EACA-601D. Miami-Dade Qualified Combination Louver

Similar documents
EAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

EACC-601. Combination Louver/Damper Concealed Actuator. Application and Design. Standard Construction

EDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)

ESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

SED-501. Sightproof Louver Drainable Blade. Application and Design

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-130S. Thin-line Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)

Stationary Louvers. Product Type Model Description EDD-401, 601 ESD-202, 403, 435, 603, 635 EDJ-202, 401, 430, 601 EDK-402, 430, 602 ESID-430

ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM

Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER

Wall Louvers (10200)

SECTION HVAC GRAVITY VENTILATORS

Severe Duty Louvered Products. Miami-Dade County Qualified, Florida Product Approved, Wind-Driven Rain, FEMA 361 and Sand Louver

SECTION LOUVERS AND VENTS

SPECIFICATION SECTION PART 1 GENERAL

SECTION ALUMINUM WINDOWS

Louvers, Screens & Grilles /RUS BuyLine 3966

Brise Soleil Fixed Sunshades

SPECIFICATIONS: Architectural Aluminum Railings

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

SECTION EXTERIOR GRILLS AND SCREENS

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

TMS 152 / 152T / 152XT TECHNICAL MANUAL

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

TMS 114 XT TECHNICAL MANUAL

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION IMPACT RESISTANT WALL PROTECTION

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

SECTION ALUMINUM STORM WINDOWS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Architectural Coatings. to HVAC and Life Safety. A Balanced Approach

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700


Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION SECTIONAL OVERHEAD DOORS

Specifications for FL-100 Soffit Panel

SECTION METAL ROOF PANELS

Ultra Aluminum Fence, Rail & Gate Specifications

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

SECTION METAL FLOOR PLATE STAIRS

A. Access doors and frames are part of an access door and frame allowance.

SECTION DECORATIVE METAL AND GLASS RAILING

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

SECTION DECORATIVE METAL FENCES AND GATES

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

SECTION DIRECTORIES

SECTION TURBINE VENTILATORS

Sculpted 3D Minimal. Rain Screen Wall System

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Corium Brick Rainscreen System Specifications

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.

SECTION COLUMN COVERS

SECTION EXPANSION CONTROL

ALL-ALUMINUM DOOR & WINDOW FRAMING

Fire Dampers. Required information:

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

PPG Guide Specification

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

Aluminum Component Pipe Railings

SWING DOOR SPECIFICATION

CENTRIA FORMABOND II Metal Composite Wall System

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

where high efficiency is the standard

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

VITRABOND Aluminum Composite Panel Façade System Specification Template

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Built to Last a Lifetime

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

Guide Specification SDP 200

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

CORAFLON POWDER COATINGS

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

Transcription:

Miami-Dade Qualified Combination Louver Application and Design is a Florida Product Approved and Miami-Dade Qualified combination louver/damper designed to protect air intake and exhaust openings in building exterior walls that, at times, require tight air shut off. is tested in accordance with AMCA 500-L Air Performance and Water Penetration. is tested in accordance with AMCA 540 Test Method for Louvers Impacted by Wind Borne Debris (Basic Protection, Missile Level D). With the operable damper blades in the closed position is tested in accordance with AMCA 550 High Velocity Wind Driven Rain. is licensed to bear the AMCA seal allowing design professionals to select and apply with confidence. is tested and qualified per the following Florida test protocols: TAS 201 (Large Missile Impact), TAS 202 (Uniform Static Air Pressure) and TAS 203 (Cyclic Wind Loading). Per Miami-Dade, may be installed in locations where the room behind the louver is not designed to drain water into the room or the room will house non-water resistant or nonwater proof equipment components or supplies. Standard Construction Frame........... Head: heavy gauge extruded 03-T5 aluminum, in. x 0.125 in. nominal wall thickness Sill: heavy gauge extruded 005-T5 aluminum, in. x 0.125 in. nominal wall thickness Jambs: heavy gauge extruded 005-T5 aluminum, in. x 0.188 in. nominal wall thickness Blades........... Stationary blade: drainable design, heavy gauge extruded 03-T5 aluminum, 0.081 in. nominal wall thickness, positioned at 45º angles on approximately 5 in. centers Operable blade: airfoil design, heavy gauge extruded 005-T5 aluminum, 0.081 nominal wall thickness Seals............ TPE blade seals Compressible stainless steel jamb seals Temperature Restrictions....... (-20º F) - (+180ºF) Linkage.......... Side linkage, out of airstream (concealed in frame) Bearings......... Synthetic sleeve type Axles............ ½ in. dia. zinc plated steel Construction...... Mechanically fastened Birdscreen........ 3/4 in. x 0.051 in. flattened expanded aluminum in removable frame, inside mount (rear) Finish............ Mill Minimum Size..... 12 in. W x 1 in. H Maximum Single Section Size.......0 in. W x 120 in. H Options (at additional cost) A variety of bird and insect screens A variety of electric, pneumatic or manual actuators Extended sill Filter rack Flanged frame Security bars A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paint *Width and height dimensions furnished approximately ¼ inch under size. 1Operable damper blades in the closed position

PERFORMANCE DATA Free Area Chart (Sq. ft.) Louver Height Inches Louver Width in Inches 12 18 24 30 3 42 48 54 0 1 0.1 0.28 0.40 0.52 0.4 0.75 0.87 0.99 1.11 18 0.29 0.51 0.73 0.95 1.17 1.39 1.1 1.83 2.05 24 0.49 0.8 1.23 1.0 1.9 2.33 2.70 3.07 3.44 30 0. 1.15 1.4 2.14 2.3 3.12 3.2 4.11 4.0 Greenheck Fan Corporation certifies that the louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. 3 0.82 1.44 2.0 2.8 3.29 3.91 4.53 5.15 5.7 42 1.12 1.97 2.81 3.5 4.49 5.34.18 7.02 7.87 48 1.32 2.31 3.31 4.30 5.29.28 7.27 8.2 9.25 54 1.49 2.0 3.72 4.84 5.95 7.07 8.19 9.30 10.42 0 1.5 2.90 4.14 5.38.2 7.8 9.10 10.34 11.58 1.95 3.42 4.89.35 7.82 9.28 10.75 12.22 13.8 72 2.15 3.77 5.38 7.00 8.1 10.23 11.84 13.4 15.07 78 2.32 4.0 5.80 7.54 9.28 11.02 12.75 14.49 1.23 84 2.49 4.35.21 8.08 9.94 11.80 13.7 15.53 17.40 90 2.79 4.87.9 9.05 11.14 13.23 15.32 17.41 19.50 9 2.98 5.22 7.4 9.70 11.94 14.17 1.41 18.5 20.89 Greenheck Fan Corporation certifies that the louvers shown herein are approved to bear the AMCA Listing Label. The Ratings shown are based on tests and procedures performaned in accordance with AMCA Publications and comply with the requirements of the AMCA Listing Label Program. The AMCA Listing Label applies to Wind Borne Debris Impact Resistant Louvers and High Velocity Wind Driven Rain Resistant Louvers. 102 3.15 5.51 7.87 10.24 12.0 14.9 17.32 19.9 22.05 108 3.32 5.80 8.29 10.78 13.2 15.75 18.24 20.73 23.21 114 3.2.33 9.04 11.75 14.4 17.18 19.89 22.0 25.31 120 3.81.8 9.54 12.40 15.2 18.12 20.98 23.84 2.70 Airflow Resistance (Standard Air -.075 lb/ft 3 ) Water Penetration (Standard Air -.075 lb/ft 3 ) Test size 48 in. x 48 in. Test duration of 15 min. Model resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information. (Test Figure 5.5) The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through.01 oz. of water (penetration) per sq. ft. of louver free area. * The beginning point of water penetration for Model is 1233 fpm free area velocity. These perfor mance ratings do not guarantee a louver to be weather proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.

INSTALLATION DETAILS Maximum Size and Installation Information Model is a Miami-Dade Qualified and Florida Product Approved louver and must be installed in accordance with the installation instructions shown herein. Model is qualified for installation within concrete, CMU, wood, aluminum, structural steel or steel stud framed building conditions. Model is structurally calculated to withstand positive and negative wind-loads up to 110 PSF. The maximum single section width is 0 inches. The maximum single section height is 120 inches. While the maximum opening height is limited to 120 inches, the opening width may be unlimited as multiple sections may be installed side by side in accordance with installation instructions. Minimum Single Section Size 12 in. W x 1 in. H Maximum Single Section Size 0 in. W x 120 in. H

INSTALLATION DETAILS CONCRETE OR CMU ANCHORING 1/4" TAPCON SCREW FASTENER TABLE DESCRIPTION SUBSTRATE 1/4" TAPCON W/ ADVANCED THREADFORM CONCRETE OR CONCRETE MASONRY (CMU) CONCRETE: 3 KSI ACI 301 CONCRETE CMU: ASTM C90, 3 KSI MINIMUM GROUT FILLED, LIGHT WEIGHT 95 PCF, MEDIUM WEIGHT 117 PCF EDGE DISTANCE <MIN> 1 IN 1 1/2 IN 2 1/2 IN SLAB/BLOCK CORNER DISTANCE <MIN> 1 IN 1 1/2 IN 2 1/2 IN PENETRATION <MIN> LOUVER HEIGHT <IN> 1 3/4 IN 120 4 4 84 72 CONCRETE OR CMU ANCHORING 3/8" POWERS WEDGE BOLT FASTENER TABLE DESCRIPTION 3/8" POWERS WEDGE BOLT SUBSTRATE NORMAL WEIGHT CONCRETE CONCRETE MASONRY (CMU) " WIDE, GRADE N, TYPE II, MINIMUM 2.5 KSI LIGHT/MEDIUM/NORMAL WEIGHT CMU CONFORMING TO ASTM C90, 1.5 KSI GROUT FILLED EDGE DISTANCE <MIN> 2 IN 3 IN 1 1/2 IN 2 IN SLAB/BLOCK CORNER DISTANCE <MIN> 2 IN 3 IN 1 1/2 IN 2 IN PENETRATION <MIN> 2 1/8 IN 2 1/2 IN ANCHOR ANGLE END DISTANCE <MIN> <= <ANCHOR SPACING>/2+3 <= <ANCHOR SPACING>/2+3 LOUVER HEIGHT <IN> 120 NOT ALLOWED NOT ALLOWED 9 8 72 8 8 48 8 WOOD, STEEL OR ALUMINUM ANCHORING LAG SCREW, SCREW, & BOLT W/NUT FASTENER TABLE DESCRIPTION 1/4" LAG SCREW 3/8" LAG SCREW 1/4" 20 SCREW OR BOLT W/NUT SUBSTRATE WOOD STEEL ALUMINUM MINIMUM G 0.42 A3 STEEL OR Fy 3 KSI STRESSES 03 T5 EDGE DISTANCE <MIN> 1 IN 1 1/2 IN 1/2 IN 1/2 IN CORNER DISTANCE <MIN> 1 IN 1 1/2 IN 1/2 IN 1/2 IN PENETRATION* <MIN> 2 3/4 IN 1 GA <0.0 IN> 3/1 IN 1 GA <0.0 IN> LOUVER HEIGHT <IN> 120 4 4 9 4 84 8 72 * PENETRATION IS EQUAL TO OVERALL FASTENER LENGTH FOR CONCRETE/CMU FASTENERS IF SHIMS ARE USED, FASTENER LENGTH MUST BE INCREASED BY THICKNESS OF SHIMS

PRODUCT DETAILS

OPTION DRAWINGS FINISHES Finish Type Description/Application Color Selection Standard Warranty (Aluminum) 2-coat 70% KYNAR 500 /HYLAR 5000 AAMA 205 Dry film thickness 1.2 mil. (AKA: Duranar, Fluoropon, Trinar, Flouropolymer, Polyvinylidene Fluoride, PVDF2) Best. The premier finish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% KYNAR 500 /HYLAR 5000 or Baked Enamel. 10 Years (Consult Greenheck for availability of extended warranty) 2-coat 50% KYNAR 500 /HYLAR 5000 AAMA 204 Dry film thickness 1.2 mil. (AKA: Acroflur, Acrynar ) Baked Enamel AAMA 203 Dry film thickness 0.8 mil. (AKA: Acrabond Plus, Duracron ) Better. Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Good. Provides good adhesion and resistance to weathering, corrosion and chemical stain. 2-Coat Mica: Greenheck offers 9 standard 2- coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special finishes. 5 Years 1 Year Integral Color Anodize AA-M10C22A42 (>0.7 mil) Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Clear Anodize 204 R-1 AA-M10C22A31 (0.4-0.7 mil) Industrial coatings Mill Two-step anodizing is produced by following the normal anodizing step with a second, colorfast process. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Light, Medium or Dark Bronze; Champagne; Black Clear Clear Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector. Consult a Greenheck Product Specialist for complete color and application information. Materials may be supplied in natural aluminum or galvanized steel finish when normal weathering is acceptable and there is no concern for color or color change. 5 years 5 years 1 Year Consult Greenheck Finishes meet or exceed AAMA 205, AAMA 204, and AAMA 203 requirements. Please consult www.greenheck.com for complete information on standard and extended paint warranties. Paint finish warranties are not applicable to steel products. n/a November 2017 Copyright 2017 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.