Experimental testing of post-tensioned concrete industrial floor model subsidence analysis

Similar documents
Jurnal Teknologi EXPERIMENTAL AND NUMERICAL ANALYSIS OF INTERACTION BETWEEN SUBSOIL AND POST- ENSIONED SLAB-ON-GROUND. Full Paper

Jurnal Teknologi EXPERIMENTAL LOAD TESTS OF REINFORCED CONCRETE SLAB. Full Paper. Vojtech Buchta *, Roman Fojtik, Jan Hurta

Comparison of geotechnic softwares - Geo FEM, Plaxis, Z-Soil

World Academy of Science, Engineering and Technology International Journal of Civil and Environmental Engineering Vol:8, No:7, 2014

Comparative Study on Post - Tensioned and Reinforced Concrete flat Slab Systems for a Multistory Building

Non Linear Analysis of Composite Beam Slab Junction with Shear Connectors using Ansys.16

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

Sabah Shawkat Cabinet of Structural Engineering 2017

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

In-plane testing of precast concrete wall panels with grouted sleeve

EXPERIMENTAL AND NUMERICAL SIMULATIONS OF COLLAPSE OF MASONRY ARCHES

Modelling of RC moment resisting frames with precast-prestressed flooring system

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

UHPC Connection of Precast Bridge Deck

ST7008 PRESTRESSED CONCRETE

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

SOIL PRESSURE IN EMBANKMENT STABILIZATIONS

Nonlinear Analysis of Shear Dominant Prestressed Concrete Beams using ANSYS

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

Nonlinear Finite Element Modeling & Simulation

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

PILE RAFT FOUNDATION BEHAVIOR WITH DIFFERENT PILE DIAMETERS

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

EXPERIMENTAL STUDY OF THE DEFORMATION CAPACITY OF STRUCTURAL MASONRY

ABSTRACT. KEY WORDS: Tubular piles; composite behavior; offshore structures; push-out strength; bond strength; slip.

THE PERFORMANCE OF CONCRETE GROUND FLOOR SLAB REINFORCEMENT TO CONTROL SHRINKAGE CRACKING. D H Chisholm 1

DESIGN FOR PROGRESSIVE COLLAPSE 1

POST TENSIONED SLABS. Imagineering the possibilities

An example of finite element modelling of progressive collapse

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

3D analysis of solid reinforced concrete beams subjected to combined load of bending, torsion and shear

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

THE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS

Applications of sustainable post-tensioned concrete slabs

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

Shaking Table Test of Controlled Rocking Reinforced Concrete Frames

Two-dimensional finite element analysis of influence of plasticity on the seismic soil micropiles structure interaction

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Modelling of a pile row in a 2D plane strain FE-analysis

Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure

ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT

Post-tensioned prestressed concrete bridge - assignment

STRUCTURAL CALCULATIONS

DESIGN GUIDELINES FOR BRIDGE DECK SLABS REINFORCED by CFRP and GFRP

PRESTRESSED CONCRETE DESIGN

The Influence of the Seismic Action on the RC Infilled Frames

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

Transactions, SMiRT-22 San Francisco, California, USA - August 18-23, 2013 Division V

Numerical study of shear wall behavior coupled with HPFRCC beam and diagonal reinforcements

Chapter. Masonry Design

3.5 Tier 1 Analysis Overview Seismic Shear Forces

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Experimental Research of Bridges with Encased Beams

APPROXIMATE ANALYSIS OF PILED RAFT. Rameez Gahlot1, Roshni J John2

Finite Element Modelling of Unreinforced Masonry (URM) Wall with Openings: Studies in Australia

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Steel fibres Structural applications

Research Project. concrete footings taking into account the soil structure interaction

VOL. 11, NO. 16, AUGUST 2016 ISSN ARPN Journal of Engineering and Applied Sciences

Hybrid Reinforced Concrete Frame Building with Pumice Brick Masonry Infill under Static Lateral Loading

Effect of beam dimensions on structural performance of wide beam-column joints

SAFE 2016 (v16.0.0) Release Notes

NEW ZEALAND S FIRST POST-TENSIONED CONCRETE MASONRY HOUSE. Gavin Wight 1 Jason Ingham 2 Andrew Wilton 3

Two-way slabs. Flat plate with or without drop panels / capitals

The cracking behaviour of reinforced concrete beams under static and dynamic loading

Influence of Orientation of Piles on Seismic Response of Pile Groups

ZANCO Journal of Pure and Applied Sciences

THE BEHAVIOR OF TWO MASONRY INFILLED FRAMES: A NUMERICAL STUDY

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Extreme Loading for Structures Version 3.1

Finite Element Modeling of New Composite Floors Having Cold-Formed Steel and Concrete Slab

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

A Research on Comparison of R.C.C and Post Tensioned Flat Slab with or Without Drop Using Software

INFLUENCE OF BNWF SOIL MODELLING ON DYNAMIC BEHAVIOUR OF PILE FOUNDATION FOR RC FRAME WITH STRUCTURAL WALL

HILLCREST MANOR Palo Verde, California

Modelling shearing characteristics of reinforced concrete

Behaviour of Concrete Filled Rectangular Steel Tube Column

On Finite Element Analysis of Steel and RC Beams : Performance of Different Elements

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Analysis of Shear Wall Transfer Beam Structure LEI KA HOU

Title: Large Deflections

EVALUATION OF LAMINATED HOLLOW CIRCULAR ELASTOMERIC RUBBER BEARING

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

LATERAL CAPACITY OF SKIRT FOUNDATION ON LOOSE SUBMERGED SAND

SEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE

Simplified Finite Element Modelling of Multi-storey Buildings: The Use of Equivalent Cubes

Soil-foundation-superstructure interaction: effects on the soil

ctbuh.org/papers A Study of Flat Plate Slab Column Connections with Shear Plate in Tall Concrete Building using Experimental and Numerical Analysis

Parametric Study of Continuous Concrete Beam Prestressed with External Tendon

Numerical Analysis of the Influence of Geometry of Ceramic Units (Blocks) on Structural Walls

Optimization Design of Cold Roll-beating Experiment Device Based on ANSYS Workbench

Transcription:

Experimental testing of post-tensioned concrete industrial floor model subsidence analysis Petr Mynarcik, Radim Cajka Abstract The behavior of slab-on-ground constructions - subsidence of constructions and interaction between concrete structure and subsoil is one of the main research directions at the Faculty of Civil Engineering, VSB Technical university of Ostrava Actually, scope of research is focused on concrete post-tensioned slab-on-ground. The article presents the process of a static load test on a post-tensioned concrete industrial floor model. The experimental model was designed as a cutout of a post-tensioned concrete industrial floor, and the static load test was conceived as a simulation of loading by base plate of a heavy rack. During the static load test, measurements focused on observation of subsidence and results of subscribed experiment were used for comparison with basic FEM model. Keywords Post-tensioned concrete, Industrial concrete floors, Interaction between post-tensioned slab and subsoil, Sliding joint, Slab-on-ground, Prestressing bar concreted. The experimental model was designed as a cutout of A post-tensioned concrete industrial floor and the static load test was a loading simulation of base plate of a heavy rack. The experiment served to give a better understanding and possible improvement of these technologies from the perspective of interaction with the subsoil III. DESCRIPTION OF THE POST-TENSIONED CONCRETE FLOOR MODEL The basic dimensions of experimental model were 2000 x 2000 x 150 mm. The concrete type C35/45 XF1 was used for concreting. C I. INTRODUCTION ONCRETE industrial floors must fulfill a number of very specific requirements - adequate flatness, limited cracking and especially sufficient load capacity. This paper focuses on the subsidence issue of post-tensioned concrete industrial floors and describes the process of experimental static load test on a large-dimension posttensioned concrete industrial floor model. II. SUBSIDENCE OBSERVATION OF CONCRETE INDUSTRIAL FLOORS AND SLAB-ON-GROUND CONSTRUCTIONS The behavior of slab-on-ground constructions - subsidence of constructions and interaction between concrete structure and subsoil is one of the main research directions at the Faculty of Civil Engineering, VŠB Technical university of Ostrava [1], [3]. Currently research focuses on post-tensioned concrete slabs-on-ground and industrial floors. For the experimental static load test a model of a post-tensioned industrial floor was This paper has been written with the financial support of the Ministry of Education, specifically by the Student Research Grant Competition of the Technical University of Ostrava under identification number SP2015/52. Petr Mynarcik is with Faculty of Civil Engineering Department of Structures, VSB - Technical University of Ostrava, Ludvika Podeste 1875/17, 708 33, Ostrava Poruba, Czech Republic, (phone:+420 597 321 925, e-mail: petr.mynarcik@vsb.cz) Radim Cajka is with Faculty of Civil Engineering Department of Structures, VSB - Technical University of Ostrava, Ludvika Podeste 1875/17, 708 33, Ostrava Poruba, Czech Republic, (e-mail: radim.cajka@vsb.cz) Fig. 1 The steel formwork with ducts for prestressing bars The experimental model was post tensioned by six fully threaded prestressing threadbars. The materials of the threadbars were made of low relaxation steel with designation Y 1050, and the diameters of these threadbars were 18 mm. The prestress force for each threadbar was 100kN. Threadbars were anchored by domed nuts and recessed anchor plates. The model was laid on homogenous subsoil. A sliding joint was placed between the contact surface of the concrete floor model and the subsoil [4]-[5]. This sliding joint was made of a combination of PVC foil and geotextile [6]-[7]. The experimental model was situated in an outdoor testing device STAND [8]. ISSN: 1998-4448 33

Fig. 2 Post - tension process with use of hollow hydraulic cylinder IV. DESCRIPTION OF TESTING DEVICES AND MEASUREMENTS The outdoor testing device STAND consists of two frames. Crossbeams enable variability of the press machine location. The frames are anchored with screws into a steel grate based in the reinforced concrete strip foundations. The construction is anchored with 4 m long micro piles. The greatest possible vertical load is 1 MN [8]. The experimental static loading test consisted of the assembly of a set of measurements. Fig. 4 Strain gauges for tension measurement inside the slab Experimental measurement line: Vertical deformation measurement (potentiometric position sensors); measurement of the vertical load (Built-in pressure sensors); strain measurement on the surface of the slab (Strain gauges); o strain measurement inside the slab (Strain gauges); measuring the stress on the interface of the slab and soil (Geotechnical pressure cells); Temperature inside and on the surface (temperature sensors). Fig. 5 Installation of geotechnical pressure cells V. DESCRIPTION OF THE SUBSOIL ATTRIBUTES The experimental model was implemented on a compacted gravel bed. Gravel bed layer thickness was 300 mm and was compacted on prime clay subsoil without greensward [9], [10]. The subsoil characteristics were determined by standard geotechnical measurements. Subsoil attributes: Subsoil consists of loess loam with F4 consistency; thickness of subsoil layer is about 5 meters; volumetric weight of soil γ = 18.5 kn.m-3; poisson coefficient ν = 0.35; static Young s modulus EDEF = 33.86 MPa; oedometric modulus of elasticity EOED= 4.27 MPa. Fig. 3 The complete assembly for static load test VI. PROCESS OF STATIC LOAD TEST The vertical load was generated by a high tonnage hydraulic cylinder ENERPAC CLRG. The loaded equipment was placed between the experimental model and the steel extension fixed on STAND. The hydraulic system was equipped with a pressure sensor. Potentiometric position sensors were installed on the surface of the concrete floor model. These ISSN: 1998-4448 34

gauges were connected to the same sensor station with automatic scanning and recording. The shape and size of the load area simulated the base plate of a heavy loaded rack. The dimensions of the load area were 200 x 200 mm. A fixed interval of loading - 75kN / 30 min was chosen for this experimental testing. Fig. 7 Deployment plan of potentiometric sensors Fig. 6 The loading diagram of post-tensioned concrete industrial floor model VII. RESULTS OF STATIC LOAD TEST AND SUBSIDENCE MEASUREMENTS Potentiometric sensors situated on the non-contact surface recorded vertical deformations in particular positions. The deployment plan of potentiometric sensors is displayed in Fig.7. The measured data was processed into graphs of vertical deformation development - subsidence. The development of subsidence in the edge area of experimental model is represented by lines A-A and C-C (Fig. 8 and Fig. 10). From the graphs of edge area the lifting in corners of the experimental model is noticeable. The development of subsidence in the central area of experimental model is represented by lines B-B and D-D (Fig. 9 and Fig. 11). These graphs showed centralized subsidence in the central part of experimental model. The creation and progression of punching shear is also noticeable from graphs of lines B-B and D-D. Fig. 8 Subsidence in the edge area of experimental slab model line A-A (Potentiometric sensor - m14, m9, m8, m1) Fig. 9 Subsidence in the central area of experimental slab model line B-B (Potentiometric - sensor m15, m13, m4, m3) ISSN: 1998-4448 35

Fig. 10 Subsidence in the edge area of experimental slab model line C-C (Potentiometric sensor - m16, m13, m4, m3) Fig. 12 Cracks near anchor of middle prestressing threadbar Fig. 13 Punching shear damage under loading area of hydraulic press Fig. 11 Subsidence in the central area of experimental slab model line D-D (Potentiometric sensor - m13, m12, m11, m10, m9) VIII. EVALUATION OF EXPERIMENTAL MEASUREMENTS The experimental post-tensioned concrete industrial floor model resists the loads exerted after seven load cycles and induced maximal load level 525 kn. Loading process of experimental model was continuous testing. Subsidence of concrete slab was equally over the entire surface after three loading cycle. After third steps, central part of experimental model started outstrips edge parts. Concurrently at the same time, edge parts started lifting. The first significant cracks were detected after the fourth cycle. These cracks were located near anchors of middle threadbars. After the sixth cycle the first signs of punching shear were detected. The experiment was terminated at the moment when the model was severely damaged by punching shear. Maximal vertical deformation measured on the experimental post-tensioned floor model: Edge area: 10,12 mm (line A-A ) Central area: 16,50 mm (line B-B ) Fig. 14 Detail - punching shear damage Subsidence at the central part (lines B-B and D-D ) was balanced in both directions. The location of the test pattern inside the test experimental STAND and the use of available handling techniques enabled to lift the test slab. Threadbars were used for anchorage for stretching hanging straps. A pair of chain hoists was hung on the STAND beams. The experimental model was lifted and allowed the course of cracks evaluation right on post-tensioned slab surface that was in contact with the subsoil. The crack cross is highlighted with red colour on Fig.15. ISSN: 1998-4448 36

There are too many unknowns and variables quantities, because this problematic is combination of two different exercises with different ways of solution concrete slab and subsoil Actually, harmonization of ANSYS model is in progress. Second direction of solve the interaction task is create the model in different FEM software and compare results. And finally, third direction of solving this task is creation of specialized FEM software for this specific modelling of interaction between concrete structure and subsoil. The results of experiment and results of FEM analysis in universal software are very important for this next step in research. Fig. 15 Course of cracks on the contact surface of post-tensioned concrete industrial floor model Main cracks on contact surface of post-tensioned model were situated in directions of middle ducts for prestressing threatbars. These cracks draw full cross to the boundaries of concrete slab. Signs of these cracks were observed near threadbar anchors after fourth loading cycle. Central crack meshes was signal of punching shear damage. Experimental model was sectioned to 8 sub sections after end of experimental measurement. Course of cracks along the height of slab were studied on this sub - sections. These minority measurements serve to specifications of basic control perimeter for calculation punching shear capacity. Fig. 17 FEM interaction model of post-tensioned concrete industrial floor model Fig. 16 Experimental model sectioned into 8 sub-sections IX. FEM ANALYSIS Results of subscribed experiment are used for comparison with FEM model. Problematic of interaction between subsoil and post-tensioned industrial floors or foundation structures is active research scope around the world [17]-[19]. Numerical model of experimental model was created with ANSYS finite element method software. Concrete post-tensioned model was created as a shell element with linear isotropic material properties. Subsoil was created as a solid element with isotropic elasto-plastic model aka "Drucker - Prager Model". Results of comparison between FEM model and real experiment results are divergent. Reason for divergence is difficult modelling of contact between concrete and subsoil. Fig. 18 Boundary conditions of FEM interaction model ISSN: 1998-4448 37

Fig. 19 Total vertical displacement of FEM interaction model X. CONCLUSION This experiment offers much information about the influence of post-tensioning on punching shear resistance [11]- [13]. The measured data will serve for the creation of a numerical model by the FEM (finite element method) [14]. Post-tensioning influences both the behaviour (crack opening, rotations) and strength of slabs subjected to concentrated loads. Post-tensioned members have stiffer responses (associated with lower extents and openings of the flexural cracks) and higher punching resistances for the same amount of non-post-tensioned flexural reinforcement [14]-[16]. REFERENCES [1] P. Mynarcik, Measurement processes and destructive testing of fibre concrete foundation slab pattern, Advanced Material Research, Vol. 1020, pp. 221-226 (6 p), Trans Tech Publications, Switzerland, ISSN (Online) 1662-8985, ISSN (Print) 1022-6680, DOI: 10.4028/www.scientific.net/AMR.1020.221, 2014. [2] R. Cajka, R. Fojtik, Development of Temperature and Stress during Foundation Slab Concreting of National Supercomputer Centre IT4, Procedia Engineering, Vol. 65, 2013, pp. 230-235 (6 p), ISSN 1877-7058, doi: 10.1016/j.proeng.2013.09.035.,2013 [3] R. Cajka, K. Burkovic, V. Buchta, Foundation Slab in Interaction with Subsoil, Advanced Materials Research, Vol. 838-841, pp. 375-380 (6 p), Trans Tech Publications, Switzerland, doi:10.4028/www.scientific.net/amr.838-841.375, 2014. [4] M. Janulikova, R. Cajka, P. Mateckova, V. Buchta, Laboratory Testing of Asphalt Belts Rheological Properties Exposed to Shear Loads, Transactions of the VSB - Technical University of Ostrava, Civil Engineering Series, Vol. XII, Iss. 2, pp. 59 66 (8 p), ISSN (Online) 1804-4824, ISSN (Print) 1213-1962, doi: 10.2478/v10160-012-0018-2, 2013. [5] M. Janulikova, M. Stara, Multi-layer Rheological Sliding Joint in the Foundation Structures, Transactions of the VSB Technical University of Ostrava, Civil Engineering Series, Vol. XIII, iss. 2, pp. 41 46 (6 p), ISSN (Online) 1804-4824, ISSN (Print) 1213-1962, doi: 10.2478/tvsb- 2013-0008, 2013. [6] M. Janulikova, P. Mynarcik, Modern Sliding Joints in Foundations of Concrete and Masonry Structures, International Journal of Mechanics, Vol.8, iss.1, United States: North Atlantic University Union, pp. 184-189 (6 p), ISSN 1998-4448, 2014. [7] M. Janulikova, M. Stara, P. Mynarcik, Sliding Joint from Traditional Asphalt Belts, Advanced Material Research, Vol. 1020, pp. 335-340 (6 p), Trans Tech Publications, Switzerland, ISSN (Online) 1662-8985, ISSN (Print) 1022-6680, doi: 10.4028/www.scientific.net/AMR.1020.335, 2014. [8] R. Cajka, V. Krivy, D. Sekanina, Design and Development of a Testing Device for Experimental Measurements of Foundation Slabs on the Subsoil, Transactions of the VSB Technical University of Ostrava, Civil Engineering Series, Vol. XI, Iss. 1, pp. 1-6 (6 p), ISSN (Online)1804-4824, ISBN 978-80-248-2332-4, doi: 10.2478/v10160-011-0002-2, 2011. [9] K. Burkovic, R. Fojtik, J. Labudkova, V. Buchta, Verification of the feasibility and load carrying capacity of models of bored concrete piles, Advanced Materials Research, Vol. 1082, pp 230-235, Trans Tech Publications, Switzerland, doi: 10.4028/www.scientific.net/AMR.1082.230 [10] Cajka, R., Burkovic, K., Mateckova, P., Sekanina, D., Stara, M., Jurcikova, A., Reinforced Concrete Structure of the Puppet Theatre in Ostrava, Applied Mechanics and Materials, Vol. 744-746 (2015), pp. 217-221,Trans Tech Publications, Switzerland, ISSN: 1660-9336, ISBN: 978-3-03835-420-8, doi:10.4028/www.scientific.net/amm.744-746.217, 2015. [11] R. Cajka, Analytical derivation of friction parameters for FEM calculation of the state of stress in foundation structures on undermined territories, Acta Montanistica Slovaca, Vol. 18, iss. 4, pp. 254-261 (8 p), ISSN: 13351788, 2013. [12] J. Labudkova, R. Cajka, Comparsion of Measured Displacement of the Plate in Interaction with the Subsoil and the Results of 3D Numerical Model, Advanced Material Research, Vol. 1020, pp. 204-209 (6 p), Trans Tech Publications, Switzerland, ISSN (Online) 1662-8985, ISSN (Print) 1022-6680, doi: 10.4028/www.scientific.net/AMR.1020.204, 2014. [13] R. Cajka, K. Burkovic, V. Buchta, R. Fojtik, Experimental soil - Concrete plate interaction test and numerical models, Key Engineering Materials, Vol. 577-578, pp. 33-36 (4 p), Trans Tech Publications, Switzerland, doi:10.4028/www.scientific.net/kem.577-578.33, 2014. [14] R. Cajka, J. Labudkova, Dependence of deformation of a plate on the subsoil in relation to the parameters of the 3D model, International Journal of Mechanics, Vol. 8, pp 208-215, ISSN: 1998-4448, 2014. [15] R. Cajka, J. Labudkova, Fibre Concrete Foundation Slab Experiment and FEM Analysis, Key Engineering Materials, Vols. 627, (2015), pp 441-444, Trans Tech Publications, Switzerland, doi:10.4028/www.scientific.net/kem.627.441, 2015. [16] R. Cajka, J. Labudkova, Comparison of results of analyses the foundation slab calculated by two FEM programs, Applied Mechanics and Materials, Vol. 1065 1069, pp 1052-1056, Trans Tech Publications, Switzerland, doi: 10.4028/www.scientific.net/AMR.1065-1069.1052, 2014. [17] L. Gödde, P. Mark, Numerical simulation of the structural behaviour of SFRC slabs with or without rebar and prestressing, Materials and Structures/Materiaux et Constructions, Vol. 48 (6), pp. 1689-1701, ISSN: 1359-5997 (Print) 1871-6873 (Online), doi: 10.1617/s11527-014-0265-z, 2015. [18] A. Ionescu, F.E.M. and experimental studies concerning new devices for seismic damping of buildings subjected to earthquakes, International Journal of Mechanics, Vol. 9, pp 112-119, ISSN: 1998-4448, 2015. [19] K. Kazakov, Formulation of elastodynamic infinite elements for dynamic Soil-Structure interaction, WSEAS Transactions on Applied and Theoretical Mechanics, Vol. 6 (3), pp 91-96, ISSN: 1991-874, 2011. ISSN: 1998-4448 38