although the minimum required offset distance is not met, the Radiation Flux at the offset boundary is well below the amount required for ignition. 2. CASE STUDIES 2.1 Ductless Jet Fan Mechanical Ventilation System for Residential Carpark 2.1.1 Problem Description The floor area of the car park is about 9550m 2 and has 55 ductless Jet fans (see Fig. 1). About 386820cmh of Fresh Air is supplied and 386820cmh of air is extracted for emergency mode (in the event of a Fire). The objective of the CFD Fire Simulation study is to predict the flow field, visibility and temperature distribution in the carpark. The flow field, visibility and temperature will be analyzed at average human head level (1.7m from the floor). In this study, fire size is 4MW and the fire was modelled by the volumetric heat and smoke release source. Combustion modelling is not used to simulate the fire due to associated numerical instabilities and computational demands. However, the use of a volumetric source model only marginally compromises accuracy, as presented by Saha et. al. [2]. Upon the onset of the fire, it is assumed that the sensors will take 2mins to detect the fire. So after 2mins, the mains fans will switch from normal operation to emergency mode operation. Therefore, the CFD fire simulation strategy is as follows; the transient simulation will be marched in time for 2mins with the fans at low flow and then for a further 18mins with the fans at high flow. The results are analyzed at 20mins after the start of the fire.

2.1.2 Results and Discussion Fig. 1: Computational Grid of Carpark Fig. 2: Velocity Contour at 1.7 Height 20mins after Start of Fire

Fig. 3: Visibility Contour at 1.7 Height 20mins after Start of Fire Fig. 4: Temperature Contour at 1.7 Height 20mins after Start of Fire Velocity Profile The velocity profile shows velocities more than 0.4m/s. There seems to be hardly any regions of stagnation or regions where the Mean Age of Air is high. Visibility Profile For fire fighting purposes, the critical limit for visibility is 5m (i.e. the visibility should be more than 5m). For the 4MW Fire, the region where the visibility is more than the critical limit is only a small region around the fire (indicated in red in the contour plots). The visibility in the large majority of carpark ranges from perfectly visible to about 13m in visibility. For immediate regions surrounding the fire (see Fig.3) the visibility is about 9m. So the ventilation system seems to be able to keep the visibility within acceptable limits in the carpark.

Temperature Profile For fire fighting purposes, the critical limit for temperature is 250 o C (i.e. the temperature should be less than 250 o C). For the 4MW Fire, the region where the temperature is more than the critical limit is only a small region around the fire (indicated in red in the contour plots). The temperature in the large majority of Zone 1 is from 30 o C to about 85 o C. For immediate regions surrounding the fire (see Fig.4) the temperature is about 160 o C. So the ventilation system seems to be able to keep the temperature in the carpark within acceptable limits. The results indicate that the strategic placement of the jet fans is adequate to maintain conditions necessary for the fire fighters. In the event that the jet fan placement is not adequate, the quantity and/or location and orientation of the jet fans must be modified and subsequent CFD simulations must be performed to establish performance. 2.2 Petrol Station with Offset Distance of Only 6m 2.2.1 Problem Description The petrol station considered has an offset distance of 6m from the boundary fence to the nearest petrol dispenser. This is way below the prescribed minimum of 15m for this petrol station. From Fig. 5, it can be seen that there are two dispensers nearest to the boundary line. Therefore, the worst possible case of two 5MW truck fires (one at each dispenser) is considered for the simulation. Of the two 5MW fires simulated for this study, 30% of the heat energy is assumed to be transmitted by radiation and 70% by conduction and convection. For this CFD simulation, the P-1 radiation model is used to model the Radiation flux. To add conservativeness to the results, all surfaces are prescribed to provide a reflection of 10% of the incident radiation and the absorption and scattering within the medium (air and smoke) is not considered. The Radiation Flux is monitored at 9 points just after the boundary fence, as shown is Fig. 6. 2.2.2 Results and Discussion Fig. 5: Computational Grid of Petrol Station

Fig. 6: 9 Sampling Data Points just after Boundary Fence Fig. 7: Radiation Flux Contour Plot on Vertical Plane between the 2 Fire Points

Fig. 8: Radiation Flux Contour Plot on Vertical Plane Along the Outside of Boundary Fence Points 1 2 3 4 5 6 7 8 9 Radiation Flux (W/m 2 ) 3236 3326 3267 3460 3556 3500 3210 3311 3243 Table 1: Radiation Flux at 9 Points along the Boundary Plane Radiation Flux The Radiation flux at the offset boundary is predicted to reach a maximum of about 3600W/m 2. The above predictions are probably over-predicted since the absorption coefficient and scattering coefficient of air and smoke (from the fires) are not taken into account. The Radiation flux of 3.6kW/m 2 is way below 20kW/m 2 required to cause ignition, as presented by V Babrauskas [1]. Thus, although the offset distance of 6m is way below the prescribed minimum of 15m for this particular petrol station, the CFD analysis shows that the Radiation flux at the boundary is well within safe limits. 3. CONCLUSION The CFD studies conducted assures the Fire Safety and Shelters Department that although there is deviation from the prescription in these specific instances, the alternative solutions adequately meets safety requirements. Therefore CFD allow engineers to design and implement efficient solutions, while ensuring that safety is not compromised.

4. REFERENCES 1. S. Saha, S. Bandyopadhyay and S. Sarkar, Fluent CFD Conference, Numerical Study of Flow Induced by Fire in a Compartment. Fluent India, Pune 2003. 2. V. Babrauskas, Will the Second Item Ignite?, NBSIR 81-2271, Center for Fire Research, National Engineering Laboratory, US Department of Commerce, National Bureau of Standards, May 1981