BEFORE ALL HAIL BREAKS LOOSE!

Similar documents
OREGON ROOF CONSULTING - ROOF INSPECTION FORM

Roof Inspection Report

ROOF SUBSTRATE PREP MANUAL

SINGLE PLY MEMBRANE ROOF SYSTEM

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

Specification Test Standard for Impact Resistance Testing of Rigid Roofing Materials by Impacting with Freezer Ice Balls

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION

INSTALLING A NEW ROOF? Materials, Tips and Considerations

Prepared By. Accent Building Sciences Inc. For

SECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

SECTION TEMPORARY ROOFING MEMBRANE INSTALLATION. A. Areas of the roof deck for asbestos abatement.

DURO-SHIELD ROOF COATING CARE GUIDE TABLE OF CONTENTS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

C. Jointing of Exterior Vertical Surfaces. Section D. The Secretary of the US Department of the Interior s Standards for Rehabilitation.

Design and Construction Standards SECTION MODIFIED BITUMEN ROOFING SYSTEM

SPECIFICATION GUIDELINE

FM APPROVALS Boston Providence Turnpike, Norwood, MA Phone: (781) Fax: (781) E mail:

ALBERTA ROOFING CONTRACTORS ASSOCIATION. This old roof ain t what she used to be

ADDENDA #3- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

The Alabama Building Commission has adopted the 2006 International Energy Conservation Code as the State Energy Conservation Code

Pol-E-Base Modified Bitumen Roof System

SMOOTH SURFACED BUILT-UP ROOFS WITH ARC SEBS REFLECTIVE ROOF COATINGS

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

REI ENGINEERS S. TAMIAMI TRAIL, SUITE , BONITA SPRINGS, FL PHONE FAX

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

Summary of Existing Conditions: Point Pleasant Borough High School

Update In Progress. Division 7 Thermal and Moisture Protection Page Section ROOFING AND WATERPROOFING

DIVISION 07 - THERMAL & MOISTURE PROTECTION

MAINTENANCE INSPECTION GUIDE

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.

J&L Building Materials, Inc. Commercial Roofing

A PROGRAM OF IBHS COMMERCIAL

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

Duro-Last Roofing System. Protecting Your Investment

ZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -# Sunrise, Florida Phone

UNIVERSITY OF MISSOURI Division 07 Thermal and Moisture Protection Roofing:

Impact Resistance What the Hail Is Happening?

TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

SPECIFICATION GUIDELINE

Henry #1 CHOICE OF PROFESSIONALS

A. Meet at Project site <insert number> days before starting installation.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Shingle specifications should be similar to TAMKO Heritage.

SECTION ALPHAGUARD RESTORATION 20 YEAR WARRANTY SYSTEM. f. Conditions and Division 01 Specification Sections, apply to this Section.

ACRYLIC Elastek #127 Solar One Plus

Copolymer BEFORE. Copolymer DURING. Copolymer AFTER. (800) TRI-CHEM 3

SECTION CONCRETE TILE ROOFING. A. American Society for Testing and Materials (ASTM):

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

THERMOTEK ACRYLIC ELASTOMERIC SYSTEM OVER MODIFIED BITUMEN AND/OR BUR MEMBRANE

GAF Scheduled Maintenance Checklist

OREGON CONVENTION CENTER CHILLER PLANT RE-DESIGN CD SET

An industry workhorse

Field Planning and Data Collection Practices for Conducting Detailed Natural Hazard Vulnerability Assessments of Campus Structures

SECTION 07530CP EPDM MEMBRANE ROOFING

Bituminous Sheet Flat Roofs: Their repair and maintenance

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

REPORT OF ROOF CONDITION STUDY. YOUR FACILITY Your Facilities Location. Date YOUR FACILITY S IDENTIFICATION. Prepared for Your Company

UC Denver Guidelines and Design Standards Rev 2/2009 SECTION GENERAL INFORMATION

PRODUCT GUIDE SPECIFICATION

Inspection Report. Riverpark Place Condominium Complex S. Riverside Dr. Tulsa, Oklahoma. For

SECTION BUILT-UP BITUMINOUS WATERPROOFING

URETHANE. Asphalt Restoration Aged BUR and Modified Bitumen Sample Design Guideline

MOISTURE MANAGEMENT. Providing roofing and waterproofing solutions. Zionsville High School Roof Asset Management Plan

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Henry #1 CHOICE OF PROFESSIONALS

University of New Hampshire Scholars' Repository

Roof Inspection Report

SITE AND BUILDING INSPECTION CHECKLIST

PRODUCT PORTFOLIO or visit uniflexroof.com 101 PROSPECT AVE NW, CLEVELAND, OHIO PD TAGUNFL 640/18. 08/18 Uniflex Coatings

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH

The mission of RCI, Inc. is to advance the profession of

SECTION TOPSHIELD GUIDE SPECIFICATION SMOOTH AND GRANULE SURFACE ROOF RESTORATION TS-AC yr

Coal Tar Application and Design Considerations

2018 British Columbia Building Code Public Review of Proposed Changes

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists

TOPCOAT Matrix Brochure

A Guide to Maximizing the Life of your Roof through Preventive Roof Maintenance

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

The Fleming Update. Getting Your 2016 Repair & Maintenance House in Order. First Quarter Aaron Wolf, President. Articles Inside.

SECTION 8130 XR-3-PW FABRIC BAFFLE WALL SPECIFICATION

Liquid Membrane Systems Product Guide

Installation Applications

SECTION LIGHTWEIGHT INSULATING CONCRETE

ACRYLIC Elastek #127 Solar One Plus

ROOF MAINTENANCE GUIDE SMC Group Inc.

Recognizing and Addressing Moisture Concerns by Mike Endredi

DIVISION 7 THERMAL AND MOISTURE PROTECTION

Transcription:

BEFORE ALL HAIL BREAKS LOOSE! 2018 MHEC MPP LOSS CONTROL WORKSHOP MARCH 8, 2018 Jared Stolin Property Risk Consultant, Marsh Risk Consulting St. Louis, MO

Objectives Hail Hazard for MHEC MPP Types of Hail Damage to Facilities Hail Mitigation New Projects Existing Buildings 3 Key Takeaways to follow up on at your Campus

Hail Hazard Map Swiss Re CatNet

Hail Hazard Map FM Global FMDS 1-34

FMDS 1-34 Hailstorm Hazard Map Hail day: A day where minimum ¾ in. (19 mm) diameter hail occurred within 25 mi (40 km) of a location. Very Severe Hail Hazards Areas in the United States shown as Very Severe in Figure 8, Hail Storm hazard map for the United States. Severe Hail Hazard Areas that have experienced on average at least three hail days per year. Moderate Hail Hazard Areas that have not experienced on average at least three hail days per year.

MHEC MPP Campus Location Map Source: Global Risk Consultants

MHEC MPP Campus Location Map

MHEC MPP Campus Locations Hail Ratings by Location (FMDS 1-34) Very Severe 23% Moderate 22% Severe 55%

MHEC MPP Losses 2013-2017 14 reported hail losses Total $20,714,281 Average $1,479,592 Median $605,969

Common Hail Damage to Facilities Damage to Roofing Components Roof Covers & Substrates Skylights Vents Flashing Damage to Walls/Wall Panels Damage to equipment Rooftop Units HVAC Solar and other equipment Water damage to interior of building Restoration cost Replacement of furnishings or equipment

Damage to Roofing Components Many types of roof covers for both flat and sloped roofs Factors that influence susceptibility to hail damage to all types of roofs is Age Weathering Degradation Temperature Listed/Approved Components According to FM Global, the most damageable roofs are asbestos-cement, cementitious fiber and any roof in poor condition.

Damage to Roofing Components

Damage to Roofing Components

Damage to Roofing Wall Panels

Damage to Roofing Components Source: http://rci-online.org/

Damage to Roofing Components Source: http://rci-online.org/

Damage to Roofing Components

Damage to Equipment Source: FMDS 1-34

Damage to Equipment

Hail Mitigation New Installations: Specify proper Hail Approval/Listing Roofing Systems Wall Panels Skylights Hail Guards Condensor Fins Equipment Existing Installations: Roof Inspection Program Qualified Contractors Hail Guards for Equipment Age matters

New Roof Installations Stone or paver ballasted roofs are acceptable for all hail ratings (some limitations) ANSI FM 4473: Test Standard for Impact Resistance Testing of Rigid Roofing Materials by Impacting with Freezer Ice balls. Hail Hazard Area (FMDS 1-34) Roof Hail Rating single-ply, multi-ply or panel roofs Shingle Roofs Very severe (VSH) VSH FM Class 4 Severe (SH) VSH, SH FM Class 3 or 4 Moderate (MH) VSH, SH, MH FM Class 2, 3, or 4

ANSI FM 4473 Ice balls are used in this test method to simulate hailstones. The test specimen shall show no evidence of visible cracking or breakage or any damage such as punctures, fractures, disengagement of lap elements or exposure of materials not so intended.

Other Standards UL 2218 Standard for Impact Resistance of Prepared Roof Covering Materials ASTM D3746 Standard Test Method for Impact Resistance of Bituminous Roofing Systems

Roof Inspection Program Why? Age and condition matter! ANSI FM 4473: Exposure of roof coverings to the elements over an extended period of time has a potential to significantly lower the hail resistance of the roof materials.. How Often? Scheduled roof inspections at least 2 times per year (spring and fall) Additional inspections after major storms Document the age and condition of all roofs for important buildings GRC property surveys for all MHEC MPP members will include audits of the roof inspection programs

Roof Inspection Program Conditions that make certain roofs prone to hail damage. Built-up and modified bitumen: Original surface coating, such as granules or gravel missing blisters, deteriorating felts (scrim is showing) and alligator surfaces Single-ply membranes: crazing (very fine cracks in the membrane surface) stretching at the edges and seams, indicating probable embrittlement. Liquid applied roof covers: crazing, cracking, peeling, flaking or erosion.

Roof Inspection Program Source: FMDS 1-34

Roof Inspection Program Source: http://rci-online.org/

Roof Inspection Program Source: http://rci-online.org/

Roof Inspection Program

Roof Inspection Program Routine inspections can be done by a competent person When issues or concerns are found contact your roofing consultant Registered roof consultant (RRC) is a designation made by RCI, Incorporated; which is an international association of professional consultants, architects, and engineer who specialize in the specification and design of roofing, waterproofing, and exterior wall systems. http://rci-online.org/ Reference MHEC Property Risk Control Standards section 8: Roof Maintenance

Walls, Panels & Skylights Walls: Select wall systems that are inherently fire and hail resistant such as brick or concrete block. Select wall panels with Approved/Listed hail rating Skylights: Select Approved/Listed hail rating Skylights can also be protected with minimum No. 11 gauge diameter steel wire mesh with maximum mesh opening size of 1.0 in.

Equipment Cooling Fins for HVAC Units: Provide hail guards or steel wire mesh Min No. 11 gauge diameter steel wire mesh with maximum mesh opening size of 1.0 in. and supported on a steel framework Roof Vents: Steel Wire Mesh

3 Takeaways 1.Specifications for New Projects Do specifications for new construction and renovations include proper hail ratings for roofs, skylights, wall panels? 2. Inspection Program Is there a formalized/documented roof inspection program? At lease 2 scheduled inspections per year and after major storms? Repairs being performed by qualified personnel (RRC)? Do we have hail guards on condensor fins or other rooftop equipment? 3. Age and Condition Do we document the age and condition of all our roofs on campus?