Insulated Roof & Wall Panels Solutions. Product Data Sheet. X-Dek Multi-Span Insulated Roof Panel KS1000 XD Multi-Span

Similar documents
Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal SF Insulated Roof Panel KS1000 RW SF

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Topdek Single Ply Insulated Roof Deck KS1000 TD

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP

Insulated Roof & Wall Panels. Product Data Sheet. Curved Roof Insulated Panel KS1000 CR

KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW

Product Data Sheet. Product: Benchmark Wall Liner System

Insulated Roof & Wall Panels. Product Data Sheet. Sinusoidal Insulated Roof Panel KS1000 SRW

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

Core. Thickness. Biological

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

Product Data Sheet. QuadCore Karrier. Applications

QuadCore Controlled Environment Series Food Processing Datasheet

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Product Data Sheet. UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C KS1100 CS

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8

ZINC. Product Data Sheet

ACM. Product Data Sheet

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

Cleanroom Systems UltraTech

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Upstand KS1000 DLU

Firestone Polyiso Boards

Roof System KS1000 X-dek. Product Data. Application. Dimensions & Weight. Product Tolerances. Available Lengths

BENCHMARK KREATE FAÇADE & ROOF SYSTEMS

Insulated Panel Systems. 1, d0 IND E N 1350

Insulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials

Insulated Panels. CI/SfB. January CurveWall & Louvre. Architectural Wall Panel Systems. Approved to LPS 1181 Certificate No.

TR26 LPC/FM / TR27 LPC/FM

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Worldwide Competence in Plastics. Development by professionals. The long-lasting roof system

Sikatherm PIR GT. PIR Thermal Insulation Board. Product Description. Product Data

Kingspan Day-Lite Kapture Data Sheet

K5 External Wall Board

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

BAILEY. ATLANTIC. Bailey Atlantic is a high performance TPE single ply membrane. TOTAL BUILDING ENVELOPE

K5 External Wall Board

Protan Exposed Membrane Roof. Your design - Our solution

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description

Flat Roofing. Brochure

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Jabfloor 70, 100, 150, 200, 250

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

USE DUCE CYCLE ATLANTIC. High performance TPE membrane Delivering your design

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Lo-Pitch & Curved. Insulated Roof System. Product Data 257. Model Specifications 261. Fastener Selection 271. Construction Details 273

COMPOSITE PANEL ROOFLIGHTS - FAIRS

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Construction. Polymeric membrane for roof waterproofing. Product Description. Tests

Floors Walls Roofs. Jabroll. APPLICATION: Flat and Curved Roofs PRODUCTS: Vencel Resil Limited

Kingspan Insulation. Flat Roofing User Guide. Building for the Future. For more information on Kingspan Insulation visit

Technical Data Greenscreen Acoustic Barrier

Your reference for Recticel PIR insulation.

KINGSPAN THERMAROOF TR21

Boards. Products - Boards.

ROOFING SINGLE PLY MEMBRANES

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

Phenolic foam thermal insulation products for buildings and building services end use applications

FOAMULAR Commercial Roofing

Thermoplastic Single Ply & Multi-Ply Roofing Systems

URSA 20 Plus and URSA 20

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

K8 Cavity Board. Insulation CAVITY WALL INSULATION

Icopal Universal. A strong, durable roof covering. Flexible & light. Reliable. Safe to use. Sustainable. High puncture resistance

Kingspan Insulation. Flat Roofing User Guide. Building for the Future. Technical Advice

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

PROTAN EXPOSED ROOF SYSTEMS

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

Guidance document GD 20 April 2015 amended May 2017 GUIDANCE DOCUMENT ON SERVICEABILITY STATES AND DEFLECTION CRITERIA

WaterproofingSystems. Roof Waterproofing with Thermoplastic Polyolefin Membranes

YEARS SINCE Firestone UltraPly TM TPO Membranes EXPERIENCE THE ULTIMATE IN COOL ROOFING TECHNOLOGY.

Double Brick Cavity Walls

1 Firestone EPDM Roofing Systems

COMMERCIAL BUILDING APPLICATIONS

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description

Magnum Board Section Digicon Information Inc. Page 1

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS

MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING

EasylationWall. External Wall Insulation System. bringing european innovation

Miami-Dade County Certified Waterproofing System

TR27 LPC/FM. Insulation

NBS SECTION J42 - SCOPE OF WORKS

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Sandwich panel SPA Product description

Uniclass L534. CI/SfB (90.4) Sg2. TredWay. The easy-lay modular paving system

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

PermaroofUK. Frequently asked questions

INSULATED PANELS. Cold Store

Transcription:

Insulated Roof & Wall Panels Solutions X-Dek Insulated Roof Panel KS1000 XD

Dimensions, Weight & Thermal Performance X-Dek 50 X-Dek 70 Core Thickness (mm) 46 66 Overall Thickness (mm) 154 174 U-value (W/m²K) 0.33 0.25 R-Value (m² K/W) 3.03 4.00 Weight kg/m² 9-14 10-15 The U-values and R-values have been calculated using the method required by the appropriate National Building Regulations Applications KS1000 XD X-Dek panel is an insulated roof panel suitable for flat roofs on normal factory, warehouse, retail and office-type of buildings with a minimum roof pitch > 1% (to avoid ponding). Ponding is not detrimental to the performance of the membrane, but it is not recommended. It is a lightweight panel (9-15kg/m 2 ) which can span up to 6.2m (with a single span of 5.3m). This allows quick installation of up to 1000m 2 per day. 1

Finishes The panel is offered with different types of top finish as defined below. The different top (external) facings create a wide range of opportunities for application of different types of roofing waterproof membranes. The finishes are available with a singleply roofing system, mechanical mounted (screws) or chemically attached (glued). TR20 - glass fibre membrane These are panels finished on the top side with a bitumen-impregnated glass fibre layer, which is designed to be compatible with torched-on, separately-fitted bitumen systems. It therefore is suitable as a base layer, on its topside for the on-site fitting of various types of torch-on post-fit membrane. Single-Ply Membrane. This is a fully factory-finished insulated panel, equipped with a top weather surface of bonded singleply membrane. The panel is factory-finished with proprietary membranes and includes side laps for easy installation. This product does not require any further site application of weathering membrane. The factoryapplied, single-ply membrane is ready for hot air or chemical welding at side and end laps, following the installation of the panels. When the membrane end laps and side laps are site sealed, the system is then weather-proof. The external weathering membrane on this products can be made available in a number of options. However the primary, preferred options are PVC (PolyVinylChloride), TPO (Thermoplastic PolyOlefin) and TPE (ThermoPlastic Elastomers). TR20 glass fibre membrane Torch-on bitumen Insulation core Available Membranes all in 1.5mm: IKO Armourplan PVC Membrane, Mid Grey RAL 7046 IKO Armourplan PVC Membrane Light Grey RAL 7047 SIKA Trocal PVC Membrane Light Grey RAL 7047 SIKA Trocal PVC Membrane Slate Grey RAL 7016 IPS Ruberfuse TPO Membrane Light Grey RAL 7042 Skin-Plate Skin plate to be specified for single span applications where it will interface with standard panels (Note: this is not a Longspan panel). TR27 glass fibre tissue These panels are finished on the top side with a glass fibre tissue facing. This facing allows the on-site fitting of a number of non-bonded, weathering membranes. Typically these membranes can be mechanicallyfixed, loose-laid or loose-laid, ballasted, membrane systems. This glass fibre tissue membranes is not suitable for on-site membrane bonding. Roofing membrane roll Topsheet options: Sika 0.6mm steel with 0.8mm Sika membrane coating IKO 0.8mm steel with 1.2mm IKO membrane coating Standing-Seam Faux halters can be installed onto the top of the panel with the membrane laid over the top to create the illusion of a standing-seam system. Membrane Strip Membrane Flap TR27 glass fibre tissue topsheet bonded to insulation foam 2

Available Lengths Standard Lengths 1.8m 11.8m Longer Lengths (non-standard) Not available due to container restrictions Shorter Lengths (non-standard) Below 1.8m Note: surcharges apply to the cost of panels <1.8m in length. Insulation Core The core of the KS1000 X-Dek is an ECOsafe polyisocyanurate (PIR) rigid closed cell insulation core. Kingspan s Insurer Approved PIR insulated panels do not contain any Ozone Depleting Substances (ODS). Insulation cores are free from CFCs (Chlorofluorocarbons), HCFCs (Hydrochlorofluorocarbons) and HFAs (hydrofluoroalkans). This results in all Kingspan s roof and wall solutions having no global warming potential. The auto adhesive properties of the core bond the external & internal sheets together. Fire Steel inner and outer facings have a Class 1 surface spread of flame to BS476 Part 7:1987 and are class 0 as defined by building regulations. The panel surfaces are rated FAA/SAA to BS476: Part 3:1975. Environmental This ECOsafe system contributes credits to the BREEAM Pollution 4 as per the BRE Global The Green Guide to Specification, Green Guide ratings. Air Leakage An air leakage rate of < 5m³/hr/m 2 at 50Pa can be achieved. Acoustic Sound Reduction Index (SRI) Hz* 63 125 250 500 1K 2K 4K 8K SRI (db) * Frequency 14 14 19 24 27 34 34 52 The KS1000 XD insulated roof panel has a single figure weighted sound reduction Rw = 27dB. Biological Kingspan panels are normally immune to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the construction, and the panels are not considered deleterious Materials External weather sheet (single-ply membranes) 1.5mm thick high performance single ply reinforced membrane. Membrane operating temperature range is -40 to +70 C. Internal Profile Deck Sheet Substrate can be mm, mm & 1.0mm thick hot-dipped zinc coated steel to BS EN 10147: 1992. Grade Fe E220G with a Z200 zinc coating, for standard finishes. Alternative deck finishes and thicknesses are available upon request This standard liner is CLEANsafe 15: The coating has been developed for use as the internal lining of insulated panels. Standard colour is bright white with an easily cleaned surface. Panel End Cut Back Standard Cut Back Endlap Minimum Cut Back Maximum Cut Back Tolerance Cut to Length Liner Sheet Length Cover Width Thickness End Square 150mm 20mm 300mm -5mm +10mm -5mm +10mm -0mm +3mm -2mm +2mm -3mm +3mm Handing The KS1000 XD insulated roof panel can be manufactured in both left to right handed (LH) and right to left handed (RH). Seals Factory applied side & end lap weather seals. 3

Quality & Durability KS1000 XD insulated roof panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with BS EN ISO 9001 standard, ensuring long term reliability and service life. The panels are also being manufactured under Environmental Management System Certification BS EN ISO 14001. Compliant to BS OHSAS 18001 Occupational Health and Safety. Guarantee The 1.5mm and 1.2mm membranes have a 10 year minimum guarantee. For the 0.6mm to 1mm membrane please contact Kingspan Technical team. All guarantees are subject to specific terms and conditions. Packing KS1000 XD insulated roof panels are stacked weather-sheet to weather-sheet. The top, bottom, sides and ends are protected with foam and timber packing and the entire pack in wrapped in plastic. This packaging needs to be accounted for when calculating the number of panels per container. Kingspan exports its range of insulated panels and systems worldwide and the standard method of shipment is by standard shipping containers. The standard shipping container preferred by Kingspan is the closed top 12 metre units. All our shipping information and guidelines are based on this container size. For more information on packing and shipping, please speak to your local sales office. Delivery Off-loading is the responsibility of the client. Site Installation Procedure Site assembly instructions are available from Kingspan Technical Services. 4

Structural Tables Unfactured load/span table (use unfactored calculated design wind load values). KS1000 XD 70 TR20/ TR27 Single Span Condition Double Span Condition Downwards 1.68 1.15 0.80 7 - - - Suction 2.25 1.83 1.28 1.10 - - - Downwards 2.12 1.46 1.02 3 2 - - Suction 2.95 2.39 1.98 1.67 1.43 - - Downwards 2.56 1.76 1.24 0.89 0.64 - - Suction 4.57 3.48 2.65 2.04 1.60 - - Downwards 2.13 1.17 1.39 1.15 6 - - Suction 2.25 1.83 1.52 1.28 1.01 - - Downwards 2.82 2.25 1.83 1.47 1.20 9 - Suction 2.95 2.39 1.98 1.67 1.43 1.24 - Downwards 3.45 2.75 2.24 1.85 1.55 1.31 1.07 Suction 4.51 3.48 2.76 2.24 1.87 1.58 1.29 KS1000 XD 50 TR20/ TR27 Single Span Condition Double Span Condition Downwards 1.37 2 0.63 0.44 - - - Suction 2.22 1.79 1.44 1.10 - - - Downwards 1.80 1.22 0.84 9 0.42 - - Suction 2.99 2.40 1.98 1.66 1.41 - - Downwards 2.22 1.51 1.05 4 3 - - Suction 4.27 3.06 2.27 1.73 1.36 - - Downwards 1.82 1.43 1.16 5 9 - - Suction 2.22 1.79 1.48 1.24 1.06 - - Downwards 2.44 1.93 1.56 1.29 1.06 0.89 - Suction 2.99 2.40 1.98 1.66 1.41 1.22 - Downwards 3.05 2.41 1.94 1.59 1.32 1.11 - Suction 4.28 3.45 2.79 2.28 1.90 1.62 - Notes: 1. Values have been calculated using the method described in BS EN 14509: 2013, for medium and light coloured panels. 2. Deflection limit for: downward loading is L/200 and suction loading is L/150. 3. The actual wind suction load resisted by the panel is dependent on the number of fasteners used and the purlin thickness as well as the fastener material. 4. The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical Services. 5. The allowable steelwork tolerance between bearing planes of adjacent supports is +/- 5mm. 6. Load span tables for the panel specifications not shown are available from Kingspan Technical Services. 7. FM approved panels spans must be limited to a maximum of 2 metres in single/double/multi-span condition. 5

Kingspan Insulated Panels PTY Ltd Unit 1, Romead Business Park, 23 Malone Road, Maxmead, Pinetown 3610. South Africa t: +27 (0) 31 7019215 www.kingspanpanels.co.za email : info@kingspanpanels.co.za Kingspan Insulated Panels Manufacturing LLC Dubia Investments Park, Jebel Ali Dubai U.A.E, P.O. Box: 60493 t: +971 (0) 4 8854 232 www.kingspanpanels.ae email: info@kingspanpanels.ae 6