Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System

Similar documents
Promistyl 3005T - roofing

Trimform for panels, purlins & gutters. No obligation consultation

Architectural Roofing

Standing Seam Roofing & Wall Cladding System. Building the Ultimate Dreams

specification clauses 1

Kingspan Day-Lite Trapezoidal FAS Product Data Sheet

Architectural Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

SPECIFICATIONS FOR PROPOSED

Architectural Roof and Wall Products Guide Specifications

Kingspan Day-Lite Trapezoidal Product Data Sheet

Standing Seam Systems. Architectural Standing Seam Roofing System. KingZip SF

Hip Detail. Construction Details. KS1000 LP/CR Roof. Hip Detail STANDARD ENHANCED ENHANCED STANDARD. Mineral fibre insulation

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

SECTION ROOFING AND SIDING PANELS

Insulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION COPPER STANDING SEAM ROOFING

Revolutionary Spacer Support Bar and Bracket System for Built Up, Twin Skin Roofing and Cladding Applications

TATA BLUESCOPE STEEL LIMITED PRODUCT SPECIFICATION LANGUAGE FOR PRE ENGINEERED STEEL BUILDING (BUTLER BUILDING SYSTEM- WITH MR-24 ROOF SYSTEM)

Architectural Roof Products Guide Specifications

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal SF Insulated Roof Panel KS1000 RW SF

Insulated Roof & Wall Panels. KS1000 TD Data Sheet. Topdek Single Ply Roof Deck. Insulated Panels

PRE-ENGINEERED METAL BUILDING SYSTEM

SSL-175. Specifications

BENCHMARK Evolution Axis

SECTION PRE-ENGINEERED BUILDING INSULATION

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8

Architectural Roof Products Guide Specifications

Invite to Tender: Wick Squash Club, cladding replacement

Architectural Roof and Wall Products Guide Specifications

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Trapezoidal Secret-Fix (SF) Insulated Roof Panel KS1000 DR/DRC Data Sheet

Curtain Wall Stick System (Capped)

Insulated Roof & Wall Panels. Product Data Sheet. Curved Roof Insulated Panel KS1000 CR

SPECIFICATION. ~ (project name) ~ (project address) ~ (owners name)

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Onduline covers the world. More than 100 countries across the globe

CONTOUR CORRUGATED PANEL

KingZip IP Standing Seam Insulated Panel KS500/1000 ZIP IP Data Sheet

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW

New versatile and effective dry fix solutions for the roofline and above

GM-CM30078-RevA. Metalcraft Insulated Panel Systems I Specification Guide V1 NZ I June

Unitised Curtain Wall Beaded

Guidance document January 2015

238T Aluminum Standing Seam Metal Roof System (SSMRS)

Kingspan Topdek KS1000 TD Insulated Single Ply Roofdeck Installation Guide

CI/Sfb. (47) Nh May Ziplok Z I P - U P S T A N D I N G S E A M R O O F I N G S Y S T E M

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

TATA BLUESCOPE STEEL LIMITED PRODUCT SPECIFICATION LANGUAGE FOR PRE ENGINEERED STEEL BUILDING (BUTLER BUILDING SYSTEM- WITH BR-II ROOF SYSTEM)

SECTION ROOF SPECIALTIES

3' COMMERCIAL RIB PREFORMED METAL SIDING

RUUKKI FORMA DESIGN INSTRUCTION

SECTION METAL ROOF PANELS

H92 RAINSCREEN CLADDING

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW

SECTION STAINLESS STEEL WALL PANELS

ReflectiClean Acrylic/Urethane

Mega 5. Specific Profile Data Sheet BACK. Table of Contents. Technical Drawing File Downloads

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

J41 Reinforced bitumen membrane roof coverings

Guide Specification SDP 200

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

Talius Energy Efficiency Recommended Specification

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

Kingspan Day-Lite Kapture Data Sheet

AMS MU800 Matrix Curtain Walling

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline

Metafor Panel System Installation Guide

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

Trapezoidal. Vertically Laid Insulated Wall Systems. Product Data 527. Model Specifications 531. Fastener Selection 541. Construction Details 543

SECTION PRE-ENGINEERED METAL BUILDING

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Bracket CHECK: PCL Varies - See Table. System Depth Excluding deck. U Value at 1.5M Centres. 202mm mm 0.16.

Sinusoidal Insulated Roof Panel KS1000 SRW Data Sheet

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

STANDING SEAM ROOF SYSTEM. Nucor CFR

TRIAD CORRUGATED METAL, INC.

Code Compliance Research Report CCRR-0228

Corrugated sheet for single storey, sectional buildings and stables

North Hanover Township School District North Hanover Township, New Jersey

Brownbuilt BROWNBUILT PROFILED SHEETING AND ACCESSORIES SHEETING FINISH FOR BROWNBUILT ROOF SHEETING FIXING BROWNBUILT BROWNBUILT FLASHINGS SAFETY

TYPICAL ROOF CONDITION LAYOUT

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

This specification is based on recognized manufacturer s specifications and guidelines for prefinished steel wall systems.

Hi Five. Specific Profile Data Sheet BACK. Table of Contents. Technical Drawing File Downloads

DL-200. Specifications

ONDULINE MINI 18. The stylish Do it Once roofing upgrade for your garden buildings.

Sheet Metal Flashing and Trim

Lo-Pitch Insulated Roof Panel KS1000 LP Data Sheet

SECTION STEEL DECKING

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

ROOFING & REINFORCEMENT SPECIALISTS

Transcription:

NBS Specification KingZip SF Standing Seam Roofing System

H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read with Preliminaries/General conditions. TYPE OF CLADDING SYSTEM 140 METAL PROFILED CLADDING TO ROOF: Drawing reference(s): Supports: Galvanised Mild Steel Purlins Bearing width: Refer to structural Engineers drawings, a minimum bearing width suitable for KingZip SF of 60mm Pitch: (where applicable): Refer to Architects drawings, a min of 1.5 deg min after deflection External sheets: Mechanically Zipped Aluminium Secret-Fixed Standing Seam Roofing System. Manufacturer and reference: Kingspan Insulated Panels Manufacturing LLC Material: - Aluminium Alloy- EN AW-3004 AIMn1Mg1. Ultimate tensile strength - min 225 N/mm². 0.2% Proof stress min 200 N/mm². Modulus of elasticity - 70,000 N/mm². - Profile reference: KingZip SF with 65mm standing seam (400mm cover width) - Nominal thickness/gauge: 1.2mm - External Finish/Colour: High build Durabond paint finish; colour to engineer s choice from manufacturer s standard range - Other requirements: KingZip SF sheets to be in one length as much as possible to avoid horizontal laps Flashing: - Aluminium alloy, gauge/thickness and finish to match roof external/internal sheet as applicable Accessories: - Extruded Aluminium Alloy (EN AW-6082) 85mm Halters to galvanised mild steel purlins with stainless steel fasteners. Thickness of sub-purlin and bracket to be determined based on length of KingZip SF sheet but a minimum of 1.6mm. Thermal barrier pads to halter base - Extruded Aluminium Alloy Halters 85mm - Thermal Barrier Pads - Pressed Aluminium Alloy Channel Verge Cap - Pressed Aluminium Alloy Ridge Support - Ridge Closure Zed - Pressed Aluminium Alloy Drip Angle 60 x 30mm - Fabricated Aluminium Alloy (AA3004) Flashings Material and finish as per cladding sheets or as per project requirements. - Side Laps: To be mechanically seamed with a KingZip SF zipping machine. - Primary cladding sheet fasteners: 6.3mm diameter grade 304 stainless steel self-tapping screws complete with 16mm diameter stainless steel/epdm bonded washers thread type and length to suit construction. Minimum 2 fixings per clip as supplied and manufactured by Kingspan Insulated Panels Manufacturing LLC - End laps: None required - Operatives must be fully trained and conversant with system manufacturer s methods for fixing and specifications. -

130 KingZip SF sheets to be roll-formed on site using Kingspan Insulated Panels Manufacturing LLC mobile rollforming production unit. KingZip SF system shall be tested and certified by FM, UL, ASTM and Dubai Civil Defence, as applicable. FIXING CLADDING 210 STRUCTURE: Check that structure is in a suitable state to receive cladding before commencing fixing. Subcontractor must confirm acceptance to Main Contractor and Chief Architect. 211 STRUCTURE: Support structure tolerances to be as per cladding manufacturer s recommendations. 215 STRUCTURE: Do not fix cladding until final coats of paint have been applied to outer surfaces of supporting structure. 217 PROTECTION: Store metal sheets and panels under cover to keep dry and prevent staining. Storage should be all in accordance with the sheet and panel manufacturer s recommendations. Store plastics sheets/roof-lights weather side up, under cover and on firm level bearers. Stack no higher than 1 metre and prevent mechanical damage and solar overheating. Adequately secure stored sheets/panels to prevent wind and mechanical damage. 219 FASTENINGS GENERALLY: Type(s), size(s), material(s) and finish(es) as specified, or in the absence of such specification, as recommended for the purpose by the cladding manufacturer. 221 FITTINGS AND ACCESSORIES GENERALLY: Cappings, closure pieces, flashings, trims, sills, gutters, fillers, spacers, tapes, sealants, fixings, etc., where not specified, to be types recommended by cladding manufacturer. 222 METAL GUTTER: Manufacturer: Kingspan Insulated Panels Manufacturing LLC or equal approved Location: As shown on drawings Girth: As derived from water flow calculations

Skins: Outer skin to be 2mm gauge aluminium sheet, confirming to alloy AA 3105 temper H44, finished with Polyester high build paint. Liner to be 0.7mm gauge galvanised steel in a Polyester painted finish. Colour for external and internal skins of gutter to match that of the roof cladding system. Other requirements: 5mm thick colour matched galvanized steel supports to be provided at every 500mm (maximum). Expansion joints to be provided at every 8.2 meters (maximum) using proprietary T-Pren joints. Gutter shall be supplied in maximum 3 metre lengths and joints to be site welded by Kingspan Insulated Panels Manufacturing LLC -approved welding specialist. Proprietary aluminium down spouts shall be welded to the gutter bed at site. Weld lines shall be cleaned and post painted to colour match sheets at site. 223 ISOLATING TAPE: A type recommended for the purpose by the cladding manufacturer. Apply to those surfaces of supports which would otherwise be in contact with cladding or accessories after fixing. 300 PROFILE FILLERS: Manufacturer and reference: Kingspan Insulated Panels Manufacturing LLC Material: Closed cell cross-linked polyethylene with a minimum density of 30 kg/m3. Colour: Black Locate where shown on drawings and wherever necessary to close off corrugation cavities from the outside and inside of the building. Ensuring a tight fit, leaving no gaps. 410 FIXING SHEETS GENERALLY: Cut sheets and flashings to give clean true lines, with no distortion. Remove burrs and any lubricant Cut openings in sheets for outlets, vent pipes, flues, etc. to the minimum size necessary and as per the cladding manufacturer's recommendations. For double skin construction do not line out building completely before installation of outer sheets. Lay sheets with exposed joints of side laps away from prevailing wind unless shown otherwise on drawings. Ensure that ends of sheets, and end laps are fully supported with fixings at top of lap. Ensure that raking cut edges at hips and valleys are fully supported. Drill all holes and install fasteners perpendicular to the surface of the cladding. Position fasteners at regular intervals in straight lines, centred on support bearings. Locate fasteners centrally within holes that are oversized. Remove dust and any other foreign matter before finally fixing sheets into position. Protect sheets adequately during fixing and up to Practical Completion against mechanical damage and disfigurement. Rectify any defects as quickly as practicable to minimise damage and nuisance. Install fasteners to correct tightness using any special tools recommended by the fastener manufacturer. When used, screw guns must be fitted with depth sensitive devices and used at the correct speed. Check fastenings on completion and adjust as necessary to ensure that they are watertight and sheeting is secure but not buckled or distorted. Paint all cut edges to match face finish. 411 FIXING KINGZIP SF SHEETS: KingZip SF sheets to be installed by mechanically seaming sheets to support clips with KingZip SF zipping machine. KingZip SF sheets to be installed as per cladding manufacturer s instructions.

Only roofing contractors who are members of Kingspan Insulated Panels Manufacturing LLC approved Roofing Contractors Programme should be employed to install KingZip SF roofing. Aluminium Site Welding: Aluminium Site Welding (TIG) will be fully in accordance with Kingspan Insulated Panels Manufacturing LLC standard recommendations and industry guide to good practice by company approved welding contractors. Site Welding must be carried out fully in accordance with Approved Welding Procedure Specification ASW/TIG/001 Rev B 1997 as defined in BS EN ISO 9606-2 for material gauges between 0.8mm-3.0mm thickness. Site welding operatives must be certified to acceptable standard for material gauges between 0.8mm-3.0mm thickness. The weld test procedure shall be in accordance with BS EN ISO 15614-2:2005 470 STRUCTURAL MOVEMENT JOINTS: Leave space between sheets to coincide with structural movement joints. Fix movement joint cover to sheets on one side only. Movement joint cover details to be as per cladding manufacturer s recommendations. 560 WARNING NOTICES: Signs as described below to be fixed at points indicated on drawings. Manufacturer and reference: Kingspan Insulated Panels Manufacturing LLC, KingZip SF Material: Aluminium Description: Warning sign as BS 5378: Part 3 reference A.2.4 with supplementary text sign, lettering 'DANGER Fragile roof'. Mandatory sign as BS 5378: Part 3 reference A.3.1 with supplementary text sign, lettering 'USE CRAWLING BOARDS. 590 FALL ARREST SYSTEM: Product : Kingspan Safepro 2 Supplier and reference: Kingspan Fabrications, Safety and Lighting Solutions, sub-division of Kingspan Insulated Panels, Greenfield Business Park No 2, Holywell, Flintshire. CH8 7GJ. United Kingdom. www.kingspanpanels.co.uk or equivalent. Authorized Agent: Marine Tech LLC, PO Box 283852, Dubai, UAE Tel: +971 4 340 8624, Fax: + 971 4 3409615, Mob: +971 50 6575741 Email: fallarrest@marinetech.ae www.marinetech.ae 120 METAL ROOF ACCESS WALKWAY Product reference: KingZip SF Walkway with or without handrails Manufacturer: Kingspan Insulated Panels Manufacturing LLC, P.O. Box 60453, Dubai, UAE. Walkway surface: Kingspan perforated profiled sheet Finish: Natural aluminium or powder coated Support members: Extruded aluminium profiles. Fixing: Zipklip non-penetrative fixing clamp

Kingspan Insulated Panels Manufacturing LLC Dubai Investment Park, Jebel Ali, Dubai, U.A.E. P.O. Box: 60493 t: +971 (0) 4-8854 232 f: +971 (0) 4-8854 223, Email info@kingspanpanels.ae