SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

Similar documents
Seismic Collapsing Process Analysis of One-story Thatched Roof Wooden Structure under Strong Earthquake Ground Motion

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

Collapsing Simulation of Wooden House Retrofitted by ACM Braces During Seismic Ground Motion

SEISMIC PERFORMANCE EVALUATION OF RETROFITTED WOODEN-HOUSE BY COLLAPSING PROCESS ANALYSIS

Seismic Collapsing Response Analysis of Wooden House Retrofitted by ACM Braces

Seismic Collapsing Analysis of Two-Story Wooden House, Kyo-machiya, against Strong Earthquake Ground Motion

Seismic Collapsing Behaviour of Three-story Wooden House under Strong Earthquake Ground Motion

Seismic performance of Japanese-style two-story wooden house against the 2016 Kumamoto Earthquake

Seismic Response Evaluation ofnew WoodenHouse by Collapsing Process Analysis

Seismic damage prediction of old Japanese-style wooden house using predominant period distribution of ground surface layer

EXPRIMENTAL AND ANALYTICAL STUDY ON SEISMIC BEHAVIOR OF TRADITIONAL WOODEN FRAMES CONSIDERING HORIZONTAL DIAPHRAGM DEFORMATION AND COLUMN SLIPPAGE

FULL SCALE STATIC LOADING TESTS FOR TWO STORIED PLANE FRAME OF TRADITIONAL TOWN HOUSE IN KYOTO, JAPAN

E-DEFENSE EXPERIMENTS ON FULL-SCALE WOODEN HOUSES

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

MID-STORY SEISMIC ISOLATION FOR STRENGTHENING OF A MULTI-STORY BUILDING

WIRE-ROPE BRACING SYSTEM WITH ELASTO-PLASTIC DAMPERS FOR SEISMIC RESPONSE REDUCTION OF STEEL FRAMES

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

Structural Design of Super High Rise Buildings in High Seismic Intensity Area

Development of Cylindrical Passive Damper using High Damping Rubber

EXPERIMENTAL STUDY ON DYNAMIC BEHAVIOR OF WOODEN FRAMES WITH PASSIVE CONTROL SYSTEM AND INNER-AND-OUTER WALLS USING SHAKING TABLE

INFLUENCE OF BNWF SOIL MODELLING ON DYNAMIC BEHAVIOUR OF PILE FOUNDATION FOR RC FRAME WITH STRUCTURAL WALL

EARTHQUAKE RESPONSE ANALYSIS OF A MID-STORY SEISMIC ISOLATED BUILDING

SEISMIC ENERGY DISSIPATION SYSTEM OF 12-STOREY COUPLED SHEAR WALLS

A SHAKING TABLE TEST OF REINFORCED CONCRETE FRAMES DESIGNED UNDER OLD SEISMIC REGULATIONS IN JAPAN

ON THE SEISMIC UPGRADING OF EXISTING BUILDING BY SEISMIC ISOLATION SYSTEM

SEISMIC DESIGN OF STRUCTURE

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings

The Evaluation for the Structural Performance of Traditional Townhouses with Timber Through Columns in Japan

International Journal of Engineering and Techniques - Volume 4 Issue 2, Mar Apr 2018

NONLINEAR DYNAMIC BEHAVIOR AND SEISMIC ISOLATION OF STEEL TOWERS OF CABLE-STAYED BRIDGES UNDER GREAT EARTHQUAKE GROUND MOTION

CORRELATION OF BUILDING DAMAGE WITH INDICES OF SEISMIC GROUND MOTION INTENSITY DURING THE 1999 CHI-CHI, TAIWAN EARTHQUAKE

COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES

SEISMIC RESPONSE OF A REINFORCED CONCRETE ARCH BRIDGE

CONTROL EFFECT OF LARGE TUNED MASS DAMPER APPLIED TO EXISTING HIGH-RISE BUILDING FOR SEISMIC RETROFIT

EARTHQUAKE RESPONSE OF AN ELEVEN-STORY PRECAST PRESTRESSED CONCRETE BUILDING BY SUBSTRUCTURE PSEUDO DYNAMIC TEST

Damage Concentration in Multi-Story Buckling Restrained Braced Frame (BRBF) Relations with participant ratioβof BRB-

Application of Isolation Technology in High-voltage Electrical Equipments

Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures

Effect of Seismic Reinforcement of Sheet Pile Quay Wall Using Ground Anchor

STUDY ON THE DAMAGES OF STEEL GIRDERS BY HYOGO-KEN NANBU EARTHQUAKE USING NONLINEAR SEISMIC RESPONSE ANALYSIS

SEISMIC CAPACITY INDEX OF EXISTING HIGH-RISE RC BUILDINGS IN JAPAN

SEISMIC RESPONSE EVALUATION OF 30 STORY HIGH-RISE RC BUILDING SUBJECTED TO 2011 TOHOKU EARTHQUAKE

ULTIMATE EARTHQUAKE RESISTANT CAPACITY OF CFT-FRAME

Wataru Goto. NTT FACILITIES, INC. in Japan. 15th World Conference on Earthquake Engineering 24 to 28 September 2012 LISBON PORTUGAL

Literature Review of Wood-frame Structure Tests

A Method of Dynamic Nonlinear Analysis for RC Frames under Seismic Loadings

Study on Improvement of Seismic Performance of Transmission Tower Using Viscous Damper

Research on the Seismic Performance of an Externally Prestressed Rocking Reinforced Concrete Frame

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

Soil-Structure Interaction Effects on Building Response in Recent Earthquakes

RETROFITTING METHOD OF EXISTING REINFORCED CONCRETE BUILDINGS USING ELASTO-PLASTIC STEEL DAMPERS

Department of Civil Engineering, SKP Engg. College, Tiruvanamalai, TN, India

Bi-Directional Experimental Hybrid Simulations of Elastomeric Isolation Bearings for Validation of Hysteretic Modeling

Dual earthquake resistant frames

PSEUDO DYNAMIC TESTS AND IMPLEMENTATION OF SLIDING BRIDGE ISOLATORS WITH VERTICAL MOTION

SEISMIC SOIL-STRUCTURE INTERACTION (SSI) EFFECTS FOR A DIFFERENT TYPE OF BUILDINGS IN DENSE URBAN AREA

DEVELOPMENT OF UNBONDED BAR REINFORCED CONCRETE STRUCTURE

Performance Improvement of Tall Reinforced Concrete Structures with Multiple Tuned Mass Dampers (MTMD)

Seismic Assessment of Traditional Masonry-Wooden Building in Taiwan

PERFORMANCE BASED ANALYSIS OF R.C.C. FRAMES

Effect of lintel on horizontal load-carrying capacity in post-beam structure

User Elements Developed for the Nonlinear Dynamic Analysis of Reinforced Concrete Structures

Damage states of cut-and-cover tunnels under seismic excitation

Seismic Evaluation of the Historic East-Memorial Building Retrofitted with Friction Dampers, Ottawa, Canada

DAMAGE ANALYSIS AND SEISMIC DESIGN OF RAILWAY STRUCTURES FOR HYOGOKEN-NANBU (KOBE) EARTHQUAKE

COMPUTER AIDED DESIGN AND ANALYSIS OF RC FRAME BUILDINGS SUBJECTED TO EARTHQUAKES

RESPONSE STUDY OF MULTI-STORIED BUILDINGS WITH PLAN IRREGULARITY SUBJECTED TO EARTHQUAKE AND WIND LOADS USING LINEAR STATIC ANALYSIS

ICSS(4): A DESIGN APPLIED FOR A SUPER LONG MULTI-SPAN BRIDGE

Seismic Performance Evaluation on Historical Timber Frame Structures with Large Hanging Walls

DEVELOPMENT OF THE STRUCTURAL DESIGN AND CONSTRUCTION GUIDELINE FOR HIGH-RISE PC BUILDINGS - JAPANESE PC PROJECT

STUDY OF LOW-RISE RC BUILDINGS WITH RELATIVELY HIGH SEISMIC CAPACITY DAMAGED BY GREAT EAST JAPAN EARTHQUAKE 2011

Mechanical behavior and design method of weld-free steel structure with knee brace damper using square tube column

Offering a step-change in seismic technology

DUAL SYSTEM DESIGN OF STEEL FRAMES INCORPORATING BUCKLING-RESTRAINED BRACES

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

SHAKING TABLE TEST USING MULTIPURPOSE TEST BED

SEISMIC PERFORMANCE OF FLAT SLAB WITH DROP AND CONVENTIONAL SLAB STRUCTURE

Improving the Seismic Response of a Reinforced Concrete Building Using Buckling Restrained Braces

Research on seismic safety, retrofit, and design of a steel cable-stayed bridge

Modelling the seismic response of light-timber-framed buildings

RESIDUAL SEISMIC CAPACITY AND DAMAGE EVALUATION OF HIGH-RISE RC BUILDINGS

Wire-rope Bracing System with Central Cylinder,

APPLICATION OF OPTIMUM DESIGN METHODS TO ACTUAL HIGH-RISE BUILDING WITH HYSTERETIC DAMPERS

Comparison between Seismic Behavior of Suspended Zipper Braced Frames and Various EBF Systems

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

EXPERIMENTAL STUDY ON HYSTERETIC DAMPER WITH LOW YIELD STRENGTH STEEL UNDER DYNAMIC LOADING

Seismic Performance Evaluation of an Existing Precast Concrete Shear Wall Building

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

COLUMN-TO-BEAM STRENGTH RATIO REQUIRED FOR ENSURING BEAM- COLLAPSE MECHANISMS IN EARTHQUAKE RESPONSES OF STEEL MOMENT FRAMES

Comparison of Chevron and Suspended Zipper Braced Steel Frames

Seismic Rehabilitation of Selby Condominium Complex, Montreal (Quebec), Canada

Performance Evaluation for Traditional Japanese Wooden Pagodas based on Micro-tremor Measurement and Numerical Frame Model Analysis

Seismic Analysis of Multi Storey Building with Flat Slab Resting on Plain and Sloping Ground

Dynamic Elastic-plastic Analysis of High-rise Steel Structure with Buckling-restrained Braces Fei OuYang a,chengwei Huang b,guihu qin c

FROM INFANCY TO MATURITY OF BUCKLING RESTRAINED BRACES RESEARCH

INTRODUCTION OF A PERFORMANCE-BASED DESIGN

An experimental study of structural plastic hinge development and nonlinear soil deformation

Floating Type Isolation System Using Earthquake Early Warning

Influence of Vertical Acceleration on Seismic Response of Endbearing

Transcription:

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION Tomiya Takatani 1, * and Hayato Nishikawa 2 1 National Institute of Technology (NIT), Maizuru College, Department of Civil Engineering and Architecture, 234 Shiraya, Maizuru, Kyoto 625-8511, Japan.*Email:takatani@maizuru-ct.ac.jp 2 National Institute of Technology (NIT), Maizuru College, Education and Research Supporting Centre, 234 Shiraya, Maizuru, Kyoto 625-8511, Japan. ABSTRACT In Japan, there has existed a serious problem on seismic retrofit for a lot of one-story wooden structures such as temples and shrines in famous tourist resort areas, which were built by a Japanese traditional framedconstruction method and have some types of thatched roof instead of tiles. In order to investigate the seismic behaviour of an old one-story thatched roof wooden structure, Yakushi-doh, 3-D non-linear collapsing process analysis of Yakushi-doh structure was conducted against a strong earthquake ground motion with the Japan Meteorological Agency seismic intensity of 6 upper level. A non-linear behaviour of timber elements in the wooden structure during a strong earthquake ground motion can be simulated by this 3-D non-linear collapsing process analysis based on the Distinct Element Method. The effect of the post fixing condition under wooden structure floor on seismic response of Yakushi-doh structure was numerically investigated in this paper. KEYWORDS One-story wooden structure with thatched roof, 3-D non-linear collapsing process analysis, seismic response. INTRODUCTION It is well known that a great number of wooden houses collapsed in the 1995 Hyogo-ken Nanbu Earthquake. In order to investigate seismic performance of wooden house against a strong earthquake ground motion, seismic collapsing analyses (Nakagawa and Ohta 2010; Takatani 2013, 2014; Takatani and Nishikawa 2012, 2014) for many Japanese old wooden houses built by a Japanese traditional framed-construction method have been conducted by 3-D non-linear collapsing process analysis based on the Distinct Element Method (Cundall and Strack 1979). In Japan, there has existed a serious problem on seismic retrofit for a lot of one-story wooden structures such as temples and shrines in famous tourist resort areas, which were built by a Japanese traditional framedconstruction method and have some types of thatched roof instead of tiles. Because they are important cultural assets in Japan, it may be so difficult and not a good plan from a view point of scenery preservation to reconstruct these thatched roof wooden structures to conduct their seismic retrofits. It is, therefore, very important for structural engineers to perform seismic retrofit for one-story thatched roof wooden structure without reconstruction. In order to investigate the seismic behaviour of an old one-story thatched roof wooden structure, Yakushidoh, 3-D non-linear collapsing process analysis of Yakushi-doh structure was conducted against a strong earthquake ground motion with the Japan Meteorological Agency (JMA) seismic intensity of 6 upper level. In general, the posts under an old wooden structure floor of Yakushi-doh structure are erected on their foundation stones and are not fixed. In this paper, the effect of the post fixing condition under wooden structure floor on seismic response of Yakushi-doh structure was numerically investigated by using two earthquake ground motions measured in 1995 in the seismic collapsing analysis. OUTLINE OF YAKUSHI-DOH STRUCTURE Photo 1 shows one-story wooden structure with thatched roof, Yakushi-doh structure, which was built an old Japanese traditional framed-construction method and have a thatched roof instead of tile. Yakushi-doh structure was dedicated in 1617 to deify Bhaisajyaguru, who has been believed in a Buddha able to cure all ills, and has been an important cultural asset. Figure 1 indicates floor plan, elevation one, and cross section ones of Yakushidoh structure. The width, depth, and height of Yakushi-doh structure are 13.211m, 11.756m and 10.254m, respectively. Photo 2 shows a post erected on a foundation stone under Yakushi-doh structure floor. There are many posts erected on their foundation stones with flat plane under Yakushi-doh structure floor, and they are not fixed on their foundation stones. Consequently, this system is likely to be a seismic base isolation. In this paper, the effect of the post fixing condition under wooden structure floor on seismic response of Yakushi-doh 348

Photo 1 One-story wooden structure with thatched roof, Yakushi-doh (a) Floor Plan No.3 No.2 (b) Front Elevation No.3 No.2 No.1 No.1 (c) Front Cross Section (d) Side Cross Section Figure 1 Plan design and elevation plan of Yakushi-doh structure Photo 2 Post erected on a foundation stone Figure 2 Collapsing wooden frame model 349

structure is numerically investigated through the seismic response behaviours at Nos.1 to 3, which are illustrated in Figure 1 and are three measuring points in the collapsing process analysis described below. OUTLINE OF COLLAPSING ANALSYS Seismic Collapsing Analysis In this paper, a structural analysis software of Wallstat is employed in order to investigate seismic response behaviour and collapsing process of Yakushi-doh structure during a strong earthquake ground motion. This software has an original analysis technique (Nakagawa and Ohta 2010) using the basic theory of the Distinct Element Method (Cundall and Strack 1979), and can be taken into consideration the extremely non-linear properties of timber members breaking or being dispersed. In the collapsing process analytical calculation, Yakushidoh structure can be modelled by a lot of timber elements such as beam and pillar connected with non-linear spring as shown in Figure 2, and also can be modelled by lumped mass and the weight of each floor in Yakushidoh structure model can be obtained from each structural element as illustrated in Figure 3. Timber characteristics of the compression and tensile elasto-plastic springs consist of an elastic part and slip-type part. Figure 3 Weight of floor in the analytical model of wooden house (Nakagawa 2011) Modelling of Structure Element - Modelling of Frame Timber frame is modelled by two elasto-plastic rotational springs (plastic hinge) and an elastic beam component as shown in the left-hand side of Figure 4. The spring can be defined by a relationship between bending moment M and angle of rotation with the skeleton curve indicated in the right-hand side of Figure 4. The bending moment starts to fall once if it is over the maximum bending moment, and the rotating spring changes to a pinned joint state at the point if the bending moment reaches 0, and then the beam component can be judged to have been broken. Figure 4 Schematic diagram and skeleton curve of frame spring (Nakagawa 2011) (a) Schematic diagram of joint (b) Characteristic of elasto- (c) Characteristic of element plastic spring rotational spring Figure 5 Outline of joint modelling (Nakagawa 2011) 350

- Modelling of Joint Spring Joint spring can be modelled by both an elasto-plastic spring and a rotational spring as shown in Figure 5(a). Timber characteristic of the compression and tensile elasto-plastic spring consist of an elastic part and slip-type part indicated in Figure 5(b), and also timber characteristics of the rotational spring is assumed to be a slip-type relationship between ending moment M and angle of rotation shown in Figure 5 (c). When the elasto-plastic spring or the rotational spring of the joint exceeds the maximum structural strength or moment and their strength values becomes 0, the joint will be adjudged to have been broken and then the spring will be annihilated. - Modelling of Shear wall and Bracing Vertical shear wall indicated in Figure 6 can be modelled by the replacement of truss component with a loaddisplacement non-linear relationship shown in Figure 8. Also, bracing shear wall illustrated in Figure 7 can be modelled by the replacement of compression and tensile truss components defined by a set of bi-linear and slip skeleton curve shown in Figure 8, too. - Parameters of Structural Element In general, Young s modulus and the maximum bending moment of timber component are assumed to be 2,000MN/m 2 and 10kNm, respectively. External and internal walls in a typical Japanese wooden house can be assumed to be lath mortal wall and clay wall, respectively. For seismic retrofit countermeasure for a wooden Figure 6 Shear wall spring (Nakagawa 2011) Figure 7 Outline of bracing shear wall (Nakagawa 2011) Figure 8 Hysteretic characteristics of shear wall and bracing (Nakagawa 2011) Table 1 Parameters for hysteretic characteristics of vertical shear wall (Nakagawa 2011) P 1 P 2 P 3 P 4 D 1 D 2 D 3 D 4 h (kn) (m) (%) Clay Wall 0.5 1.75 2.0 0.0 0.010 0.05 0.10 0.5 2 Lath Mortal Wall 1.0 3.50 4.3 0.0 0.002 0.01 0.05 0.2 2 Structural Plywood 3.0 9.50 10.5 0.0 0.010 0.06 0.12 0.3 2 h : viscous damping factor Table 2 Parameters for hysteretic characteristics of elasto-plastic spring (Tajima et al. 2000, Nakagawa 2011) Ks 1 Ks 2 Ks 3 D 1 D 2 (kn/m) (m) Stub Tenon 900-18.919-33.333 0.0015 0.02 Corner Bracing 5,128 651-154 0.0027 0.015 Table 3 Parameters for hysteretic characteristics of bracing spring (Nakagawa 2011) P 1 P 2 P 3 P 4 D 1 D 2 D 3 D 4 h (kn) (m) (%) Timber Brace1 0.500 2.500 2.800 0.000 0.001 0.015 0.050 0.250 2 Timber Brace2 1.500 4.500 6.700 0.000 0.002 0.053 0.110 0.200 2 Timber Brace3 4.500 8.500 9.200 0.000 0.003 0.061 0.150 0.200 2 351

house with lower seismic performance, a plywood is generally employed as internal wall. Parameters of hysteric characteristics of their walls are shown in Table 1. Parameters of stub tenon jointed at the interface between beam, column and corner bracing used for seismic retrofit work are described in Table 2. Table 3 shows the parameters of hysteretic characteristics of various timber braces used in a typical Japanese wooden house. Input Earthquake Motion in Seismic Collapsing Analysis Seismic collapsing process analysis of Yakushi-doh structure is carried out in this paper. Two earthquake ground motion wave records with the JMA seismic intensity of 6 upper level are employed as an input earthquake ground motion data in the collapsing analysis. The effect of the earthquake motion spectrum on the difference of seismic response can be investigated by using two earthquake wave records with the same level intensity which has a different peak frequency in Fourier acceleration spectra. Table 4 shows some parameters of two earthquake ground motion wave records used as an input excitation of the collapsing process analysis. Figures 9 and 10 indicate two displacement wave data and their Fourier acceleration spectra for both NS and EW components in each earthquake ground motion record shown in Table 4. In the JMA Kobe wave record indicated in Figure 9, a peak frequency in each wave component is from 1Hz to 1.5Hz, and also a peak in each wave component of the JR Takatori wave record illustrated in Figure 10 exists about 0.8Hz. Because there are peak frequencies in both the JMA Kobe and the JR Takatori wave records in the frequency range of 0.5 to 1.5Hz, their wave records seem to cause severe damage in the collapsing analysis of an old wooden structure against a strong earthquake ground motion as reported by Sakai et al. (2002). RESULTS AND DISCUSSIONS Seismic Collapsing Behaviour Figure 11 shows the seismic collapsing behaviour of Yakushi-doh structure under post fixed condition during the JMA Kobe earthquake ground motion wave shown in Figure 9. In seismic collapsing result of Yakushi-doh structure, the plastic deformation at the connection part between pillar and beam elements gradually increases during earthquake ground motion by means of the non-linearity characteristics. Yakushi-doh structure collapses after 16 seconds in the JMA Kobe wave record with a frequency range close to 0.5 to 1.0Hz. Figure 12 indicates the seismic collapsing behaviours of Yakushi-doh structure under post unfixed conditions of =0.2 and Table 4 Earthquake ground motion wave records (the 1995 Hyogo-ken Nanbu Earthquake) Record Name IJMA Peak Ground Acceleration (cm/s 2 ) Peak Ground Velocity (cm/s) fp (Hz) Duration (s) JMA Kobe 6.4 818 91 1.43 30 JR Takatori 6.4 657 126 0.81 30 fp : peak frequency of root mean square value of Fourier spectrum Figure 9 Displacement waves and Fourier acceleration spectra of the JMA Kobe wave Figure 10 Displacement waves and Fourier acceleration spectra of the JR Takatori wave 352

0.4 during the JMA Kobe earthquake ground motion wave. The sign in this figure means a dynamic friction coefficient between a post element and its foundation stone under the floor of Yakushi-doh structure. It is found from Figure 12 that the collapsing elements of Yakushi-doh structure trends to increase with the friction coefficient, because the decrease of friction coefficient means to become a seismic base isolation. Figure 11 Seismic collapsing behaviour during the JMA Kobe wave under fixed post condition Figure 12 Seismic collapsing state after the JMA Kobe wave under unfixed post condition 353

Figure 13 shows the seismic collapsing behaviour of Yakushi-doh structure under post fixed condition during the JR Takatori earthquake ground motion wave shown in Figure 10. In particular, Yakushi-doh structure collapses after 10 seconds in the JR Takatori wave record with a frequency range of 0.5 to 1.0Hz, and the frequency range has a significant relationship with an old wooden structure collapsing rate against a strong earthquake Figure 13 Seismic collapsing behaviour during the JR Takatori wave under fixed post condition Figure 14 Seismic collapsing state after the JR Takatori wave under unfixed post condition 354

Figure 15 Displacement responses at Nos.1 to 3. Figure 16 Displacement responses at Nos.1 to 3, the JMA Kobe wave 355

Figure 17 Displacement responses at Nos.1 to 3, the JR Takatori wave motion. Moreover, the maximum velocity of the JR Takatori wave record is 126cm/s, and the wooden structure collapsing rate greatly depends on the maximum velocity. Yakushi-doh structure collapses after 10 seconds in the JR Takatori wave record with the frequency range close to 0.5 to 1.0Hz. Figure 14 indicates the seismic collapsing behaviours of Yakushi-doh structure under post unfixed conditions of =0.2 and 0.4 during the JR Takatori earthquake ground motion wave. Yakushi-doh structure does not collapse under post unfixed condition of =0.2, while it collapses after 10 seconds under post unfixed conditions of =0.4. There exists a significant difference between =0.2 and 0.4 in seismic collapsing response. It is, also, found from these figures that the collapsing elements of Yakushi-doh structure trends to increase with the dynamic friction coefficient, because the decrease of friction coefficient means to become a seismic base isolation. Seismic Collapsing Response Figure 15 shows seismic collapsing responses at Nos.1 to 3 under post fixed condition during the JMA Kobe and the JR Takatori waves. The heights of three measuring points of Nos.1 to 3 indicated in Figure 1 are 3.8m,6.2m, and 9.3m, respectively. Although the timber element of No.1 does not fall down for each earthquake ground motion, the timber elements of Nos.2 and 3 falls down after 13 seconds for the JMA Kobe wave and they does after 10 seconds for the JR Takatori wave. On the other hands, seismic collapsing responses at Nos.1 to 3 under post unfixed conditions of =0.2 and 0.4 during the JMA Kobe wave are indicated in Figure 16. It is found from Figure 12 that three timber elements of Nos.1 to 3 have slightly horizontal deformation after earthquake wave and does not fall down because of post unfixed condition. Figure 17 shows seismic collapsing responses at Nos.1 to 3 under post unfixed conditions of =0.2 and 0.4 during JR Takatori wave. Three timber elements of Nos.1 to 3 under post unfixed condition of =0.2 have some horizontal deformation of Y direction after earthquake wave and does not fall down because of post unfixed condition. While, three timber elements of Nos.1 to 3 under post unfixed condition of =0.4 fall down after 10 seconds. CONCLUSIONS In order to investigate the seismic behaviour of an old one-story thatched roof wooden structure, Yakushi-doh, 3-D non-linear collapsing process analysis of Yakushi-doh structure was conducted against two strong earth- 356

quake ground motions with the Japan Meteorological Agency (JMA) seismic intensity of 6 upper level. The posts under Yakushi-doh structure floor are erected on their foundation stones and are not fixed. The effect of the post fixing condition under Yakushi-doh structure floor on seismic response was numerically investigated in this paper. The summary obtained in this paper is as follows. (1) Seismic collapsing behaviour of a one-story thatched roof wooden structure depends on the seismic intensity of the input earthquake motion in the collapsing analysis. (2) A one-story thatched roof wooden structure may be collapsed by a strong earthquake ground motion with the JMA seismic intensity of 6 upper level. (3) Seismic collapsing behaviour of wooden structure strongly depends on the post fixing condition under the floor of one-story thatched roof wooden structure. (4) The collapsing elements of Yakushi-doh structure trends to increase with the dynamic friction coefficient, because the decrease of dynamic friction coefficient means to become a seismic base isolation. In this paper, two earthquake ground motions measured in the 1995 Hyogo-ken Nanbu Earthquake are employed in this collapsing analysis of Yakushi-doh structure as a strong earthquake ground motions with the JMA seismic intensity of 6 upper level, because these earthquake ground motions have been used in a lot of seismic collapsing analyses of various structures to investigate the seismic behaviour during a strong earthquake ground motion. If a wooden structure does not collapse against these earthquake ground motions, it may have a high seismic performance against a strong earthquake ground motions with the JMA seismic intensity of 6 upper level. 3-D non-linear collapsing process analysis may be an effective tool to evaluate a seismic performance of wooden structure. Also, this collapsing process analysis has a significant potential to find when and where begin to break first in an old one-story thatched roof wooden structure during a strong earthquake ground motion. An optimum seismic retrofit of the one-story thatched roof wooden structure can be made by using the collapsing analysis. In addition, further investigation may be needed to simulate the collapsing process phenomenon of a one-story thatched roof wooden structure with or without seismic retrofit and make some concrete conclusions. REFERENCES Cundall, P. A. and Strack, O. D. L. (1979). A discrete numerical model for granular assemblies, Géotechnique, Vol.29, No.1, 47-65. Nakagawa, T. (2011). Development of analysis method for collapsing behaviour of wooden post-and-beam house during earthquake, Building Research Data, Building Research Institute (in Japanese). Nakagawa, T., Ohta, M. (2010). Collapsing process simulations of timber structures under dynamic loading III: Numerical simulations of the real size wooden houses, Journal of Wood Science, Vol.56, No.4, 284-292. Sakai, Y., Koketsu, K. and Kanno, T. (2002). Proposal of the destructive power index of strong ground motion for prediction of building damage ratio, Journal of Structural and Construction Engineering, Architectural Institute of Japan, No.555, 85-91 (in Japanese). Tajima, M., Murakami, M., Gotou, M., Inayama., M and Fukuda, M. (2000). Development of structural design method on conventional post and beam structures : Part 35 Result of shearthed diaphram with angle brace test, Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, 25-26(in Japanese). Takatani, T. (2013). Collapsing analysis of an old two-story wooden house against a strong earthquake ground motion, Proceedings of the 13th World Conference on Timber Engineering (WCTE 2013), Quebec, Canada. Takatani, T. (2014). Seismic collapsing analysis of two-story wooden house, Kyo-machiya, against strong earthquake ground motion, Proceedings of the 2014 International Conference on Geotechnical and Structural Engineering (CGSE 2014), Hong Kong, China. Takatani, T. and Nishikawa, H. (2012). Collapsing behaviour of retrofitted wooden house under seismic motion, Proceedings of the First International Conference on Performance-based and Life-cycle Structural Engineering (PLSE 2012), Hong Kong, China. Takatani, T. and Nishikawa, H. (2014). Seismic collapsing analysis of three-story wooden hotel, Proceedings of the Second Australasia and South East Asia Conference in Structural Engineering and Construction (ASEA-SEC-2), 277-282, Bangkok, Thailand. 357