Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Similar documents
Operations Manual. For Research Use Only. PH: EM: WEB:

For Safe and Delicious Water

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Using the PPM2 Portable Trace Moisture Transmitter

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Model FDL 115 Safety drying chambers for limited quantities of solvent

GAS 3050P NDIR FLUE GAS

INSTRUCTION MANUAL FOR USE AND MAINTENANCE

Reliable, low-maintenance process heating

Ray s top tips: Things to consider when buying an Autoclave:

Technical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply.

Aqua-Recycling-Control 80B Plus

Water Softener softliq:mc. Intended use. Function. Design

STERIVAP HP. Large Steam Sterilizer for Health Care for Original Without Compromises. protecting human health

xdental x the sterilization company Domina Plus B Aptica Plus B Atoma Plus

b) General instructions and documents to be submitted by an interested company:

>> OUR ALL-IN-ONE AUTOCLAVE <<

Model BF 720 Incubators Avantgarde.Line with forced convection

A UT OCL A VE VE OCLA UT A _AutoClave_D1102EN_1703.indd /03/01 13:45

Pioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS

PURELAB CHORUS SYSTEMS

NCE Energy saving circulating pumps

CYTOPERM 2 CO 2 - AND CO 2

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

arium mini Ultrapure Water System

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

Polaris VCD. Efficient and Effective WFI Solutions WATER TECHNOLOGIES

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

Model BF 260 Incubators Avantgarde.Line with forced convection

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Farayand. Subject : Introduce Systec company and autoclave. Presented by : Vahid Totonchi. Mehr 1393

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

The Premium-Plus-Class Now even better. Up to 9 kg of instruments!

Sterilization. Euronda Spa t (+39) m euronda.com

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

If you think vertical sterilizers are all the same, have a look at what we have done: the new FVA /A1 FEDEGARI AUTOCLAVI SPA

Operating Manual. MELAquick 12+

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Sirona competency in hygiene DAC PROFESSIONAL. Hygiene systems. Vacuum autoclave class B to satisfy the most demanding requirements

Compact flue gas analyser: testo 300 M-I

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.

UNISTERI HP. Medium-sized Steam Sterilizer for Health Care - Efficient, Intelligent, Exceptional. protecting human health

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

Sterilization & Infection Control Products

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

Fast. Easy to use. Secure traceability.

Cominox range. Pure sterilization

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

Tuchenhagen. Product Recovery Systems

1/58 Components of solar systems

Sterifix RELIABLE TECHNOLOGY FOR thermal wastewater

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 160 / 25 to 40 bar / 37 to 160 kw

Humidity/temperature measuring instrument

PORTABLE FLUE GAS ANALYZER

Multi-function VAC measuring instrument

Hydrogen Generators. for GC combustion detector applications. Product Features: Contact Information: ENGINEERING YOUR SUCCESS.

Safe production with clean water. active Water treatment

PLUS TEMPERATURE CONTROL SYSTEMS FOR THE CHEMICAL, PHARMACEUTICAL AND PLASTICS INDUSTRIES

Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization

Technical System Catalogue Modular PDU (PSM)

ElectroChemTM Advanced EDR

HEATMAX. Mechanical Installation and Commissioning Instructions HEATMAX

Autoclaves & Sterilizers

New Measurement Engineering For Monitoring Emissions In Industry

Fpollutant-free zero air for analytical

All boilers with touch screens. Log Wood

MEDICAL TRADING knows the meaning of sterilization very well: it can be

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Audion Medical. Impulse & vacuum Rotary sealers Heat sealer Packaging standards Measuring devices

Nilan VPL Active heat recovery and cooling (air/air)

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

Low Temperature Testers

Process Inline Filter, Change-Over

BSL3 and BSL4 Autoclaves. Laboratory Line

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit

High Speed... Rapid Temperature Change Rates with VTS & VCS Stress Screening Systems

Systec Laboratory Autoclaves

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Steam Sterilizers. DLOV & DLOM series. more than sixty years of experience in sterilization. DE LAMA s Quality Management System is certified:

Thermoformer. know-how packaging

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 01

PRECAST RECTANGULAR CHAMBERS

Pump down time for 5 l receiver

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

series HSD Steam sterilizer EUROSTEAM Medical device

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

TECHNICAL SPECIFICATION

VERTICAL AUTOCLAVE DELUXE. MODEL NO.- Acm A

F2 15/30 SIP PILOT SCALE BIOREACTORS

AQUAROBIC MINI-PLANT TM

CaseMaster. multipurpose Sealed Quench chamber furnaces

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

Operation and Maintenance of Electrochlorination Plant

RapID Raw Materials Verification System

64C Amplification Block. Instruction Manual

Transcription:

Laboklav Dampfsterilisatoren Steam sterilizers Type 55 to 195 Liter Technical Datasheet Edition 07/2008

SHP Steriltechnik AG Gustav-Ricker-Str. 62 D-39120 Magdeburg Tel: +49 (0) 391 626988-0 Fax: +49 (0) 391 626988-1 E-Mail: info@shp-steriltechnik.de Internet: www.shp-steriltechnik.de

Steam sterilizer Laboklav 55-195 Technical Datasheet 3 Content page I. Technical Data Laboklav 55-195...4 II. Product characteristics Laboklav 55 195...10 III. Ambient conditions for Laboklav 55 195...11 IV. Consuption data Laboklav 55 195...11 V. Media supply Laboklav 55 195...12 VII. Installation dimensions...13 VIII. Connections...14

4 Technical Datasheet steam sterilizer Laboklav 55-195 I. Technical Data Laboklav 55-195 Laboklav 55 Overall dimension (free standing unit)(w x H x D)... Footprint (Bench top unit)(w x D).. 740 x 765 x 600 mm 740 x 670 mm Weight (net)...... ca. 125 kg Volume Feed water tank... Maximum Load: Sterilizer chamber: ca. 16 l - Instruments... 20 kg - Textiles... 10 kg - Liquids..... 15 Liter Total volume Total volume.... Chamber dimension ( x D)... usable Volume... Maximum allowable pressure (PS)... ca. 62 l 410 x 460 (+50-round.) mm ca. 60 l Maximum allowable temperature (TS)... 143 C Working pressure safety valve... Material number for chamber and double jacket... 1.4404 (SS 316 L) Surface roughness... 0,8 µm Pressure Device Directive 97/23/EG... Power supply: Voltage... Working power... Averaged power consumption per cycle... Protection class...... Protection level....... CE0036, Kat. I, Module A1 3N 400V~ ( 5%), 50 Hz, 16A 4,5 kw 5 kwh I IP24 Water supply: Destilled or demineralized Water (acc. to annex C EN 13060:2004) Averaged feed water consumption per cycle... ca. 3,5 l Storing conditions: Temperature... 5 40 C Humidity... max. 85% Programs: 10 predefined Programs in user level 1: The program definition depends on the available options included in the model. The programs can be individually changed. 10 programs in user level 2 (Program P11 to P20) Code protected. Predefinition is like P1. 2 test programs (Bowie&Dick-Test, P11, vacuum test, P12) in vacuum versions only Computer interface: - serial interface RS 485 Printer (optional)

Steam sterilizer Laboklav 55-195 Technical Datasheet 5 Laboklav 80 Overall dimension (free standing unit)(w x H x D)... Footprint (Bench top unit)(w x D).. 740 x 915 x 600 mm 740 x 820 mm Weight (net)...... ca. 165 kg Volume Feed water tank... Maximum Load: Sterilizer chamber: ca. 30 l - Instruments... 30 kg - Textiles... 10 kg - Liquids..... 21 Liter Total volume Total volume.... Chamber dimension ( x D)... usable Volume... Maximum allowable pressure (PS)... ca. 82 l 410 x 610 (+50-round.) mm ca. 80 l Maximum allowable temperature (TS)... 143 C Working pressure safety valve... Material number for chamber and double jacket... 1.4404 (SS 316 L) Surface roughness... 0,8 µm Pressure Device Directive 97/23/EG... Power supply: Voltage... Working power... Averaged power consumption per cycle... Protection class...... Protection level....... Water supply: Destilled or demineralized Water (acc. to annex C EN 13060:2004) Averaged feed water consumption per cycle... CE 0036, Kat. II, Module A1 3N 400V~ ( 5%), 50 Hz, 16A 4,5 kw 5 kwh I IP24 ca. 3,5 l Storing conditions: Temperature... 5 40 C Humidity... max. 85% Programs: 10 predefined Programs in user level 1: The program definition depends on the available options included in the model. The programs can be individually changed. 10 programs in user level 2 (Program P11 to P20) Code protected. Predefinition is like P1. 2 test programs (Bowie&Dick-Test, P11, vacuum test, P12) in vacuum versions only Computer interface: - serial interface RS 485 Printer (optional)

6 Technical Datasheet steam sterilizer Laboklav 55-195 Laboklav 100 Overall dimension (free standing unit)(w x H x D)... Footprint (Bench top unit)(w x D).. 740 x 1065 x 600 mm 740 x 970 mm Weight (net)...... ca. 195 kg Volume Feed water tank... Maximum Load: Sterilizer chamber: ca. 30 l - Instruments... 40 kg - Textiles... 25 kg - Liquids..... 30 Liter Total volume Total volume.... Chamber dimension ( x D)... usable Volume... Maximum allowable pressure (PS)... ca. 102 l 410 x 760 (+50-round.) mm ca. 100 l Maximum allowable temperature (TS)... 143 C Working pressure safety valve... Material number for chamber and double jacket... 1.4404 (SS 316 L) Surface roughness... 0,8 µm Pressure Device Directive 97/23/EG... Power supply: Voltage... Working power... Averaged power consumption per cycle... Protection class...... Protection level....... Water supply: Destilled or demineralized Water (acc. to annex C EN 13060:2004) Averaged feed water consumption per cycle... CE 0036, Kat. II, Module A1 3N 400V~ ( 5%), 50 Hz, 16A 6,5 kw 6,5 kwh I IP24 ca. 3,5 l Storing conditions: Temperature... 5 40 C Humidity... max. 85% Programs: 10 predefined Programs in user level 1: The program definition depends on the available options included in the model. The programs can be individually changed. 10 programs in user level 2 (Program P11 to P20) Code protected. Predefinition is like P1. 2 test programs (Bowie&Dick-Test, P11, vacuum test, P12) in vacuum versions only Computer interface: - serial interface RS 485 Printer (optional)

Steam sterilizer Laboklav 55-195 Technical Datasheet 7 Laboklav 135 Overall dimension (free standing unit)(w x H x D)... Footprint (Bench top unit)(w x D).. 840 x 965 x 700 mm 840 x 870 mm Weight (net)...... ca. 205 kg Volume Feed water tank... Maximum Load: Sterilizer chamber: ca. 40 l - Instruments... 40 kg - Textiles... 25 kg - Liquids..... 30 Liter Total volume Total volume.... Chamber dimension ( x D)... usable Volume... Maximum allowable pressure (PS)... ca. 135 l 500 x 660 (+50-round.) mm ca. 130 l Maximum allowable temperature (TS)... 143 C Working pressure safety valve... Material number for chamber and double jacket... 1.4404 (SS 316 L) Surface roughness... 0,8 µm Pressure Device Directive 97/23/EG... Power supply: Voltage... Working power... Averaged power consumption per cycle... Protection class...... Protection level....... Water supply: Distilled or demineralised Water (acc. to annex C EN 13060:2004) Averaged feed water consumption per cycle... CE 0036, Kat. II, Module A1 3N 400V~ ( 5%), 50 Hz, 16A 6,5 kw 6,5 kwh I IP24 ca. 5,5 l Storing conditions: Temperature... 5 40 C Humidity... max. 85% Programs: 10 predefined Programs in user level 1: The program definition depends on the available options included in the model. The programs can be individually changed. 10 programs in user level 2 (Program P11 to P20) Code protected. Predefinition is like P1. 2 test programs (Bowie&Dick-Test, P11, vacuum test, P12) in vacuum versions only Computer interface: - serial interface RS 485 Printer (optional)

8 Technical Datasheet steam sterilizer Laboklav 55-195 Laboklav 160 Overall dimension (free standing unit)(w x H x D)... Footprint (Bench top unit)(w x D).. 840 x 1065 x 700 mm 840 x 975 mm Weight (net)...... ca. 220 kg Volume Feed water tank... Maximum Load: Sterilizer chamber: ca. 40 l - Instruments... 40 kg - Textiles... 25 kg - Liquids..... 45 Liter Total volume Total volume.... Chamber dimension ( x D)... usable Volume... Maximum allowable pressure (PS)... ca. 165 l 500 x 760 (+50-round.) mm ca. 163 l Maximum allowable temperature (TS)... 143 C Working pressure safety valve... Material number for chamber and double jacket... 1.4404 (SS 316 L) Surface roughness... 0,8 µm Pressure Device Directive 97/23/EG... Power supply: Voltage... Working power... Averaged power consumption per cycle... Protection class...... Protection level....... Water supply: Destilled or demineralized Water (acc. to annex C EN 13060:2004) Averaged feed water consumption per cycle... CE 0036, Kat. II, Module A1 3N 400V~ ( 5%), 50 Hz, 16A 6,5 kw 6,5 kwh I IP24 ca. 5,5 l Storing conditions: Temperature... 5 40 C Humidity... max. 85% Programs: 10 predefined Programs in user level 1: The program definition depends on the available options included in the model. The programs can be individually changed. 10 programs in user level 2 (Program P11 to P20) Code protected. Predefinition is like P1. 2 test programs (Bowie&Dick-Test, P11, vacuum test, P12) in vacuum versions only Computer interface: - serial interface RS 485 Printer (optional)

Steam sterilizer Laboklav 55-195 Technical Datasheet 9 Laboklav 195 Overall dimension (free standing unit)(w x H x D)... Footprint (Bench top unit)(w x D).. 840 x 1215 x 700 mm 840 x 1085 mm Weight (net)...... ca. 255 kg Volume Feed water tank... Maximum Load: Sterilizer chamber: ca. 40 l - Instruments... 40 kg - Textiles... 25 kg - Liquids..... 45 Liter Total volume Total volume.... Chamber dimension ( x D)... usable Volume... Maximum allowable pressure (PS)... ca. 195 l 500 x 990 (+50-round.) mm ca. 193 l Maximum allowable temperature (TS)... 143 C Working pressure safety valve... Material number for chamber and double jacket... 1.4404 (SS 316 L) Surface roughness... 0,8 µm Pressure Device Directive 97/23/EG... Power supply: Voltage... Working power... Averaged power consumption per cycle... Protection class...... Protection level....... Water supply: Distilled or demineralised Water (acc. to annex C EN 13060:2004) Averaged feed water consumption per cycle... CE 0036, Kat. II, Module A1 3N 400V~ ( 5%), 50 Hz, 16A 6,5 kw 6,5 kwh I IP24 ca. 5,5 l Storing conditions: Temperature... 5 40 C Humidity... max. 85% Programs: 10 predefined Programs in user level 1: The program definition depends on the available options included in the model. The programs can be individually changed. 10 programs in user level 2 (Program P11 to P20) Code protected. Predefinition is like P1. 2 test programs (Bowie&Dick-Test, P11, vacuum test, P12) in vacuum versions only Computer interface: - serial interface RS 485 Printer (optional)

10 Technical Datasheet steam sterilizer Laboklav 55-195 II. Product characteristics Laboklav 55 195 Product characteristics Sterilizer chamber Lid and Locking mechanism Lid seal Temperature measurement Special features Directly steam heated by integrated seam generator, indirectly steam heated by heating jacket while preheating and drying Hinged lid with motorized locking mechanism, safety lock T-profile seal, silicon Independent temperature sensors PT100 T 0,9 = 3 s, 2-wire connection, internal resolution 0,01K, display resolution 0,1K can be calibrated Continuous monitoring of break and short cut Reference sensor for liquids Calibration certificate acc. to ISO Pressure measurement Calibration certificate acc. to ISO Feed water supply Feed water pump Feed water level regulation Over temperature protection for heaters Vacuum pump (Option) Sensor like in temperature measurement defined but with flexible connecting cable Option Electronic pressure sensor 0 to 6 bar, absolute pressure or relative pressure, programmable, resolution and display 0.1 kpa, continuous monitoring of sensor break Option Internal feed water tank with integrated degassing of feed water, automatic fill and refill, hand filling possible while lid is open 35 L/h, automatic supply from feed water tank Level sensors for low level and max level 2 independent systems: temperature control of heaters by PT 100, 2 over temperature protection switches for 220 C and 250 C, 1x with auto reset, 1x Reset by service only Water ring vacuum pump Housing from brass, compression wheel from bronze Single phase electro motor, no 3 phase system necessary! Single and fractionated prevacuum Sterile venting system Display for filter change Display for maintenance cycle Validation duct Parameter programmable (Option) Membrane filter, µ 0,2 µm, in all models Yes Automatic message generation if maintenance is needed 1 Vacuum test (PT) G1/2 1 Temperature test (TT) G1

Steam sterilizer Laboklav 55-195 Technical Datasheet 11 Microprocessor control Safety line Timer Acoustic Signal Interfaces Control of all functions, messaging by graphic display For heaters and chamber pressure Program start depending of date and time programmable Can be switched off Internal RS232 for printer External RS485 for printer, network, computer connection batch printer (Option) Fast cooling (Option) Needle printer, 50 mm writing width normal paper role Circulation system with energy recovery, energy remove by normal tap water III. Ambient conditions for Laboklav 55 195 Operation: Ambient temperature Air pressure Humidity Storing: Ambient temperature Air pressure Humidity +10 C to +40 C 700 hpa to 1060 hpa Max. 70 % rel. Hum. +1 C to +60 C 500 hpa to 1060 hpa Max 95 % rel. Hum. IV. Consumption data Laboklav 55 195 Feed water consumption per batch Cooling water consumption for condensate cooling Energy consumption per batch Heat emission into the room Power safe function Cooling water consumption for vacuum pump Cooling water for fast cooling option 0,7 to 8,5 Liter deionised water 5 to 12 Liter Normal tap water 1,8 to 7,5 kwh 0,5 to 1,9 kwh Heat recovery and degassing when cooling Ca. 2L/min when pump is running (averaged ca. 20 to 40 Liter per batch) No deionised water (feed water is running circular) The additional normal tap water depends on the load and removing temperature

12 Technical Datasheet steam sterilizer Laboklav 55-195 V. Media supply Laboklav 55 195 Electrical power supply 230 V~, single phase 16 A, 50 Hz (special option for Laboklav 55) 3N~ 400VAC, 16A, 50 Hz CEE-Standard 3x16A. each phase needs to be possible to switch off by main switch /main breaker Tap water for steam / condensate cooling and feed water cooling if fast cooling function is included Temperature Water hardness Feed water for steam generation Temperature Compressed air (Option fast cooling support) Drainage Cold tap water pressure under flow 0,5 bar Water tap and waste protecting filter / sieve need to be installed in supply pipe 20 C 0,7 bis 2,0 mmol/l Pressure under flow 0,5 bar Water tap and waste protecting filter / sieve need to be installed in supply pipe 20 C 4 to 6 bar pressure controlled, free of oil, degassed min. 20 l/min Free drainage with trap in drain pipe VI. Definition of feed water quality Laboklav 55 195 (gem. EN 285, Appendix B) Acc. to EN 285 Steam sterilizers, app. B / EN 13060 small size steam sterilizers App. C Feed water Condensate Residual dry matter 10 mg/l 1.0 mg/kg Silica oxide, SiO 2 1 mg/l 0.1 mg/kg Iron 0.2 mg/l 0.1 mg/kg Cadmium 0.005 mg/l 0.005 mg/kg Lead 0.05 mg/l 0.05 mg/kg Other heavy metals, except for iron, cadmium, lead 0.1 mg/l 0.1 mg/kg Chlorines 2 mg/l 0.1 mg/kg Phosphates 0.5 mg/l 0.1 mg/kg Conductivity (at 20 C) 15 S/cm 3 S/cm ph 5 to 7 5 to 7 Colour Colourless, clean, no deposit Colourless, clean, no deposit Hardness 0.02 mmol/l 0.02 mmol/l NOTE 1: Using water of contamination greater than specified above for steam generation, can considerably reduce the sterilizer life and void the manufacturer s warranty. NOTE 2: The condensate should be derived out of the steam collected during sterilizing cycle with the chamber empty. Tests for conformance are performed with commonly used analytic methods.

Steam sterilizer Laboklav 55-195 Technical Datasheet 13 VII. Installation dimensions 50 mm 100 mm 100 mm* t b All dimensions are minimum dimensions and should not be reduced to safe the heating power emission without problems. b T H h1 Laboklav 55 740 mm 600 mm 765 mm 1385 mm Laboklav 80 740 mm 600 mm 915 mm 1535 mm Laboklav 100 740 mm 600 mm 1065 mm 1685 mm Laboklav 135 840 mm 700 mm 965 mm 1685 mm Laboklav 160 840 mm 700 mm 1065 mm 1785 mm Laboklav 195 840 mm 700 mm 1215 mm 1935 mm * If using an external condensate tank (if no regular drainage is possible only) this dimension is additionally necessary

14 Technical Datasheet steam sterilizer Laboklav 55-195 VIII. Connections 2 1 1500..1200 h1 3 4 5 350..600 H 6 max. 300 max. 700 Connection 1 CEE power plug 3x 16A Length of power cable: 1,5 m 2 Main switch 3 Normal tape water G½ a, DN 10 mm 4 Deionised (distillate) water G½ a, DN 10 mm 5 Compressed air (option for cooling support only) G½ a, DN 10 mm Notes As alternative for Laboklav 55 a single power supply is possible 230VAC, 16A that is reducing the heating power to 3 kw! If not connected the cooling of feed water tank and spent steam condensation is not active! The temperature at steam / condensate outlet can rise up to 135 C! If not connected the auto refilling function is not working. The feed water tank needs to be filled manually! Pressure regulation and drying the compressed air needs to be installed at supply side. It is not included in the autoclave! Safety valve is not necessary because of pressure regulation and safety valve for the chamber is included in the autoclave. 6 Drainage G½ a, DN 50 mm Max. allowed temperature of drainage pipe material need to be attended! If tap water is installed, the max temperature at the drain pipe can be programmed in the control unit.

Steam sterilizer Laboklav 55-195 Technical Datasheet 15 For the connections at device side please see the following picture: connector for connector for connector for compressed air deionized water tape water (for option MS, MSL, MSV, MSLV only) Connector for drainage All connectors have G1/2 with flat seal inside. The connection should be done with temperature stable pipes (steel plated) (temperature up to 134 C), do not use PVC pipes!